INSTALLATION INSTRUCTIONS. lighted and acoustic feedback. capacity to manage up to 200 users. does not require a remote unit. backlit touch keypad

Similar documents
INSTALLATION INSTRUCTIONS. lighted and acoustic feedback. capacity to manage up to 200 users. does not require a remote unit. programmable from PC

AGATA C200 UK A/200N TARGHA 200. Installation Manual AGATAKIT C 200 UK

Stand-alone Proximity Access Control

-DTZ001- Stand-Alone Proximity Access Control. User Manual

RBR-SB-KTZ001 LAR 2. User Manual

Standalone Keypad Access Control. User Manual. Please read the manual carefully before use this unit

Standalone Keypad Access Control. User Manual. SS-TS2000 Size:120*80*25 mm

DOLXFD1000B. Waterproof Access Control/Reader

Single Door Standalone Access Control User Manual

CM-110SK Standalone Keypad Installation Instructions

AUDIO AND VIDEO DOOR ENTRY SYSTEM WITH NEXA CODED PANEL

Waterproof. Keypad/Reader/Controller

Partizan PAB-FC2. Fingerprint scan time Fingerprint identification time. <0.5 s < % <0.0198% Ingress protection rating

CV-550SPK V2 Waterproof Keypad/Reader/Controller Installation Instructions

CV-110SPK Standalone Keypad/Prox Access Control Installation Instructions

Keypad CT2000. Art. No.: , (black) Art. No.: , (white) Installation Manual

GUARD CENTURION OPERATING INSTRUCTIONS THE AUTOMATIC CHOICE

User Manual. Split access control with intelligent secured power supply.

FLOW MONITOR & TRANSMITTER

Instruction Manual. Vogue. Security. Technology. Innovation 2013-V01

Fingerprint Access Control F1. User Manual

The HAUSSMANN RIRI keypad

TEC100 USER/INSTALLER MANUAL V2.0 REV. 03/2018

FLS M9.06. ph/orp MONITOR

2M IR Mini Dome Quick Installation Guide

W3-H Waterproof Keypad/Reader/Controller

W3-M. Metal waterproof standalone access control/reader. User Manual

DG-800 Stand-Alone Proximity Reader Instruction Manual

FLS M9.06 PH/ORP MONITOR. safety instructions. packing List

Installation and User Manual

User Manual. PCKeypad Wireless Keypad

Key Switch. Document version: 1.5 (Updated 02 May 2017)

VIDI-AC-2CS Access Controller/ Reader

RD-SR2 ACCESS SECURITY PRODUCTS LTD. Proximity Card Reader with Remote Control. User Manual

IF-80x Outdoor Terminal

1 IF-812 or IF-815 Terminal (Slave) 2 Intended Use. 3 Assembly and Installation _V IF-812/IF-815

CP150B Vandal & Weather Resistant Keypad Security Systems

Sfera Keypad Module. Installer manual 07/12-01 PC

Compact Keypad. ins /02/2010. Exit button (push to make) 12V DC release current rating must be less than 1A.

_ Access control SISTEMAS DE SEGURIDAD

ACTsmart2 Product Range Operating and Installation Instructions

STD Simple Telemetry Application. Owner s Manual

Digital Keypad Introduction

1 IF-810 or IF-811 Terminal (Slave) 2 Intended Use. 3 Assembly and Installation _V IF-810/IF-811

F6-Fingerprint. Access Control/Reader. User Manual. F6 - Simplified Instruction. (Master Code) # (Factory default:1234) Enter the Programming Mode

FS-24s-H20 (art.257) Installation and service manual. Panel showing 24 seconds shot clock ENGLISH GENERAL INDEX. 1. Electrical power supply system...

EL-ST100 KEYPAD CONTROLLER

212iL Rev. 1.1

2000 Series e/em Style Keypad Installation and Programming Manual

F1000 User's Manual. (Version: V1.01)

KP2000E/EM Series Style Keypad

3001D Smart Safe Manual

SD-40 P/A Keypad Analog Door Phone Door Access Control with Analog Telephony Interface. Door Access Control with analog telephony interface

ZAVIO Outdoor IR Mini Dome. Quick Installation Guide

Zartek. CDP-808 Two Button Wireless Intercom Installers Manual

Installing Keypad and Backplate

QUICK START GUIDE. 2.4 Inch TFT Terminal Time Attendance & Access Control

Installation Guide for PR311SE and PR311SE-BK v1.0 Access Controllers Rev. B

Wireless Inspection Camera with recording LCD monitor. Product code: SRCAMV6 CAMERA NUMBER:

Installers & User guide Smart Mortise.

REX F-0-9 Standalone or Access Controller

Access control panel U-Prox IC E (Elevator control)

KRAMER ELECTRONICS LTD. USER MANUAL MODEL: RC-76R/RC-78R Room Controllers. P/N: Rev 5

DM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER

SUN KTL-USH0 Quick Guide. Issue: 01 Part Number: Date: HUAWEI TECHNOLOGIES CO., LTD.

GV-IPCam H.264. Hardware Manual. Bullet Camera Ultra Bullet Camera Target Bullet Camera

ZC-OH5 TAMPER-RESISTANT INDOOR/OUTDOOR HOUSING INSTRUCTION MANUAL FOR USE WITH GANZ ZC-D5000 SERIES MINIDOME CAMERAS

AR10S-MF AR11S-MF AR40S-MF AR41S-MF Installation manual for mounting and connecting. Siemens AB. Version 5.0 A Security Products

INSTALLATION GUIDE 2.4 Inch TFT Terminal Time Attendance & Access Control

HGM9580 Bus Tie Bus Parallel Unit USER MANUAL. Smartgen Technology

Dome Camera. Hardware Manual Z81, Z /01/08

Installation manual EVA Start and Protected

BreezeMAX Wi² and BreezeACCESS Wi² Quick Installation Guide

232iLM Keypad Installation and Programming Instructions

imac Intel 21.5" EMC 2389 Stand Replacement

SUN KTL-M0 Quick Guide (Europe Edition) Issue: 01 Part Number: Date: HUAWEI TECHNOLOGIES CO., LTD.

SUN2000-(33KTL, 36KTL, 40KTL)-US Quick Guide (Mounting Bracket Supplied with the SUN2000, Amphenol Helios H4)

Cube LAN Gateway. Operating manual BC-LGW-O-TW

Model INSTRUCTION MANUAL DIGITAL MULTIMETER

HSY-S209 EM Metal waterproof access control system User Manual

INSTALLATION INSTRUCTIONS Model 930 EntryCheck

RS-FS-N01 Wind speed transmitter user's Guide (485type)

NS1 Connection Unit Guide

D1265. Installation Guide. Touchscreen Keypad

Quick Start Guide. ProBio & ProFAC + ZKBioSecurity 3.0

Nanoject III. Programmable Nanoliter Injector INSTRUCTION MANUAL

Signal Tower KombiSIGN 50

M U L TI - SP ORT SCOREBOARD

DRUCK & TEMPERATUR LEITENBERGER GMBH

Package Contents. GP Options (Made by Digital)

Product and Function Description

Sigma Si. Extinguishant Status Unit (K , K , K , K , K , K , K , K )

EZTAG3 PROXIMITY AND KEYPAD DOOR ENTRY

Product Information. DCM Standard indoor stations TK IS A 514 A.. TK IS A 514 AD.. (Design)

3001D Smart Safe Manual

Sigma Si Weatherproof Extinguishant Status Unit (W911000W8, W911100W8, W911110W8, W911113W8)

PumpDrive. Self -cooling, motor-independent frequency inverter. Brief Instructions

Amano (itrt) Intelligent Twin Reader Terminal INSTALLATION MANUAL

RFID/Digital Access Control Keypad

EntraGuard Bronze. Quick Start Guide. Telephone Entry. 1.0 Specifications. 2.0 Unit Installation

Transcription:

DIGITO MATRIX Stand Alone Access Control with numerical codes Stand Alone Access Control with numerical codes and transponder reader lighted and acoustic feedback capacity to manage up to 200 users does not require a remote unit backlit touch keypad programmable from PC or keypad dust and waterproof simple and intuitive to use tamper-proof system antiscan signal configurable auxiliary input and output INSTALLATION INSTRUCTIONS

2

CONTENTS ACCESS CONTROL 1 - INTRODUCTION... PAG. 4 2 - PACKAGE CONTENTS... PAG. 4 3 - FEATURES... PAG. 5 4 - INSTALLATION... PAG. 6 4.1 - ACCESS CONTROL UNIT DISASSEMBLY... PAG. 6 4.2 - CABLE SLEEVE SELECTION... PAG. 7 4.3 - FASTENING TO A WALL... PAG. 7 4.4 - TAMPER-PROOF PROTECTION... PAG. 8 5 - ELECTRICAL CONNECTIONS... PAG. 9 5.1 - POWER SUPPLY CONNECTION DIAGRAM... PAG. 9 5.2 - RELAY OUTPUT CONNECTION DIAGRAM... PAG. 10 5.3 - AUXILIARY INPUT CONNECTION DIAGRAM (OPTIONAL)... PAG. 10 5.4 - AUXILIARY OUTPUT CONNECTION DIAGRAM (OPTIONAL)... PAG. 10 5.3 - ANTI-FORCING OUTPUT CONNECTION DIAGRAM (OPTIONAL)... PAG. 11 6 - PROGRAMMING... PAG. 11 6.1 - USER MANAGEMENT... PAG. 12 6.2 - CHANGING THE OPERATION PARAMETERS... PAG. 13 6.3 - LIGHT AND ACOUSTIC SIGNALS... PAG. 14 6.4 - PROGRAMMING VIA PC... PAG. 17 7 - DISPOSAL... PAG. 17 8 - FREQUENT OPERATIONS... PAG. 18 8.1 - STARTUP OF THE APPARATUS AFTER INSTALLATION... PAG. 18 8.2 - PROGRAMMING MODE ENTRY/EXIT... PAG. 20 8.3 - USER STORAGE/DELETION... PAG. 21 3

1 INTRODUCTION The access control system allows to control and limit access to places or services to authorized persons only. It does not require a remote unit: despite its compact dimensions, it provides numerous functionalities working in a completely autonomous manner. The following versions are available: DIGITO The recognition occurs by entering on the peripheral's keypad an access code which has been previously stored (see Fig.1). The keypad is a touch key type: to select a key, it's enough to just touch it with a finger. The selection is signalled with a short beep and a brief interruption of keypad backlighting. MOVHE DIGITO It is advisable not to wear gloves when using the keypad, since this may significantly reduce the sensitivity of the keys. MOVHE MATRIX MOVHE MOOVY FIG.1 MATRIX The recognition may occur through two operating modes (see Fig.2): - entering on the peripheral's keypad an access code which has been previously stored, in a manner completely analogous to that which is used in the basic version; - bringing a previously stored keychain-transponder close to the peripheral. FIG.2 The user code can be either a numerical code or (only for MOVHE MATRIX) a transponder. The recognition of a valid or invalid user code is signalled acoustically and visually, through the lighting of the front LED (see Fig.3). STAND-BY VALID MASTER OR STANDARD USER CODE ENTERED INVALID MASTER OR STANDARD USER CODE ENTERED RELAY ACTIVATION LIGHTING OF GREEN LED 3 SHORT BEEPS FIG.3 LIGHTING OF RED LED 1 LONG BEEP 2 PACKAGE CONTENTS - No.1 Access Control Unit - No.1 IP68 Cable Sleeve - No.1 Packet of screws and plugs including: - No.2 screws and plugs Ø6 for fastening the unit to a wall - No.2 self-threading screws 4.2x13 for fastening the unit on a panel or tubing - No.1 burglar-proof countersunk-head screw M3x8 Torx TX10 for frame fastening 4

3 FEATURES - 10-15V DC / 12V AC power supply voltage with automatic selection. - NO/NC Relay output contact with 5A-24V capacity. - Bistable or monostable relay mode with programmable activation time. - No.1 input configurable as opening push button. - No.1 Open-Collector NPN output with maximum current 100 ma and configurable signal (valid or invalid code, relay status replication, antiscan, programming status, etc.). - Input through backlit touch keypad. - Transponder Tag reader (MOVHE MATRIX only) - Parameter programming through the keypad. - Possibility to activate programming and deletion of users using a Master user code. - Maximum number of users managed: 200. Each user can be a Master user with the possibility to activate user management. - Antiscan function to signal attempts to force entry with invalid codes. - Acoustic signalling with adjustable volume which can be turned off. - Overvoltage and interference protection for all the board inputs and outputs. - Overcurrent protection of the board outputs with self-resetting fuses. - PC programming through MOVHEPROG programmer and Mini-USB connector. - Maximum dimensions: Height 148 mm x Width 51 mm x Depth 34 mm (see Fig.3). - Operating temperature: -10 C +50 C. - Degree of protection: IP67 (using the appropriate cable sleeve provided) - Max degree of humidity: 95% MOVHE DIGITO e MOVHE MATRIX dimensions Signal LED Fastening hole Backlit touch keypad Cable feedthrough hole Fastening hole FIG.4 5

4 INSTALLATION 4.1 ACCESS CONTROL UNIT DISASSEMBLY To install and wire the access control unit, the plastic parts of the control unit must be disassembled. In reference to Figure 5, proceed as follows: 1 - Open the package and extract the access control unit (A) 2 - Unscrew the M3x8 countersunk socket-head screw (B) that fastens the frame (C) using a 2mm Allen key. 3 - Release the lower closing tooth of the frame (C) by turning it slightly upwards 4 - Extract the frame (C) 5 - Unscrew the 4 self-threading screws (D) 6 - Separate the complete electronics shell (E) from the base (F) Be careful not to remove the rubber gasket, which must remain united with the base (F), and the USB plug, which must remain united with the shell (E), from their appropriate seats. Now you may proceed with the installation and wiring of the access control unit. To reassemble the access control unit, follow the disassembly steps in the reverse order. A B C E D F FIG.5 6

4.2 CABLE SLEEVE SELECTION In reference to Figure 7, two types of cable sleeve can be applied to the base: Cable sleeve B Cable sleeve A A - type "A" cable sleeve, provided already assembled on the base, to be drilled according to the cable dimension. This cable sleeve guarantees a moderate protection against dust but not water (IP54). B - type "B" cable sleeve, provided in the package. This cable sleeve, if assembled properly, guarantees a perfect seal against dust and water (IP67). FIG.6 For outdoor applications and in all cases in which a good water and dust seal is required, the type "B" cable sleeve must be assembled following the indications in Figure 7. The larger dimensions of this cable sleeve must be taken into consideration during installation. For indoor applications, the type "A" cable sleeve is sufficient. FIG.7 4.3 FASTENING TO A WALL Il controllo accessi è fornito di viti e tasselli per il fissaggio su muro, pannello o tubolare. Eseguire il fissaggio come da fig.8 (su muro) o 9 (su pannello o tubolare). The access control unit, if fitted with an IP68 cable sleeve (see Section 4.2), can also be installed outdoors. Plug Ø6 mm FIG.8 7

Self-threading screws Ø4.2 If the MOVHE MATRIX is being fastened to metal surfaces, a small reduction in the sensitivity of the transponder reader may occur. To prevent this from occurring, if necessary, a layer of insulating plastic material (a few cm thick) placed between the access control unit and the metal support is sufficient. If two MOVHE MATRIX units are being assembled near one another (less than 30cm apart), a considerable reduction in the sensitivity of the transponder reader may occur. To prevent this from occurring, a layer of metallic material (such as sheet metal) placed between the two units is sufficient. FIG.9 15 mm D - Cable sleeve A - Shielded multipolar cable B - Single cable For convenient wiring (see diagram in Fig.10), leave about 15mm of sheathed cable (Fig.10, Detail A) and about 72mm of individual cables without outer sheath (Fig.10, Detail B) sticking out from the fastening wall or panel. 72 mm C - Terminal board FIG.10 4.4 TAMPER-PROOF PROTECTION The Movhe Access control unit is provided with an additional screw equipped with burglar-proof head impression. If you would like to guarantee a certain resistance to tampering attempts, replace the standard screw with the burglar-proof screw included in the package (see Fig.11). The screw must be tightened using the appropriate insert which is available separately as an accessory. A FIG.11 8

5 ELECTRICAL CONNECTIONS Fig.12 shows the electronic board including the terminals for the electrical wiring. All the electrical connections should be made after having fastened the base and relative cable sleeve to the support wall (see Fig.5, Detail F). I/O Description J1 Connector for auxiliary Inputs/Outputs J4 Connector for anti-forcing signal output (Tamper) J7 Connector for power supply connection and relay output USB Connector for PC connection J7 J1 J4 USB FIG.12 Before carrying out the wiring, make sure that the product's characteristics are compatible with the intended use, especially with regard to the power supply voltage and electrical load connected to the output relay. 5.1 POWER SUPPLY CONNECTION DIAGRAM J7- + J7- - 10-15V DC 12V AC Make the connection as indicated in Fig.13. If a direct-current power supply is being used, strictly respect the polarities indicated. If an alternating-current power supply is being used, no specific polarity needs to be respected. FIG.13 9

5.2 RELAY OUTPUT CONNECTION DIAGRAM Terminals connection Relay Output J7-COM J7-NA Normally Open J7-COM J7-NC Normally Closed J7-COM J7-NC J7-NA NC COM NA FIG.14 The appliance must have a maximum capacity of 5A/24V. The relay output can be set as bistable or monostable with different activation times. See Section 6.2. 5.3 AUXILIARY INPUT CONNECTION DIAGRAM (OPTIONAL) J1-COM J1-IN DOOR OPENING PUSH BUTTON The auxiliary input can be used, for example, to connect an opening push button (the closure of the contact always activates the relay), as shown in Fig. 15. For the activation or deactivation of the auxiliary input, see section 6.2. FIG.15 5.4 AUXILIARY OUTPUT CONNECTION DIAGRAM (OPTIONAL) J1-OUT Each Open-Collector auxiliary output offers the possibility to connect a relay, an LED (with appropriate resistor in series), etc. As an example, Fig.16 schematizes the connection of a relay powered by the same power supply network as the access control unit. FIG.16 The two NPN auxiliary outputs have a maximum current of 100 ma and output voltage, in direct current, equal to that of the control unit power supply. For the activation/deactivation of the auxiliary output settings, see section 6.2. 10

5.5 ANTI-FORCING OUTPUT CONNECTION DIAGRAM (OPTIONAL) J4 It is possible to signal, through the "Tamper" output (Terminal J4), an attempt to force entry or disassemble the access control unit. This signal can be used to turn on a light and/or acoustic signal or to supply a pulse to a burglar alarm system. The Tamper contact is N.C.: it is open when the access control unit is correctly disassembled and closes when a disassembly attempt is detected. FIG.17 6 PROGRAMMING To change the operation parameters and manage the user codes, it is necessary to enter the Programming Mode by entering a special "MASTER" code using the Keypad or, in the case of the MOVHE MATRIX unit, using a Transponder. STANDARD USER CODE = allows to activate the output. MASTER USER CODE = allows to activate the output and enter the Programming Mode, and thus register/delete other user codes and change the operation parameters. Each numerical code and each transponder can be stored by choice as a standard or master user code. The Programming Mode entry and exit operations are different depending on whether the unit is a MOVHE DIGITO or MOVHE MATRIX version. Carefully read the instructions for the access control unit being used. If there are no registered users (First Startup), the unit automatically enters the Programming Mode when the first keypad code is entered or the first transponder is detected. The first user code stored will always be a Master code and can be used for storing additional user codes or to exit the Programming Mode. Take particular note of the first code entered, since it will be used for subsequent programming operations. Operation MOVHE DIGITO MOVHE MATRIX ENTRY IN THE PROGRAMMING MODE EXIT FROM THE PROGRAMMING MODE Enter a MASTER code on the keypad and press the OK key for at least 5 seconds Enter the same MASTER code used to enter the Programming Mode and press the OK key. Enter a MASTER code on the keypad and press the OK key for at least 5 seconds, or bring a MASTER transponder close to the access control unit and leave it in the detection field for at least 5 seconds. Enter the same MASTER code used to enter the Programming Mode and press the OK key, or bring the same MASTER transponder used to enter the Programming Mode close to the access control unit again. For security reasons, the programming mode is always automatically exited after 30 seconds of inactivity. FIRST STARTUP Enter a 6-digit numerical code on the keypad: it will be stored as the first MASTER user code and the unit will automatically enter the Programming Mode. TAB.1 Enter a 6-digit numerical code on the keypad or bring a transponder close to the access control unit: it will be stored as the first MASTER user code and the unit will automatically enter the Programming Mode. 11

6.1 USER MANAGEMENT Once the Programming Mode has been activated, it is possible to store new standard or master users or delete those already existing (Single User Deletion) proceeding according to the diagram in Fig.18 or following the indications in Table 2. All the users stored in the memory can be deleted (Total User Deletion), including the MASTER stored at the First Startup. In this case, at the end of the deletion, the unit returns to the First Startup condition described in Table 1: when the first code is entered on the keypad, the access control unit enters the Programming Mode and stores the first user code as a MASTER code. To perform the Total User Deletion, see section 6.2. ENTER MASTER CODE (5 S) STAND-BY PROGRAMMING MODE ENTER MASTER CODE USED FOR ACTIVATION OR SECURITY TIMEOUT (30 S) A maximum of 200 users can be stored. When this limit is reached, the unit will allow user deletion only ENTER VALID USER CODE STORAGE STANDARD CODE STANDARD CODE (OK) EXISTING CODE NO CODE TYPE REQUEST SI MASTER CODE (NO) NO DELETION STORAGE MASTER CODE SI CODE DELETION FIG.18 Operation MOVHE DIGITO MOVHE MATRIX STORING/DELETING USER CODES 1. Select the code by entering the value or bringing the transponder close to the detection area 1. Select the code by entering the value and pressing the OK key. Pressing the OK key is and pressing the OK key. Pressing the OK key always required regardless of which code protection mode is selected. is always required regardless of which code protection mode is selected. 2. If the code is already stored, confirmation is 2. If the code is already stored, confirmation is requested for its deletion; pressing the OK key requested for its deletion; pressing the OK key will delete the code, pressing the NO key will will delete the code, pressing the NO key will keep the code. keep the code. 3. If the code is new, the unit will request that its 3. If the code is new, the unit will request that its type be indicated: Master (NO key) or Normal type be indicated: Master (NO key) or Normal User (OK key), after which the code will be stored. User (OK key), after which the code will be stored. TAB.2 12

6.2 CHANGING THE OPERATION PARAMETERS Once the Programming Mode has been activated, it is possible to view and modify the values of the device parameters according to the diagram in Fig.19 or following the indications in Table 3. It is also possible to carry out special operations, such as the Total User Deletion, or reset the default parameters by entering the reference code and pressing the OK key for at least 5 seconds. PRESS THE "NO" KEY OR SECURITY TIMEOUT (30 SECONDS) ENTER MASTER CODE (5 S) STAND-BY SELECT THE PARAMETER TO BE CHANGED AND PRESS THE "OK" KEY CHANGE VALUE AND PRESS OK KEY PROGRAMMING MODE CURRENT VALUE OF THE PARAMETER ENTER MASTER CODE USED FOR ACTIVATION OR SECURITY TIMEOUT (30 S) Operation CHANGING THE OPERATION PARAMETERS MOVHE DIGITO MOVHE MATRIX 1. The parameter is selected by entering the reference (see the table below) and pressing the OK key. 2. The current value of the parameter is indicated by the number of consecutive flashes of the Green LED. 3. The parameter can be changed by entering the new value and then pressing the OK key, or return to the programming state by pressing the NO key. VALID VALUE? NO SI TAB.3 STORAGE NEW VALUE FIG.19 Parameter Description Range Value 0 Normal operation - 1 Monostable/Bistable Relay Mode and activation time 1 9 2 Signal Tone volume 1 5 3 Keypad Backlighting Level 1 5 4 Opening Input Enable 1 2 5 Code Protection Enable 1 2 6 Enabling and Setting the Antiscan Mode 1 9 7 Setting the length of the keypad code 3 6 8 Signals on Open-Collector output 1 6 9 PC Access Protection Mode 1 2 20 Total User Deletion (*) - 99 Setting the Default Parameters (*) - TAB.4 (*) To carry out these operations, for security reasons, it is necessary to select the parameter and confirm by pressing the "OK" key for at least 5 seconds. 13

PARAMETER 1 - RELAY MODE Value Description 1 Bistable Mode 2 Monostable Mode, Activation 0.5 seconds 3 Monostable Mode, Activation 1 second (Default) 4 Monostable Mode, Activation 2 seconds 5 Monostable Mode, Activation 3 seconds 6 Monostable Mode, Activation 5 seconds 7 Monostable Mode, Activation 7 seconds 8 Monostable Mode, Activation 10 seconds 9 Monostable Mode, Activation 20 seconds TAB.5 The relay output (terminal J7) can be set as bistable or monostable with different activation times. For the connection diagram, refer to Fig.14. PARAMETER 2 - SIGNAL TONE VOLUME Value Description 1 Tones Disabled 2 Tones Enabled at 25% 3 Tones Enabled at 50% (default) 4 Tones Enabled at 75% 5 Tones Enabled at 100% TAB.6 PARAMETER 3 - KEYPAD BACKLIGHTING LEVEL Value Description 1 Backlighting Disabled 2 Backlighting Enabled at 25% 3 Backlighting Enabled at 50% (default) 4 Backlighting Enabled at 75% 5 Backlighting Enabled at 100% TAB.7 PARAMETER 4 - OPENING INPUT ENABLE Value Description 1 Input for opening command disabled (Default) 2 Input for opening command enabled TAB.8 Enables the auxiliary input J7-IN for the connection of an opening push button, for example. PARAMETER 5 - CODE PROTECTION ENABLE The code protection function is useful when there is the possibility that someone may observe and memorize the code while it is entered. The access control unit evaluates the code only after the "OK" key has been pressed. Assuming that the code is made up of n digits (see Parameter 7), it is possible to enter as many numbers as you like before activating the "OK" key. The access control unit will read only the last n digits entered. Value Description Under standard conditions, the keypad 1 Code protection mode disabled (Default) reads the code entered considering the 2 Code protection mode enabled first n digits entered, without having to TAB.9 press the "OK" key. 14

PARAMETER 6 - ANTISCAN MODE Value Description 1 Antiscan Disabled 2 Antiscan Enabled at 1 attempt 3 Antiscan Enabled at 2 attempts 4 Antiscan Enabled at 3 attempts (default) 5 Antiscan Enabled at 4 attempts 6 Antiscan Enabled at 5 attempts 7 Antiscan Enabled at 6 attempts 8 Antiscan Enabled at 8 attempts 9 Antiscan Enabled at 10 attempts TAB.10 The system has an antiscan mode that can be activated and configured which allows to recognize and signal any attempts to force entry with invalid codes. If the functionality is active, after a programmable number of continuous access attempts with invalid user codes, the unit activates the internal antiscan status which can be signalled using the configurable output J4. The signal resets upon recognition of a valid user code. PARAMETER 7 - LENGTH OF THE KEYPAD CODE Value Description 1 Code length 3 digits 2 Code length 4 digits 3 Code length 5 digits 4 Code length 6 digits (Default) TAB.11 The length of the numerical code to be entered on the keypad is configurable between 3 to 6 digits.. The length of the keypad code can be configured only when the user memory is completely empty. PARAMETER 8 - SIGNALS ON OPEN-COLLECTOR OUTPUT Value Description 1 No Signal (default) 2 Relay Status Signal 3 Valid Code Signal 4 Invalid Code Signal 5 Anti-forcing Activation 6 Programming State TAB.12 The auxiliary output J1-Out (Ref.Par.5.4) can be programmed to return the signals listed in Table 12. PARAMETER 9 - PC ACCESS PROTECTION MODE Using the MOVHESOFT software and the MOVHEPROG programming interface, the programming of the devices and users can be carried out via PC. To prevent fraudulent use, when activating this mode, it is possible to prevent programming via PC until activation of the Programming Mode on the access control unit using a master user code. In this manner Value Description only a person holding a master code is allowed to 1 PC Access Protection disabled (default) program via PC. 2 PC Access Protection enabled TAB.13 15

6.3 LIGHT AND ACOUSTIC SIGNALS During programming, acoustic and visual signals are active to confirm the execution of the operations and to signal the state of the system or the request for user input. Operation LIGHT SIGNALS ACOUSTIC SIGNALS NUMERICAL KEYS SELECTION Brief interruption of key lighting 1 Short High Beep "OK" KEY SELECTION - 1 Long High Beep "NO" KEY SELECTION Brief interruption of key lighting 1 Short High Beep ENTRY IN THE PROGRAMMING MODE Continuous flashing of green LED 1 Long High Beep VALID USER CODE RECOGNITION - 3 Short High Beeps INVALID USER CODE RECOGNITION - 1 Short High Beep KEYING ERRORS - 1 Long Low Beep MEMORY FULL Single flash of yellow LED 1 Short Low Beep (each 1 sec.) USER CODE DELETION Single flash of red LED 1 Long Low Beep USER CODE RETENTION Single flash of green LED 2 Short High Beeps MASTER USER CODE STORAGE Single flash of green LED 3 Short High Beeps STANDARD USER CODE STORAGE Single flash of green LED 2 Short High Beeps PARAMETER VALUE Single flash of green LED 1 Short High Beep TOTAL USER CODE MEMORY DELETION Single flash of green LED 3 Short Low Beeps DEFAULT VALUES RESET Single flash of green LED 2 Short Low Beeps EXIT FROM THE PROGRAMMING MODE - 1 Long High Beep TAB.14 State LIGHT SIGNALS ACOUSTIC SIGNALS INITIALIZATION AFTER POWER-ON Fast continuous flashing of Yellow LED - USER CONFIGURATION Slow continuous flashing of Red LED - CODE DELETION REQUEST Fast continuous flashing of Red LED - CODE TYPE REQUEST (STANDARD OR MASTER) PARAMETER VALUE INDICATION Fast continuous flashing of Red and Greed LEDs Flashing of Green LED indicating the current value of the selected parameter TAB.15 - - 16

6.4 PROGRAMMING VIA PC PC MOVHEPROG The programming of the parameters can be carried out via PC using the MOVHESOFT software, which can be downloaded from the site www.movhe.it, and the MOVHEPROG programming interface, available as an accessory. For the connection, the MOVHEPROG programmer (see Fig.20) must be connected to the USB socket on the lower part of the access control unit. For the operation of the programmer, refer to the appropriate instructions. FIG.20 1 Proceed as described below: 1 - Disassemble the frame as described in Fig.5 and locate the rubber plug in the lower part of the access control unit. 2 - Rotate the rubber plug that protects the USB connector. 2 3 - Insert the cable (Optional) for connection to the MOVHEPROG USB programmer. When finished programming, during reassembly of the frame, make certain that the plug is repositioned correctly in its seat in order to avoid compromising the unit's watertight seal. 3 FIG.21 If the PC Access Protection (see section 6.2) is enabled, no operation can be carried out via PC until the programming mode of the Access Control Unit is activated using a master user code. 7 DISPOSAL The access control systems MOVHE DIGITO and MATRIX are composted of recyclable parts (plastic, copper, etc.) and electronic boards that must be disposed of in compliance with current local regulations. The electronic boards may contain pollutants and must never be disposed of as household waste. 17

8 FREQUENT OPERATIONS 8.1 - STARTUP OF THE APPARATUS AFTER INSTALLATION WHEN INSTALLATION IS FINISHED, PROCEED AS FOLLOWS: 1 MAKE CERTAIN THAT THE ELECTRICAL CONNECTIONS HAVE BEEN MADE CORRECTLY, IN COMPLIANCE WITH THAT DESCRIBED IN THIS MANUAL. PAY PARTICULAR ATTENTION TO RESPECTING THE POWER SUPPLY POLARITY IF A DIRECT-CURRENT POWER SUPPLY IS BEING USED. 2 POWER THE APPARATUS. THE LED WILL EMIT A YELLOW FLASH AND THE KEYPAD WILL BECOME BACKLIT. 3 THE APPARATUS SIGNALS THAT THE MEMORY IS EMPTY AND ACTIVATES THE PROGRAMMING MODE AUTOMATICALLY, EMITTING MEDIUM BEEPS (WITH A DURATION OF ABOUT 1 SECOND) REPEATED EVERY 30 SECONDS AND LIGHTING THE FRONT GREEN LED INTERMITTENTLY. 4 AT THIS TIME IT IS CONVENIENT, IF DESIRED, TO CHANGE THE LENGTH OF THE KEYPAD CODE. THIS SETTING CAN BE CHANGED ONLY WHEN THE USER CODE MEMORY IS EMPTY; IF IT IS DESIRED TO CHANGE THE LENGTH AT A LATER TIME, IT WILL BE NECESSARY TO DELETE ALL THE USERS STORED IN THE MEMORY UP UNTIL THAT TIME, WHETHER THEY ARE NUMERICAL CODES OR TRANSPONDERS. AS A DEFAULT, THE CODE IS COMPOSED OF 6 DIGITS. THE USER CODE CAN BE SET TO HAVE A LENGTH OF 5, 4 OR 3 DIGITS FOLLOWING THE PROCEDURE BELOW. IF YOU DO NOT WISH TO CHANGE THE LENGTH OF THE KEYPAD CODE, GO DIRECTLY TO POINT 12. VARIATION OF THE KEYPAD CODE LENGTH (OPTIONAL) 5 PRESS 7 ON THE KEYPAD TO SELECT THE PARAMETER KEYPAD CODE LENGTH 7 6 PRESS OK 7 THE NUMBER OF CONSECUTIVE FLASHES OF THE FRONT GREEN LED AND THE NUMBER OF CONSECUTIVE SHORT BEEPS INDICATE THE DEFAULT VALUE OF THE PARAMETER, EQUAL TO 4 SELECT: 8 1 TO SET THE USER CODE LENGTH EQUAL TO 3 DIGITS 1 2 2 TO SET THE USER CODE LENGTH EQUAL TO 4 DIGITS 3 TO SET THE USER CODE LENGTH EQUAL TO 5 DIGITS 3 9 PRESS OK 10 NOW THE VALUE OF THE PARAMETER INDICATED BY THE NUMBER OF FLASHES AND NUMBER OF SHORT BEEPS MATCHES THE SET VALUE 11 PRESS NO OR WAIT 30 SECONDS TO RETURN TO THE PROGRAMMING MODE 12 NOW IT IS POSSIBLE TO ENTER THE FIRST MASTER CODE WHICH CAN BE: - A NUMERICAL CODE OF LENGTH EQUAL TO THE SET LENGTH; IN THIS CASE GO DIRECTLY TO POINT 13 - A TRANSPONDER (MOVHE MATRIX ONLY); IN THIS CASE GO DIRECTLY TO POINT 17 18

STORAGE OF THE FIRST NUMERICAL MASTER USER CODE 13 ENTER A NUMERICAL CODE WITH A LENGTH EQUAL TO THE SET LENGTH. TAKE NOTE OF THIS CODE, SINCE IT WILL BE NEEDED FOR SUBSEQUENT USER PROGRAMMING, STORAGE AND DELETION 14 PRESS OK. 15 THE CODE HAS BEEN STORED (SHORT BEEP IMMEDIATELY FOLLOWED BY A LONG BEEP) 16 ENTER THE FIRST MASTER CODE AGAIN OR WAIT 30 SECONDS TO EXIT THE PROGRAMMING MODE 17 THE EXIT FROM THE PROGRAMMING MODE IS SIGNALLED BY THE LED WHICH STOPS FLASHING AND A MEDIUM BEEP. GO TO POINT 22. STORAGE OF THE FIRST TRANSPONDER MASTER USER CODES (MOVHE MATRIX ONLY) 18 BRING A MOVHE MOOVY TRANSPONDER CLOSE TO THE APPARATUS 19 THE TRANSPONDER HAS BEEN STORED (SHORT BEEP IMMEDIATELY FOLLOWED BY A LONG BEEP) AS THE FIRST MASTER USER CODE 20 BRING THE MOVHE MOOVY TRANSPONDER CLOSE TO THE APPARATUS AGAIN OR WAIT 30 SECONDS TO EXIT THE PROGRAMMING MODE. 21 THE EXIT FROM THE PROGRAMMING MODE IS SIGNALLED BY THE LED WHICH STOPS FLASHING AND A MEDIUM BEEP. GO TO POINT 22. 22 NOW THE APPARATUS IS CORRECTLY OPERATIONAL IN STAND-BY MODE 19

8.2 - PROGRAMMING MODE ENTRY/EXIT THE PROGRAMMING MODE IS A PARTICULAR OPERATIONAL MODE THAT ALLOWS TO CARRY OUT IMPORTANT OPERATIONS SUCH AS THE STORAGE AND DELETION OF STANDARD OR MASTER USER CODES. TO ACTIVATE THE PROGRAMMING MODE IT IS NECESSARY TO HAVE A MASTER USER CODE. PROCEED AS FOLLOWS: PROGRAMMING MODE ENTRY/EXIT USING A MASTER NUMERICAL CODE 1 ENTER A PREVIOUSLY STORED NUMERICAL MASTER CODE. ENTERING THE MASTER CODE WILL ACTIVATE THE RELAY 2 ENTERING A VALID USER CODE ACTIVATES THE RELAY, THE FRONT GREEN LED AND THE ACOUSTIC SIGNAL (3 SHORT BEEPS) 3 PRESS OK FOR AT LEAST 5 SECONDS 4 A LONG BEEP AND THE FLASHING OF THE GREEN LED WILL INDICATE THE ENTRY INTO THE PROGRAMMING MODE. NOW IT IS POSSIBLE TO CHANGE PARAMETERS AND STORE OR DELETE USERS 5 TO EXIT FROM THE PROGRAMMING MODE, ENTER THE SAME NUMERICAL MASTER CODE USED TO ENTER THE MODE. FOR SECURITY REASONS, THE PROGRAMMING MODE IS AUTOMATICALLY EXITED AFTER 30 SECONDS OF INACTIVITY. 6 PRESS OK 7 A LONG BEEP AND THE LED WHICH STOPS FLASHING WILL INDICATE THE EXIT FROM THE PROGRAMMING MODE PROGRAMMING MODE ENTRY/EXIT USING A MASTER TRANSPONDER (MOVHE MATRIX ONLY) 1 BRING A PREVIOUSLY STORED MASTER KEYCHAIN-TRANSPONDER CLOSE TO THE APPARATUS 2 ENTERING A VALID TRANSPONDER ACTIVATES THE RELAY, THE FRONT GREEN LED AND THE ACOUSTIC SIGNAL (3 SHORT BEEPS) 3 KEEP THE TRANSPONDER IN THE DETECTION FIELD OF THE APPARATUS FOR AT LEAST 5 SECONDS 4 A LONG BEEP AND THE FLASHING OF THE GREEN LED WILL INDICATE THE ENTRY INTO THE PROGRAMMING MODE. NOW IT IS POSSIBLE TO CHANGE PARAMETERS AND STORE OR DELETE USERS 5 TO EXIT FROM THE PROGRAMMING MODE, BRING THE SAME TRANSPONDER USED TO ENTER THE MODE CLOSE TO THE APPARATUS AGAIN. FOR SECURITY REASONS, THE PROGRAMMING MODE IS AUTOMATICALLY EXITED AFTER 30 SECONDS OF INACTIVITY 6 A LONG BEEP AND THE LED WHICH STOPS FLASHING WILL INDICATE THE EXIT FROM THE PROGRAMMING MODE 20

8.3 - USER STORAGE/DELETION NUMERICAL CODE STORAGE 1 ENTER THE PROGRAMMING MODE, SIGNALLED BY THE FLASHING GREEN LED 2 ENTER A NEW NUMERICAL USER CODE WITH A LENGTH EQUAL TO THE SET LENGTH 3 PRESS OK. 4 THE RED AND GREEN LEDS FLASH ALTERNATELY, SIGNALLING THAT THE CODE ENTERED IS NOT YET PRESENT IN THE MEMORY AND CAN BE STORED. IF THE CODE HAS ALREADY BEEN STORED PREVIOUSLY, ONLY THE RED LED WILL FLASH (SEE DELETION PROCEDURE) 5 SELECT: - NO TO STORE THE NEW CODE AS A MASTER USER CODE - OK TO STORE THE NEW CODE AS A STANDARD USER CODE 6 A LONG BEEP INDICATES THAT THE CODE HAS BEEN STORED. THE APPARATUS RETURNS AUTOMATICALLY TO THE PROGRAMMING MODE (GREEN LED FLASHING) TRANSPONDER STORAGE (MOVHE MATRIX ONLY) 1 ENTER THE PROGRAMMING MODE, SIGNALLED BY THE FLASHING GREEN LED 2 BRING A NEW TRANSPONDER CLOSE TO THE APPARATUS 3 THE RED AND GREEN LEDS FLASH ALTERNATELY, SIGNALLING THAT THE TRANSPONDER DETECTED IS NOT YET PRESENT IN THE MEMORY AND CAN BE STORED. IF THE TRANSPONDER HAS ALREADY BEEN STORED PREVIOUSLY, ONLY THE RED LED WILL FLASH (SEE DELETION PROCEDURE) 4 SELECT: - NO TO STORE THE NEW TRANSPONDER AS A MASTER USER CODE - OK TO STORE THE NEW TRANSPONDER AS A STANDARD USER CODE 5 A LONG BEEP INDICATES THAT THE TRANSPONDER HAS BEEN STORED. THE APPARATUS RETURNS AUTOMA- TICALLY TO THE PROGRAMMING MODE (GREEN LED FLASHING) 21

NUMERICAL CODE DELETION 1 ENTER THE PROGRAMMING MODE, SIGNALLED BY THE FLASHING GREEN LED 2 ENTER THE PREVIOUSLY STORED NUMERICAL USER CODE THAT YOU WISH TO DELETE. THIS CANNOT BE THE SAME CODE USED TO ENTER THE PROGRAMMING MODE 3 PRESS OK. 4 THE RED LED FLASHES, SIGNALLING THAT THE CODE ENTERED IS PRESENT IN THE MEMORY AND CAN BE DELETED. IF THE CODE IS NOT YET PRESENT IN THE MEMORY, THE RED AND GREEN LEDS WILL FLASH ALTER- NATELY (SEE STORAGE PROCEDURE) 5 SELECT: - NO TO CANCEL THE DELETION PROCESS - OK TO CONFIRM THE DELETION PROCESS 6 A LONG BEEP INDICATES THAT THE CODE HAS BEEN DELETED. THE APPARATUS RETURNS AUTOMATICALLY TO THE PROGRAMMING MODE (GREEN LED FLASHING) TRANSPONDER DELETION (MOVHE MATRIX ONLY) 1 ENTER THE PROGRAMMING MODE, SIGNALLED BY THE FLASHING GREEN LED 2 BRING A STORED TRANSPONDER CLOSE TO THE APPARATUS 3 THE RED LED FLASHES, SIGNALLING THAT THE TRASPONDER DETECTED IS PRESENT IN THE MEMORY AND CAN BE DELETED. IF THE TRASPONDER IS NOT YET PRESENT IN THE MEMORY, THE RED AND GREEN LEDS WILL FLASH ALTERNATELY (SEE STORAGE PROCEDURE) 4 SELECT: - NO TO CANCEL THE DELETION PROCESS - OK TO CONFIRM THE DELETION PROCESS 5 A LONG BEEP INDICATES THAT THE CODE HAS BEEN DELETED. THE APPARATUS RETURNS AUTOMATICALLY TO THE PROGRAMMING MODE (GREEN LED FLASHING) 22

23

Str. Gabannone 8/10 15030 Terruggia Tel. +39 142 403132 Fax. +39 142 403977 www.movhe.com ITALIA MANM_DIMA_EN_0_06_07