NI2400/NI816/NI4866 DATALOGGER NI2400/NI816/NI /16/24 CHANNEL ETHERNET DATA LOGGER with Embedded Web Server

Similar documents
mini CRD OMNIA _ MINI OMNIALOG READOUT UNITS AND DATALOGGERS

mini CRD OMNIA _ MINI OMNIALOG READOUT UNITS AND DATALOGGERS

WE CONNECT REAL WORLD STRUCTURAL MONITORING SMART SENSORS SOFTWARE CLOUD WIRELESS INTERFACE TO THE

RS-485 I/O Modules: ADAM-4000

I-7520: RS-232 to RS-485. Input: RS-232 protocol Output:RS-485/RS-422 Speed: Self Tuner 'inside, auto switching baud rate, 300~ BPS

WebDAQ 316. Internet Enabled Thermocouple Logger. Remote Configuration and Monitoring. Virtually Unlimited Storage. Integrated HW and SW

MPI-DN, MPI-D MULTICHANNEL ELECTRONIC RECORDER for HART or RS-485/ MODBUS RTU SENSORS

PM174 PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER. Features

12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm)

DMT345 and DMT346 Dewpoint Transmitters

D1000M SERIES FOR MODBUS SENSOR TO COMPUTER INTERFACE MODULES

X-Log Expert Data Logger

RD2000, 5.6" display. All models shown smaller than actual size.

Trident and Trident X2 Digital Process and Temperature Panel Meter

Features. :. Introduction. :. Leader 5000 Appearance. Ethernet-Based Block I/O System

C100 Portable Multifunction

BACnet Controller for General-purpose Building Applications

G801 Digital and Interconnection Logging Module for managing of monitoring systems. MAIN FIELDS OF APPLICATION

DATAWATCH IX MONITOR/RECORDER OVERVIEW FEATURES AND BENEFITS. Datasheet

Micro Motion Model 7950 and Model 7951 Signal Converters

iopac 8500 Series Rugged modular RTU controllers Overview Programmable Controllers High Sampling Rate Analog Input Prerecord Feature

The new Expert Logger 400: Industry 4.0 ready!

PBSCONTROL. AMS-R4000 Modular RTU. Remote Terminal Unit

Specifications USB-1616HS

Item SM35-J-TA22 SM43-J-TA22 SM70-J-TA22

RTU32S RTU32S Series Small Compact Utility RTU

RTU32S RTU32S Series Small Compact Utility RTU

LAUREL. Laureate Digital Panel Meter for Process and Ratiometric Signals ELECTRONICS, INC. Features. Description

Wide Bandwidth Strain Gage Input 3B18 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

8 Channel Analog Input Module Datasheet. Address / Baud rate / range configurable by the user

Samba PLC+HMI SM35-J-RA22

Select a Micro800 Controller

ProVU 4 Advanced Temperature & Process Controller

LEA_IT_DAC Datalogger CUM Instruments and Systems for Geotechnical and Structural Monitoring

Temperature/Process Controllers Manual

R1M-GH THERMOCOUPLE & DC INPUT MODULE MODEL. Remote I/O R1M Series. (16 points)

The IQ240 panel mount load cell indicator is a precision digital indicator for load cell and strain gauge applications.

The Tracker 220 Series A Complete Range of Universal Input Digital Panel Indicators for Temperature and Process Measurement

1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882

All Analog Outputs, voltage/current 20mA 35mA 5mA 48mA/30mA* *If the analog outputs are not configured, then subtract the higher value.

The IQ300 wall mount load cell indicator is a precision digital indicator for load cell and strain gauge applications.

Power Supply Input voltage 20.4VDC to 28.8VDC with less than 10% ripple Max. current consumption See Note 1

The LT1300 wall mount load cell indicator is a precision digital indicator for load cell and strain gauge applications.

OBSOLETE. Isolated, Linearized, Thermocouple Input 3B47 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Features and Benefits. Certifications

NF760 Batch Controller

LBVR1718. Description. Features channel paperless recorder

ICP DAS. ICP DAS 2013 M2M ZigBee Wireless Solutions

Dupline. Data Logger. Types G , G Product Description. Ordering Key G Type Selection. Input/Output Specifications

ADAM-6200 Series. Feature. Transition and Vision on Remote DAQ Device 19-13

- SELF-TUNING PID ALGORITHM - INTUITIVE COLOR DISPLAY WITH TEXT MESSAGING - UNIVERSAL PROCESS AND TC/RTD INPUTS - MULTI- FUNCTION RAMP- DWELL/PROCESS

User Manual. cmt-iv5 Startup Guide

ICP DAS. ICP DAS 2015 M2M WLAN Wireless Solutions

smart meters... 6 panel meters... 7 field displays... 8 display types loop powered displays TRANSMITTERS & CONVERTERS...

FEATURES DESCRIPTION SPECIFICATIONS

TRACKER 220 SERIES. Digital Panel Indicators. A Complete Range of Universal Input Digital Panel Indicators for Temperature and Process Measurement

Isolated Voltage Input 7B31 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

SX 6000 Paperless Recorder

Remote I/O Modules EH-RIO2 Series

Digital Panel Meters

StrainSmart Data Acquisition System

CPU6501 REV1.0 1 WILLOWGLEN MSC BERHAD

Ultra-Accurate Measurement for Temperature and Voltage

Ultra-Accurate Temperature Measurement Instruments

The CAL range of temperature controllers

PENKO Engineering B.V. When Weighing Counts FLEX Multi Channel Extended

WHERE THE FUTURE MEETS THE PRESENT. Datascan. solo Network Based Data Acquisition System

USER S MANUAL TP1043 series

CABINET OMNIALOG DATA ACQUISITION SYSTEMS OMNIACABXX FEATURES

iologik E2200 Series Smart Ethernet remote I/O with Click&GO Logic Introduction Remote I/O PC-Free Alarm and Control Intelligence

Isolated Process Current Input with Loop Power 7B35

Model 3724 Dual 1x30 FET Multiplexer Card

iothinx 4500 Series (45MR) Modules

ControlMaster CM15 Universal process indicator, 1 /8 DIN. Making process control easy

LAUREL. Laureate RTD Temperature Panel Meter / Controller ELECTRONICS, INC. Features. Description. Specifications

D7000 SERIES MODBUS TCP/IP ETHERNET INTERFACE MODULES

ABB Instrumentation. Specification DataFile COMMANDER 100. the-easy-to use 1. /8 DIN controller with extensive application capabilities

DMT340 Series Dewpoint and Temperature Transmitters for Very Dry Conditions

Ultra-Accurate Measurement for Temperature and Voltage

LAUREL ELECTRONICS, INC.

TRACKER 240 SERIES. Load Cell and Weighing Indicators. A Precision Measurement Instrument with Outstanding Features

6220 Ethernet-Based Voltage Measurement Module

Isolated, Voltage or Current Input 7B30 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Multi-functional precision thermometer CTR3000

Temperature Measurement Instruments Ultra-Accurate... by Design

The TRSUN is the complete solution for the remote monitoring of photovoltaic plants.

16AIO 16-Bit Analog Input/Output Board With 32 Input Channels, 4 Output Channels and 16-Bit Digital I/O Port

DATENBLATT. DT85-Serie. dex Logger Software ab Seite 14

Technical specification

PTU300 Combined Pressure, Humidity and Temperature Transmitter

C160 Wall-/Pipe Mounted Universal Process Indicator

LAUREL. Laureate Digital Panel Meter for Load Cell & Microvolt Input ELECTRONICS, INC. Features. Description

TM241CE24U controller M IO transistor NPN Ethernet

Intech Micro 2300-A8VI analogue input station MODBUS RTU slave application supplementary manual.

Intech Micro 2300-RTD6 analogue input station MODBUS RTU slave application supplementary manual.

PF2100 MODBUS LOGGER CARD SYSTEM SPECIFICATION. v1.0 DRAFT Revised Dec 4, 2014 Last Revised by Alex Messner

Z-GPRS2-SEAL THE SIMPLEST REMOTE MANAGEMENT SYSTEM FOR UNIVERSAL APPLICATIONS GSM/GPRS DATALOGGER WITH BUILT-IN I/O S AND TELECONTROL FUNCTIONS

SX90 Process Controller

TECHNICAL DATA SHEET. ProVU 4 Advanced Temperature Controller. Features. Description

MIC-2 MKII, Multi-instrument DATA SHEET

Transcription:

DATALOGGER NI2400/NI816/NI4866 8/16/24 CHANNEL ETHERNET DATA LOGGER with Embedded Web Server DATASHEET Rev. 08 del 08/10/2018 Redatto da R&D Approvato da MKT

GENERAL 1SPECIFICATIONS NI4866 NI816 NI2400 Ethernet Y Y Y Relay Output (30V 1A) 7 1 1 Digital Input (24V 10mA) 2 2 2 Analog Input Number 4-8 8-16 24 Internal Temperature Sensor Y Y Y Voltage Y Y Y Current Y Y Y mv/v Y Y Y PT100 N/Y** N/Y** Y NTC Y Y Y Vibrating Wire*** N/Y** N/Y** Y Internal CJC Sensor Y N Y Thermocouple Y N Y Switchable Power Supply N/Y** N/Y** Y (Selectable by Software: 24V, 20V, 10V, 5V) RS485 2 2 2 Power Supply RS485 Y Y Y Smart MUX* N N N RS232 Y Y Y Display 128x64 px 128x64 px 128x64 px USB HOST Y Y Y Analog Expansion with Multiplexer N Y Y DI/DO Expansion 6 IN/ 6 OUT - - Memory 2GB 2GB 2GB Software Web Server Y Y Y Cloud Dashboard Management Option Y Y Y Weight Dimensions (L x W x H) Material Wiring Calibration Operating Voltage 980g 231 x 138 x 117 mm Plastic and Metal Screws clamp termination block up to 1,3mm2 (16AWG) Recommended every 1 year 10 to 30V DC (reverse polarity protected) *Smart MUX: Allows to connect an NI100 to an NI10 and Multiplexers to read Vibrating Wire (with NTC) sensors. Up to 16 Multiplexers and 16 NI10, for a total of 384 sensors. **Depending on model ***Vibrating Vire reading is under development even if User Manual is ready for this feature. 02

GENERAL 1SPECIFICATIONS SPECIFICATIONS NI2400 Webserver on board 24 Differential Analog Input Channels Measures: Thermocouples, PT100 RTD, NTC Thermistor, mv, ma, mv/v View Data in real Time or Store to 2 GB Internal Memory GPRS Modem available 0.01% FS Accuracy Expandable up to 384 channels with multiplexers Ethernet, RS485, RS232 and USB Connections SMS and e-mail Alerts PHYSICAL CHARACTERISTICS Weight Dimensions (L x W x H) Material Wiring 980 g (2.16 lb) 231 L x 138 W x 117 mm H (9.09 x 5.43 x 4.61 ) Plastic and metal Removable screw terminal connectors 03

CPU AND MEMORY Processor RAM Memory Mass storage Clock accuracy On-board sensors ARM Cortex-M3 MCU with 1 MB Flash, 120 MHz CPU, ART Accelerator, Ethernet 1 Mbyte RAM 2 GB SD card for data (about 5 Mega data points) and Web pages High precision RTC (real time clock with battery back-up) temperature compensated Temperature (accuracy ±1%), measured inside the datalogger ANALOG INPUTS Number of Inputs: 24 differential analog inputs, individually configured. Channel expansion provided by multiplexers. There are 8 terminal blocks (each terminal block can handle up to 3 sensors). NI2400 is designed to work with 2 to 6-wire sensors. You can connect 2-wire sensors on each channel and read 24 sensors, or 4-wire sensor and read 12 channels. The system will order sensors depending on how many wires they use, placing 6 wires sensors first, 4 wires in the middle, and 2 wires last. Once software configuration is done, a click on Wiring scheme button on the web interface near the sensors will show how to physically connect the chosen sensor to the block. It shows relative position, so if you start connecting sensors from the first you will not have to leave unused positions (except for the ground connection of every block, if not used). Multiplexers are needed if the total wires from sensors exceeds the 48 provided by NI2400. 04

Analog Measurements Measurement Rate Maximum Speed Standard Speed Analog Initialization (±10V range) 1.70 sec 7.10 sec Instrument Warm-Up Depends on sensor configuration Measurement (±10V range) 80 ms 1.57 sec Accuracy: 0.13 %FS 0.01 %FS (0.1%FS for PT100 and NTC) Times indicated are not valid for vibrating wire measures Init analog phase is made only once before measurement cycle ADC: 24-bit (22 true bit) differential analog-to-digital converters, 5SPS to 1000SPS, 0-24 average function, autocalibration and auto-range ANALOG INPUT TYPES Current Loop (2 Wires) Transmitter (3-4 Wires) Voltage (4 Wires) Servo Inclinometer Wheatstone Bridge (6 Wires, With Sensing) Minimum bridge resistance 0 to 25 ma range; power supply: 24/10 Vdc, external 0 to 25 ma range; power supply: 24/10 Vdc, external ±10 mv, ±100 mv, ±1V, ±10V ranges; power supply: 24/20/10/5Vdc, external ±5V range; power supply: ± 12 Vdc (dual), external ±10mV/V range; power supply: 10/5 Vdc, external (max 10 Vdc) 200 Ω; power supply: 10/5 Vdc, external (max 10 Vdc) Potentiometer ±2.5V range; power supply: 10/5 Vdc 05

THERMOCOUPLE (LOGGER @ 25 C AMBIENT TEMPERATURE) TC TYPE RANGE ERROR TC-K From -200 C to 1370 C ±1,24 C TC-B From 600 C to 1820 C ±1,22 C TC-J From -200 C to 1200 C ±1,04 C TC-T From -200 C to 400 C ±1,99 C TC-E From -200 C to 1000 C ±0,93 C TC-R From -20 C to 1760 C ±1,64 C TC-N From -260 C to 1300 C ±1,24 C TC-S From -20 C to 1760 C ±1,64 C 06

ANALOG MEASUREMENTS RTD Input Thermistor (3000 Ω@25 C NTC) USB Device Reading Resolution Measurement Accuracy Switched Output Power Supply Platinum (Pt100/200/500/1000) RTD: range -195 to 847 C (-319 to 1556 F); maximum error ±0,17% FS; power supply: 1.2 ma range -50 to 0 C (-58 to 32 F) maximum error ±2 C (±3,6 F); range -0 to 150 C (32 to 302 F) maximum error ±1 C (±1,8 F); power supply: 0.05 ma /0.1 ma/1.2 ma USB 2.0 full speed 5V, max 500mA, USB pendrive only 1 µa at FS for 20 ma range; 1 µv at FS for ±10 mv range; 10 µv at FS for ±100 mv range; 100 µv at FS for ±1 V range; 1 mv at FS for ±10 V range; 0.1 C for Pt100 RTD; 0.1 C for NTC thermistor; 0.1 Hz for 6000 Hz range; 0.001 mv/v at FS for ±10 mv/v (Wheatstone bridge) 0.01% mv/ma FS (0.1% FS for Pt100 and NTC) - with Standard Measurement 0.13% mv/ma FS - with Max Speed Measurement Temperature Drift: < 10 ppm/ C, range -30 to 70 C Input Noise Voltage: 5.42 µv pp Input Limits : ±12V DC Common Mode Rejection: >105 db Normal Mode Rejection: >90 db Input Impedance: 20 MΩ typical The voltage V OUT is switched on and off under program control. V OUT is the unregulated input power supply V IN (2 A) 07

DIGITAL I/O Digital Output One relay output (for alarm, etc.): volt-free closure (low voltage 30V, 2A) Digital Input: Two opto-isolated digital inputs Max Input Voltage: 24V (max current: 10mA) Min Input Voltage: 5V (max current: 2mA) Measurement Rate (MR): max frequency 1 khz Accuracy: 0.1 Hz PROTECTIONS Electro-Mechanical Relays for Measuring Each Channel: Electrical Endurance: min 2 x 105 operations Mechanical Endurance: 100 x 106 operations. Circuit Protection (Gas Discharge Tubes): DC Breakdown Voltage (@100V/s): 75V Tolerance of DCBV: ± 20% Impulse Breakdown Voltage (@100v/µs ): 250V Impulse Breakdown Voltage (@1kv/µs ): 525V Overvoltage and Reverse Polarity Protection Short Circuit Protection on Every Output 08

INTERFACES Display & Keyboard LAN Ethernet Isolated RS232 USB RS485#1 Opto-Isolated RS485#2 Opto-Isolated Small backlight graphic LCD 128 x 64 dpi with membrane keyboard for the minimal local management without the PC. Keyboard for starting a data acquisition scan, sequential display of the last stored readings for each channel (sensor ID, converted unit reading, unit of measure), device status, data download and firmware/web pages update by USB pen drive, safe mode (back-up/format/restore internal SD card). 10/100 Mbps, RJ45 9-pin, DE9: DCE port for optional GSM/GPRS modem connection Baud Rates: selectable from 9600 bps to 115.2 kbps Default Format: 8 data bits; 1 stop bits; no parity USB 2.0 pen drive only (FAT 32), 5 V 200 ma Connection: 5 screw clamp port for max. No.254 Modbus RS485 digital bus sensors Communication Interface: RS485 Communication Protocol: MODBUS RTU Voltage V OUT : Switched on and off under program control. V OUT is the unregulated input power supply V IN (1 A). Power supply management: Always on or energy safe Connection: 5 screw clamp port for max. 16 multiplexer boards connection. Communication interface: RS485 Communication protocol: MODBUS RTU Voltage V OUT : Switched on and off under program control. V OUT is the unregulated input power supply V IN (1 A). Every channel of each multiplexer board is completely independent. 09

SOFTWARE & FIRMWARE SYSTEM POWER REQUIREMENTS Web server on board (independent OS platform) Acquisition Time Interval: selectable from 1 second up to 1 week (depends on the number of channels acquired) FTP client to send data/alarms on an FTP server (SFTP not supported) MAIL to send data/alarms to max 5 email address (SMTPS / SSL not supported) SMS to send alarms to max 5 telephone numbers Data download (readings, logs) in.csv file (compatible with Microsoft Excel) Virtual channels management Languages: Italian, English and French Voltage (External Power Supply) External Rechargeable Batteries Typical Current Drain (@12 Vdc, External Power Supply) Analog Initialization Measurement 10 to 30 Vdc (reverse polarity protected) 12 Vdc nominal Sleep Mode(MAX): 315 µa ON: 62 ma - ON with ethernet connected: 87 ma - ON with display ON: 115 ma ON with display ON and ethernet connected: 142 ma 115 ma 123 ma (with 12 ma @ 24 V sensor consumption) 010

ENVIROMENTAL CONDITIONS Operating Temperature Storage Temperature Relative Humidity Overvoltage Category -30 to 70 C (display -20 to 70 C) -40 to 85 C (display -30 to 80 C) 80 %RH II Pollution Degree 2 Sound Levels Maximum Height of Use < 74 dba 3000 m (9800 ft) 011

GENERAL 1SPECIFICATIONS SPECIFICATIONS NI816 Webserver on board Differential Analog Input Channels Measures: PT100 RTD, NTC Thermistor, mv, ma, mv/v View Data in real Time or Store to 2 GB Internal Memory GPRS Modem available 0.01% FS Accuracy Expandable up to 384 channels with multiplexers Ethernet, RS485, RS232 and USB Connections SMS and e-mail Alerts PHYSICAL CHARACTERISTICS Weight Dimensions (L x W x H) Material Wiring 980 g (2.16 lb) 231 L x 138 W x 117 mm H (9.09 x 5.43 x 4.61 ) Plastic and metal Removable screw terminal connectors 012

CPU AND MEMORY Processor RAM Memory Mass storage Clock accuracy On-board sensors ARM Cortex-M3 MCU with 1 MB Flash, 120 MHz CPU, ART Accelerator, Ethernet 1 Mbyte RAM 2 GB SD card for data (about 5 Mega data points) and Web pages High precision RTC (real time clock with battery back-up) temperature compensated Temperature (accuracy ±1%), measured inside the datalogger ANALOG INPUTS Number of Inputs: 8-16 differential analog inputs, individually configured. Channel expansion provided by multiplexers. There are 8 terminal blocks (each terminal block can handle up to 2 sensors). NI816 is designed to work with 2 to 6-wire sensors. Once software configuration is done, a click on Wiring scheme button on the web interface near the sensors will show how to physically connect the chosen sensor to the block. 013

Analog Measurements Measurement Rate Maximum Speed Standard Speed Analog Initialization (±10V range) 1.70 sec 7.10 sec Instrument Warm-Up Depends on sensor configuration Measurement (±10V range) 80 ms 1.57 sec Accuracy: 0.13 %FS 0.01 %FS (0.1%FS for PT100 and NTC) Times indicated are not valid for vibrating wire measures Init analog phase is made only once before measurement cycle ADC: 24-bit (22 true bit) differential analog-to-digital converters, 5SPS to 1000SPS, 0-24 average function, autocalibration and auto-range ANALOG INPUT TYPES (power supply depending on models) Current Loop (2 Wires) Transmitter (3-4 Wires) Voltage (4 Wires) Servo Inclinometer Wheatstone Bridge (6 Wires, With Sensing) Minimum bridge resistance 0 to 25 ma range; power supply: 24/10 Vdc, external 0 to 25 ma range; power supply: 24/10 Vdc, external ±10 mv, ±100 mv, ±1V, ±10V ranges; power supply: 24/20/10/5Vdc, external ±5V range; power supply: ± 12 Vdc (dual), external ±10mV/V range; power supply: 10/5 Vdc, external (max 10 Vdc) 200 Ω; power supply: 10/5 Vdc, external (max 10 Vdc) Potentiometer ±2.5V range; power supply: 10/5 Vdc 014

ANALOG MEASUREMENTS RTD Input (depending on models) Thermistor (3000 Ω@25 C NTC) USB Device Reading Resolution Measurement Accuracy Switched Output Power Supply Platinum (Pt100/200/500/1000) RTD: range -195 to 847 C (-319 to 1556 F); maximum error ±0,17% FS; power supply: 1.2 ma range -50 to 0 C (-58 to 32 F) maximum error ±2 C (±3,6 F); range -0 to 150 C (32 to 302 F) maximum error ±1 C (±1,8 F); power supply: 0.05 ma /0.1 ma/1.2 ma USB 2.0 full speed 5V, max 500mA, USB pendrive only 1 µa at FS for 20 ma range; 1 µv at FS for ±10 mv range; 10 µv at FS for ±100 mv range; 100 µv at FS for ±1 V range; 1 mv at FS for ±10 V range; 0.1 C for Pt100 RTD; 0.1 C for NTC thermistor; 0.1 Hz for 6000 Hz range; 0.001 mv/v at FS for ±10 mv/v (Wheatstone bridge) 0.01% mv/ma FS (0.1% FS for Pt100 and NTC) - with Standard Measurement 0.13% mv/ma FS - with Max Speed Measurement Temperature Drift: < 10 ppm/ C, range -30 to 70 C Input Noise Voltage: 5.42 µv pp Input Limits : ±12V DC Common Mode Rejection: >105 db Normal Mode Rejection: >90 db Input Impedance: 20 MΩ typical The voltage V OUT is switched on and off under program control. V OUT is the unregulated input power supply V IN (2 A) 015

DIGITAL I/O Digital Output One relay output (for alarm, etc.): volt-free closure (low voltage 30V, 2A) Digital Input: Two opto-isolated digital inputs Max Input Voltage: 24V (max current: 10mA) Min Input Voltage: 5V (max current: 2mA) Measurement Rate (MR): max frequency 1 khz Accuracy: 0.1 Hz PROTECTIONS Electro-Mechanical Relays for Measuring Each Channel: Electrical Endurance: min 2 x 105 operations Mechanical Endurance: 100 x 106 operations. Circuit Protection (Gas Discharge Tubes): DC Breakdown Voltage (@100V/s): 75V Tolerance of DCBV: ± 20% Impulse Breakdown Voltage (@100v/µs ): 250V Impulse Breakdown Voltage (@1kv/µs ): 525V Overvoltage and Reverse Polarity Protection Short Circuit Protection on Every Output 016

GENERAL 1SPECIFICATIONS INTERFACES Display & Keyboard LAN Ethernet Isolated RS232 USB RS485#1 Opto-Isolated RS485#2 Opto-Isolated Small backlight graphic LCD 128 x 64 dpi with membrane keyboard for the minimal local management without the PC. Keyboard for starting a data acquisition scan, sequential display of the last stored readings for each channel (sensor ID, converted unit reading, unit of measure), device status, data download and firmware/web pages update by USB pen drive, safe mode (back-up/format/restore internal SD card). 10/100 Mbps, RJ45 9-pin, DE9: DCE port for optional GSM/GPRS modem connection Baud Rates: selectable from 9600 bps to 115.2 kbps Default Format: 8 data bits; 1 stop bits; no parity USB 2.0 pen drive only (FAT 32), 5 V 200 ma Connection: 5 screw clamp port for max. No.254 Modbus RS485 digital bus sensors Communication Interface: RS485 Communication Protocol: MODBUS RTU Voltage V OUT : Switched on and off under program control. V OUT is the unregulated input power supply V IN (1 A). Power supply management: Always on or energy safe Connection: 5 screw clamp port for max. 16 multiplexer boards connection. Communication interface: RS485 Communication protocol: MODBUS RTU Voltage V OUT : Switched on and off under program control. V OUT is the unregulated input power supply V IN (1 A). Every channel of each multiplexer board is completely independent. 017

SOFTWARE & FIRMWARE SYSTEM POWER REQUIREMENTS Web server on board (independent OS platform) Acquisition Time Interval: selectable from 1 second up to 1 week (depends on the number of channels acquired) FTP client to send data/alarms on an FTP server (SFTP not supported) MAIL to send data/alarms to max 5 email address (SMTPS / SSL not supported) SMS to send alarms to max 5 telephone numbers Data download (readings, logs) in.csv file (compatible with Microsoft Excel) Virtual channels management Languages: Italian, English and French Voltage (External Power Supply) External Rechargeable Batteries Typical Current Drain (@12 Vdc, External Power Supply) Analog Initialization Measurement 10 to 30 Vdc (reverse polarity protected) 12 Vdc nominal Sleep Mode(MAX): 315 µa ON: 62 ma - ON with ethernet connected: 87 ma - ON with display ON: 115 ma ON with display ON and ethernet connected: 142 ma 115 ma 123 ma (with 12 ma @ 24 V sensor consumption) 018

ENVIROMENTAL CONDITIONS Operating Temperature Storage Temperature Relative Humidity Overvoltage Category -30 to 70 C (display -20 to 70 C) -40 to 85 C (display -30 to 80 C) 80 %RH II Pollution Degree 2 Sound Levels Maximum Height of Use < 74 dba 3000 m (9800 ft) 019

GENERAL 1SPECIFICATIONS SPECIFICATIONS NI4866 Webserver on board 4-8 Differential Analog Input Channels Measures: Thermocouples, PT100 RTD, NTC Thermistor, mv, ma, mv/v View Data in real Time or Store to 2 GB Internal Memory GPRS Modem available 0.01% FS Accuracy 6 Digital Output and 6 Digital Input expansion integrated Ethernet, RS485, RS232 and USB Connections SMS and e-mail Alerts PHYSICAL CHARACTERISTICS Weight Dimensions (L x W x H) Material Wiring 980 g (2.16 lb) 231 L x 138 W x 117 mm H (9.09 x 5.43 x 4.61 ) Plastic and metal Removable screw terminal connectors 020

CPU AND MEMORY Processor RAM Memory Mass storage Clock accuracy On-board sensors ARM Cortex-M3 MCU with 1 MB Flash, 120 MHz CPU, ART Accelerator, Ethernet 1 Mbyte RAM 2 GB SD card for data (about 5 Mega data points) and Web pages High precision RTC (real time clock with battery back-up) temperature compensated Temperature (accuracy ±1%), measured inside the datalogger ANALOG INPUTS Number of Inputs: 4-8 differential analog inputs, individually configured. Channel expansion provided by multiplexers. There are 8 terminal blocks four can maudle up to 2 sensors each, while two can mandle up to 3 di each and two can mandle (6 up to) do each. NI4866 is designed to work with 2 to 6-wire sensors. Once software configuration is done, a click on Wiring scheme button on the web interface near the sensors will show how to physically connect the chosen sensor to the block. 6 additional Digital Output and 6 additional igital Input increase applications for the device. 021

Analog Measurements Measurement Rate Maximum Speed Standard Speed Analog Initialization (±10V range) 1.70 sec 7.10 sec Instrument Warm-Up Depends on sensor configuration Measurement (±10V range) 80 ms 1.57 sec Accuracy: 0.13 %FS 0.01 %FS (0.1%FS for PT100 and NTC) Times indicated are not valid for vibrating wire measures Init analog phase is made only once before measurement cycle ADC: 24-bit (22 true bit) differential analog-to-digital converters, 5SPS to 1000SPS, 0-24 average function, autocalibration and auto-range ANALOG INPUT TYPES (power supply depending on models) Current Loop (2 Wires) Transmitter (3-4 Wires) Voltage (4 Wires) Servo Inclinometer Wheatstone Bridge (6 Wires, With Sensing) Minimum bridge resistance 0 to 25 ma range; power supply: 24/10 Vdc, external 0 to 25 ma range; power supply: 24/10 Vdc, external ±10 mv, ±100 mv, ±1V, ±10V ranges; power supply: 24/20/10/5Vdc, external ±5V range; power supply: ± 12 Vdc (dual), external ±10mV/V range; power supply: 10/5 Vdc, external (max 10 Vdc) 200 Ω; power supply: 10/5 Vdc, external (max 10 Vdc) Potentiometer ±2.5V range; power supply: 10/5 Vdc 022

THERMOCOUPLE (LOGGER @ 25 C AMBIENT TEMPERATURE) TC TYPE RANGE ERROR TC-K From -200 C to 1370 C ±1,24 C TC-B From 600 C to 1820 C ±1,22 C TC-J From -200 C to 1200 C ±1,04 C TC-T From -200 C to 400 C ±1,99 C TC-E From -200 C to 1000 C ±0,93 C TC-R From -20 C to 1760 C ±1,64 C TC-N From -260 C to 1300 C ±1,24 C TC-S From -20 C to 1760 C ±1,64 C 023

ANALOG MEASUREMENTS RTD Input (depending on models) Thermistor (3000 Ω@25 C NTC) USB Device Reading Resolution Measurement Accuracy Switched Output Power Supply Platinum (Pt100/200/500/1000) RTD: range -195 to 847 C (-319 to 1556 F); maximum error ±0,17% FS; power supply: 1.2 ma range -50 to 0 C (-58 to 32 F) maximum error ±2 C (±3,6 F); range -0 to 150 C (32 to 302 F) maximum error ±1 C (±1,8 F); power supply: 0.05 ma /0.1 ma/1.2 ma USB 2.0 full speed 5V, max 500mA, USB pendrive only 1 µa at FS for 20 ma range; 1 µv at FS for ±10 mv range; 10 µv at FS for ±100 mv range; 100 µv at FS for ±1 V range; 1 mv at FS for ±10 V range; 0.1 C for Pt100 RTD; 0.1 C for NTC thermistor; 0.1 Hz for 6000 Hz range; 0.001 mv/v at FS for ±10 mv/v (Wheatstone bridge) 0.01% mv/ma FS (0.1% FS for Pt100 and NTC) - with Standard Measurement 0.13% mv/ma FS - with Max Speed Measurement Temperature Drift: < 10 ppm/ C, range -30 to 70 C Input Noise Voltage: 5.42 µv pp Input Limits : ±12V DC Common Mode Rejection: >105 db Normal Mode Rejection: >90 db Input Impedance: 20 MΩ typical The voltage V OUT is switched on and off under program control. V OUT is the unregulated input power supply V IN (2 A) 024

DIGITAL I/O Digital Output Digital Input: 6 Relay output (for alarm, etc.): volt-free closure (low voltage 30V, 2A) One additional relay output controllable from Modbus TCP. Two opto-isolated digital inputs Max Input Voltage: 24V (max current: 10mA) Min Input Voltage: 5V (max current: 2mA) Measurement Rate (MR): max frequency 1 khz Accuracy: 0.1 Hz 6 Additional Digital Input available as trigger for acquisition and alarms. PROTECTIONS Electro-Mechanical Relays for Measuring Each Channel: Electrical Endurance: min 2 x 105 operations Mechanical Endurance: 100 x 106 operations. Circuit Protection (Gas Discharge Tubes): DC Breakdown Voltage (@100V/s): 75V Tolerance of DCBV: ± 20% Impulse Breakdown Voltage (@100v/µs ): 250V Impulse Breakdown Voltage (@1kv/µs ): 525V Overvoltage and Reverse Polarity Protection Short Circuit Protection on Every Output 025

INTERFACES Display & Keyboard LAN Ethernet Isolated RS232 USB RS485#1 Opto-Isolated Small backlight graphic LCD 128 x 64 dpi with membrane keyboard for the minimal local management without the PC. Keyboard for starting a data acquisition scan, sequential display of the last stored readings for each channel (sensor ID, converted unit reading, unit of measure), device status, data download and firmware/web pages update by USB pen drive, safe mode (back-up/format/restore internal SD card). 10/100 Mbps, RJ45 9-pin, DE9: DCE port for optional GSM/GPRS modem connection Baud Rates: selectable from 9600 bps to 115.2 kbps Default Format: 8 data bits; 1 stop bits; no parity USB 2.0 pen drive only (FAT 32), 5 V 200 ma Connection: 5 screw clamp port for max. No.254 Modbus RS485 digital bus sensors Communication Interface: RS485 Communication Protocol: MODBUS RTU Voltage V OUT : Switched on and off under program control. V OUT is the unregulated input power supply V IN (1 A). Power supply management: Always on or energy safe SOFTWARE & FIRMWARE Web server on board (independent OS platform) Acquisition Time Interval: selectable from 1 second up to 1 week (depends on the number of channels acquired) FTP client to send data/alarms on an FTP server (SFTP not supported) MAIL to send data/alarms to max 5 email address (SMTPS / SSL not supported) SMS to send alarms to max 5 telephone numbers Data download (readings, logs) in.csv file (compatible with Microsoft Excel) Virtual channels management Languages: Italian, English and French 026

SYSTEM POWER REQUIREMENTS Voltage (External Power Supply) External Rechargeable Batteries Typical Current Drain (@12 Vdc, External Power Supply) Analog Initialization Measurement 10 to 30 Vdc (reverse polarity protected) 12 Vdc nominal Sleep Mode(MAX): 315 µa ON: 62 ma - ON with ethernet connected: 87 ma - ON with display ON: 115 ma ON with display ON and ethernet connected: 142 ma 115 ma 123 ma (with 12 ma @ 24 V sensor consumption) ENVIROMENTAL CONDITIONS Operating Temperature Storage Temperature Relative Humidity Overvoltage Category -30 to 70 C (display -20 to 70 C) -40 to 85 C (display -30 to 80 C) 80 %RH II Pollution Degree 2 Sound Levels Maximum Height of Use < 74 dba 3000 m (9800 ft) 027

DATALOGGER DATALOGGERS INTERNET OF THINGS SENSORS WEB SOFTWARE Next Industries S.r.L Via G. Di Vittorio 2/F, 20065 Inzago (MI) - Italy T+39 02.95764356 info@ruggedaq.com