Humidity limits % RH; freezing of condensed water not allowed in reference pressure channels.

Page SATRON VT Pressure transmitter 7 SATRON VB Pressure transmitter 15

Installation and Setting-Up Instructions Spare Parts List

Siemens AG Continuous level measurement - Radar transmitters. Configuration. Mounting on a nozzle. Installation min.

Continuous level measurement Radar transmitters

FlexBar HRT Pressure Transmitter

Flow Measurement SITRANS F M

TRANSMISSOR DE PRESSÃO PIEZO RESISTIVO INTELIGENTE MICRO PROGRAMÁVEL SÉRIE PAS

Flow Measurement SITRANS F M

DMP 333 DMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial

Indicators. Hazardous-Area Indicators. 830 X R Loop-Powered 16 Process Indicator. 830 X S1 Loop-Powered 16 Process Indicator

Temperature measurement TER8 Front-flush and low-invasive resistance thermometers

Level Measurement Continuous level measurement - Ultrasonic transmitters

Application The DA03 serves as indicator of differential. Follow mounting instructions in accordance to application.

LMP 308. Separable Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO / 0.

CombiTemp TFRN/TFRH. Operating instructions. Temperature sensor. Operating Instructions: EN.

SCADAPack Modbus multivariable transmitter

NT PRESSURE TRANSDUCER MODELS 4100, 4210, 4130, 4230

Temperature Measurement SITRANS TS300

Explosion-Proof Gauge Pressure Transmitter

FlexBar 3501 Pressure Transmitter

Pressure transmitter for highest pressure applications Up to 217,500 psi (15,000 bar) Model HP-2

E Q U I C I E N H Y G E U R O P E A N

P30-2. Overview. Pressure Transmitter Datasheet. *High Quality* 3 Years Warranty. At a Glance. Function. Application

Flow Measurement SITRANS F US Inline

DS 201P. Electronic Pressure Switch. Pressure Port With Flush Welded Stainless Steel Diaphragm. accuracy according to IEC 60770: 0.

Hand-Held Pressure Indicator

SERIES 8000-SAN PRESSURE AND LEVEL TRANSMITTERS ALL STAINLESS DESCRIPTION. OUTPUT 4-20 ma / 2-WIRE ZERO AND SPAN ADJUSTABLE

Indicating Digital Transmitter for Differential Pressure and Flow. Media 6 with LCD Media 6 with LED

SCADAPack Modbus multivariable transmitter

VVP10-H HART VALVE POSITIONER. Great Performance, Compact, Robust in Severe Conditions* HART 7 Communication Protocol. Electronic Coil Technology

Safety Instructions Cerabar M PMC51, PMP51, PMP55

NIVOSWITCH VIBRATING FORK LEVEL SWITCHES

Electronic pressure switch with display Model PSD-4

selection of special materials is available to handle almost any fluid.

Instruction Manual, Alfa Laval Rotacheck Sensor and Relay

LMP 308i. Separable Stainless Steel Probe Precision. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO

Assembly. max Example: 2-wire connection IH More connection types see section electrical connections. Auxiliary voltage.

HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters

Level Measurement Continuous level measurement - Ultrasonic transmitters

Electronic pressure switch with display For sanitary applications Model PSA-31

Flow Measurement SITRANS F US Inline

Safety Instructions Cerabar S PMP71, PMP75

Level measurement CleverLevel LBFI Point level detection

HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters

LMP 308i. Separable Stainless Steel Probe Precision. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO.

914L. Capacitive Level Transmitter. Features. 1 Datasheet 914L Capacitive level transmitter for liquids.

26360, Inline. Technical data. Ordering information See page 2. For connector plugs see page 2 and data sheets N/en /2 5/2.

Flow measurement FlexFlow PF20S Flow sensor for industrial applications

Level gauges Series LS Level indicator, switch and transmitter for liquids

Variable Area Flowmeter DATASHEET

Level instruments. Point level measurement - Capacitance switches. Pointek CLS300 5/31

Miniaturised pressure sensor Model M-10, standard version Model M-11, version with flush diaphragm

SMARTLINE RM76 Supplementary instructions

Float Switches with Permanent Magnet For Vertical Installation Model RSM

Pressure transmitter PASCAL Ci4

26360, NAMUR. Technical data

Float Switches with Permanent Magnet For Horizontal Installation Model HIF

Cerabar S PMC71, PMP71, PMP ma HART, PROFIBUS PA, FOUNDATION Fieldbus

Thermocouples Model TC200, for Additional Thermowell

USB pressure transmitter model CPT2500 with model CPA2500 USB adapter and USBsoft2500 software

OPTISWITCH 6600 C Technical Datasheet

Flow Measurement SITRANS F M. Transmitter MAG 5000/ /34 Siemens FI Overview

LMP 307. Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % / 0.

Ceraphant T PTC31, PTP31, PTP35

SITRANS F C. Transmitter MASS 6000 Ex d compact/remote 3/195

HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters

TFR5. Room or outdoor temperature sensor. Operating instructions for temperature sensor. English page 1...5

Level Transmitter. Table of dimensions see page 4. Total length B Installation length A SW55 Ø 55 Ø 75

Series Pressure and Level Transmitters. Data Sheet. Overview. A Higher Level of Performance. Gladiator Acoustic Switch Series

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

Product manual plug, sockets and coupler 16 A.- Z0251

FOSTEN AUTOMATION SÉRIE F500-SRT

Inductive dual sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

T EN TROVIS Electropneumatic Positioner

97100 NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve

Intrinsically safe Hand-Held Pressure Indicator (ATEX-version) Model CPH62I0

Mass Flow Meters & Controllers

CombiView DFON Graphical display

FOR LIQUIDS AND SOLIDS

Flow Measurement SITRANS F M. Transmitter MAG 6000 I/6000 I Ex de. 3/46 Siemens FI

Vane wheel probe BFA25 for flow measurement of gases and liquids with integrated, configurable transducer UFA in Ex-d housing

Precision digital pressure gauge Model CPG1500

Inductive angle sensor with analog output Ri360P1-DSU35TC-ELi-Exi

Pressure sensor For highest pressure applications to 15,000 bar Model HP-2

Direct solenoid and solenoid pilot operated valves

Screw-Type Flow Meter SVC

Electronic pressure switch with display For sanitary applications Model PSA-31

Direct solenoid and solenoid pilot operated valves

Differential pressure transmitter PASCAL Ci4 Delta P

SRD991 Intelligent Positioner with HART, FoxCom, PROFIBUS-PA, FOUNDATION Fieldbus H1 or Without Communication

Inductive sensor with analog output BI15-M30-LI-EXI

Control IT Booster Pump Controller

C-Flow Coriolis Mass Flow Meter

FLEX Ex Spring Clamp Terminal Base

Operating instructions Electronic pressure sensor. PM205x /01 09/2011

914S. Capacitive Sanitary Pressure Transmitter. Features. 1 Datasheet 914S Capacitive Sanitary Pressure Transmitter

Instruction Manual. T3110 T3110L T3110Ex

Series 3730 Type Electropneumatic Positioner

Refer to attachment for more details. Andreas Meyer

Transcription:

SATRON VL pressure transmitter belongs to the V transmitter family. The series V transmitters have both analog and smart properties. SATRON VL is used for 1. kpa...15 MPa ranges. It is a wire transmitter with HART standard communication. In pressure measuring applications SATRON VL transmitters are used for measuring the pressure of clean, sedimenting, crystallizing and sticking materials. The transmitter's sensor is piezoresistive. The rangeability is 1:1 for types VL6 VL7. The versatile selection of diaphragm materials will meet the needs in most processes. Also the models with special accuracy are included to the series of VL transmitters. TECHNICAL SPECIFICATIONS Measuring range and span See Selection Chart. Zero and Span adjustment Zero elevation: Calibrated span is freely selectable on the specified range depending from the desired option. This can be made by using extern control shafts (analog option), keyboard (display option), HART 75/75 communicator. Damping Time constant is continuously adjustable.1 to 6 s. Temperature limits Ambient: to + C Process: to +15 C / + C Shipping and storage: to + C. Operating temperature of display: to +5ºC (does not affect operation of the transmitter) Process temperature/ C 15 1 5 Recommended application range (horizontal mounting) 6 Output wire (W), ma, user selectable for linear, square root, inverted signal or the transfer function (16 points)specified by the user ambient temperature/ C PERFORMANCE SPECIFICATIONS Tested in accordance with IEC 677: Reference conditions, specified span, no range elevation, horizontal mounting; AISI16L diaphragm, silicone oil fill Accuracy ±.5 % of calibrated span (For spans 1:15:1). For spans 5:11:1, ( ) ±[.5+.1 x max.span ]% of calibrated span calibrated span Special accurate diaphragm AISI: ±1.5 % of calibrated span (For spans 1:11:1). (incl. nonlinearity, hysteresis and repeatability) Longterm stability ±.1 % of max. span / 1 year Temperature effect on C to + C range, optional Zero and span error ±.15 % of max. span, code E ±.5 % of max. span, code G Temperature effect on + C to +7 C range, process connections BA and DA Zero and span error ±. % of max. span, code S Temperature effect on to + C, code H ±1 % of max. span Process connection PA (VL and 5): ± % of max. span Mounting position effect Deviation from horizontal position causes a zero shift that can be calibrated out. BLV M, revision 5 Vibration effect (IEC 66: FC): ±.1 % of span per g to 1 Hz. Power supply effect <±.1 % of calibrated span per volt. Insulation test voltage 5 V rms 5 Hz. CONSTRUCTION AND CALIBRATION Materials Diaphragm 1) : AISI16L (EN 1.5), AISI (EN 1.1), Duplex (EN 1.6), Hast. C 76 (EN.), Tantalum or Titanium Gr (EN.75). Other sensing element materials: AISI16L, AISI16. Fill fluid Silicone oil, inert oil or Food oil (Neobee M). Housing with PLUG connector, codes H and T Housing: AISI/16 Seals: Viton and NBR TEST jacks: MS5Sn/PVDF, protected with silicone rubber shield. PLUG connector: PA6GF jacket, Silicone rubber seal, AISI16 retaining screw. Housing with junction box/terminal strip, codes M and N Housing: AISI/16; Seals: Nitrile and Viton ; Nameplates: Polyester Connection cable between sensing element and housing Codes L and K : PTFE hose with AISI16 braiding. Calibration For customerspecified range with 1 s. damping. (If range is not specified, transmitter is calibrated for maximum range.) Enclosure class: IP66. Supply voltage and permissible load See the load capacity diagram; ma output: 15 VDC. Humidity limits 1 % RH; freezing of condensed water is not allowed in reference pressure channels. Pressure limits Minimum and maximum process pressure: see the appended tables. 1) Parts in contact with process medium. Pressure limits Pressure capacity Transmitter type VL VL VL5 VL6 VL7 Max. overload pressure, MPa.. 1.5 7.5. Pressure class, max. PN PN PN PN1 PN5 Minimum process pressure: T Min.pressure for different proc. fill fluids (kpa, abs.) C DC Inert 1 cst oil 5 1 1 1 16 15 5 5 9 Satron Instruments Inc., P.O.Box, FI91 Tampere, Finland Tel. +5 7 6, Telefax +5 7 6 1, www.satron.com

Process connections See Selection Table and dimensional drawings. Electrical connections Housing with PLUG connector, codes H and T: PLUG connector, connector type DIN 65 model AF; Pg9 gland for cable; wire crosssection.5 to 1.5 mm. Housing with junction box/terminal strip, codes M and N: Pg1.5, 1/NPT inlet; screw terminals for.5 to.5 mm wires. Weight MOUNTING TYPE DN5 Flange DN SA (Sandvik) Tx (TriClamp) PA (PMC 1") BA, VA, WA UA, VB, WB Weight / kg EXTENSION CODE 6.1.7.9 5.1 6. 7.6 7.7.1. 5. 6.1.9.6,9 1. Type M : add.5 kg and type N : add.6 kg to the specified weights. Product Certifications European Directive Information Electro Magnetic Compatibility (EMC directive /1/EC) All pressure transmitters Atex Directive (9/9/EC) Satron Instruments Inc. complies with the ATEX Directive. European Pressure Equipment Directive (PED) (97//EC) All Pressure Transmitters : Sound Engineering Practice Hazardous Locations Certifications European Certifications ATEX Intrinsic Safety Certification No. : DNV7OSL ATEX 16X II 1 GD T15 C EEx ia II C T C Tamb 5 C II GD T15 C EEx ia II C T C Tamb 5 C Input Parameters : U i = V I i = 9 ma P i =.6 W C i = 5 nf Li =. mh BLV Special Conditions for Safe Use (X) : The enclosure with plastic window and the plastic DIN65 connector must not be installed in potentially explosive atmosphere requiring category 1 apparatus. The nonconducting surface of the sensor element may be charged by the flow of nonconducting media, so there may be electrostatic hazard with IICgases. These units should be marked GD. The equipment shall be installed and connected according to the manufacturers instructions. Load / Ω 1 15 1 75 5 5 Operating region 1 1 15 5 5 Min. load using HART communication 5 Ω R max = Supply voltage 1 V I max I max =.5 ma using HART communication Supply voltage /V I max = ma (when the alarm current,5 ma is on) Supply voltage for transmitter without intrinsic safety (not ATEX) Supply voltage for transmitter with certified intrinsic safety (ATEX)

BLV ma ma + + ma Hart S PZ 1 Z.5 RUN D DN UP 6 Test 1 + + Test + Test Load 1 1 Power Wiring Housing with PLUG connector, codes H and T Load Power Wiring Housing with terminal strip, code M Load Power Wiring Housing with terminal strip, code N 1 Load Power Wiring housing N with plug DIN 65, code N/ P Keyboard : Esc = Press Esc move back towards the top of the main menu. = Use the UP arrow key to move up on the current menu level or to increase the selected parameter value. = Use the DOWN arrow key to move down on the current menu level or to decrease the selected parameter value. Enter = Press ENTER to move to a lower level in a menu or to accept a command or parameter value. Housing with display, code N Hart Z RUN S PZ 1.5 D DN UP 6 Test Use of selector switch : RUN = working position PZ = Process value zero D = Damping adjustment S = Span adjustment Z = Zero adjustment DN = Down UP = Up 1 Housing with PLUG connector, code T

Dimensional drawings (dimensions in mm) d Housing types H, T and M 5 Housing type N 65 [Atex transmitter code 1, +15] BLV Clearance for cover removal 1 k D Process connections Ax, Dx and Jx, flanged Ø6 Ø Ø115 Ø.1.15 Ø5 Ø115 Ød PG9 std. housing types H and T M x 1,5 std. housing types M and N Housing types H, T and M 1 Housing type N 15 [Atex transmitter code 1, +15] b Process connection UA Tuchenhagen DN5/ (Varinent) +.1 Es. Process connection SA Sandvikclamp xø1 Process connections DA, DN5 PN flange with extension, process temperature max. +15 C adjustable ± Code 6 E ±. d. +. E. 1 15 Process connection Ax, Dx and Jx flange with extension Es +.. 5,5 15 156 FLANGE SIZE ISO DN5 PN ISO DN5 PN ISO DN PN ISO DN1 PN ANSI 1" 15 lbs ANSI 1" lbs ANSI " 15 lbs ANSI " lbs ANSI " 15 lbs ANSI " lbs ANSI " 15 lbs ANSI " lbs JIS 1K5 JIS K5 JIS 1K JIS K JIS 1K1 JIS K1 Flange dimens. Holes Exten. b D Ød Kpl d k Ød. 1 1 1 16 5 15 16 79..9 1 15 1 5 6 1 6 16 6 1 1 6 115 165 5 1 1 15 165 1 1 9 5 155 165 15 1 1 5 6 1 1 16 9 9 17 17 157 157 96 15 16 1 1 165 5 1.6 17 15. 16..5 1 1 15 17 175 5

Dimensional drawings (dimensions in mm) Housing types H, T and M 165 Housing type N 5 [Atex transmitter code 1, +15] BLV Ø6. Process connection PA PMC 1" BA extension code L Housing types H, T and M 1 Housing type N 16 [Atex transmitter code 1, +15 and temperature code H, +] L Hex 6 7,5 7 1 Ø1,5 M5 x Ø1,5 M5x A Hex 6 Process connection BA M5x A E Process connection BB M5x with tapered Process connection VA and VB SMS and SMS Process connection WA and WB SMSSI and SMSSI Size Dimensions A 5 1 6 Thread Rd 6 x 1/6 Rd 7 x 1/6 Size SI SI 5 6 Dimensions A 1 E 7 Thread Rd 6 x 1/6 Rd 7 x 1/6 Clearance for cover removal 1 Housing types H, T and M 15 Housing type N 5 ATEX transmitter +15 11 Optio K 15 Ø D eg. DN flange min. 5 11 min. R75 Process connection TA, TB and TC Triclamp DN... 6.5 DN 6,5 5,5 6 77,5 6 PG9 std. housing types H and T M x 1,5 std. housing types M and N Remote electronics, connecting cable with protection hose, codes L and K Optio L eg. DN flange min. 5

Dimensional drawings (dimensions in mm) Ø BLV Housing with plugconnector, DIN 65, codes H and T PG9 std. housing types H and T 75 Ø Housing with junction box/terminal strip, code M M x 1,5 std. housing type M Housing with junction box/terminal strip, with display, code N 7 M x 1,5 std. housing type N Housing with junction box/terminal strip, with display and plugconnector DIN 65, code N / P 9 PG9 std. housing type N with plug DIN 65 Esc Enter

Selection Chart Adjustability ( ±) Span, min. Span, max. Measuring range VL 1.kPa (1 mbar) 5 kpa (5 mbar) 5...+5 kpa (5...5 mbar) VL kpa ( mbar) 1 kpa (1 mbar) 1...+1 kpa (1...1 mbar) VL5 1 kpa (1 mbar) 5 kpa (5 mbar) 1...+5 kpa (1...5 mbar) VLA5 1 kpa (1 mbar) 5 kpa (5 mbar) 1...+5 kpa (1...5 mbar), abs. VL6, MPa (, bar) MPa ( bar).1...+ MPa (1... bar) VLA6, MPa (, bar) MPa ( bar )...+ MPa (... bar), abs. VL7 1 MPa (1 bar) 15 MPa (15 bar)...+15 MPa (...15 bar), abs. Output S ma DC/HART protocol Process connections DA DN5 PN ISO 7 AA ANSI 1" 15 lbs ANSI B165 DB DN5 PN ISO 7 AB ANSI 1" lbs ANSI B165 DC DN PN ISO 7 AC ANSI " 15 lbs ANSI B165 DD DN1 PN ISO 7 AD ANSI " lbs ANSI B165 JA JIS 1K 5 JIS B AE ANSI " 15 lbs ANSI B165 JB JIS K 5 JIS B AF ANSI " lbs ANSI B165 JC JIS 1K JIS B AG ANSI " 15 lbs ANSI B165 JD JIS K JIS B AH ANSI " lbs ANSI B165 JE JIS 1K 1 JIS B TA Triclamp DN PN ISO 5 JF JIS K 1 JIS B TB Triclamp DN PN ISO 5 BLV Extension length (mm) (Flanged conn.) (Sandvikconn.) (not proc. conn. SA) 1 (only proc. conn. DA, DN5 PN, max. +15 C) 5.5 (not proc. conn, BB, DA, PA, Tx, UA, Vx and Wx) 7 (only proc. conn. BA, in the Pasve BA mounting) 1 15 (not proc. conn, BB, DA, PA, Tx, UA, Vx and Wx) 6 15 156 (not proc. conn, BB, DA, PA, Tx, UA, Vx and Wx) Wetted materials Diaphragm Extension or other wetted parts Code Material Code Material Code Material 1 Nickel (*) 5 Tantalum AISI16L AISI16L 6 Titanium Gr (*) Hast.C 76 Hast.C 76 Duplex (**) Duplex (EN1.6) A AISI Fill fluid S Silicon oil G Inert oil A Food and beverage special oil (Neobee M) Housing type H Housing with PLUGconnector, DIN65, no display, inlet PG9 T Housing with PLUGconnector with manual adjust, DIN65, no display, inlet PG9, (no ATEX) M Housing with junction box/terminal strip, no display, inlet Mx1,5 N Housing with junction box/terminal strip, with display, inlet Mx1,5 Explosion proof No explosion proof classification Temperature effect on C to + C range, % per max. span G ±,5% E ±,15% Temperature effect on + C to +7 C range, % per max. span S ±.% (only process connections BA and DA) Temperature effect on C to + C range, % per max. span H ±1% (not possible process connections DA1, TA, TB and TC) TC Triclamp DN6.5 PN ISO 5 UA Tuchenhagen DN5/ (Varivent) PN PA PMC 1" PN SA Sandvik DN7 PN6 VA SMS VB SMS WA SMSSI with mm extension WB SMSSI with 7 mm extension BA M5x PN16 BB M5x PN16 with 7mm extension 1 Atex Intrinsic Safety, II 1 GD T15 C (***) Process coupling (for types SA, Tx, PA and BA) Material No coupling AISI16L A With coupling Hast.C76 Duplex (1.6) Special size of electrical inlet N 1/ NPT G Pg1.5 P Plug DIN 65 Special features Special electronics (specify only if housing connected with hose to sensing element) connecting cable with protection hose L Hose protected with PTFE/AISI16 braiding, straight K Hose protected with PTFE/AISI16 braiding, angle of 9º Length of cable between sensing element and housing (specify only if housing connected with cable to sensing element) m cable m cable etc. (max. 1 m) Mounting parts for remote electronics for Ø mm tube No mounting parts 1 Mounting parts Documentation Calibration Certificate AE English Installation and Operating Instructions IE English IF Finnish Material Certificates No material certificate MC1 Raw materials certificate without appendices, in accordance with SFSEN 1.1 (DIN 59.1) standard MC Raw materials certificate for wetted parts with appendices, in accordance with SFSEN 1. (DIN 59.) standard MC Raw materials certificate for wetted parts with appendices, in accordance with SFSEN 1.1B (DIN 59.1B) standard

BLV SMSSI couplings : L1 L Coupling M5x with adjust, for process connection BA, order code M1559,5 Ød Ø6 for pipe for vessel Size L1 7 Dimensions Ød L,5 5 6 7 Thread Rd 6 x 1/6 Rd 7 x 1/6 Pasve BA working position: For process connections BA and BB 1. Transmitter in measuring. Transmitter can be checked, changed, calibrated or the transmitter diaphragm can be flushed Coupling BB M5x, for process connection BB, order code M157 (Welding assistant, code M15) 57 1.. M5x Ø6 (*) = only with flange (**) = not for range with process connection code PA (***) = Housing H and N : II GD T15 C ATEX transmitters with display are the model without membrane key. Satron Instruments Inc., P.O.Box, FI91 Tampere, Finland Tel. +5 7 6, Telefax +5 7 6 1, www.satron.com We reserve the right for technical modifications without prior notice. HART is a registered trademark of HART Communication Foundation. Viton is the registered trademark of DuPont Down Elastomers. Hastelloy is the registered trademark of Haynes International. Teflon is the registered trademark of E.I. du Pont de Nemours & Co