OPERATING INSTRUCTIONS

Similar documents
CarSense202 O P E R A T I N G I N S T R U C T I O N S V E HI C L E M O T I O N D E T E C T O R Johnston Parkway, Cleveland, Ohio 44128

IRB-MON O P E R A T I N G I N S T R U C T I O N S UNIVERSAL SAFETY PHOTOEYE U L M O N I T O R E D DEVICE

IRB-RET O P E R A T I N G I N S T R U C T I O N S UNIVERSAL SAFETY RETROREFLECTIVE PHOTOEYE U L MONITORED DEVICE

IRB-MON UNIVERSAL SAFETY PHOTOEYE OPERATING UL MONITORED DEVICE

IRB-RET O P E R A T I N G I N S T R U C T I O N S UNIVERSAL SAFETY RETROREFLECTIVE PHOTOEYE U L M O N I T O R E D DEVICE

Bluetooth Enabled Access Control MODEL BG-FE. Operating Instructions

Operating Instructions

Universal Safety Photo Eye UL MONITORED DEVICE

User Guide. Control Box. RoscoLED TM.

E2K-F. Flat Capacitive Sensor with a Thickness of Only 10 mm. Flat Proximity Sensor. Ordering Information. Sensors [Refer to Dimensions on page 4.

E3Z-G. Photoelectric Sensor with Grooved Design and Easy Settings. Grooved-type Photoelectric Sensor with Built-in Amplifier. Ordering Information

E2K-F. Flat Capacitive Sensor with a Thickness of Only 10 mm. Flat Proximity Sensor. Ordering Information. Sensors [Refer to Dimensions on page 4.

Tina 1A Blanking plug

Operating instructions. Switching amplifier DN0210 DN / / 2015

CC186 AND CC186/2 STAND-ALONE OR SYSTEM CLOCK

E2EY. A Proximity Sensor for Aluminum, Brass and Other Non-ferrous Metals. Iron Is Not Detected. Aluminum-detecting Proximity Sensor

LINE VOLTAGE TESTER CT101 USER S MANUAL. Please read this manual carefully and thoroughly before using this product.

Photoelectric Sensor

E2KQ-X. Fluororesin-coated Capacitive Sensor with Sensitivity Adjuster. Chemical-resistant Proximity Sensor. Ordering Information

Aluminum Excellent Performance, with Aluminum Chip Immunity! The indicator is visible from any direction.

Carefree-Security. Installation and programming instructions 1050A. Owner s Manual

QAL50 Series Analog Line Sensor

Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual

FTC-200 X-ray Tube Controller Users Manual

Split2.8 RDM. 2 input DMX/RDM Splitter. User guide

PD10. Pulse Divider Instructions PROUDLY MADE IN THE USA

Photoelectric Sensor

MTS-2000 USER S MANUAL

Shape Model Measurement range Model Straight 50 to 300 mm. Straight 70 to 800 mm

KBMG MULTI-SPEED BOARD

E2EZ-X2D1-N 2M E2EZ-X2D2-N 2M

Operating instructions. Speed monitor D / / 2014

212iL Rev. 1.1

WARRANTY & LIMITATION OF LIABILITY

Powered Roller Controller for DeviceNet

WARRANTY & LIMITATION OF LIABILITY

Installation Instructions for the ISSUE 3 RDS-DIN1 Series Single Channel Interface Module PK 80103

INSTALLATION INSTRUCTIONS

Reliable Detection Unaffected by PCB Holes or Notches. PCB Sensors. Ordering Information. Sensors [Refer to Dimensions on page 4.

PLCADD1616 User Guide 3/29/10. Overview

Digital Lighting Systems, Inc.

E2EC. Subminiature Sensors with Long-distance Detection. Cable Amplifier Proximity Sensor. Ordering Information

MICRO SWITCH Sealed Subminiature Basic Switches. ZW Series. Datasheet

SMART Position Sensor, 100 and 180 Arc Configurations

MAXIMA+ Series Rotary Level Indicator

LBO-H2 Series DIRECT PLUGGABLE LINKBRIDE TM FIBER OPTIC HDMI 2.0 TRANSMISSION SYSTEM

Grundfos MAGNA, GENI Module

Ordering Information. I/O Relay G7T. Model Number Legend Slim-styled I/O Relay Saves Space in Panel

Proliphix EPA-60 Installation Guide

MAXIMA + Series ROTARY LEVEL CONTROL

Operating Instructions. Power Supply & Latching Relay For Switches Model: RL manual_rl-6000_1016

Owner s Manual. TSD-DCPDV DC Power Distribution with Fixed & Variable Outputs. TSD-DCPDV DC Power Distribution. AtlasSound.com

E2K-X4ME1 2M E2K-X4ME2 2M

PRODUCT CONTENTS... 3 II. REQUIRED MATERIALS... 3 III. OVERVIEW... 3 IV. BENCH LAYOUT...

PIM-Mini Pulsed Current Source Operation Manual

onlinecomponents.com

Model SPDT Switch Module

TSD-DA28 2x8 Balanced Line Distribution Amplifier

INTERPRETER CONTROL UNIT MODEL PL ICU 2 2 (2 INPUTS 2 OUTPUTS) INSTRUCTION MANUAL Technical Data Warranty Information

Push-Pull and E-Stop Switches. Datasheet

PMDX-105. I/O Option Riser Board User s Manual. Document Revision: 1.1 Date: 7 September 2004 PCB Revision: PCB-443A

SLA Battery Capacity Analyzer

KXR20 Voltage Regulator

Name No. of I/O points Model Safety inputs: 12, test outputs: 4

RoscoLED Tape VariWhite Gaffer Kit

Model M140 Mini Solar Power Meter

87421/22A Power Supply. Operating and Service Manual

NPN output. 200 mm. Type Cable length Model Remarks

OPERATING MANUAL LOW-VOLTAGE DISCONNECT PANELS LVD400 & LVD600 SERIES

Installation Manual April Opticom Infrared System Model 560 Card Rack

Card Nest Universal 12 position card nest for all K-AB cards above and all other K-AB cards.

TSD-SEQ6 Sequencer Controller

MTP INSTRUCTION MANUAL

PMDX-105 Quad Isolator Board

PMDX-108-Output. 8-Channel Isolated Output Board for PC parallel port pins 2-9. User s Manual

SmartBoom PRO PHS-SB100-4F, PHS-SB100-5M, PHS-SB100-U, PHS-SB200-4F, PHS-SB200-5M, PHS-SB200-U. Operating Manual

Ordering Information. I/O Relay G7T. Model Number Legend Slim-styled I/O Relay Saves Space in Panel

P7TF-IS16/OS16/OS08. I/O classification I/O points Internal I/O common Rated voltage Model 12 VDC P7TF-IS16 DC12 24 VDC P7TF-IS16 DC24 For inputs

Long Sensing-distance Capacitive Separate Amplifier Proximity Sensor E2J-W10MA 1M E2J-W20MA 1M. E2J-JC4A Amplifier Unit

User's Guide. Programmable DC Power Supply 200 Watt (40 Volts / 5 Amps) Model Introduction

UVAX Protocol Node NT Teslights Hybrid Lighting Controls B-PLC Solution. Technical Manual, T0115 January 2015

Tempco Instruction Manual

E2EC. High-sensitivity DC 2-Wire Sensors and Subminiature Sensors with Long-distance Detection. Cable Amplifier Proximity Sensor. Ordering Information

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

to your Pocket PC? 3. Click new to connect

INTELLIGENT DOCKING STATION USERS MANUAL

Installation, Testing, and Operating Procedures 30 AMP PORTABLE AND PERMANENT SERIES GFCI SINGLE and MULTIPHASE

SECURE/NONSECURE LED SIGN USER MANUAL

Seven Channel Remote Control

SLM Series Slot Sensors

DX-C USER GUIDE

BACNet Gateway Option

CK3W-PD048 CSM_CK3W-PD048_DS_E_DITA_1_2

E3S-GS/VS. Both Red-light Models and Greenlight Models to Detect a Wide Variety of Colors. Small Spot/Mark Sensor with Built-in Amplifier

Instruction Manual for Video OSD Expander Document Version 1.4

I/O Expansion Box Installation & Operator s Instruction Manual

Portable. GL100 An eye on your mobile property. User Guide

Number of input channels

CI-1 and CI-8. Communications Interface Betsy Ross Drive Santa Clara, CA (408) FAX (408) P/N Rev.

Installation Instructions Model LFMWLT450, Class 1 Series AC-DC Power Supply

Transcription:

TM CarSense 303-L OPERATING INSTRUCTIONS LOGIC INTERFACE 4564 Johnston Parkway, Cleveland, Ohio 44128 P. 800 426 9912 F. 216 518 9884 Sales Inquiries: salessupport@emxinc.com Technical Support: technical@emxinc.com www.emxinc.com

Contents Cautions and Warnings 2 Product Overview 2 Specifications 3 Operation 3 Controls and Indicators 6 Connections 7 Troubleshooting 7 Installation 8 Ordering Information 8 CarSense 303-L Operating Instructions 1

Cautions and Warnings CE REQUIREMENT: Use CE rated power supply for CE compliance providing suppression as specified by EN61000-4-5. Not to be used in safety applications. IMPORTANT: This product is an accessory or part of a system. Always read and follow the manufacturer s instructions for the equipment before connecting this product. Comply with all applicable codes and safety regulations. Failure to do so may result in damage, injury, or death. WARNING: DO NOT INSTALL THE SENSOR DIRECTLY INTO HOT ASPHALT, see installation section WARNING: Always use photoelectric protection when using the CS303 as a closing detector on a parking arm operator to prevent accidental closing on a car. Product Overview The CarSense 303 Logic Interface (CS303-L) works with CarSense 303 Direct Burial (CS303-DB) or CarSense 303 Flat Pack (CS303-FP) magnetoresistive sensors. Once the sensors have been programmed using the CarSense 303 Controller (CS303-C-1), the sensors store the settings and can operate independent of the controller. The Logic Interface allows one or two sensors to be connected and provides 6 different logic functions and two sets of relay outputs, one form A and one form C. These functions include: AB Directional Logic Pulse on Entry Pulse on Exit Common Relay operation Discrete Relay operation Dual Relay operation For more information regarding these functions and how they work, see page 4 CarSense 303-L Operating Instructions 2

Specifications Specifications Power Indicator Detect Indicator Configuration Selector Outputs Maximum Output Ratings Operating Environment Housing Material Enclosure Power (see Cautions and Warnings) Operating Current (Standby/Detect) Supply Protection Circuitry Green LED 2x Red LEDs 10 position rotary switch Relay 1: SPDT (form C) Relay 2: SPST (form A) 1A @ 24 VDC/120 VAC -40 o C 82 o C (-40 o F 180 o F) 0 95% relative humidity ABS IP30 12-30 VDC or 24 VAC One sensor connected: 22/35mA Two sensors connected: 33/60mA Reverse polarity and fuse protected Dimensions 73mm (2.9 ) x 38mm (1.2 ) x 78mm (3.1 ) Weight 0.25 lbs. (113 g) Connector 11 pin male connector (JEDEC B11-88) NOTE: Refer to CarSense 303 Operating Instructions for operation and installation of controller and sensor. Operation Power Up Upon power up the detector initializes: all three LEDs will flash on, then off. The green LED indicates that the detector is powered and operational. Relay1 and Relay2 LEDs indicate when Relay1 or Relay2 is activated, respectively. Note that the sensor must be installed and programmed using a CS303-C-1 prior to connection to the CS303-L. The CS303-L only monitors the sensors NPN outputs and cannot be used to change operation settings in the sensor. Set the Configuration Selector Switch Presence detection is determined by the settings programmed to the CS303-DB / CS303-FP connected. Refer to the CS303 Operating Instructions when installing the sensor(s) (CS303- DB / CS303-FP) to determine sensor settings appropriate for your application. CarSense 303-L Operating Instructions 3

Rotary Switch Mode 0 Discrete Relays 1 AB Directional Logic 2 Pulse on Entry 3 Pulse on Exit 4 Dual Relays 5 Common Relay 6 9 Invalid Behavior Relay1: Active while Sensor1 is active Relay2: Active while Sensor2 is active Relay1: Activates when Sensor1 and then Sensor2 activates Relay2: Activates when Sensor2 and then Sensor1 activates Relay1: Active while Sensor1 is active Relay2: 500ms pulse when Sensor1 activates Relay1: Active while Sensor1 is active Relay2: 500ms pulse when Sensor1 deactivates Relay1: Active while Sensor1 is active Relay2: Active while Sensor1 is active Relay1: Active while Sensor1 or Sensor2 is active Relay2: 500ms pulse when Sensor1 or Sensor 2 activate Relay1: Inactive Relay2: Inactive Discrete Relays While operating in Discrete Relays mode, Relay1 will activate and remain active while a vehicle is detected by Sensor1. Relay2 will activate and remain active while a vehicle is detected by Sensor2. AB Directional Logic AB Directional Logic mode is capable of determining the direction of travel of a vehicle using two sensors. Two sensors are installed in the direction of travel to provide input. If a vehicle is detected by Sensor1 and then Sensor2, Relay1 will activate and remain active while the vehicle is detected by Sensor2. If a vehicle is detected by Sensor2 and then Sensor1, Relay2 will activate and remain active while the vehicle is detected by Sensor1. When using the AB Directional Logic function, the sensors should be installed 1 meter (40 ) apart. Pulse on Entry Pulse on Entry provides mode presence (Relay1) and pulse (Relay2) outputs. When a vehicle is detected by Sensor1, Relay1 will activate and remain active while the vehicle is present, Relay2 will activate for 500ms and then remain inactive. Pulse on Exit Pulse on Exit mode provides presence (Relay1) and pulse (Relay2) outputs. When a vehicle is detected by Sensor1, Relay1 will activate and remain active while the vehicle is present, CarSense 303-L Operating Instructions 4

Relay2 will be inactivate until the vehicle is undetected, then Relay2 will activate for 500ms and then deactivate. Dual Relays Dual Relays mode allows for the operation of both Relay1 and Relay2 by Sensor1. While a vehicle is detected by Sensor1, both Relay1 and Relay2 will be active. Common Relay Common Relay mode allows for the operation of Relay1 and Relay2 by both Sensor1 and Sensor2. When a vehicle is detected by either Sensor1 or Sensor2, Relay1 will remain active while the vehicle is detected, Relay2 will activate for 500ms and then remain inactive. Invalid While the rotary switch is set to positions 6, 7, 8, or 9, the relays will remain inactive and all three LEDs on the unit will flash on and off once per second. CarSense 303-L Operating Instructions 5

Controls and Indicators 9 8 0 1 2 CONFIGURATION SELECTOR Function Position 0 9 Discrete Relays 0 AB Directional Logic 1 Pulse on Entry 2 Pulse on Exit 3 Dual Relays 4 Common Relay 5 Invalid 6 9 POWER RELAY 1 Power On/Off 7 6 5 4 3 Relay 1 On/Off POWER RELAY 2 Relay 2 On/Off RELAY 1 RELAY 2 CarSense 303-L Operating Instructions 6

Connections Pin Description Sensor #1 wire Sensor #2 wire 1 Power (12 24 VDC/VAC) - - 2 Power (12 24 VDC/VAC) - - 3 Relay2 NO - - 4 Relay1 NC - - 5 Relay1 COM - - 6 Relay1 NO - - 7 Sensor2 Input - White 8 Sensor1 Input White - 9 Relay2 COM - - 10 Sensors Power ( ) Blue Blue 11 Sensors Power ( + ) Brown Brown NOTES: 1) Refer to Operator Instruction for power and relay/control connections 2) Protect RED and GREEN wires from the sensor using electrical tape or other suitable electrical insulation Troubleshooting Symptom Possible Cause Solution All LEDs flash, one second cycle Red LED flashes, relay clicks, unstable Green and Red LEDs flash simultaneously Invalid rotary switch selection Poor connection for Sensor1 or Sensor2 Insufficient supply voltage Set rotary switch to a valid setting (0-5) Check and fix connection If only one sensor is used, set rotary switch to a valid position for 1 sensor Make sure the power supply is working correctly and properly rated according to connections table (see above) CarSense 303-L Operating Instructions 7

Installation 1. Refer to CarSense 303 Operating instructions for installation and set-up of the sensors for proper operation. All settings are stored in the sensors for stand-alone operation. 2. CS303-L monitors the NPN outputs from the sensors and does not provide the ability to change sensor (CS303-DB / CS303-FP) settings. 3. When using the AB Directional Logic function, the sensors should be installed 1 meter (40 ) apart in the axis of travel. 4. When wiring the sensors to the CS303-L: a. The brown wire from both sensors goes to pin 11 on the CS303-L b. The blue wire from both sensors goes to pin 10 on the CS303-L c. The white wire from one sensor goes to pin 8 (Sensor1 Input) on the CS303-L d. The white wire from the other sensor goes to pin 7 (Sensor2 Input) on the CS303-L e. Protect RED and GREEN wires from the sensor using electrical tape or other suitable electrical insulation Ordering Information CS303-L CarSense 303 Logic Interface CarSense 303-L Operating Instructions 8

Warranty EMX Industries Incorporated warrants all products to be free of defects in materials and workmanship for a period of two years under normal use and service from the date of sale to our customer. This warranty does not cover normal wear and tear, abuse, misuse, overloading, altered products, damage caused by incorrect connections, lightning damage, or use other than intended design. There is no warranty of merchantability. There are no warranties expressed or implied or any affirmation of fact or representation except as set forth herein. EMX Industries Inc. sole responsibility and liability, and the purchaser s exclusive remedy shall be limited to the repair or replacement at EMX Industries option of a part or parts found not conforming to the warranty. In no event shall EMX Industries Inc. be liable for damages, including but not limited to damages resulting from non-conformity, defect in material or workmanship. Effective date: January 1 st, 2002 CarSense 303-L Operating Instructions 9

4564 Johnston Parkway Cleveland, Ohio 44128 United States of America www.emxinc.com Technical Support: (216) 834-0761 technical@emxinc.com Sales: (216) 518-9888 Fax: (216) 518-9884 salessupport@emxinc.com CarSense 303-L Operating Instructions 10