ZTE ZXCR Series DX In-Row Air Conditioning Product Description

Similar documents
IT Air Conditioning Units

Product Brochure DENCO Close Control Units Row-DENCO. High Density Cooling for Data Centres

Rack cooling solutions for high density racks management, from 10 to 75 kw

SmoothAir Modular Precision Cooling

IT COOLING AIR CONDITIONERS FOR HIGH DENSITY RACKS AND BLADE SERVERS. RACK COOLING SOLUTIONS FOR HIGH DENSITY RACK MANAGEMENT, FROM 4 TO 75 kw

Mission Critical Facilities & Technology Conference November 3, 2011 Cooling 101. Nick Gangemi Regional Sales Manager Data Aire

7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America

IT COOLING EVAPORATIVE COOLING SYSTEM. 2 STAGE INDIRECT ADIABATIC COOLING SYSTEM FOR LARGE DATA CENTERS FROM 80 TO 320 kw

Introducing the Heat Wheel to the Data Center

PEX (R410A) High Efficiency, Green Solution Precision Cooling for Data Centers

DATA CENTER EFFICIENCY: Data Center Temperature Set-point Impact on Cooling Efficiency

InRow Chilled Water. Up to 70kW. Close-coupled, chilled water cooling for medium to large data centers. Row-Based Cooling.

CHILLED WATER. HIGH PRECISION AIR CONDITIONERS, FROM 7 TO 211 kw

Efficiency of Data Center cooling

Combining Cold Aisle Containment with Intelligent Control to Optimize Data Center Cooling Efficiency

Cooling. Highly efficient cooling products for any IT application. For More Information: (866) DATA CENTER SOLUTIONS

Welcome Association of Energy Engineers to the Microsoft Technology Center

Passive RDHx as a Cost Effective Alternative to CRAH Air Cooling. Jeremiah Stikeleather Applications Engineer

MSYS 4480 AC Systems Winter 2015

Schneider Electric Cooling Portfolio. Jim Tubbesing Heath Wilson APC/Schneider North Texas Rep Tubbesing Solutions

Communication Register Map - Uniflair Cooling

Thermal management. Thermal management

STULZ Micro DC. with Chip-to-Atmosphere TM Liquid to Chip Cooling

PEX+ High Efficiency, Low Operating Cost Precision Solution for Data Centers

Future of Cooling High Density Equipment. Steve Madara Vice President and General Manager Liebert Precision Cooling Business Emerson Network Power

High Efficient Data Center Cooling

84 kw, Tier 3, Direct Expansion, 937 ft 2

Precision Cooling Mission Critical Air Handling Units

Ecoflair Air Economizers

Avoidable Mistakes that Compromise Cooling Performance in Data Centers and Network Rooms

Huawei Smart Cooling Solution

Cooling on Demand - scalable and smart cooling solutions. Marcus Edwards B.Sc.

Rittal Cooling Solutions A. Tropp

Variable Density, Closed-Loop, Water-Cooled Data Center Solution

Liquid Cooling Package LCP Cooling Systems

Evaporative free air cooling technology Providing evaporative free air cooling solutions.

Industry leading low energy evaporative fresh air cooling.

MEASURE MONITOR UNDERSTAND

INNOVATE DESIGN APPLY.

Liebert DCW CATALOGUE

Data Center Energy Savings By the numbers

INNOVATE DESIGN APPLY.

Virtualization and consolidation

Is Data Center Free Cooling Feasible in the Middle East? By Noriel Ong, ASEAN Eng., PMP, ATD, PQP

NREL Validates LCS Technology. PRESENTED BY Herb Zien CEO, LiquidCool Solutions

Server Room & Data Centre Energy Efficiency. Technology Paper 003

Aquaflair. Uniflair TRAC, TRAF and TRAH. Air-cooled chillers, free-cooling chillers and heat pumps with scroll compressors.

Liquid Cooling Package LCP Cooling Systems

REPORT. Energy Efficiency of the San Diego Supercomputer Center and Distributed Data Centers at UCSD. Prepared for:

TWO FINANCIAL IMPACT STUDIES. Seal IT Equipment Cabinets for Significant Annual Cost Savings and Simple Payback in a Few Short Months

How Liquid Cooling Helped Two University Data Centers Achieve Cooling Efficiency Goals. Michael Gagnon Coolcentric October

Data center cooling evolution. The hottest way to save energy. Lucio Bustaffa: Product Development Manager BlueBox Group

Next Generation Cooling

MOLLIER DIAGRAM CAN BE IMPROVED!

glide glider kw R134a air cooled liquid chillers AND free cooling chillers FREE COOLING SHELL A C CLASS E C Energy Class RCGROUP SpA

A Data Center Heat Removal System That Saves... 80% Discover Inertech s Award-winning Data Center Heat Removal System

Current Data Center Design. James Monahan Sept 19 th 2006 IEEE San Francisco ComSoc

Running Your Data Center Under Ideal Temperature Conditions

Total Modular Data Centre Solutions

HIGH DENSITY RACK COOLING CHOICES

COOLING SOLUTIONS. SmartRack Close-Coupled Cooling for IT Environments

Liebert Economizer Cooling Solutions Reduce Cooling Costs by up to 50% Without Compromising Reliability

Ten Cooling Solutions to Support High-density Server Deployment. Schneider Electric Data Center Science Center White Paper #42

Precision Cooling for Business-Critical Continuity. Liebert HPC-S. Designed for the Efficient Cooling of Small Data Centers

Close-coupled cooling

COOLING WHAT ARE THE OPTIONS AND THE PROS AND CONS FOR THE VARIOUS TYPES OF DATACENTRES SERVER AND COMMS ROOMS

Moving Containment Inside the Enclosure. Jeff Markle Great Lakes Case & Cabinet

Data Center Trends: How the Customer Drives Industry Advances and Design Development

Liebert DM. High Performance, Sensible Cooling for Small Computer Rooms and Network Closets

Liebert. icom Thermal System Controls Greater Data Center Protection, Efficiency & Insight

Liebert DSE Precision Cooling System Industry-best efficiency. Increased capacity. Ensured availability. EFFICIENCY. CAPACITY. AVAILABILITY.

Data Center Design and. Management. Steve Knipple. August 1, CTO / VP Engineering & Operations

Liebert DCW Family Chilled Water-Based High Density Cooling For The Data Center. Precision Cooling For Business-Critical Continuity

Liebert XD. Cooling Solutions For High Heat Density Applications. Precision Cooling For Business-Critical Continuity

Green Sustainable Data Centres. Checklist - EU Code of Conduct on Data Centres. Annex

Retro-Commissioning Report

Energy Logic: Emerson Network Power. A Roadmap for Reducing Energy Consumption in the Data Center. Ross Hammond Managing Director

Reducing Energy Consumption with

Data Center Energy and Cost Saving Evaluation

Data Center Optimized Controls

PROCESS & DATA CENTER COOLING. How and Why To Prepare For What s To Come JOHN MORRIS REGIONAL DIRECTOR OF SALES

4. TARGETED COOLING & AIRFLOW MANAGEMENT

Liebert. CRV Row-Based Cooling Intelligent Precision Cooling For Data Center Equipment

Liebert. AFC from 500 to 1700 kw. The Adiabatic Freecooling Solution with Top-Tier Availability

Impact of Air Containment Systems

Five Strategies for Cutting Data Center Energy Costs Through Enhanced Cooling Efficiency

Excool Indirect Adiabatic and Evaporative Data Centre Cooling World s Leading Indirect Adiabatic and Evaporative Data Centre Cooling

SMARTAISLE Intelligent, Integrated Infrastructure for the Data Center

Power & Cooling Considerations for Virtualized Environments

Reliability and extended operation

IT COOLING DATA CENTER COOLING THE MILESTONE OF GREEN DATA CENTER COOLING TECHNOLOGY

FX 2 Instruction Manual

HP Modular Cooling System: water cooling technology for high-density server installations

Liebert PDX from 15 to 120 kw

Liebert. DCL up to 35 kw. Modular Rack Cooling

PT CLIMANUSA TATA MEKADATA Citypark Business District Blok F No 05 Jl. Malibu Raya, Cengkareng Jakarta Barat Indonesia. Phone

Liebert. DCL up to 35 kw. Modular Rack Cooling

Liebert PDX from 15 to 120 kw

Liebert PDX. The Cooling Solution for Small and Medium Data Centers. Digital Scroll. Part Load. Competent Partner Efficiency

HIGH DENSITY DATACOM INTEGRATED COOLING SYSTEM.

Transcription:

ZTE ZXCR Series DX In-Row Air Conditioning Product Description

Requirements & Challenges Due to the rapid development of telecommunication technology, the related IT equipment s power consumption is increase and heat density is getting higher, therefore the demand of heat dissipation is growing. Point-to-point In-Row cooling system is an efficient solution and technology to overcome the heat density issue. The concept of In-Row system is by reducing the distance between the heat sources and cooling system to allow the cold air flow pass through the hot aisle directly. This methodology can prevent heat and hot air dissipated from the IT equipment accumulated and cycled, in the same time reduce the system PUE. ZTE ZXCR series DX In-Row cooling system adopt energy saving, low power consumption design and applicable in all scenario that required precise control of temperature and humidity condition such as data center, computer room, program controlled switching room, satellite & mobile communication stations and etc. ZTE ZXCR series divided into 300mm and 600mm standardize dimension cabinet which can provide green, energy saving, efficient, reliable, easy maintenance and integration for In-Row cooling system. Benefits and Value for Customers 1. Cooling on demand EC fan with on-demand air volume adjustment, real time temperature adjustment DX unit use inverter, automatically adjust the compression ratio base on cooling demand, to achieve the cooling capacity level. DX unit using the electronic expansion valve, adjust the refrigerant flow rate according to real time temperature, to achieve efficient precision refrigeration. 2. Energy Efficiency

Optimize the heat exchanger structure, to achieve maximum heat circulation in limited space. Air-cooled unit with air flow optimization, together with EC fan and inverter to achieve the best performance and reduce energy consumption. Water-cooled unit optimizes piping layout, together with electric two-way valve and EC fan to achieve performance and reduce the energy consumption. Cooling capacity is higher than others 5% - 10%, can use in higher demand environment and provide next generation of Green Data Center s compatible solution. 3. Intelligent Control Multiple control modes, according to customer need for different controlling parameters. Group control function, multiple units can be optimize for operation to reduce the power consumption and enhance Remote control function, unit parameters can be set and controlledremotely to avoid entry by personnel. 4. Easy Maintenance Uniform screw size, easy disassembly and maintenance. Maintenance can be performing from front end and rear end. Variable communication interface for easy troubleshooting. 5. Easy Expansion Adopt 300mm and 600mm standard cabinet size for easy expansion. Varity of power input, applicable in multiple scenario.

Product Description ZTE ZXCR DX series In-Row cooling system adopt two cooling capacity: 23 64 kw which can solve the issue of high cooling density in different environments and applications. ZXCR-3-DX ZXCR-6-DX DX unit adopts DC inverter compressor, EC fan, electronic expansion valve, electrode humidification and condensate pump and other components. By using the DC inverter compressor to compress and deliver the refrigerant to the outdoor condenser for heat circulation, expansion of electronic valve in In-Row system, intelligent EC fan, and supplemented by heating humidification to achieve precision cooling and improve cooling efficiency. With different cooling capacity 23kW, 25kW and 42kW, the in-row AC can be deployed between cabinet, installing close to the heat source, and dynamically matching data center load demand. Besides, the cooling pipe can be up the ceiling or inside the base, and is easy for maintenance from front end and rear end. With high efficiency reliability, easy installation and maintenance, the In-Row AC is widely used in different data center scenarios, providing In-Row cooling solutions for high and medium density data center. DX In-Row AC specifications: Type ZXCR-3R23 ZXCR-3R25 ZXCR-3R25-d ZXCR-6R42 Cooling Return air 23.1 25.3 25.1 42.2 capacity(kw) 37

/RH25% Return air 35 22.2 /RH25% 24.4 24.1 39.3 Input power consumption(kw) 8.3 9 8.1 15.1 Airflow(m3/h) 5000 5000 5000 10000 Electrical heater(kw) 3(Optional) 6(Optional) Humidifier(kg/h) 1.5(Optional) 3(Optional) Pipe size(mm) 25 22/12.7 22/12.7 22/15.88 FLA(A) 23.8 26.5 51.7 33.6 FLA(including heater and humidifier)(a) 28.3 31.8 42.6 Noise(dB) 65 65 65 70 Power supply 380V/3PH/50Hz 380V/3PH/50Hz 190V/3PH/61Hz 380V/3PH/50Hz Weight(kg) 145 150 150 340 2000 300 2000(2200) 300 2000(2200) 300 2000(2200) 600 Size H W D(mm) 1000 1200 1200 1200 Outdoor unit airflow (m3/h) 11400 11400 11400 19000 Outdoor unit power consumption(kw) 1.2 1.2 1.2 1.35 ZXCR Series DX structure

EC Fan G4 filter Electronic expansion valve Evaporator Inverter compressor Humidifier Application Scenarios ZXCR series DX In-Row cooling system used in Container Data Center ZXCR series DX In-Row cooling system used in Modular Data Center