Features Regulated Converter Description Universal input 85-64VAC <15mW No load power consumption Class II installations (without FG) -5 C to +8 C Operating temperature Continuous SCP, OCP EN/IEC/UL695, EN/IEC/UL6368 & EN6335-1 certified The RAC1-GA series are low cost AC/DC power supplies, ideal for PCB mounted, compact, board level industrial applications. They feature universal AC input voltage range, regulated and short-circuit-proof isolated DC outputs, low standby power consumption and -5 C to +8 C operating temperature range. The RAC1-GA have a built-in Class A / FCC Part 15 EMC filter, are certified to EN6335, EN695 and EN6368 safety standards and come with a three year warranty. AC/DC Converter RAC1-GA 1 Watt Single Output EMC Class A Selection Guide Part Input Output Output Efficiency Max. Capacitive Number Voltage Range Voltage Current typ (1) Load () [VAC] [VDC] [ma] [%] [µf] RAC1-5SGA 85-64 5 63 5 RAC1-1SGA 85-64 1 83 68 On Request RAC1-3.3SGA 85-64 3.3 33 63 5 RAC1-15SGA 85-64 15 66 63 RAC1-4SGA (3) 85-64 4 4 63 Note1: Measured with all input voltages at 5 C with constant resistant mode at full load Note: Max Cap Load is tested at nominal input and full resisitive load Note3: Minimum order quantity pcs Model Numbering nom. Output Power nom. Output Voltage RAC1- SGA EMC Class A Single E196683 IEC/EN695-1 certified CAN/CSA-C. No. 6368 pending UL6368-1 pending IEC/EN6368-1 pending EN6335-1 certified CB Report pending Ordering Examples: RAC1-1SGA 1Vout Single Output EMC Class A www.recom-power.com REV.: 4/18 PA-1
RAC1-GA BASIC CHARACTERISTICS Parameter Condition Min. Typ. Max. Internal Input Filter Input Voltage Range (4,5,6) nom. Vin= 85VAC 64VAC Input Current Inrush Current cold start at 5 C No load Power Consumption Input Frequency Range 47Hz 63Hz Minimum Load % Power Factor,.4.6 Start-up Time Hold-up time Internal Operating Frequency 1% load at nominal Vin 65kHz Output Ripple and Noise MHz BW C to 8 C -5 C to C 5Vout 1Vout 5Vout 1Vout Note4: No proper operation with DC input voltage Note5: The products were submitted for safety files at AC-Input operation Note6: Refer to line derating graph on page 4 5mA 18mA 3mA ma 3A 4A 15mW 1s s 18ms 8ms Pi-type 1mVp-p mvp-p mvp-p 3mVp-p Efficiency vs. Load RAC1-5SGA RAC1-1SGA 1 1 9 9 8 8 7 7 Efficiency [%] 6 5 4 3 Efficiency [%] 6 5 4 3 1 1 1 3 4 5 6 7 8 9 1 1 3 4 5 6 7 8 9 1 www.recom-power.com REV.: 4/18 PA-
RAC1-GA REGULATIONS Parameter Condition Value Output Accuracy -5 C to +8 C ±6.% max. Line Regulation -5 C to +8 C ±.% max. Load Regulation -5 C to +8 C 6.% max. Deviation vs. Load 6 RAC1-5SGA 6 RAC1-1SGA Deviation [%] 4 - Deviation [%] 4 - -4-4 -6 1 3 4 5 6 7 8 9 1-6 1 3 4 5 6 7 8 9 1 PROTECTIONS Parameter Type Value Input Fuse (7) internal fusible resistor, 1W/1W Short Circuit Protection (SCP) below 1mW continuous, auto recovery Over Voltage Category Over Current Protection (OCP) Class of Equipment 5Vout 1Vout OVCII.A -.5A, hiccup mode.5a -.91A, hiccup mode Isolation Voltage (8) I/P to O/P rated for 1 minute 3kVAC Isolation Resistance Insulation Grade Class II 1MΩ min. reinforced Leakage Current I/P to O/P.5mA max. Note7: Refer to local wiring regulations if input over-current protection is also required Note8: For repeat Hi-Pot testing, reduce the time and/or the test voltage Note9: For operation at, an external MOV is recommended. The Varistor should comply with IEC-6151-. e.g. EPCOS S14 series Protection Circuit L N FUSE U www.recom-power.com REV.: 4/18 PA-3
RAC1-GA ENVIRONMENTAL Parameter Condition Value Operating Temperature Range Maximum Case Temperature Temperature Coefficient Operating Altitude (1) @ natural convection.1m/s full load refer to derating graph -5 C to +7 C -5 C to +8 C +1 C.3%/K Operating Humidity non-condensing 5% - 9% RH max. Pollution Degree Shock 4m PD 1-15Hz, G 1min./1cycle, period 6min. each along x,y,z axes Vibration according to MIL-STD-G G/11ms pulse, 3 times at each x, y, z axes MTBF (11) according to MIL-HDBK-17F, method Derating Graph (@ Chamber and natural convection.1m/s) +5 C +7 C Line Derating 1691 x 1 3 hours 44 x 1 3 hours 1 9 8 7 6 5 4 3 1-5 -1 5 35 5 65 7 8 95 Ambient Temperature [ C] 1 9 8 7 6 5 4 3 1 85 9 64 Input Voltage [VAC] Note1: Note11: Recognized by UL for safe operation up to 4m. High altitude operation may impact the performance and lifetime. Contact TechsupportAT@recom-power.com for advice Based on calculation for 5Vout SAFETY AND CERTIFICATIONS Certificate Type (Safety) Report / File Number Standard Information Technology Equipment, General Requirements for Safety Audio/Video, information and communication technology equipment - Part1: Safety requirements Audio/Video, information and communication technology equipment - Part1: Safety requirements Household and similar electrical appliances Safety Part 1: General requirements RoHs SA18415L11 IEC695-1:5 nd Edition + Am:13 EN695-1:6 + A1:11 + A:13 www.recom-power.com REV.: 4/18 PA-4 pending pending SES1831341E continued on next page UL6368-1, nd Edition CAN/CSA-C. No. 6368-1-14 IEC6368-1:14 nd Edition EN6368-1:14+A11:17 EN6335-1:1+A11:14 RoHS 11/65/EU + AM15/863
RAC1-GA EMC Compliance Condition Standard / Criterion Electromagnetic compatibility of multimedia equipment - Emission requirements Information technology equipment - Immunity characteristics - Limits and methods of measurement EA18415E 11 EN553, Class A EN554:1+A1:15 ESD Electrostatic discharge immunity test Air ±8.kV, Contact ±4.kV EN61-4-:9, Criteria A Radiated, radio-frequency, electromagnetic field immunity test 3V/m EN61-4-3:6 + A:1, Criteria A Fast Transient and Burst Immunity AC Power Port: ±1.kV EN61-4-4:1, Criteria A Surge Immunity AC Power Port: L-N ±1.kV EN61-4-5:14, Criteria B Immunity to conducted disturbances, induced by radio-frequency fields AC Power Port 3V EN61-4-6:14, Criteria A Voltage Dips and Interruption Limits of Voltage Fluctuations & Flicker Voltage Dips >95% Voltage Dips 3% Voltage Interruptions >95% EN61-4-11:4, Criteria A EN61-4-11:4, Criteria B EN61-4-11:4, Criteria B EN61-3-3:13 EMI Filtering according to EN6335-1 / EN553 Class B Compliance L +V OUT N -V OUT CY1 CY CY1,CY Vishay 564R3TSD, SLCC X7R radial,.nf, 3kVDC ±1% DIMENSION AND PHYSICAL CHARACTERISTICS Parameter Type Value Material Dimension (LxWxH) Weight case PCB continued on next page black plastic (UL94V-) FR4 (UL94V-) 33.7 x. x 19.mm 1g typ. www.recom-power.com REV.: 4/18 PA-5
RAC1-GA Dimension Drawing (mm) 33.7 embossed logo. 19..85 1 Ø.8 ±.3 Bottom View 3.7 ±.5 7.6.54 15.4.54 3 Top View 4 4 Pin Connections Pin # Single 1 VAC in (L) VAC in (N) 3 -Vout 4 +Vout Tolerance: xx.x= ±.5mm Pin width: ±.3mm Pin length: -.5/+.9mm 3 1 8. PACKAGING INFORMATION Parameter Type Value Packaging Dimension (LxWxH) tube 47. x 36.4 x 6.4mm Packaging Quantity pcs Storage Temperature Range -5 C to +85 C Storage Humidity non-condensing 5% - 95% RH max. The product information and specifications may be subject to changes even without prior written notice.the product has been designed for various applications; its suitability lies in the responsibility of each customer. The products are not authorized for use in safety-critical applications without RECOM s explicit written consent. A safety-critical application is an application where a failure may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The applicant shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications. www.recom-power.com REV.: 4/18 PA-6