Manual of Electrical Installation for Pressure Probes KS and KS-SIL2 series

Similar documents
PRESSURE TRANSMITTER

Voltage Output IMPACT MELT PRESSURE TRANSMITTERS IN SERIES TECHNICAL SPECIFICATIONS

MELT PRESSURE TRANSMITTERS IE SERIES WITH CURRENT OUTPUT AND PLc VERSION

Voltage Output MELT PRESSURE TRANSMITTERS IN SERIES TECHNICAL SPECIFICATIONS

RK-A CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER

mv/v Output IMPACT MELT PRESSURE TRANSMITTERS I3 SERIES TECHNICAL SPECIFICATIONS

mv/v Output MELT PRESSURE TRANSMITTERS I3 SERIES TECHNICAL SPECIFICATIONS

OIL FILLED MELT PRESSURE TRANSMITTERS. W7 PERFORMANCE LEVEL c SERIES Voltage output

OIL FILLED MELT PRESSURE TRANSMITTERS. W7 PERFORMANCE LEVEL c SERIES Voltage output

RK-5 ENVIRONMENTAL DATA CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH FLANGED CONNECTION. Main features

IK4A (with ONDA technology)

RK-2 CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH FLANGED HEAD

DMP 333 DMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial

DCT 531. Industrial Pressure Transmitter with RS485 Modbus RTU. Stainless Steel Sensor

RK CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER (ANALOG OUTPUT OR START/STOP)

Pressure transmitter for highest pressure applications Up to 217,500 psi (15,000 bar) Model HP-2

RK-4 CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH THREADED HEAD

Linear Position Transducer HLT 1000-R2

TPE 1464 Series Pressure Transducer

Manual of Electrical Installation for Pressure Probes

PKP Prozessmesstechnik GmbH. Borsigstrasse 24. D Wiesbaden-Nordenstadt. Tel: / Fax: / Operating manual PSA06

LMP 308. Separable Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO / 0.

Online data sheet TBS-1BSGT3506FM TBS TEMPERATURE SENSORS

Electronic pressure switch with display Model PSD-4

Linear Position Transducer HLT 1000-R2

Manual of Electrical Installation for Pressure Probes

I3 - IE - IN - IX - I7

DS 201P. Electronic Pressure Switch. Pressure Port With Flush Welded Stainless Steel Diaphragm. accuracy according to IEC 60770: 0.

EPWR Series. RoHS. Product Description. Available Products. Installation Instructions 01

IK4 P (with ONDA technology)

XMLR400M1P25 Pressure sensors XMLR 400bar - G 1/4-24VDC ma - PNP - M12

MK4 P (with ONDA technology)

Pressure sensor For highest pressure applications to 15,000 bar Model HP-2

P30-2. Overview. Pressure Transmitter Datasheet. *High Quality* 3 Years Warranty. At a Glance. Function. Application

XMLK006B2C21 pressure sensor XMLK bar - G 1/4A mA - DIN - set of 1

mv/v Output MELT PRESSURE TRANSMITTERS I3 SERIES TECHNICAL SPECIFICATIONS

Modular pressure transmitters for harsh environments DST P500, DST P507 and DST P550

Temperature Switches

MODEL: M5DY SEN TRONIC AG CURRENT LOOP SUPPLY. [2] POWER INPUT AC Power M: V AC (Operational voltage range V, Hz)

Miniaturised pressure sensor Model M-10, standard version Model M-11, version with flush diaphragm

ProcessCalibrator Model CPH6000

FTM84/85 Feature Application. Temperature & Humidity / Flow Measuring Specialist

GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26

DP DP2500 DP0250

1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882

KOBOLD TDA Series Digital Temperature Transmitter

Pressure transmitter for mobile hydraulic applications With output signals CANopen and J1939

LMP 307. Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % / 0.

PRESSURE TRANSDUCER Setra 276

MELT PRESSURE TRANSMITTERS KE SERIES PERFORMANCE LEVEL c

BTL6-A_10-M -A1-S115. Data Sheet. english

HD B. [ GB ] Precision Barometer

Electronic pressure switch with display For sanitary applications Model PSA-31

Multi-range pressure and differential pressure transmitter

JUMO MIDAS C08. OEM Pressure Transmitter Basic. Applications. Brief description. Special features. Customer benefits

JUMO ecotrans ph 03 Microprocessor transmitter/ switching device for ph/redox voltage and temperature

itemp TMT180 Technical information

InCos-P Pressure sensor 20 Pa Pa

JUMO MIDAS C08. OEM Pressure Transmitter Basic. Applications. Brief description. Special features. Customer benefits

Distance and Position Sensors

Inductive sensor with analog output BI15-M30-LI-EXI

Original operating instructions Fail-safe inductive sensor GI711S / / 2010

Industrial Pressure Transmitter

E2Q4 Square Proximity Sensor

Gas and Air Sensors. Product Specification. CO 2 Engine K30. Sensor Module and OEM Platform. Document PSP 110. Rev 4. Page 1 (11)

MELT PRESSURE TRANSMITTERS KE SERIES PERFORMANCE LEVEL c

Operating instructions Electronic pressure sensor. PM205x /01 09/2011

TP32MTT.03 TP32MTT [ GB ] Probes for soil thermal profile measurement

XUSL4E2BB051L XUSL type 4 - Body protection - Long sensing range 510 mm

HygroFlex HF7 Humidity Temperature Transmitters. User Guide

ACOPOSinverter P74. User's Manual. Version: 2.20 (August 2016) Model no.: Original instruction

Optical distance sensors. Dimensioned drawing

Isolated Process Current Input 7B32 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Isolated Process Current Input with Loop Power 7B35

Isolated, Process Current Output 7B39 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Electronic Level Switch ENS 3000

EF-S1 SERIES. Continuously check invisible static electricity in lines. Constantly check static in lines!

Precision hand-held pressure indicator Model CPH6400

LXM28AU07M3X motion servo drive - Lexium 28 - single and three phase V W

LMP 308i. Separable Stainless Steel Probe Precision. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO.

XUSL4E14F046N XUSL type 4 - Finger protection - Std sensing range - Hp = 460 mm, R=14mm

MK4 and IK4/SK4/RK4/RK2 Series Installation Manual

Ferrous metal (The sensing distance decreases with non-ferrous metal.) Power supply voltage (operating voltage range)

XUSL4E14F121N XUSL type 4 - Finger protection - Std sensing range - Hp = 1210mm, R=14mm

Isolated Voltage Input 7B31 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

XUSL4E30H151N XUSL type 4 - For hand protection - Std sensing range - Hp = 1510 mm, R=30mm

KOBOLD PDA Series Digital Pressure Transmitter

LMP 308i. Separable Stainless Steel Probe Precision. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO

02/11/2015

XXA18P1AM12 Ultrasonic sensor cyl. 90 deg M18 - Sn=1m - analog 4-20mA - SYNC - connector M12

TM0-1 AMPLIFIER / CONDITIONER MODULE OPERATORS MANUAL. Transducer Techniques R

HIGH ACCURACY PRESSURE TRANSDUCERS

InBin-P Pressure switches from 5 Pa Pa

XMLP200PD730 pressure transmitter - XMLP - 200psi - 1/4"18NPT V - M12 - set 1

CMP Applications. Features

Operating Instructions Differential Pressure Transducer PS27

digiclip Data sheet DF31DP Special features B en

Temposonics. R-Series POWERLINK. Absolute, Non-Contact Position Sensors. Temposonics RP and RH Measuring length mm

4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type designation. TBPN-L1-FDIO1-2IOL Ident-No

DI561 Digital Input Module

Transcription:

Manual of Electrical Installation for Pressure Probes KS and KS-SIL2 series GEFRAN SAFETY GUARANTEE Code 8594A Edition 2/204 Contents. General precautions pag 2 2. Transmitters with amplified analog output pag 2 Standard installation pag 2 Electrical connections series KS pag 3 3. Protection for outdoor installations of analog sensors pag 4 4. Technical specifications pag 5 5. Safety (content according to IEC/EN 6206 paragraph 7) pag 6 This manual is related to KS Series pressure transducer, SIL2 certified according to the standards IEC/EN6206 8594A_MAN_Electrical Installation for Probes_KS and KS-SIL2 Series_2-204_ENG

. General Precautions The system must be used only in accordance with the required protection level. The sensor must be protected against accidental knocks and used in accordance with the instrument s ambient characteristics and performance levels. The sensors must be powered with non-distributed networks and always at lengths of less than 30 mt. In case of outdoor installations, follow the instructions in paragraph 3. 2. Transmitters with amplified analog output Transducers: Serie KS SIL2 Outputs: 0.5...0.5V; 0.5...5.5V; 0...0.V; 0...0.V;...5V;...6V;...0V; 0.2...0.2V; 4...20mA, ecc... Installation remarks - The transducer must be grounded (normally through the machine body or equipment it is installed on). - Use a shielded cable only. The cable shield must be grounded on PLC side and left floating on machine side (on KS version with M2 electrical connector it s possible to connect the shield on machine side by leaving floating the PLC side). - To prevent interference, separate the power cables from the signal cables. Standard installation (recommended) Cable shield floating Machine Press Equipment Transducer Transducer PLC / Instrument Pressure port Ground Cable connector Cable shield to ground Shielded cable 2 8594A_MAN_Electrical Installation for Probes_KS and KS-SIL2 Series_2-204_ENG

Electrical connections VOLTAGE AMPLFIED OUTPUT CONTROLLER AMPLIFIER SUPPLY OUTPUT cod. C cod. Z cod. E cod. F Red Black White CURRENT AMPLIFIED OUTPUT - mod. E CONTROLLER SUPPLY cod. C cod. Z cod. E cod. F Red SIGNAL Black Interfaces with SRP/CS and voltage devices The interface with SRP/CS (Safety Related Part of a Control System) is made by mean of multipolar connectors showed on pictures below, where the connections are specified in case of amplified voltage output (3 wire) or current output (2 wire system, the sensor is connected in series with the current loop). LOAD DIAGRAM (Current output) Ω F 2/3 pole cable Shield TOTAL LOAD RESISTANCE RL Operating Area White Red Black POWER SUPPLY VOLTAGE RL = < (Vsupply - 0V) / 0.02A Shielded cable 3x0,25 - m Protection IP65 Z - 4 pole male connector M2 x E - EN 7530-803 C EN 7530-803 2 3 4 4 pin Male connector serie 73 Protection IP67 4 Pin DIN Type A Protection IP65 4 pin MicroDIN Tipo C Protection IP65 8594A_MAN_Electrical Installation for Probes_KS and KS-SIL2 Series_2-204_ENG 3

3. Protection for outdoor installations of analog sensors Pressure / Analog current output CAL signals if any do not require protection J PLC side +24Vdc D D3 +24Vdc B7220-S-250-K0 B7220-S-250-K0 PLC ground J machine ground Lato PLC +IN D2 +OUT B7220-S-250-K0 J Lato PLC Terra Pressure / Analog voltage output CAL signals if any do not require protection J PLC side +24Vdc D D2 +24Vdc B7220-S-250-K0 B7220-S-250-K0 PLC ground J machine ground PLC side +IN D3 +OUT B7220-S-250-K0 J Lato PLC GND D4 GND B7220-S-250-K0 J PLC side Ground 4 8594A_MAN_Electrical Installation for Probes_KS and KS-SIL2 Series_2-204_ENG

4. Technical specifications Output signal Voltage Current Accuracy () Pressure ranges (2) Resolution Overpressure (without degrading performance) Pressure containment (burst test) Pressure Media < ±0.5% FSO from bar to 000 bar (see table) Infinite see table below see table below Fluids compatible with Stainless Steel AISI 430F and 7-4 PH Housing Stainless Steel AISI 304 Power supply 5...30Vdc 0...30Vdc Dielectric strengh 250 Vdc Zero output signal 0.V; 0.5V; V (*) 4 ma (nominal) Full scale output signal 5V; 5.5V; 0V; 0.V; 0.5V (*) 20 ma (nominal) Max allowed load 2 ma see load diagram Long term stability Operating temperature range (process) Operating temperature range (ambient) Compensated temperature range Storage temperature range Temperature effects over compensated range (zero-span) Response time (0...90%FSO) < 0.2% FSO/per year -40...+25 C (-40...+257 F) -40...+05 C (-40...+22 F) -20...+85 C (-4...+85 F) -40...+25 C (-40...+257 F) ± 0.05% FSO/ C typical (± 0.02% FSO/ C max.) < msec. Warm-up time (3) < 30 sec. Mounting position effects Humidity Weight Negligible Up to 00%RH non-condensing 80-20 gr. nominal Mechanical shock 00g/msec according to IEC 60068-2-27 Vibrations 20g max a 0...2000 Hz according to IEC 60068-2-6 Protections Output short circuit and reverse polarity protection CE Conformity Electromagnetic compatibility Emission Lifetime (*) Other voltage values of Zero and Full Scale available on request. NOTE: SIL2 certification is available from 0-4 bar range and above FSO = Full Scale Output Incl. Non-Linearity, Hysteresis, Repeatability, Zero-offset and Final-offset (acc. to IEC 6298-2) 2 The operating pressure range is intended from 0.5% to 00% FS 3 Time within which the rated performance is achieved IP65/IP67 (EN60529) YES EC Directive 2004/08/CE EN6326-/EN6326-2-3 0 years Range (bar).6 2 2.5 4 6 0 6 20 25 40 60 00 60 200 250 400 600 000 Overpressure (Bar) Burst pressure (Bar) 6 6 6 0 0 20 20 32 40 50 80 20 200 320 400 500 800 200 200 9 9 9 5 5 30 40 64 80 00 60 240 400 640 800 000 500 500 500 8594A_MAN_Electrical Installation for Probes_KS and KS-SIL2 Series_2-204_ENG 5

5. Safety (content according to IEC/EN 6206 paragraph 7) Restrictions on use The device in order to remain compliant with the designated category should be used only as indicated in these instructions and as required in the operating manual concerning mechanical installation, electrical connection, environmental conditions and usage limits. Maintenance and periodic inspections Periodic maintenance to carry-out in order to guarantee the justified exclusion of failures are: - Visual inspection of the status of the electrical and mechanical connections. The maintenance is designed to evaluate possible problems due to situations of incorrect mounting endured over time or particular aggressiveness of the material processed. Frequency: every two years Check obstruction of the channel under pressure - The maintenance has the purpose to verify that there are no occlusion of the pressure channel, which would lead to malfunctioning. The inspection is visual, after removing the probe from the process seat. Frequency: every year. Testing the sensor calibration - The test is intended to check the correctness of the transduction curve of the sensor. It s done by applying known pressure points to the transducer and checking the output values of the probe. Frequency: every four years. Indication of response time The response time to the pressure transduction is equal to ms Indications and alarms The KS Series pressure sensors in the case of some specific anomalies provide output saturation (positive HIGH or negative LOW). The table indicates the detected failures, their effect on the electrical output, and the recovery mode of the device. Table : failures, effects on the outputs Failure Current output Voltage output FS<= 6V FS > 6V Power supply cable broken LOW < 3.8mA LOW < 0.05 V Sensor not connected LOW < 3.8mA LOW < 0.05 V Power supply broken LOW < 3.8mA LOW < 0.05 V Broken bridge *LOW < 3.8mA *LOW < 0.05 V *HIGH > 22mA *HIGH > 7 V *HIGH >.5 V (*) variable according to the type of failure 6 8594A_MAN_Electrical Installation for Probes_KS and KS-SIL2 Series_2-204_ENG

Failures and troubleshooting In case of failures or malfunctions, on Table 2 you can find the most common failures and the means of appropriate search: Table 2: troubleshooting Failure Possible causes Means of research The sensor does not feel pressure Obstruction of pressure channel Fault on electronics output stage. Power down and remove the sensor 2. Verify eventual occlusion of the channel under pressure. Clean any residues and material caps The sensor is in alarm mode type HIGH The sensor is in alarm mode type LOW Bridge broken Detachment of pins Failure on primary element Power supply cable /connector broken Sensor not connected Sensor not powered Bridge broken. Power down and remove the sensor 2. Check for overheating of electronics housing. Remove the causes of overheating, wait until it cools down and power the sensor. 3. Powered the probe again, if the problem persists, you should send back the probe to Factory for repair.. Power down and remove the sensor 2. Check that the power supply is connected. If necessary, restore the power supply. 3. Check for continuity between the pins of the connector and the power supply. If necessary, replace the cable and the connector. 4. Check if the power values are within the specifications indicated in this manual. If necessary, replace the power supply. 5. If the problem persists, you should send back the probe to Factory for repair. Applications to use the relevant category The pressure sensors of KS Series may form part of a system for detecting the pressure that, when a threshold value is exceeded, deactivates all the elements of pressure generation, through a control system. The diagram A (Fig. ) shows a possible application: the sensor detects the pressure and transduces it in an analog electrical signal proportional to the value of the measured value; the SRP / CS compares the signal with the one set as the alarm threshold: in case of exceeding the threshold it shall disable the elements of pressure generation. VOLTAGE OUTPUT CURRENT 2-WIRE OUTPUT Fig. : application diagram A 8594A_MAN_Electrical Installation for Probes_KS and KS-SIL2 Series_2-204_ENG 7

GEFRAN spa via Sebina, 74 25050 PROVAGLIO D ISEO (BS) - ITALIA tel. 0309888. - fax. 0309839063 Internet: http://www.gefran.com 8 8594A_MAN_Electrical Installation for Probes_KS and KS-SIL2 Series_2-204_ENG