Resolution 1 F (1 C) single point; degrees C or Calibration single or dual point Calibration F

Similar documents
WebMaster. Cooling Tower/Boiler Controller. ONE simple and flexible controller for ALL your water treatment needs! SUMMARY OF KEY FEATURES

WebMaster WIND. Industrial Water Controller OVERVIEW SUMMARY OF KEY BENEFITS

Summary of Features and Benefits

Industrial Water Treatment Controllers

Pulse Instruments. EP500 Quick Guide Pre-configuration. EP500 Manual version 1.0

WebMaster. Cooling Tower/Boiler Controller. ONE simple and flexible controller for ALL your water treatment needs! SUMMARY OF KEY FEATURES

Industrial Water Controller Instruction Manual

Web Master. Industrial Water Controller Instruction Manual W A L C H E M. WebMaster WIND Industrial Water Controller

Web Master ONE. Water Treatment Controller Instruction Manual W A L C H E M. WebMasterONE Controllers

Web Master ONE. Water Treatment Controller Instruction Manual W A L C H E M. WebMaster ONE Controllers

TABLE OF CONTENTS 1. OVERVIEW SPECIFICATIONS UNPACKING & INSTALLATION FUNCTION OVERVIEW FUNCTION OVERVIEW...

LAKEWOOD INSTRUMENTS MODEL 1575e WATER TREATMENT CONTROLLER

200CRS Single-Channel Conductivity/Resistivity Measurement System THORNTON. Leading Pure Water Analytics

Hanna Instruments HI9819X Multiparameter series

Multiparameter Waterproof Meters. Multiparameter measurement in compact, IP67 rated waterproof enclosures

BXD17 Series. Features. Analytical instrumentation for your measurement applications.

Multiparameter Waterproof Meters. Multiparameter measurement in compact, IP67 rated waterproof enclosures

MTD75 Comprehensive cooling tower controller with all the functions required for dosing and control of cooling water

How to build a Conductivity Measurement System

Industrial. Laboratory and Field. Accessories. Product Selection Guide. Analyzers 1 Controllers 2 Transmitters 3 Monitors 4

MXD70 SERIES. Instrumentation to meet your Process Requirements. Features.

Echotouch, EchoSpan & EchoSwitch Ultrasonic Liquid

Conductivity Transmitters

CONTROLLERS. Chemical Injection skids. Water Quality Monitoring Systems cum dosing (WQMSD) Mobile Disinfection/Dosing systems

Range. Body Material. Max. Press ms K=0, C 4 bar Glass Graphite 13.5 PG Full integrated 5-meter cable

WEDT410 Series Cooling Tower Conductivity plus ph/orp Controller Instruction Manual

Controllers. Water Treatment

Pump Data Sheet - Patterson HVAC Pumps Company: Intermountain Hydron Name: Cache County Mountain Crest Date: 09/24/2018

Versatile Transmitter Series For Intelligent Measurement Solutions. INGOLD Leading Process Analytics

Neon pr. ph/ ORP measurement. Applications. Description

BL121 Pool & Spa Controller. ph/orp Swimming Pool Controller with Built-In Chemical Feed Pumps

Controllers. Metal Finishing. and Surface Treatment

Panel Indicators. NEW 4~20mA Panel Display. Process Indicators INTECH INSTRUMENTS.

BECSys7 Equipment Room Controller

Echotouch, EchoSpan & EchoSwitch Ultrasonic Liquid

LAUREL ELECTRONICS, INC.

Circuit Breaker Analyzer & Timer CAT65

770MAX Conductivity/Resistivity Sensors THORNTON. Leading Pure Water Analytics

Sensor for car parks and tunnels

WebAlert WA500 Series Process Monitor Instruction Manual

GRUNDFOS ALLDOS DATA BOOKLET. Conex DIS-C. Measuring amplifiers and controllers for conductivity measurement 50/60 Hz

Model T28 Transmitter

MST2000 Loop Powered Multivariable SMARTFLOW Transmitter

sc200 UNIVERSAL CONTROLLER Applications

Circuit Breaker Analyzer & Timer CAT66

Research Grade Meters. ph, ISE, EC and DO. Laboratory bench meters with a color, graphic display and capacitive touch keypad

WDC Series Dual Condensate Conductivity Monitor. Instruction Manual

WDT310 Series Cooling Tower Conductivity plus ph/orp Controller. Instruction Manual

GRUNDFOS DATA BOOKLET. Conex DIS-C. Measuring amplifiers and controllers. For conductivity measurement (conductive, inductive)

703 Laboratory Conductivity Meter

ERNG-X. Description. Applications. ERNG-X Specifications DERNG2108X012

Circuit Breaker Analyzer & Timer CAT31

Magnetically Actuated Safety Interlock Switches

*suitable both for membrane sensors or chlorine open cell

Smart Conductivity. Reliable and Accurate Conductivity/Resistivity Measurement. THORNTON Leading Pure Water Analytics

Circuit Breaker Analyzer & Timer CAT126

Circuit Breaker Analyzer & Timer CAT126

Process Monitor Instruction Manual

Research Grade Meters

Digital Indicator Solutions

LAUREL. Laureate Pulse or Analog Input Batch Controller Automatic batch control for repetitive liquid fill operations ELECTRONICS, INC.

TB84TE Conductivity transmitter 2-Electrode. Superior accuracy in low conductivity and pure water. applications

EL300. Multi-Channel Water Controller. Specialist Of UV Spectroscopy

SED2 Variable Frequency Drives Conventional Bypass (C-Bypass) Options

WCT Series Cooling Tower Conductivity Controller. Instruction Manual

Portavo 904 X Multi. Multiparameter Ex

Pump-Down Controller MODEL mA Input Scalable 4-20mA Output Duplex Pump Alternation Hand-Off-Auto Controls Dual Run-time Meters

F-1000 DIGITAL PADDLEWHEEL FLOWMETER

SS3000e DUAL CHANNEL H2O GAS ANALYZER KEY FEATURES NEW FEATURES. FOR NATURAL GAS Product Code 10805

LDCL DIGITAL CONTROLLER OPERATING MANUAL

700 SERIES TPC TRIPLEX PUMP CONTROLLER INSTRUCTION MANUAL

portable waterproof multiparameter meter

Double-channel measuring and control instrument for free chlorine and ph-value - additionaly ORP optional

THERMOSTATS & CONTROLLERS

Transmitter / Controller Series J dtrans ph 01, Rd 01, Lf 01, Rw 01, Az 01

General information. Display. Supply voltage. Input current. Encoder supply. Output current

The Model 703 offers a wide range of practical features to meet the numerous requirements of everyday measuring tasks.

Microprocessor Resistivity & Conductivity Monitor/Controller EC410 / EC430. Operation Manual

WDT410 Series Cooling Tower Conductivity plus ph/orp Controller Instruction Manual

HI Hydroponics Monitor HI /17 PRINTED IN USA

Control and automatic dosing

INSTRUCTION MANUAL STATION CONTROLLER SC1000 MOTOR PROTECTION ELECTRONICS, INC.

Display. Supply voltage. Input current. Encoder supply. Output current. Power losses. Memory

General information. Display. Supply voltage. Input current

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current. Encoder supply. Output current

JUMO ecotrans ph 03 Microprocessor transmitter/ switching device for ph/redox voltage and temperature

SFY Functional Safety Frequency-to-DC Transmitter with Display

Analyzer/Controller. ph/orp HART. Model 54e ph/orp ESSENTIAL INSTRUCTIONS WARNINGS RISK OF ELECTRICAL SHOCK

Level-Lance Model 5400A

General information. Display. Supply voltage. Input current. Encoder supply. Output current

Microprocessor SUNTEX EC-410/430. Conductivity Monitor

WATER TREATMENT SYSTEM CONDUCTIVITY and ph/orp CONTROLLER (With Isolation Kit)

Analog outputs Output 1 + 2: 0(4) 20 ma or 0 10 V. Configurable as - analog process value output - continuous controller output (PID action)

1.6. Counters, Panel Meters, Tachometers and Timers. Contents Description Fusion Integrated Machine Control Standards and Certifications...

Professional Waterproof Meters. ph, ph/ise, EC/TDS and DO

Plug & Play Analytical Solutions Making Basic Measurements Easy

mxcontrol Multifunction Controller

Solutions to the Most Challenging Environments

+GF+ SIGNET 5800CR Conductivity/Resistivity Monitor Instructions

Transcription:

RMS Rainwater Harvesting Series 100 Controller Specifications Measurement Performance Contacting Conductivity ph Range 0-10,000 µs/cm Range -2 to 16 ph units Resolution 1 µs/cm Resolution 0.01 ph units Calibration ± 50% of raw reading; Calibration single or dual point scalable to read in ppm Chlorine, Chlorine Dioxide or Ozone Peracetic Acid Range 0 to 10 mg/l Range 0 to 1000 mg/l Resolution 0.01 mg/l Resolution 1 mg/l Calibration single or dual point Calibration single or dual point ORP Temperature Range ± 1400 mv Range 32 to 392 F (0 to 200 C) Resolution 1 mv Resolution 1 F (1 C) single point; degrees C or Calibration single or dual point Calibration F Electrodeless Conductivity Ranges: 50 µs/cm to 1mS/cm, 1 ms/cm to 10 ms/cm, 10 ms/cm to 100 ms/cm or 100 ms to 1000 ms/cm Resolutions: 1 µs/cm or 1 ms/cm (range dependant) Calibration single or dual point; scalable to read in ppm or % concentration Electrical Input Input power Input signals 100 120/220-240 VAC ±10%, 12A, 50/60 Hz Fuse 1.6A, 5 x 20mm STANDARD Digital Inputs (A-D): Isolated dry contact (relay, reed switch or Hall Effect) (Inputs D-F for future use) 0-300 Hz,1.5 msec minimum width Digital Inputs (E-F): Isolated dry contact (relay, reed switch) (Inputs D-F for future use) 0-10 Hz, 50 msec minimum width Only Digital Inputs A-C are supported in software. D-F will be supported in the future Input signals OPTIONAL Digital Inputs (1-4) Digital Inputs (5-6) Point Level Switch: Flow Feedback: Isolated dry contact (relay, reed switch or Hall Effect) 0-10 Hz, 50 msec minimum width Isolated dry contact (relay, reed switch or Hall Effect) 0-300 Hz, 1.5 msec minimum width Isolated dry contact (relay, reed switch or Hall Effect) Isolated dry contact (relay, reed switch or Hall Effect) 4-20 ma 2-wire or 3 -wire internally powered by 24 VDC 25 ohm

resistance, 1000 ohm maximum load. Sensor STANDARD (1) Sensor OPTIONAL (3) Signal (isolated) ±1.5V Signal (isolated) ±1.5V Temp (isolated) 1K or 10K or 100K Temp (isolated) 1K or 10K or 100K ohm ohm Outputs STANDARD VAC, 10 amp (resistive), 1/8 Mechanical relays: At 115 HP At 230 VAC, 6 amp (resistive), 1/8 HP R1, R2, R3, and R4 relays are fused together as one group, total current for this group must not exceed 5.5A R5, R6, R7 and R8 relays are fused together as one group, total current for this group must not exceed 5.5A. Relays 1-8 may be dry contact or may switch line (mains) voltage, depending upon model code; refer to Figure 4. Powered relays have both NO and NC terminals available. Only powered relays are fused. Digital: USB Ethernet, 10 Base T OPTIONAL 4-20 ma (1-4): Isolated, 500 ohm max. resistive load, internally powered Agency Approvals UL ANSI/UL 61010-1:2004, 2 nd Edition * CAN/CSA C22,2 No.61010-1:2004, 2 nd Edition * CE Safety EN 61010-1 2 nd Edition (2001) * CE EMC EN 61326 :1998 Annex A * Note: For EN61000-4-3,-6 the controller met performance criteria B. Equipment suitable for use in establishments other than domestic, and those directly connected to a low voltage (100-240 VAC) power supply network which supplies buildings used for domestic purposes. Mechanical Enclosure Material: NEMA Rating: Dimensions: Display: Operating Ambient Temp: Storage Temp: Weight Molded Fiberglass NEMA 4X 10 x 12 x 5-5/8 (25.4cm x 30.5cm x 14.5cm) 64 x 128 Pixel Backlit LCD Graphics Module 0 to 49 C (32 to 120 F) -29 to 80 C (-20 to 176 F) 11.5 lb (5.2 kg) Flow switch manifold Wetted Materials of construction: 150 psi up to 100 F, 50 psi @140 F 20 to 60 C (32 to 140 F) Glass-Filled Polypropylene, PVC, FKM,

Isoplast ph Electrode ORP electrode 0 to100 psi 10 to 70 C (50 to 158 F) Glass-Filled Polypropylene, CPVC, HDPE, FKM, Glass 0 to100 psi Glass-Filled Polypropylene, CPVC, HDPE, FKM, Platinum, Glass Chlorine, Chlorine Dioxide, Ozone and Peracetic Acid sensors 0 to 1 atm (0 to 14.7 psi) Temperature (Chlorine Dioxide, Ozone and Peracetic Acid sensors): 0 to 50 C (32 to 122 F) Chlorine: 0 to 45 C (32 to 113 F) Flow Cell Inlet: ¼ NPTF Flow Cell Outlet: PVC, Silicone or PTFE, Nylon, Isoplast, FKM Contacting conductivity electrode CPVC Electrodeless conductivity sensor PEEK Electrodeless conductivity sensor 0 to 10 atm (0 to 150 psi) Glass-Filled Polypropylene, Graphite, FKM 0 to 10 atm (0 to 150 psi) Glass-Filled Polypropylene, CPVC, FKM 0 to 10 atm (0 to150 psi) 0 to 88 C (32 to 190 F) 1 NPTF PEEK Stainless steel contacting conductivity electrode 0 to 10 atm (0 to 150 psi) Glass-Filled Polypropylene, 316 SS, FKM 3 High pressure contacting conductivity electrode 0 to 20 atm (0 to 300 psi)

¾ NPTM 316 SS, PEEK High pressure/temperature contacting conductivity electrode 0 to 17 atm (0 to 250 psi) 0 to 200 C (32 to 392 F) ¾ NPTM 316 SS, PEEK High pressure ph electrode High Pressure ORP electrode 0 to 20 atm (0 to 300 psi) 0 to 135 C (32 to 275 F) ½ NPTM Glass, Polymer, PTFE, 316 SS, FKM 0 to 20 atm (0 to 300 psi) 0 to 135 C (32 to 275 F) 1/2 NPTM Platinum, Polymer, PTFE, 316 SS, FKM High Pressure flow switch 0 to 20 atm (0 to 300 psi) Carbon steel, Brass, 316SS, FKM Variables and their Limits All menus shown may not be available. The menus that appear on your controller will vary with options installed and programmed. Sensor Input Menu if ph Calibration Reminder 0-365 days -2 to 16-2 to 16 Temperature 0 to 70 C (0 to 158 F) Temperature 0 to 70 C (0 to 158 F) Sensor Input Menu if ORP Calibration Reminder 0-365 days -1400 to 1400 mv -1400 to 1400 mv Sensor Input Menu if Contacting Conductivity 4

Calibration Reminder 0 365 days ppm Conversion Factor 0.5 1.0 0 to 10,000 (units defined by user) 0 to 30,000 (units defined by user) Temperature 0 to 70 C (0 to 158 F) Temperature 0 to 70 C (0 to 158 F) Sensor Input Menu if High Temp Contacting Conductivity Calibration Reminder 0 365 days ppm Conversion Factor 0.5 1.0 0 to 10,000 (units defined by user) 0 to 30,000 (units defined by user) Temperature 0 to 200 C (32 392 F) Temperature 0 to 200 C (32 392 F) Sensor Input Menu if Electrodeless Conductivity Calibration Reminder 0 365 days ppm Conversion Factor 0.5 1.0 0 to full scale of range 0 to full scale of range Temperature 0 to 88 C (0 to 190 F) Temperature 0 to 88 C (0 to 190 F) Flowmeter Input Menu Analog Input Type Flow Rate at 4 ma 0 to 1000 (units of measure defined by user) Flow Rate at 20 ma 0 to 1000 (units of measure defined by user) Level Input Menu Analog Input Type Empty ma 0 to 20 ma Full ma 0 to 20 ma Full volume 0 to 10,000 (units defined by user) Low Level Alarm Limit 0.001 to 10,000 (units defined by user) Generic 4-20 ma Input Menu Parameter = 4 ma Parameter = 20 ma user) user) -10,000 to 10,000 (units defined by user) -10,000 to 10,000 (units defined by user) -100,000,000 to 100,000,000 (units defined by -100,000,000 to 100,000,000 (units defined by Flowmeter Input Menu Digital Input Type Volume per Contact 0 to 1000 (units of measure defined by user) K Factor 0.001 to 20,000 (Pulses per Gallon or Liter) Total Alarm Limit 0 = no limit, otherwise >0 Rate High Alarm >0 5

Rate Low Alarm >0 PosiFlow Input Menu Alarm Time Pump Volume per Stroke 0.1 to 10 minutes 0.000 to 100 (units of measure defined by user) Counter Input Menu One Count = >0 Total Alarm Limit 0 =no limit, otherwise >0 Rate High Alarm >0 Rate Low Alarm >0 Relay Output Menu On/Off Set Point Set Point Dead Band Relay Output Menu Time Proportional Set Point Sample Period Proportional Band Full scale range of the input parameter Full scale range of the input parameter 0 =, Full scale range of the input parameter Full scale range of the input parameter 0 =, Relay Output Menu Feed with Another Relay 0 =, Relay Output Menu Feed after Another Relay (Fixed Time) Fixed Time to Feed 0 to 1440 minutes Relay Output Menu Flow Based Feed Volume to trigger Feed Feed Time per unit Volume Relay Output Menu Timer Based Output On-Time 1 to 99,999 (units defined by user) 1 second to 1440 minutes 0 =, 1 to 1440 min Relay Output Menu Feed After Another Relay (%) 6

% of Relay to Feed 0 to 100% 0 =, Relay Output Menu Feed as % Time Time Period 1 1440 minutes % of Period to Feed 0.1 to 100% 0 =, Relay Output Menu DI Following On Delay Off Delay 10 seconds 1440 minutes 10 seconds 1440 minutes 0 =, Relay Output Menu - Alarm On Delay Time Power-up Alarm Delay Time 4-20 ma Output Menus 10 seconds to 1440 minutes, 0 = no limit 10 seconds to 1440 minutes, 0 = no limit 0 =, (parameter selected) = 4 ma (parameter selected) = 20 ma Maximum Output Allowed Minimum Output Allowed Input Value when Output is Max Damping Interlock Value Input Fault Value Input Cal Set Value Hand Value Full Scale Ranges are: Contacting Conductivity: Electrodeless Conductivity: Or Or Or ph: ORP: Chlorine, Chlorine Dioxide, Ozone Peracetic Acid Full scale range of the parameter Full scale range of the parameter 0 100 % 0 100% Full scale range of the parameter 0 60 seconds 0 100% 0 100% 0 100% 0 =, 0 100% 7

0 to 10,000 μs/cm 0 to 1,000 μs/cm 0 to 10,000 μs/cm 0 to 100 ms/cm 0 to 1000 ms/cm -18 to 200 C (0 to 392 F) -2 to 16 standard units -1400 to 1400 mv 0 to 10 mg/l 0 to 1000 mg/l Remote Alarming Menu Alarm Delay Time Power-up Alarm Delay Time 10 seconds to 1440 minutes, 0 = no delay 10 seconds to 1440 minutes, 0 = no delay Data Logging Menu Logging Interval 15 seconds to 1440 minutes The interval possible varies with the number of parameters logged and the maximum log duration. 8