We measure it. Everything under control: With testo Saveris TM, measurement data are under control everywhere.

Similar documents
Measurement data monitoring system

Measurement data monitoring system

Measurement data monitoring system

Measurement data monitoring system

Measurement data monitoring system

We measure it. Automated and uninterrupted measurement data recording. Flexible system set-up with wireless or Ethernet probes in many probe versions

Measurement data monitoring system testo Saveris.

Measure, document, issue alarms. Automated with testo Saveris. Committing to the future

Measurement data monitoring system testo Saveris.

Measurement data monitoring system testo Saveris.

WiFi data logger system

WiFi data logger system

WiFi data logger system

Next Generation! We measure it. With the professional Testo data loggers, a new age begins for you. Logger series testo 174. Logger series testo 175

All measurement data. Always available. On any device. The WiFi data logger system testo Saveris 2. Analysis & Reports. Graphical presentation

Next Generation! Committing to the future. With the professional Testo data loggers, a new age begins for you. Logger series testo 174

Next Generation! We measure it. With the professional Testo data loggers, a new age begins for you. Logger series testo 174. Logger series testo 175

Miles Ahead of the Competition!

Measurement Solutions for Climate Applications in Industry

F %RH. %rf CO 2. g/m 3. inch H₂O. hpa. Measure. Record. Monitor. Choose the right data loggers for your application now.

VAC analysis measuring instrument

Infrared temperature measuring instrument

The industrial humidity transmitter

Humidity transmitter for critical climate applications

Infrared temperature measuring instrument

Infrared temperature measuring instrument

Log, Save, Print and Analyse Data On-Site Quickly and Efficiently

The industrial humidity transmitter

Differential pressure

Differential pressure measuring instrument

testostor 171 Instruction manual

Differential pressure measuring instrument

testo 735 Compact Pro Series NEW! The working standard for temperature measurements

Differential pressure measuring instrument

Infrared Temperature Measuring Instrument

testo Probe series testo 661x The industrial humidity transmitter We measure it. SPECIFICATIONS testo Probe series testo 661x

Differential pressure measuring instrument

testo 175 Data loggers Instruction manual

RMS WIRELESS MINI LOGGER

Differential pressure measuring instrument

EBI 3x0 USB Data Loggers

EBI 3x0 USB Data Loggers

testo 176 Data loggers

EBI 3x0 USB Data Loggers

EBI 25 Wireless Data Logger System

EBI 3x0 USB Data Loggers

DATA LOGGERS Reliable solutions for monitoring your processes

Data logger systems from ROTRONIC

Measuring Instruments for Humidity

TEMPERATURE HUMIDITY PRESSURE ALL FOR YOUR WIRELESS MEASUREMENT AND DATA COLLECTION FROM ONE PROVIDER!

RMS Mini Wireless Data Logger

x testo 400 The reference measuring instrument for A/C and ventilation systems Additional information at

testo 176 Datenlogger testo 176 Data loggers testo 176 Enregistreur de données Bedienungsanleitung Instruction manual Mode d'emploi

PI 500 Hand-held instrument for industry

testo 175 Instruction manual

DataNet Solution. Wireless intelligent logging network. Sense it. Manage it. H E

CLEAN ROOM PANEL - CRP5

RMS Mini Wireless Data Logger

The flue gas analyzer with Longlife sensors and integrated draught/gas zeroing

Precision Hand-held Thermometer

Multi-functional precision thermometer CTR3000

testo LL Flue gas analysis with increased convenience and reliabilty

Light intensity measuring instrument

testo Probe series testo 661x The industrial humidity transmitter Committing to the future

testo 875 and testo 881 for professional building thermography

Data Logging Solutions from Lascar Electronics

Avoid experiments in monitoring important parameters. Measuring instruments and solutions for the pharmaceutical, medical and healthcare industries

EE310. High-End Humidity and Temperature Transmitter for Demanding Process Control. Typical applications. Features EE310 EE310

Temperature Data Logger EBI 100

Hand-Held Thermometer Model CTH 6200

EE310. High-End Humidity and Temperature Transmitter for Demanding Process Control. Typical applications. Features EE310 EE310

PRODUCT GUIDE. Your Data, Anytime, Anywhere.

Dew point. Dew point set DS 400. Special features: Dew point set DS 400. Technical data DS 400. Technical data FA 410

Committing to the future. Measurement Solutions for Production, Quality Control and Maintenance

BIOMERIEUX PERFORMANCE SOLUTIONS Quality & Compliance Services. How will Labguard watch over your quality?

IDS 400 mobile Affordable, mobile chart recorder. Flow Pressure / Vacuum Temperature Moisture / Dew point Optional third-party sensors

1523/1524. Reference Thermometers. Measure, graph and record three sensor types with one tool

TRANSMITTERS. HygroFlex & HygroClip-EX. Applications. Highlights

DMT345 and DMT346 Dewpoint Transmitters

EE360. High-End Moisture in Oil Transmitter. Typical applications. Features EE360 EE360. (+34)

Class 220 KISTOCK. KT 220, KH 220 and KTT 220

DataSuite User Guide. Supporting: DataNet, DaqLink, MicroLite, MicroLogPRO II, PicoLite. FDA Title 21 CFR Part 11 Compliant.

testo 6740 Instruction manual

KISTOCK DATALOGGER KT 320 / KTT 320

testo 184 Data logger Instruction manual

Measuring Instruments for Humidity

PTU300 Combined Pressure, Humidity and Temperature Transmitter

Chart recorder. DS 400 mobile Affordable, mobile chart recorder. Flow Pressure / Vacuum Temperature Moisture / Dew point Optional third-party sensors

JUMO PINOS L01. Calorimetric flow sensor. Brief description. Special features. Customer benefits. Data Sheet

Technical Information Liquiline To Go CYM290 and Liquiline To Go Ex CYM291

Refrigerated incubators with forced convection

Datasheet Thermal imager

Multi-Function Measuring Instruments

Specification for temperature sensor calibration setup

HLX31 Series. Multifunctional Industrial Transmitter for Humidity / Temperature / Dew Point / Absolute Humidity... Model A. Model B.

Standard Operating Procedure for the Kaye Validator AVS System

Hand-held thermometer Model CTH7000

Compressed air quality meas. according to ISO 8573 Residual oil content - particles - moisture

Input for universal probe* Inputs for thermocouple probes

JUMO ecotrans ph 03 Microprocessor transmitter/ switching device for ph/redox voltage and temperature

Transcription:

We measure it. Everything under control: With testo Saveris TM, measurement data are under control everywhere.

Saveris testo Saveris TM : Easy, safe and efficient measurement data monitoring The data monitoring system testo Saveris measures the temperature and humidity values of sensitive goods and products in ambient as well as in process conditions. The easy-to-use measurement system delivers safety and savings in time and costs thanks to automated measurement data recording. The transfer of the data takes place by wireless and/or Ethernet connection to a base station. This documents and monitors all measurement data. If limit values are exceeded, a whole range of different alarm options, such as SMS/e-mail alarm or alarm relay is available. Remote alarms can even be given when the system is not connected to a running PC. 2

We measure it. In addition to this, transmitters of all measurement parameters with standard current/voltage interfaces can be integrated into the Saveris system. The integration of Testo transmitters as well as those of other manufacturers is possible. All recorded data are stored centrally in a software. At the same time, the Saveris software allows the extensive analysis and evaluation of all data gathered. 3

Saveris testo Saveris system overview Data monitoring for uninterrupted checks testo Saveris TM wireless probe Probe versions with internal and external temperature and humidity sensors allow the adaptation to every application. The radio probes are available with or without a display as an option. Current measurement data, the battery status and the quality of the radio link are shown on the display. testo Saveris TM router The radio link can be improved or lengthened in poor structural conditions by using a router. Several routers can of course be used in the testo Saveris system. At the same time, the serial switching of up to 3 routers V 2.0 offers highest flexibility in the wireless range. testo Saveris TM converter Through the connection of a converter to an Ethernet jack, the signal of a radio probe can be converted into an Ethernet signal. This combines the flexible connection of the radio probe with the use of the existing Ethernet even over long transmission paths. testo Saveris TM router V 2.0 testo Saveris TM converter V 2.0 Ethernet testo Saveris TM wireless probe testo Saveris TM analog coupler (Ethernet) testo Saveris TM analog coupler (wireless) Humidity transmitters testo Saveris TM analog coupler The two versions of the analog coupler (wireless / Ethernet) allow the inclusion of other measurement parameters into the testo Saveris monitoring system, by integrating all measurement transmitters with standarized current/voltage interfaces, e. g. 4 to 20 ma or 0 to 10 V. Humidity transmitters testo 6651/6681/6351/6381 Thanks to the integration of the humidity and differential pressure transmitters, measurement data monitoring is possible parallel to the control. This provides the solution for highest accuracy as well as for special applications (high humidity, trace humidity etc.) in compressed air, drying and air conditioning technology and in cleanroom applications. Find out more at www.testo.com/transmitter 4

We measure it. testo Saveris TM Base The base is the heart of testo Saveris and can save 40,000 readings per measurement channel independently of the PC. This corresponds to around one year of memory capacity at a measuring rate of 15 minutes. The system data and alarms are visible via the display of the Saveris base. testo Saveris TM software The testo Saveris software offers simple operation and an intuitive user interface. The Saveris software is available in three different versions: as the basic version SBE (Small Business Edition), the PROF (Professional) software version with diverse additional options, or as the CFR version. The CFR software fulfils the requirements of the FDA s 21 CFR Part 11 and is thus validatable. Ethernet USB or Ethernet testo Saveris TM Base Ethernet testo Saveris TM Ethernet probe testo Saveris TM Software testo Saveris TM Ethernet probe In addition to the radio probes, probes can be used that are directly connected to the Ethernet. The existing LAN infrastructure can be used through this. This allows the data transfer from the probe to the base, even over long distances. 5

Saveris Overview of testo Saveris TM application areas Monitoring the foodstuff cooling chain Compliance with predefined temperature values is a decisive factor for quality in food production and is important for complying with legal hygiene standards. testo Saveris automates not only the monitoring of the ambient and production temperatures during production and storage, but also of defined temperature limit values during transport. The installation of wireless probes in delivery vehicles makes the complicated wiring of the driver s cabin unnecessary. Alarms are issued whenever the limit values are exceeded. The measurement data and any occurring alarms are saved centrally in a database and are accessible at any time. testo Saveris conforms to the EN 12830 standard. 6

We measure it. Monitoring in production, quality assurance and storage in industry In industry, a number of quality data must be recorded and monitored in the production, quality assurance and storage of products. testo Saveris automates the documentation of these data and alarms when limit values are exceeded. Products and processes are thus guaranteed at a high level of quality. testo Saveris is ideal for use in the monitoring and documentation of ambient and temperature data in production areas, storerooms, refrigerators and climate cabinets. The most varied applications are optimally covered by testo Saveris radio probes and/or Ethernet probes. 7

Saveris Overview of testo Saveris TM application areas Monitoring of processes in the pharmaceutical industry In the pharmaceutical industry, high demands are placed on the recording and monitoring of quality parameters. Constant documentation and monitoring during the production and storage of temperature-sensitive products such as medicines, blood products or cell cultures has long been considered an absolute must. testo Saveris automates the central documentation of measurement data as well as the safe monitoring of refrigerated and deep-freeze rooms, incubators and climate cabinets. The comprehensive alarm management allows fast alarming if limit values are violated. Thanks to a combination of wireless and/or Ethernet probes, the system is optimum for many different applications in the pharmaceutical industry. It goes without saying that the data monitoring system testo Saveris meets the requirements of 21 CFR Part 11. 8

We measure it. Monitoring of the building climate When monitoring the building climate, stable ambient conditions are especially necessary in museums and archives in order to protect sensitive and valuable objects. testo Saveris automates the central recording of all climate data. By issuing alarms when limit values are exceeded, testo Saveris protects valuable inventory from undesired temperature or humidity influences at all times. The radio probe can be flexibly attached to locations without the effort of routing cables. Monitoring of processes in research and development, laboratories and hospitals Research and development areas as well as laboratories and hospitals are responsible for the recording of ambient and process data in order to monitor sensitive products or machines. testo Saveris carries out the central documentation and monitoring of the measurement series. testo Saveris thus guarantees the simple and ure monitoring of climate and process data in air conditioning chambers, refrigerators, drying chambers, test benches or blood banks. At the same time, the Saveris software allows the extensive analysis and evaluation of all measurement data gathered. 9

Saveris testo Saveris software 1 Installation made easy Connect Saveris base to mains. The probes can now be logged on at the base: They are switched on in series and automatically identified by the base. The Saveris base is connected to the PC via USB or Ethernet. The software is installed on the PC with help from the installation wizard. The system is ready for configuration: Probe name, limit values, measuring cycles and alarms can be adapted to the individual measuring tasks. 2 Clear and always up-to-date The measurement data can always be shown as a graphic or table. Various probes can be compiled into groups. Logical units by measurement task are thus formed. The measurement data view over days, weeks or months is freely definable. The integrated calendar offers practical assistance here. Daily report Cold storage house zone: Hourly mean values on 03.08.2007 Time C freezer 1 %RH cold room 1 C refrigerator C drinks C freezer 2 C freezer 3 C freezer 4 3 Automated documentation Form and time of the reporting are predefined once. The creation and saving of reports as a PDF file now takes place automatically in accordance with the set conditions. The files are therefore ready to be printed at any time. Total maximum value Total mean value Total minimum value 10

We measure it. Small Business Edition (SBE), Professional (PROF) and CFR version Now more flexible with Professional software 4 The PROF (Professional) software version offers interesting additional functions beyond the attractive standard functions of the basic version SBE, e.g.: Client-server concept: The measurement data can be monitored by various PCs integrated into the network. Photographs of machines or rooms can be saved as a picture. The respective measurement values are shown directly at the position of the probe in the room or at the machine in these. The link between the location and the measurement value is thus very easily visualized (fig. 4). A comprehensive alarm management offers the option of alarming more than two people at the same time or in succession. Depending on the day of the week or the time, it is possible to choose whether the alarm is given as an e-mail and/or an SMS. 21 C 48 %RH 41 C 22 %RH 26 C 38 %RH Validatable CFR software 5 The CFR software fulfils the requirements of the FDA s 21 CFR Part 11 and is thus validatable. Overview of software features SBE PROF CFR Diagrams / tables / Alarm overview / PDF reports Calendar management Presentation of probe groups Alarm dispatch (e-mail, SMS, relay) Comprehensive alarm management Automated update of measurement data ( Online mode ) Measurement data on background photo of measruement sites Integration in network (client-server) Allocation of access rights for stationary and mobile probe groups 21 CFR Part 11 compliant (validatable) Electronic signature Audit trail for tracing user activity Allocation of access rights on 3 user levels SBE software, incl. USB connecting cable base-pc 0572 0180 PROF software, incl. USB connecting cable base-pc 0572 0181 CFR software, incl. Ethernet connecting cable base-pc 0572 0182 11

Saveris testo Saveris Base The base is the heart of testo Saveris and can save 40,000 readings per measurement channel independently of the PC. The system data and alarms are visible via the display of the Saveris base. Display for showing alarms and system data Large data memory Issue of alarms via LED/relay SMS alarm (optional) Emergency battery integrated Up to 150 probes can be connected Connection option via USB or Ethernet Technical data Memory Dimensions Weight Protection class Housing material Radio frequency Power supply (absolutely necessary) Rech. batt. Oper. temp. Storage temp. Display Interfaces Connectable radio probe 40,000 values per channel (total max. 18.000.000 values) 225 x 150 x 49 mm approx. 1510 g IP42 Die-cast zinc/plastic 2.4 GHz 6.3 V DC mains unit; alternatively via 24 V AC/DC plug-in/screw terminals, power consumption 4 W Li-ion battery (for data back-up and for emergency SMS with failure of the power supply) -10 to +50 C -40 to +60 C graphical display, 4 control keys USB, radio, Ethernet max. 15 probes can be directly connected via radio interface, max. 150 total via radio / Router / Converter / Ethernet, max. 450 channels Alarm relay max. 1 A, max. 30 W, max. 60/25 V DC/AC, NC or NO contact GSM module 850/900/1800/1900 MHz not valid for Japan and South Korea Set up Table base and wall bracket included Firmware Version 2.X Ordering data 2.4 GHz Saveris base, radio frequency 868 MHz 0572 0220 Note on the radio frequencies 2.4 GHz: non EU countries 2.4 GHz Saveris base, radio frequency 868 MHz, GSM module integrated (for SMS alarm) 0572 0221 No mains units or antennas with magnetic base are contained in this ordering data. 12

We measure it. testo Saveris components: Router und Converter The radio link can be improved or lengthened in poor structural conditions by using a router. Several routers can of course be used in the testo Saveris system. At the same time, the serial switching of up to 3 routers V 2.0 offers highest flexibility in the wireless range. Through the connection of a converter to an Ethernet jack, the signal of a radio probe can be converted into an Ethernet signal. This combines the flexible connection of the radio probe with the use of the existing Ethernet even over long transmission paths. Radio Radio Radio Radio Ethernet Ethernet Saveris Router V 1.0 Saveris Router V 2.0 Saveris Converter V 1.0 Saveris Converter V 2.0 Use for Saveris Base Firmware Version V 1.X for Saveris Base Firmware Version V 2.X for Saveris Base Firmware Version V 1.X nonly for wireless probes Firmware Version 1.x for all Saveris Base Firmware versions only for wireless probes with Firmware Version V 2.X Dimensions Weight Power supply approx. 180 g 6.3 V DC mains unit; alternatively via 24 V AC/DC plug-in/screw terminals, power consumption approx. 85 x 100 x 38 mm approx. 190 g 6.3 V DC mains unit; alternatively via 24 V AC/DC plug-in/screw terminals, PoE, power consumption Oper. temp. Storage temp. Housing material Protection class Interfaces Connectable radio probe Router cascading Wall holder -20 to +50 C -40 to +60 C Plastic IP54 Radio Radio, Ethernet max. 5 max. 15 No Yes included 2.4 GHz Versions Saveris router, V 1.0,868 MHz, radio transmission medium 0572 0159 Saveris router, V 2.0,868 MHz, radio transmission medium 0572 0259 Saveris Cverter V 1.0, 868 MHz, converts the radio transmission medium to Ethernet 0572 0158 Saveris Cverter V 2.0, 868 MHz, converts the radio transmission medium to Ethernet 0572 0258 No mains units are contained in this ordering data. 13

Saveris testo Saveris components: Radio probe Probe versions with internal and external temperature sensors and with humidity sensors allow the adaptation to every application. The radio probes are available with or without a display as an option. Current measurement data, the battery status and the quality of the radio link are shown on the display. NTC internal 81 mm NTC internal 81 mm C / F TC external 81 mm TC external 81 mm Pt 100 external Internal sensor External probe Radio Probe type Measuring range Accuracy Resolution Probe type Measuring range (instrument) Accuracy (instrument) Resolution (instrument) Connection Saveris T1 Radio probe with internal NTC NTC -35 to +50 C ± 0.4 C (-25 to +50 C) ±0.8 C (remaining meas. range) 0.1 C Saveris T2 Radio probe with external probe connection and internal NTC, door contact NTC -35 to +50 C ± 0.4 C (-25 to +50 C) ±0.8 C (remaining meas. range) 0.1 C NTC -50 to +150 C ± 0.2 C (-25 to +70 C) ±0.4 C (remaining meas. range) 0.1 C NTC via Mini DIN socket, Door contact connection cable included in delivery (1.80 m) Saveris T3 2-channel radio probe with 2 external TC probe connections (TC characteristics can be selected) 0.1 C / TC Type S 1 C 2 TCs via TC socket, max. difference in potential 2 V Saveris Pt Radio probe with 1 external Pt100 probe connection TC Type K TC Type J Pt100-195 to +1350 C -100 to +750 C -200 to +600 C TC type T TC type S -200 to +400 C 0 to +1760 C ±0.5 C or 0.5% of reading) at +25 C ± 0.1 C (0 to +60 C) ±0.2 C (-100 to +200 C) ±0.5 C (remaining meas. range) 0.01 C 1 Pt100 via mini-din socket Dimensions (housing): Weight Battery life (Type: 4 x AA) Housing material Protection class Radio frequency Meas. cycle Memory Conformity with standards Oper. temp. Storage temp. Display (optional) Transmission distance Wall holder IP68 DIN EN 12830-35 to +50 C 80 x 85 x 38 mm approx. 240 g Battery life 3 years at +25 C; 3 years with Energizer L91 Photo lithium batteries for freezer applications Plastic IP54 2.4 GHz Standard 15 min, can be set from 1 min up to 24 h 6.000 readings per channel -40 to +55 C (incl. batteries) 2-line LCD; 7 segments with symbols approx. 100 m free field at a frequency of 2.4 GHz included -20 to +50 C IP68 Versions Version without display Saveris T1 0572 1250 * 2.4 GHz Version with display Saveris T1 D 0572 1260 * Saveris T2 0572 1251 * Saveris T2 D 0572 1261 * Saveris T3 0572 9252 * Saveris T3 D 0572 9262 * Saveris Pt 0572 7251 * Saveris Pt D 0572 7261 * The AA alkali manganese mignon batteries (0515 0414) are contained in this ordering data (excepting analog coupler). Saveris probes are delivered with a calibration protocol of the works adjustment data. Calibration certificates must be ordered separately. * The Saveris Converter V 2.0 (order no. 0572 0258) is required for integration of Saveris wireless probes into systems with Base firmware V 1.X For more information please contact your Testo partner. 14

We measure it. testo Saveris components: Radio probe % RH NTC C / F and %RH % RH NTC % RH NTC ma V ma and V external internal external internal Radio Saveris H2 D Humidity radio probe Saveris H3 Humidity radio probe Saveris H4 D Radio probe with 1 external humidity probe connection Saveris U1 Radio probe with current/voltage input Internal sensor Probe type Measuring range Accuracy NTC Resolution 0.1 C Probe type NTC Humidity sensor Meas. range (instrument) -20 to +50 C 0 to +100 %RH 2) Accuracy (instrument) ± 0.5 C to 90 %RH: ±2 %RH at +25 C > 90 %RH: ±3 %RH at +25 C ±0,03 %RH/K ± 1 Digit Resolution (instrument) 0.1 C 0,1%/0.1 Ctd Connection fixed stump probe External probe -20 to +50 C ± 0.5 C Humidity sensor 0-100 %RH ±3 %RH at +25 C ±0,03 %RH/K ±1 Digit 0.1 % / 0.1 Ctd NTC -20 to +70 Humidity sensor 0 to +100 %RH 2) ± 0.2 C see probes 0.1 C 0,1%/0.1 Ctd 1 x external humidity probe Mini DIN socket 1 channel: Current/voltage input 2-wire: 4... 20 ma 4-wire: 0/4... 20 ma, 0 to 1/5/10 V, load: max. 160 Ω at 24 V DC Current ±0.03 ma / 0.75 μa Voltage 0 to 1 V ±1.5 mv/39 μv Voltage 0 to 5 V ±7.5 mv / 0.17 mv Voltage 0 to 10 V ±15 mv / 0,34 mv ±0.02% of m.v./k deviating from nominal temperature 22 C 2/4-wire current/voltage input Service interface Mini DIN for adjustment Dimensions (housing): Weight Battery life (Type: 4 x AA) Housing material Protection class Radio frequency Meas. cycle Memory Oper. temp. Storage temp. Display (optional) Transmission distance Wall holder 85 x 100 x 38 mm approx. 256 g IP54 80 x 85 x 38 mm approx. 245 g Batery life 3 years at +25 C; 3 years with Energizer L91 Photo lithium batteries for freezer applications Plastic IP42 2.4 GHz Standard 15 min, can be set from 1 min up to 24 h 6.000 readings per channel -20 to +50 C -40 to +55 C (incl. batteries) 2-line LCD; 7 segments with symbols approx. 100 m free field at a frequency of 2.4 GHz included approx. 85 x 100 x 38 mm approx. 240 g Supply: Mains unit 6.3 V DC, 20 to 30 V DC max. 25 V AC IP54 (no display) Versions Version without display 2.4 GHz Version with display Saveris H2 D 0572 6262 * Saveris H3 0572 6250 * Saveris H3 D 0572 6260 * Saveris H4 D 0572 6264 * Saveris U1 0572 3250 * The AA alkali manganese mignon batteries (0515 0414) are contained in this ordering data (excepting analog coupler). Saveris probes are delivered with a calibration protocol of the works adjustment data. Calibration certificates must be ordered separately. 1) Not for condensing atmosphere. For continuous applications in high humidity (>80 %RH at 30 C for >12 h, >60 %RH at >30 C for >12h), please contact us via www.testo.com. * The Saveris Converter V 2.0 (order no. 0572 0218) is required for integration of Saveris wireless probes into systems with Base firmware V 1.X For more information please contact your Testo partner. 15

Saveris testo Saveris components: Ethernet probes The existing LAN infrastructure can be used through the Ethernet probe. This allows the data transfer from the probe to the base, even over long distances. Ethernet probes have a display. NTC external TC external C Pt 100 external Ethernet Saveris T1 E Saveris T4 E Saveris Pt E Ethernet probe with external NTC probe connection 4-channel Ethernet probe with 4 external TC probe connections Ethernet probe with external Pt100 probe connection External probe Probe type Measuring range (instrument) Accuracy (instrument) Resolution (instrument) Connection Dimensions (housing): Weight Supply Buffer battery Housing material Protection class Meas. cycle Memory Oper. temp. Storage temp. NTC -50 to +150 C ± 0.2 C (-25 to +70 C) ±0.4 C (remaining meas. range) 0.1 C 1 NTC via mini-din socket TC Type K TC Type J -195 to +1350 C -100 to +750 C TC type T TC type S -200 to +400 C 0 to +1760 C ±0.5 C or 0.5% of reading) 0.1 C / TC Type S 1 C 4 TCs via TC socket max. potential difference 50 V Mini-DIN service interface for adjustment is accessible externally Li-ion Plastic IP54 2 to 24 h 6.000 readings per channel -20 to +60 C -40 to +60 C Pt100-200 to +600 C approx. 85 x 100 x 38 mm approx. 220 g 6.3 V DC mains unit; alternatively via 24 V AC/DC plug-in/screw terminals, PoE Power consumption PoE Class 0 (typically 3 W) Display (optional) 2-line LCD; 7 segments with symbols Wall holder included Versions Saveris T1 E Saveris T4 E With display With display 0572 1191 0572 9194 at +25 C ± 0.1 C (0 to +60 C) ±0.2 C (-100 to +200 C) ±0.5 C (remaining meas. range) 0.01 C 1 Pt100 via mini-din socket Saveris Pt E With display 0572 7191 Saveris probes are delivered with a calibration protocol of the works adjustment data. Calibration certificates must be ordered separately. Mains units are not included in delivery. 16

We measure it. testo Saveris components: Ethernet probes % RH NTC % RH NTC C / F and %RH % RH NTC ma V ma and V external external external internal Ethernet Saveris H1 E Saveris H2 E Saveris H4 E Saveris U1 E Humidity Ethernet probe 1% Humidity Ethernet probe 2 % Ethernet probe with external humidity probe connection Radio probe with current/voltage input Probe type 1 channel: Current/voltage input Internal sensor External probe Measuring range Accuracy Probe type Measuring range (instrument) Accuracy (instrument) Resolution (instrument) Connection Dimensions (housing): Weight Supply Buffer battery Housing material Protection class Meas. cycle Memory NTC -20 to +70 C ± 0.2 C (0 to +30 C) ±0.5 C (remaining meas. range) 0.1 C Humidity sensor 0 to 100 %RH 1) to 90 %RH: ±(1 %RH +0.7 % of m.v.) at +25 C > 90 %RH: ±(1.4 %RH +0.7 % of m.v.) at +25 C 0.1% / 0.1 Ctd NTC -20 to +70 C ±0.5 C 0.1 C Humidity sensor 0 to 100 %RH 1) NTC -20 to +70 C 1) Humidity sensor 0 to 100 %RH 1) to 90 %RH: ±2 %rh ± 0.2 C see external probes at +25 C > 90 %RH: ±3 %rf at +25 C ± 0,03 %RH/K ± 1 Digit 0.1% / 0.1 Ctd 0.1 C 0.1%/0.1 Ctd 1 x external humidity probe Mini DIN socket Mini-DIN service interface for adjustment is accessible externally approx. 85 x 100 x 38 mm approx. 230 g approx. 254 g 6.3 V DC mains unit; alternatively via 24 V AC/DC plug-in/screw terminals, PoE Li-ion Plastic IP54 2 to 24 h 6.000 readings per channel Oper. temp. -20 to +60 C Storage temp. -40 to +60 C Power consumption PoE Class 0 (typically 3 W) Display (optional) 2-line LCD; 7 segments with symbols Wall holder included Versions Saveris H1 E Saveris H2 E Saveris H4 E With display With display With display 0572 6191 0572 6192 0572 6194 2-wire: 4... 20 ma 4-wire: 0/4... 20 ma, 0 to 1/5/10V, load: max. 160 Ω at 24 V DC Current ±0.03 ma / 0.75 μa Voltage 0 to 1 V ±1.5 mv / 39 μv Voltage 0 to 5 V ±7.5 mv / 0.17 mv Voltage 0 to 10 V ±15 mv / 0.34 mv ±0.02% of m.v./k deviating from nominal temperature 22 C 1 x 2/4-wire current/voltage input Saveris U1 E no display 0572 3190 Saveris probes are delivered with a calibration protocol of the works adjustment data. Calibration certificates must be ordered separately. Mains units are not included in delivery. 1) Not for condensing atmosphere. For continuous applications in high humidity (>80 %RH at 30 C for >12 h, >60 %RH at >30 C for >12h), please contact us via www.testo.com. approx. 240 g no display Sintered caps for Saveris H1 E, H2 E and H2 D Ethernet probes Metal protective cap, Ø 12 mm for humidity probes, for measurement at flow velocities les than 10 m/s Stainless steel sintered filter, pore size 100 μm, sensor protection for dusty atmospheres or higher flow velocities, for measurement in high flow velocities or contaminated air Cap with wire fabric filter, Ø 12 mm Sintered PTFE filter, Ø 12 mm, for aggressive media, high-humidity applications (long-term measurements), high flow velocities) Testo saline pots for monitoring and humidity adjustment of humidity probes, 11.3% RH and 75.3% RH, incl. adapter for humidity probe, quick check or calibration of humidity probe 0554 0755 0554 0647 0554 0757 0554 0756 0554 0660 17

Saveris testo Saveris accessories: External temperature probes Pt Plug-in probes 100 Robust, Pt100 stainless steel food probe (IP65) Penetration probe Pt100 with ribbon cable, cable length 2 m, IP 54 Illustration Meas. range Accuracy t99 Ø 4 mm Connection: Fixed cable extended Connection cable for unlimited Pt100 stationary probes (4-wire technology), Cable length: 3 m, possible max. cable length: 20 m 125 mm 60 mm Ø 5 mm 15 mm Ø 3 mm 30 mm Ø 3.6 mm -50 to +400 C -50 to +180 C Class A (-50 to +300 C), Class B (rem. meas. range) Class A 10 10 0609 2272 0572 7001 0554 0213 TC Plug-in probes Illustration Meas. range Accuracy t99 Stationary probe with stainless steel sheath, TC Type K Penetration probe TC with ribbon cable, Type K, cable length 2 m, IP 54 Magnetic probe, adhesive power approx. 20 N, with magnets, for measurements on metal surfaces, TC type K Magnetic probe, adhesive power approx. 10 N, with magnets, for higher temperatures, for measurements on metal surfaces, TC type K Pipe wrap probe for pipe diameters from 5-65 mm, with exchangeable measuring head, measuring range briefly up to +280 C, TC type K Pipe wrap probe with Velcro tape, for measuring temperatures on pipes with diameters up to max. 120 mm, Tmax +120 C, TC type K 40 mm Ø 6 mm Connection: Fixed cable 1.9 m 35 mm Fixed cable extended 75 mm Ø 20 mm Connection: Fixed cable 1.6 m 60 mm Ø 5 mm Ø 21 mm Connection: Fixed cable 1.2 m 395 mm 20 mm -50 to +205 C Class 2* 20-50 to +170 C Class 2* 150-50 to +400 C Class 2* -60 to +130 C Class 2* 5-50 to +120 C Class 1* 90 0628 7533 0602 4792 0602 4892 0602 4592 0628 0020 Connection: Fixed cable 1.5 m Thermocouple with TC plug, flexible, length 800 800 mm -50 to +400 C Class 2* 5 0602 0644 mm, fibreglass, TC Type K Ø 1.5 mm Thermocouple with TC plug, flexible, length 1500 1500 mm -50 to +400 C Class 2* 5 0602 0645 mm, fibreglass, TC Type K Ø 1.5 mm Thermocouple with TC plug, flexible, length 1500 1500 mm -50 to +250 C Class 2* 5 0602 0646 mm, fibreglass, TC Type K Ø 1.5 mm Immersion measuring tip, flexible, TC type K 500 mm -200 to +1000 Class 1* 5 0602 5792 Ø 1.5 mm C Immersion measuring tip, flexible, for measurements in air/exhaust gases (not suitable for mea- 1000 mm +1300 C -200 to Class 1* 4 0602 5693 surements in smelters Ø 3 mm 30 mm Ø 3.6 mm -40 to + 220 C Class 1 7 0572 9001 The specified accuracy class of the Saveris radio and Ethernet probe is achieved using these external probes. *Acc. to norm EN 60584-2, the accuracy of Class 1 refers to -40 to +1000 C (Type K), Class 2 to -40 to +1200 C (Type K), Class 3 to -200 to +40 C (Type K). 18

We measure it. testo Saveris accessories: External temperature and humidity probes NTC Plug-in probes Illustration Meas. range Probe accuracy t99 Stump probe, IP 54 35 mm Ø 3 mm -20 to +70 ± 0.2 C (-20 to +40 C) ±0.4 C (+40.1 to +70 C) 15 0628 7510 Stationary probe with aluminium sleeve, IP 65 40 mm -30 to +90 C ± 0.2 C (0 to +70 C) 0628 7503* Ø 6 mm ±0.5 C (remaining meas. range) 190 Connection: Fixed cable; Cable length: 2.4 m Accurate immersion/penetration probe, cable 40 mm -35 to +80 C ± 0.2 C (-25 to +74.9 C) 0610 1725* length 6 m, IP 67 Ø 3 mm Ø 3 mm ±0.4 C (remaining meas. range) 5 Connection: Fixed cable; Cable length: 6 m Accurate immersion/penetration probe, cable 40 mm -35 to +80 C ± 0.2 C (-25 to +74.9 C) 5 0628 0006* length 1,5 m, IP 67 Ø 3 mm Ø 3 mm ±0.4 C (remaining meas. range) Connection: Fixed cable; Cable length: 1.5 m Penetration probe NTC with ribbon cable, cable length 2 m, IP 54 Wall surface temperature probe, e. g. for proof of structural damage in buildings Stainless steel NTC food probe (IP65) with PU line Pipe wrap probe with Velcro tape for pipe diameters of up to max. 75 mm, Tmax. +75 C, NTC 60 mm Ø 5 mm 30 mm Ø 3.6 mm Connection: Fixed cable; Cable length: 3 m 125 mm 15 mm Ø 4 mm Ø 3 mm Connection: Fixed cable; Cable length: 1.6 m 300 mm Connection: Fixed cable; Cable length: 1.5 m 30 mm -40 to +125 C ±0.5 % of reading (+100 to +125 C) ±0.2 C (-25 to +80 C) ±0.4 C (remaining meas. range) 8-50 to +80 C ± 0.2 C (0 to +70 C) 20-50 to +150 C 2) ±0.5 % of reading (+100 to +150 C) 8 ±0.2 C (-25 to +74.9 C) ±0.4 C (remaining meas. range) -50 to +70 ± 0.2 C (-25 to +70 C) ±0.4 C (-50 to -25.1 C) 0572 1001 0628 7507 0613 2211* 0613 4611 % RH Plug-in probes Illustration Meas. range Accuracy Humidity / temperature probe 12 mm -20 to +70 C, ±0,3 C 0572 6172 Ø 12 mm 0 to +100 %RH ±2 %RH at +25 C (2... 98 %RH) ±0.03 %rf ±1 Digit Humidity / temperature probe 4 mm Ø 4 mm 0 to +40 C, 0 to +100 %RH ±0,3 C ±2 %RH at +25 C (2... 98 %RH) 0572 6174 ±0.08 %rf ±1 Digit The specified accuracy class of the Saveris radio and Ethernet probe is achieved using these external probes. *Probe tested according to EN 12830 for suitability for the areas of transport and storage 2) Long-term measuring range to +125 C, briefly to +150 C or +140 C (2 minutes) 19

Saveris testo Saveris : Accessories Power supply Spare batteries for radio probes (4 x AA alkali manganese mignon batteries) Spare batteries for radio probes for operation below -10 C (4 x Energizer L91 Photo lithium) International mains unit 100-240 V AC / 6.3 V DC; for mains operation or battery charging in intrument Mains unit (top-hat rail mounting) 90 to 264 VAC / 24 VDC (2.5 A) Mains unit (desktop) 110 to 240 VAC / 24 VDC (350 ma) Miscellaneous 0515 0414 0515 0572 0554 1096 0554 1749 0554 1748 1 Magnetic foot aerial (dual band) 1 2 Magnetic foot aerial (dual band) with 3 m cable, for Base with GSM module (not suitable for USA, Canada, Chile, Argentina, Mexico) Antenna with magnetic foot (quad band) for Base with GSM module Alarm module (optical + audible), connectable to Base alarm relay, Ø 70 x 164 mm, 24 V AC/DC / 320 ma, permanent light: rot, permanent tone: buzzer approx. 2.4 khz (mains unit 0554 1749 required) 0554 0524 0554 0525 0572 9999 ID-No. 0699 6111/1 2 Programming adapter (from Mini DIN to USB) for Base, Ethernet probes and Converters 0440 6723 3 Saveris protective housing for protection from high-pressure cleaning and impact, IP 69 K suitable for wireless probes T1 / T1D / T2 / T2D / Pt / PtD / H4D Software SBE software, incl. USB connecting cable base-pc PROF software, incl. USB connecting cable base-pc CFR software, incl. Ethernet connecting cable base-pc Saveris adjustment software incl. connection cable to wireless and Ethernet probes Calibration certificates ISO temperature calibration certificate; temperature probe; calibration points -8 C, 0 C, +40 C; per channel/instrument (suitable for Saveris T1/T2) ISO temperature calibration certificate; temperature probe; calibration points -18 C, 0 C, +60 C; per channel/instrument (suitable for Saveris T1/T2) DAkkS temperature calibration certificate*; temperature probe; calibration points -20 C, 0 C, +60 C; per channel/instrument (suitable for Saveris T1/T2) ISO humidity calibration certificate; humidity probe; calibration points 11.3 % RH and 75.3 % RH at +25 C/+77 F; per channel/instrument DAkkS humidity calibration certificate*; humidity probe; calibration points 11.3 % RH and 75.3 % RH at +25 C/+77 F; per channel/instrument *Successor organization of the DKD 0572 0200 0572 0180 0572 0181 0572 0182 0572 0183 0520 0171 0520 0151 0520 0261 0520 0076 0520 0246 Alarm module (visual + acoustic), can be connected to base alarm relay 3 Saveris protective housing 20

We measure it. testo Saveris set All components can be assembled individually by you. However, you also have the option of ordering a testo Saveris set. This can be supplemented with further components as required. Set: 868 MHz, consisting of base 0572 0260, 3 NTC radio probes without display 0572 1250, mains unit for base 0554 1096 and SBE software 0572 0180 incl. USB cable Set / 2.4 GHz 0572 0250 Adjustment All testo Saveris probes are of course adjusted in the factory, as confirmed by an adjustment report. You can perform further calibrations or adjustments either yourself on site, via a service provider or in a calibration laboratory. The separate Saveris adjustment software is available for this. After successful adjustment, the current adjustment data is stored in the probe. At the same time, the adjustment software and the Saveris software accept this data so that the adjustment histories are available. Radio and Ethernet probes are connected to a cable via the service interface for adjustment. If you do not wish to perform your own calibration, Testo is available as a service provider. Saveris adjustment software incl. connection cable to wireless and Ethernet probes 0572 0183 21

Saveris Service Testo is a manufacturer of measuring instruments and measuring systems with a global presence, with 27 international subsidiaries and representatives in numerous countries. Naturally, testo also offers you onsite service. For questions regarding testo Saveris TM, from installation to retrofitting further system components, please refer to your competent contact in your country. You can find an overview of the nearest service location at www.testo.com 22

We measure it. 23

Saveris We measure it. 0981 8164/msp/Si/Q/01.2012 Subject to change without notice.