Cable Routing Procedures for Dell PowerEdge R630 Systems

Similar documents
Cable Routing Procedures for Dell PowerEdge T320 & T420 Systems

Cable Routing Procedures for Dell PowerEdge T710 Systems

Cable Routing Procedures for Dell PowerEdge FX2/FX2s Systems

2U, 4U, and 7U Systems

Vertiv Local Rack Access 18.5" LED LCD Console

G12/G12x USER S MANUAL

TABLE OF CONTENTS SECTION 1 TABLETOP CONFIGURATION SECTION 2 TABLETOP CONFIGURATION ACCESSORIES SECTION 3 SLIDE CONFIGURATION

Mounting and Cable Routing Procedures for Dell Digital KVM s (1082DS, 2162DS, 4322DS)

Rack Installation Instructions

MECHANICAL AND THERMAL CONSIDERATIONS FOR RACK DEPLOYMENT OF THE DELL POWEREDGE M-SERIES. One Dell Way Round Rock, Texas

IBM. Rack Installation Instructions

Rack Installation Instructions

Rack Installation Instructions

Rack Installation Instructions

Dell EMC Enterprise Systems Rail Sizing and Rack Compatibility Matrix

Instructions for SVC-KIT-0020

Rack Installation Guide

7403 K321. Display Wall Mount. Kit Instructions. Issue A

Dell XPS 14z Owner s Manual

Install the Cisco SNS 3415 and Cisco SNS 3495 Hardware Appliances, page 1

Wall Mounted Building Entrance Enclosure Instructions

TDM To MiniMech conversion ProceDure

Cisco TelePresence VX Clinical Assistant TM

CMA Installation Guide

HD Flex Zero RU Cassette Holder and Bracket

Panduit PreConfigured Industrial Distribution Frame (IDF) Installation Instructions Part Numbers ZDF48-RA and ZDF48-EA ZDF48-6RA and ZDF48-6EA

FreeNAS Mini and Mini XL Network Upgrade Kit

Removing and Replacing Parts

DellEMC TM Enterprise Systems Rail Sizing and Rack Compatibility Matrix

Dell Inspiron N5110 Service Manual

Using Dell Repository Manager to Find Newer Updates from the Dell Online Repository

Agilent N2916B 6000 and 5000 Series Oscilloscope Rack Mount Kit

Replacement Instructions. Backplane PCA for the HP Router 650

System Storage EXP3000 Rack Installation Instructions

Heat Containment System (HCS)

Print Mechanism Maintenance Kit

The SC812/SC812L Chassis Series Installation Guide

IBM Systems. Quick start guide for IBM System p5 505 ( )

Eaton Heat Containment System (HCS) Installation Guide

InfraStruXure Central Standard/Enterprise Installation/Start-Up Service Procedure

Dell Latitude C800 Service Manual

Dell XPS L702X Service Manual

Replacement Instructions

Panzura Freedom Filer Installation Guide

Peel/Rewind Upgrade Kit

PC9/P9 CPU Card Replacement

Quick Start. This document describes how to install the Juniper Networks PTX5000 Packet Transport

E1135C PDU and Pod Upgrade Procedure

Assembly Instructions

Accelerating storage performance in the PowerEdge FX2 converged architecture modular chassis

Thank you for purchasing this Factory Service Manual CD/DVD from servicemanuals4u.com.

Eaton LCD Lift Flat Panel Display System. Installation Guide

A Comparative Study of Microsoft Exchange 2010 on Dell PowerEdge R720xd with Exchange 2007 on Dell PowerEdge R510

and Network Interface Modules Installation Instructions

Phase Loss Protection Upgrade. Phase Loss Protection Upgrade. In this bulletin:

Upgrading a 2U CHP to an i7 Quad Core SBC

SCv360 Expansion Enclosure

Megatouch FORCE Monitor Chassis Board Replacement

Installing the Server into a Rack

Dell OptiPlex SFF AIO Stand. User s Guide. Model: IKAIO-01 1 /13

This Datasheet for the IC697CHS790. Rack, 9 Slots, Rear Mount.

Rack Mount Cabinet with Fiber Mgmt System, accepts up to 3 Adapter Plates. Rack Mount Cabinet with Fiber Mgmt System, accepts up to 6 Adapter Plates

Replacing the Power Supply

Privileged Access Appliance Hardware Installation

3 Angled Connector Housing (MC) Installation

DIGITAL Server Rackmount Installation Guide

Installation Guide. HP J2437A 4-Port Token Ring Interface for the HP Router 650

Pretium Rack-mountable 1U Housing Hardware

The list below shows items not included with a SmartVDI-110 Server. Monitors Ethernet cables (copper) Fiber optic cables Keyboard and mouse

Fiber Management Tray (FMT) User Manual

Introduction to the CRS Back-to-Back System

Remote Support Appliance Installation

Outdoor PTZ. Mounting on the Ceiling Using Pendant Mount. Installation Guide. For Models: I93, I94, I95, I96, KCM /12/03

EMC 10/4 "CE" Mechanical Upgrade Procedure

Oracle <Insert Picture Here>

Dell Latitude V710/V740 Service Manual

Dell SC460 Expansion Enclosure Getting Started Guide

TDM-100/150 TO NMD-50 CONVERSION PROCEDURES RL5000

Agilent N2739A 1000 Series Oscilloscope Rack Mount Kit

SYSTIMAX 360 PATCHMAX Modular Panel Instructions

Installing IDS-4235 and IDS-4250

Gateway Profile 4 service guide

M1032W Engineering Workstation. The list below shows components included in an M1032W Engineering Workstation container.

4-Post and Universal Telco Frame (UTF) Rack Mount Kit Installation Instructions

OCM5 Splitters and Pass-Through Modules for CSX-3 Cabinets

2T-RMSMC System Management Station Kit Installation Guide

Wiwynn SV320 Maintenance User Manual

SGI InfiniteStorage 120

Installation Guide. Retrofit Kit for USB Ready Intraoral Systems

SCXI-1345 Shielded Cable

Treadmill Integrated LCD Screen Option. Cardio Theater Integrated Bracket Assembly Instructions

Quick start guide for i5 520 ( or )

Hardware Replacement Guide

Serial ATA Hot Swap Drive Cage Upgrade Kit for: Intel Server Chassis SC5200 Intel Server Chassis SC5250-E

LED Maintenance Instructions

120Ra-1 Pentium III Processor Installation Insert

P160 User s Manual Manuel de l utilisateur Anwenderhandbuch Manuale per l operatore Manual del usuario

NetShelter SX Cable Management. Organize large volumes of cables from networking switches and patch panels

MODULUS 21 Power Distribution Unit (PDU) Replacement. Overview A. Introduction

MacBook Pro 15" Core 2 Duo Models A1226 and A1260 SSD Dual Drive Installation

Transcription:

Cable Routing Procedures for Dell PowerEdge R630 Systems This Dell Technical White Paper explains the best practices for routing and securing the cables exiting the back of the R630 systems. Rail Solutions Engineering July 2014 1

This document is for informational purposes only and may contain typographical errors and technical inaccuracies. The content is provided as is, without express or implied warranties of any kind. The illustrations in this document do not represent a specific system. 2014 Dell Inc. All rights reserved. Dell and its affiliates cannot be responsible for errors or omissions in typography or photography. Dell, the Dell logo, and PowerEdge are trademarks of Dell Inc. Other trademarks and trade names may be used in this document to refer to either the entities claiming the marks and names or their products. Dell disclaims proprietary interest in the marks and names of others. July 2014 Rev 1.0 2

Contents Introduction... 4 Section 1: Cabling a PowerEdge R630 with a CMA... 4 1.1. Connecting the cables to the system... 4 1.2. Routing the power cables through the strain reliefs... 4 1.3. Installing the CMA... 5 Section 2: Replacing a power supply on a PowerEdge R630 system with a CMA... 8 2.1. Replacing a power supply with a left-side mounted CMA... 8 2.2. Replacing a power supply with a right-side mounted CMA... 8 Section 3: Cabling a PowerEdge R630 system on sliding rails without a CMA... 10 3.1. Routing the cables... 10 3.2. Removing the outer CMA brackets for shallow racks... 10 Section 4: Cabling a PowerEdge R630 system installed on static rails... 11 Figures Figure 1. System with cables installed... 4 Figure 2. Routing power cables through the strain reliefs... 5 Figure 3. Attaching the inner CMA attachment bracket... 5 Figure 4. Routing the cables through the CMA... 6 Figure 5. Left-side mounted CMA installation (preferred)... 7 Figure 6. Right-side mounted CMA installation (CMA shown in service position)... 7 Figure 7. Disconnecting the CMA attachment housings... 9 Figure 8. Replacing the outer power supply... 9 Figure 9. Cable routing without a CMA... 10 Figure 10. Removing the outer CMA brackets for shallow racks... 10 Figure 11. Cabling a system installed in static rails... 11 3

Introduction This white paper covers recommended cable routing procedures for the Dell PowerEdge R630 system installed in 19 rack enclosures. If you are using the optional cable management arm (CMA), following these procedures will allow you to extend the system from the rack for service without powering down or disconnecting the cables. If you are not using the CMA, following these procedures will ensure secure attachment and strain relief of the cables behind the system. For guidelines on how to route cables within the rack, refer to the Dell Best Practices Guide for Rack Enclosure white paper. For additional details regarding potential interferences between the CMA and rear-mount power distribution units (PDUs) in Dell racks as well as general information about third party rack compatibility, refer to the Dell Enterprise Systems Rail Sizing and Rack Compatibility Matrix located at http://content.dell.com/us/en/enterprise/d/business~solutions~engineeringdocs~en/documents~rail-rack-matrix.pdf.aspx. Section 1: Cabling a PowerEdge R630 with a CMA This section details how to cable the PowerEdge R630 systems on sliding rails using a CMA. If you are cabling the system without the optional CMA, refer to Section 3. Follow the instructions contained in the Rack Installation Instructions in the sliding rail kit to install the server into the rack. Once installed, use these instructions to install the cables. All illustrations in the following sections were created using a PowerEdge R630 system (10 HDD version). NOTE: PowerEdge R630 systems are backward compatible with the PowerEdge R620 rails and CMA. 1.1. Connecting the cables to the system Attach the CMA tray to the back of the rails as described in the CMA Installation Instructions provided in the CMA kit. Connect all applicable cables to the rear of the system and verify that all connections are secure. See Figure 1. Figure 1. System with cables installed 1.2. Routing the power cables through the strain reliefs 4

After you have installed the tray and cables, route the power cables through the strain reliefs located on the power supply handles as shown in Figure 2. Figure 2. Routing power cables through the strain reliefs 1.3. Installing the CMA The CMA can be installed on either the rear right or rear left side of the rails as described in the CMA Installation Instructions. Mounting the CMA on the side that is opposite of the power supplies (left-side mount) is recommended; otherwise, the CMA must be partially disconnected in order to remove the outer power supply. Refer to Section 2 for details on power supply replacement. NOTE: If you are installing fiber-optic cables in the CMA, a cable bend radius of at least 1 inch must be maintained throughout the length of the cable. It is recommended that fiber-optic cables be routed on the exterior of the cable bundle to increase the bend radius of the fiber-optic cables through the CMA. Additionally, a large amount of slack at the entrance and exit of the CMA is recommended. 1.3.1. Installing the inner CMA attachment bracket As described in the CMA Installation Instructions, locate and attach the appropriate inner CMA attachment bracket based on which side you wish to mount the CMA. Use the bracket marked A for mounting the CMA on the left side, and the bracket marked B for mounting on the right side. See Figure 3. Figure 3. Attaching the inner CMA attachment bracket 5

1.3.2. Left-side mounting instructions 1. Install the CMA on the rear left side of the rails by attaching both CMA housings to the attachment brackets on the rails. 2. Route the cables through the CMA while avoiding twisting the cables. Use the hook-and-loop straps on the CMA to secure the cables. 3. If the cable bundle includes a keyboard, video, and mouse system interface pod (KVM SIP), it can be placed inside the CMA basket for light to medium cable loads. If the KVM SIP will not fit inside the basket with the other cables, attach it to the exterior of the front basket as shown in Figure 4. Figure 4. Routing the cables through the CMA NOTE: Do not store excess cable slack inside the CMA. The cables may protrude through the CMA, thus causing binding and potentially damaging the cables. Cables entering the CMA should have a small amount of slack to avoid cable strain when the CMA is extended. KVM SIP can be attached to the outside of the CMA basket if necessary using the hook-and-loop straps provided on the CMA. 4. Once you have routed all of the cables through the CMA, dress the cable slack between the back of the system and the entrance of the CMA using the tie wraps provided in the CMA kit. 5. Clip off the excess length of material from the tie wraps. Make sure that the heads of the tie wraps are positioned so as to avoid interference with adjacent systems. Return the CMA to the closed (retracted) position. 6. Extend the system out of the rack to verify that there is sufficient slack in the cables on both ends of the CMA. This step is particularly important for the 10 HDD version of the R630 due to the fact that the CMA and tray translate forward approximately 50 mm before the CMA begins extending. See Figure 5 for an example of a completed left-side mounted CMA installation. 6

Figure 5. Left-side mounted CMA installation (preferred) 1.3.3. Right-side mounting instructions Install the CMA on the rear right side of the rails by attaching both CMA housings to the attachment brackets on the rails. The remaining steps are the same as for left-side mounting as described in Section 1.3.2. See Figure 6 for an example of a completed right-side mounted CMA installation. Figure 6. Right-side mounted CMA installation (CMA shown in service position) 7

Section 2: Replacing a power supply on a PowerEdge R630 system with a CMA 2.1. Replacing a power supply with a left-side mounted CMA 1. Swing the CMA to its service position as described in the CMA Installation Instructions provided with the CMA kit. 2. Remove the tray from underneath the CMA as described in the CMA Installation Instructions. 3. Disengage the strain relief and disconnect the power cord from the power supply. 4. Replace the power supply. 5. Plug in the power cord, re-engage the strain relief, replace the CMA support tray, and return the CMA to the closed (retracted) position. 2.2. Replacing a power supply with a right-side mounted CMA 1. If the innermost power supply must be replaced, then follow the steps described in Section 2.1. If the outermost power supply must be replaced, follow the steps described below. 2. Swing the CMA to its service position as described in the CMA Installation Instructions provided with the CMA kit. 3. Remove the tray from underneath the CMA as described in the CMA Installation Instructions. 4. Disengage the strain relief and disconnect the power cord from the power supply. 5. Disconnect both CMA attachment housings from the brackets on the rails as shown in Figure 7. 6. Detach the inner CMA bracket from the rail by pushing on the end of the lock spring and lifting the bracket up and to the left until it clears the standoffs on the rail. 7. While supporting the CMA with one hand, remove and replace the outer power supply with the other hand as shown in Figure 8. 8. Reinstall the inner CMA bracket to the rail and reconnect the CMA to the brackets. 9. Plug in the power cord, re-engage the strain relief, replace the CMA support tray, and return the CMA to the closed (retracted) position. 8

Figure 7. Disconnecting the CMA attachment housings Figure 8. Replacing the outer power supply 9

Section 3: Cabling a PowerEdge R630 system on sliding rails without a CMA NOTE: The CMA for Dell PowerEdge R630 is optional. Without the CMA installed, the system must be powered down and all cables disconnected before it can be extended out of the rack. 3.1. Routing the cables 1. Connect all applicable cables to the rear of the system and verify that all connections are secure. 2. Using the hook-and-loop straps supplied with the rail kit, bundle the cables and secure them to either the left or right outer CMA attachment bracket as described in the Rack Installation Instructions. See Figure 9 for an example of data cables secured to the left outer CMA bracket and power cables secured to the right outer CMA bracket (as viewed from the rear of the system). Figure 9. Cable routing without a CMA 3.2. Removing the outer CMA brackets for shallow racks If you are installing the system into a shallow rack (less than 1 meter deep) and you will not be installing a CMA, the outer CMA brackets may be removed from the sliding rails if necessary in order to allow the rails to fit properly into the rack. Remove the brackets by using a #2 Phillips screwdriver to remove the screws that secure the brackets to the rails as shown in Figure 10. Use the hook-and-loop straps supplied with the rail kit to secure the cables to the rack frame if desired. Figure 10. Removing the outer CMA brackets for shallow racks 10

Section 4: Cabling a PowerEdge R630 system installed on static rails NOTE: The CMA is compatible only with the sliding rails, not the static rails. 1. Follow the instructions contained in the Rack Installation Instructions found in the static rail kit to install the server into a two-post or four-post rack. 2. Install the hook-and-loop straps provided in the rail kit through the slots in the rear brackets of the rails as described in the Rack Installation Instructions. If the slots in the rails are not accessible due to the depth of the system and/or the spacing of the rack mounting flanges, install the hookand-loop straps onto the rack frame as shown in Figure 11. 3. Connect all applicable cables to the rear of the system and verify that all connections are secure. 4. Using the hook-and-loop straps, bundle the cables and secure them to either the left rail or right rail as described in the Rack Installation Instructions. See Figure 11 for an example of data cables secured to the left rail and power cables secured to the right rail (as viewed from the rear of the system). Figure 11. Cabling a system installed in static rails Install the hook-and-loop straps onto the rack frame if the slots in the rails are not accessible 11