CombustionMaster Control Solutions. Unique Combustion Control for Gas and/or Oil-Fired Boilers

Similar documents
T66 Central Utility Building (CUB) Control System Reliability, Optimization & Demand Management

PREPARING YOUR SYSTEMS FOR EFFICIENCY

Flamma BIOMASS COMBUSTION SYSTEM CONTROLLER. Preliminary Description V.1 Santi Moroño / Jose Caldelas / Juan R. Regueiro / 26/02/ :34

Steam Boiler Automation Using Programmable Logic Controller

USER MANUAL OF THERMAL POWER PLANT (TPP) SIMULATOR SOFTWARE

Factsheet. Power Generation Service Energy efficiency in power generation and water

Monitoring of Thermal Power Plant Using PLC and SCADA

PREFERRED. Training Schedule UTILITIES MFG CORPORATION. Dear Customers, Welcome to the Preferred Training Center!

System Overview CMS Combustion Management System

A Data Center Heat Removal System That Saves... 80% Discover Inertech s Award-winning Data Center Heat Removal System

Hawk Boiler Control. Operation Manual

Deaerator and Surge Tank Control

Studio 5000 Automation Engineering & Design Environment Enhance Productivity through Simplified System Development

The Future of Pump Controls

Compact Universal Controllers

Master Panel. Specifications. Document No. TS-2010 February 15, Product Description. Sample Specification

L17 - Introduction to the PlantPAx Process Control System for Operations and System Engineering

TURNKEY BOILER BURNER SOLUTIONS

Allen-Bradley Communications Modules Implementing network-based access control for users, devices and networks

WIRELESS REMOTE ASSET MONITORING & CONTROL

Power Quality. The Overlooked Productivity Variable

CPAE PROCESS AUTOMATION INDEX. 2 Brands of PLCs (Keyence & AB) 1 Brands of SCADA (Wonderware Intouch) Pneumatics & Field Instruments

SECTION SOLID-STATE REDUCED VOLTAGE STARTERS

POINT I/O Family. Chapter. Overview

SMARTLINE PLATFORM UPDATE Simplify, Standardize, Maximize with SmartLine

Classic PLC 5 Programmable Controllers (1785 LT, 1785 LT2, 1785 LT3, 1785 LT4) Product Data

Teaching Color-Sensing Connected Components Building Block. Quick Start

BMS Steam Station Solutions

For normal duty, design the VFD voltage level at 480 Volt, 3 Phase, 60 Hertz. (In Canada, 600 Volt, 3 Phase, 60 Hertz.)

Apprenticeship Curriculum Standard. Level 3. Trade Code: 447A

Zener Barriers Bulletin 937Z

ControlLogix Communication Modules

Features and Benefits of XeteX Controls. Other Unit Control Functions. Energy Recovery Functions

Automation of Ash Handling System with Event Logger

Infrastructure for the Architecture

March 21, Re: Life Cycle Change Notification FloBoss 407 and ROC 300 Series. ROC 300 and 407 Customers,

PLC 5 BIOTOWERS SCADA SYSTEM OPERATION MANUAL. Revision 1.0 May 15, 2006

Project Profiles. Refinery & Chemical Systems

1. Introduction. 2. Design. Safety and Emergency Stop Circuit Design Standard. Safety and Emergency Stop Circuit Design Standard.

KENTUCKY TRAINING CENTER SCHEDULE

Adapter Kit for PanelView 1200/1200e Touch Screen Terminal Cutout

Hawk 5000 Industrial Watertube Boiler Control. Operation, Service, and Parts

DDDM 45 (40-60 TPH) DDDM 60 ( TPH) COLD AGGREGATE FEEDER. Auxiliary belt No. of bins. Gathering conveyor reduction gear

Ovation Controller Model OCR1100

PowerFlex 750-Series AC Drives

Press Presse Press Presse

Accord Builder. User Guide

Operating Instructions

Thermal management. Thermal management

ASHNuN. Fundamentals of HVAC Control Systems. Robert McDowell and Ross Montgomery are the authors of the

MicroNet TMR Control System

General Specifications

System Overview Fuel/air ratio control system VMS. Sensors and systems for combustion engineering.

SCC Inc. TS-D Series. Technical Instructions. Document No. TS-3000 March 10, Deaerator, Surge and/or Condensate Control Panel.

RTU2020: Flexible Controller for Remote Solutions Paul Vellacott

Communication Protocols for Common Controls - DC-2 Modbus Communications, Devicenet Gateway Communications and SPI Communications

CTC Low Temperature Process Chillers

Observatory Automation Project

I/O Modules with EtherNet/IP Architecture

What Can You Automate? We Sell Robots

837T Solid-State Temperature Sensors

1395 Node Adapter Board Troubleshooting

CENTERLINE 2500 Motor Control Centers

T62 - Next Generation of Compact AC Drives

Training Courses AADvance & Trusted

900-TC Temperature Control Device Building Block

Color-Sensing Connected Components Building Block. Quick Start

PowerFlex 70 Safe-Off Control EtherNet/IP Guard I/O Safety Module and GuardLogix Integrated Safety Controller

FLORIDA STATE UNIVERSITY MASTER PLAN 10 Utilities

For Sale Used: 180 MW Gas Turbine Power Plant

Intelligent Motor Control Solutions Process Solutions Summit

GuardLogix Controller to Kinetix 6000 Drive with Safe-Off using EtherNet/IP CompactBlock Guard I/O Module

SIRIUS Motor Management and Control Devices

products PC Control

T52: Case Study: How FactoryTalk Products Created Success. Steve Marino Ryan Campbell Jeremy Hammons

OVERVIEW. Invensys Operations Management

ControlLogix Configurable Flowmeter Module Firmware Revision 2.4

SCC Inc. TS Series Application Guide. Technical Instructions. Document No. TS 8000 January 9, Description

Your Solution For Energy and Cost Savings. McQuay Packaged Chiller Plant

Distributed Control System Training Curriculum. PlantPAx. Distributed Control System. Improve Performance with a Complete Workforce Training Solution

Premium Monitoring System Operation and Maintenance Manual

Control Motor ECM3000

Prepared By Turki AL-Mugaiteeb Control System Engineer EASTEREN PEROCHEMICAL COMPANY SHARQ 3 rd Expansion Project (OLEFIN)

Pump Station Controller. Quick Start

PCI Expansion Slot Kit for 6181P (1500P) Series D Integrated Display Computer

712 Rev. 2.x Analyzers

712 Rev. 2.x Analyzers

POINT I/O Family. Chapter. Overview

PATENT PENDING RABBIT EARS THERMOELECTRIC GENERATOR

Catalog 25. PLANT WIDE CONTROLLER (PWC) Overview. Easy to Use. State-of-the-Art Sequencing, Monitoring and Control. Instruments & Controls

POINT I/O Family. Chapter. Overview

Annual Training plan 2018

Contents. Cabinet Components " Exploded View... 1 " Usage List U.S. Models... 2 " Usage List Canadian Models... 3 " Blank Page...

SCC Inc. TS Series. Technical Instructions. Document No. TS-2000 March 15, 2016

APPLICATIONS. Boiler / Burners Turbines Engines Incinerators Process Control Landfills Cogeneration plants

ICS COOL ENERGY THE TEMPERATURE CONTROL SPECIALISTS

-----other notes This picture was taken from here:

Computer Controlled Combustion Laboratory Unit, with SCADA TVCC

PD 527 Valve Control Module PD Series 600. Product Data Sheet February 2015 SD E06

1.0 Executive Summary. 2.0 Features and Benefits

Transcription:

CombustionMaster Control Solutions Unique Combustion Control for Gas and/or Oil-Fired Boilers

Unique Combustion Control Solution for Gas and/or Oil-Fired Boilers The CombustionMaster system from Rockwell Automation is a programmable controller-based combustion control system for use with single or multi-burner gas and/or oil-fired boilers. Each unique CombustionMaster system is capable of controlling plant and boiler firing rate, fuel-to-air ratio, excess air trim, feed-water and balanced draft. In addition to the CombustionMaster system, Rockwell Automation offers a variety of Combustion Control Solutions for boilers burning alternate fuels such as pulverized coal, lump coal or refuse-derived fuel (RDF). It can also incorporate process by-products such as liquids or gases, waste products and wood products. Benefits Enhance boiler efficiency by using feed forward control techniques and excess air trim control strategies Improve operator understanding of the combustion process by use of a graphical HMI Reduce start-up time with the receipt of a fully assembled and programmed system designed for immediate field installation Confidence that your system is in compliance with all NFPA 85 codes and standards Visualization Features To provide your operator with seamless control of their system, the HMI display panel includes dynamic graphics for operator interaction: A boiler overview graphic depicting boiler operating status Control faceplate displays for PID and motor start/stop control Process variable indicator bars display analog value Alarm status and alarm history screens Tuning display Compatibility Features By combining CombustionMaster with BurnerMaster control systems, you can build a complete industrial boiler control system using affordable programmable logic controllers. The BurnMaster control system can be retrofit with the spare rack, multi-channel I/O modules, spare displays and excess processor. By incorporating the two solutions in one unit, your systems will have: A common hardware platform that will simplify troubleshooting, shorten maintenance and operator learning curve and reduce spare parts inventory costs Common programming software that will simplify future logic changes and reduce the number of software packages that must be supported by engineering Centralized HMI terminal for operator interaction that works with either system Overall reduction in training costs associated with any new controls retrofit All hardware will exist in same enclosure If your facility has multiple boilers in addition to combustion controls, Rockwell Automation can provide a Floating Plant Master and/or Boiler Lead/Lag control. 2

System Components Your plant is unique. An experienced Rockwell Automation solutions team will design, assemble and program a CombustionMaster system for your plant s specific operational requirements. Several different hardware and programming options are available to ensure each solution is tailored to meet your needs. These include: Visualization and HMI Connected Enterprise Standard software packages Processors and I/O Power supplies and racks Industrial control hardware Non-Rockwell Automation hardware (e.g., enclosures) Documentation Integrated Architecture CombustionMaster is designed using Rockwell Automation s ControlLogix programmable logic controllers. These controllers can be din-rail mounted or placed within a 1756 I/O chassis. The input and output modules required to implement the selected control strategies are supplied with pre-fabricated cables connected to remote termination panels. Discrete and analog I/O modules are furnished as required with swing arms that are pre-wired to terminal blocks. Communication and data transfer of the system occurs over Ethernet. Each Ethernet Module in the system connects to a Stratix switch allowing for data transfer from multiple field and interfacing devices. The Connected Enterprise You can benefit from better collaboration, faster problem solving and improved innovation within your organization since the Connected Enterprise bridges operations, automation control and IT to access operational, business and transactional data. Each CombustionMaster system is connected via Ethernet allowing for high-speed communication, data transfer and process observation. Visualization (IS) A PanelView Plus operator terminal is also included in the CombustionMaster system which provides a graphical representation of the process information to the operator. From this terminal, the operator can change set points, monitor alarms, improve tuning parameters and select between automatic or manual control. Visualization products by Allen-Bradley provide windows into critical production and process information and enterprise data. 3

Standard Auxiliary Controls In addition to the CombustionMaster core control strategies, standard auxiliary controls can be easily implemented in the CombustionMaster system. These control strategies are also available to accommodate dual fuel-fired boilers with or without automatic fuel transfer or simultaneous steady firing of fuel. These include: Drum Level Control On/Off control Two element control Three element control Excess Air Trim Oxygen trim Carbon monoxide trim Induced Draft Fan Control Balanced draft control Additional Auxiliary Controls The CombustionMaster system can be easily expanded thanks to the spare processor and operator display capability included in the base system. Frequently, auxiliary boiler PID loops or discrete controls are included by using existing spare I/O channels, or by simply adding new I/O cards to the I/O chassis. System expansion can be accommodated without the need for additional panel board or rack room space. A few of the most requested auxiliary control strategies and monitored parameters include: FD and ID motor start/stop Condensate additive pump control Condensate receiving tank level control Totalization of flow parameters Indication of flue gas exit temperature Boiler drum blowdown control Deaerator level control Steam temperature control CombustionMaster Documentation The operator can take complete system ownership as soon as the CombustionMaster system is delivered since it comes with a comprehensive documentation package for both hardware and software systems. The documentation package includes: A drawing list Logic Cabinet Schematic Wiring Drawings, including symbol identification Cabinet control power distribution and system elementary wiring Logic cabinet layout drawings, including I/O module assignment, cabinet general arrangement and subpanel equipment arrangement Field device schematic connection Program ladder listing and cross reference report Product instruction documentation for major system components Alarms and System Protection The CombustionMaster system is full of preventative features that ensure your system functions as it should. It is protected by an external watchdog which adds a layer of safety in the event of a system failure. The external watchdog removes power from the fuel valves forcing them to their closed fail-safe state. In addition to the external watchdog, several process checks are incorporated to monitor device failure, process conditions, fuel conditions, and other states of the system. 4

For More Information For more information on Rockwell Automation Industrial Combustion and Steam Generation solutions, please contact your local Rockwell Automation sales representative or your local Rockwell Automation Authorized Distributor. Rockwell Automation s Industrial Combustion and Generation Solutions Team offers a full complement of burner management, combustion/temperature control and Balance of Plant solutions for all of your industrial boiler and non-boiler applications. The solutions cover all industrial fuel firing applications from single or multiple burners, single or multiple gaseous, liquid and/or solid fuels for single burner boilers and dryers through electrical utility boilers and multiple burner/multiple zone furnaces. Allen-Bradley, BurnerMaster, CombustionMaster, ControlLogix, PanelView, and Rockwell Software are trademarks of Rockwell Automation, Inc. All other trademarks and registered trademarks are property of their respective companies. Publication EMSE00-BR003C-EN-P January 2017 Supersedes Publications EMSE00-BR003B-EN-P - April 2008 Copyright 2017 Rockwell Automation, Inc. All Rights Reserved. Printed in USA.