Process Analysis Systems. Stratos Pro A4 MSPH/MSPH. Chem Energy Pharm Food Water. Connection

Similar documents
Stratos Pro A4 PH. Connection

Connection of OXY module with oxygen sensor (SE 706, Mettler Toledo InPro 6800, Hamilton Oxyferm) Model used: Stratos Pro A401N OXY/ V AC/DC

Process Analysis Systems. Stratos Pro A2 CONDI. Chem Energy Pharm Food Water. Connection

Extremely robust process analyzers with unique color-coded user interface, for all common analog and digital sensors

Portavo 921 S. Portavo S. The Basic Unit

Product Line Specifications English. Portavo 904(X) PH. Latest Product Information:

Portavo 904 X Multi. Multiparameter Ex

Stratos Pro A2... PH. Betriebsanleitung. Stratos Pro A2.. MSPH. ph Measurement. Produktinformation: User Manual.

The Art of Measuring. Multiparameter analyzers with Fieldbus technology. For analog, digital and Memosens sensors. Stratos

The Art of Measuring. User Manual English. Portavo 902 PH. Latest Product Information:

Instruction Manual DULCOMETER 2201 X ph

Stratos Pro A2... MSPH

Bargraph for quick range overview The digital indicators provide a bargraph in addition to the digital display. This gives you all information

VariTrans A The specialist for ±10 V and ±20 ma. With calibrated range selection and broad-range power supply.

Analog outputs Output 1 + 2: 0(4) 20 ma or 0 10 V. Configurable as - analog process value output - continuous controller output (PID action)

Indicators. Hazardous-Area Indicators. 830 X R Loop-Powered 16 Process Indicator. 830 X S1 Loop-Powered 16 Process Indicator

Standard-Signal Isolation Amplifiers. VariTrans A 21000

The Art of Measuring. Compact Transmitter with Modbus Interface. MemoRail Modbus

Analog outputs Output 1 + 2: 0(4) 20 ma or 0 10 V. Configurable as - analog process value output - continuous controller output (PID action)

VariTrans P The Problem The variety of tasks results in a large number of different devices.

WG 20. The WG 20 achieves an extraordinarily. accuracy for hazardous-area. applications.

Protos 3400(X) Process Analysis System

Stratos Pro A2... PH. Instruction Manual. Latest Product Information:

Modular analysis transmitter for ph/orp, conductivity measurement

Stratos Pro A4... PH Instruction Manual

SensoTrans DMS P 32200

Modular analysis transmitter for ph/orp, conductivity measurement

VariTrans B The world s first 3-port standard signal isolator in a 6-mm modular housing.

Instruction manual. ph Transmitter 2100 e/2(x)h

Instrumentation for Process Analytics

JUMO ecotrans ph 03 Microprocessor transmitter/ switching device for ph/redox voltage and temperature

SensoTrans DMS A 20220

Signal Doublers. VariTrans A 20300

The Art of Measuring. For any application: The new portable meters for ph, conductivity and oxygen. Portavo

Protos 3400(X) Process Analysis System

High-Voltage Isolation Amplifiers / Shunt Isolators. VariTrans P 42000

The Art of Measuring. Compact. Cost-efficient. Digital. Plug & Measure with the new analyzers for Memosens. MemoRail

The Art of Measuring. Stratos Evo A402. User Manual English. Conductivity Measurement. Latest Product Information:

Analyzer/Controller. ph/orp HART. Model 54e ph/orp ESSENTIAL INSTRUCTIONS WARNINGS RISK OF ELECTRICAL SHOCK

The Art of Measuring. Stratos MS A405. User Manual English. Conductivity Measurement. Latest Product Information:

Neon pr. ph/ ORP measurement. Applications. Description

The Art of Measuring. User Manual English. Portavo 904(X) PH. Latest Product Information:

Stratos Pro A2.. CC Dual Conductivity Measurement

THERMASGARD TM 65. Immersion screw-in duct temperature measuring transducer, calibratable, with multi-range switching and active output TECHNICAL DATA

The Model 703 offers a wide range of practical features to meet the numerous requirements of everyday measuring tasks.

Flow Measurement SITRANS F US Inline

Flow Measurement SITRANS F US Inline

1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882

Portavo. Portavo. Applications

ABB MEASUREMENT & ANALYTICS DATA SHEET. TB84PH ph /ORP / pion transmitter

Operation Manual MODEL 2TX. 2-wire Isolated ph/orp Transmitter

Duct Sensors. Building Technologies HVAC Products. Symaro. for relative humidity and temperature with calibration certificates

Technical Information Liquisys M CPM223/253

ph 2700i(X) module Instruction manual Order number:

FLS M9.06. ph/orp MONITOR

Versatile Transmitter Series For Intelligent Measurement Solutions. INGOLD Leading Process Analytics

703 Laboratory Conductivity Meter

Operation Manual TX10 1/8 DIN Microcomputer Based ph/orp Controller

Communication Module M 700 EC 700(X)

Portamess ph. The facts. Also available for use in hazardous area ATEX II2(1)G EEx ia IIC T4... T6, measurement in category 1 / Zone 0 possible

Stratos Eco 2405 ph. User Manual. Latest Product Information:

JUMO Quantum PID100/PID200/PID300

Immersion Temperature Sensors

Wall-/Pipe Mounted Universal Process Indicator

LBVR1718. Description. Features channel paperless recorder

FLOW MONITOR & TRANSMITTER

Portavo 908 Multi. Comprehensive Data Logger

Safety. 2. Configuration - Operation 2.1 RTD Selection 2.2 Driver Test Header. 3. Diagnostics 3.1 ph Input 3.2 Temperature Input

DINALOG A 144 x 36 A1400 Light-Strip Indicator

Indicating Digital Transmitter for Differential Pressure and Flow. Media 6 with LCD Media 6 with LED

TRANSMITTERS. HygroFlex & HygroClip-EX. Applications. Highlights

Thermo Scientific AquaPro Multi-Input Intelligent Process Analyzer

FLS M9.06 PH/ORP MONITOR. safety instructions. packing List

Room sensors QFA4160 QFA41 D AQF4150 AQF3153. Symaro. for relative humidity and temperature with calibration certificates

Measuring Module M700 ph 2700i(X)

Pressure transmitter for highest pressure applications Up to 217,500 psi (15,000 bar) Model HP-2

VariTrans P Standard-Signal Isolators

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency. Draft

MemoRail. Compact. Cost-efficient. Digital. Plug & Measure with the new analyzers for Memosens. ph ORP Cond Oxy Temp.

Signet 9900 Transmitter

PTU300 Combined Pressure, Humidity and Temperature Transmitter

Stratos Pro A4... MSCOND

Data Sheet T 6493 EN. TROVIS 6400 Automation System TROVIS 6493 Compact Controller. For panel mounting (front frame 48 x 96 mm/1.89 x 3.

Product and Applications Description. Note. Example of Operation. Installation Instructions. Application Programs WARNING

LAKEWOOD INSTRUMENTS MODEL 1575e WATER TREATMENT CONTROLLER

Dual Channel Monitor for Measurement of Speed and Ratio with SIL1 requirements Series D224.xx

ph/orp 300 (Cat. No ) MICROCOMPUTER BASED OPERATION MANUAL ph /ORP/ Temperature CONTROLLER Phone: , Fax:

Multi-range pressure and differential pressure transmitter

The Art of Measuring. The first portable devices with Memosens technology for measuring ph, conductivity and oxygen. Portavo

General information. Supply voltage. Input current. Encoder supply. Power loss. Memory

General information. Display. Supply voltage. Input current. Encoder supply. Output current

Insertion Flowmeter for compressed air and gases DN50 - DN700 (2-28 )

QUINT-PS/ 1AC/24DC/ 5

QUINT-PS AC/24DC/10

DRTS 66. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

QUINT-PS/1AC/24DC/10. Extract from the online catalog. Order No.:

OPERATION MANUAL MODEL TT-LP

C160 Wall-/Pipe Mounted Universal Process Indicator

Technical Information Liquiline To Go CYM290 and Liquiline To Go Ex CYM291

Cole-Parmer Instrument Company

Transcription:

Process Analysis Systems Chem Energy Pharm Food Water Stratos Pro A4 MSPH/MSPH Connection Connection of Memosens interface of 4-wire device with 2 Memosens sensors Model used: Stratos Pro A401N MSPH/MSPH Power supply Control room HART Module slot 20 253 V AC/DC I 0(4) 20 ma ma Meas.val./temp. II 0(4) 20 ma Stratos Pro A4 MSPH/MSPH ma Meas.val./temp. Memosens interface 0(4) 20 ma I-input Contacts Wash Alarm Limit value max. min. Hold PCS B A Control Power supply Water Sensor cleaning Alarm Max. limit value Min. limit value Terminal Assignments of Stratos Pro MSPH Module 448

For up-to-date information, please visit www.knick.de Isolation Amplifiers Transmitters Indicators Process Analytics Portable Meters Laboratory Meters Sensors Fittings Terminal Assignments of Stratos Pro 4-Wire Devices Specifications Inputs Memosens A + B digital input for Memosens ph sensors (glass or ISFET) or Memosens ORP sensors Display range ph value: 2.00 16.00 mv: 1999 1999 mv temperature: 20.0 +150.0 C ( 4 +302 F) Current input (TAN) analog, 0/4 20 ma, e.g. for flow monitoring HOLD input digital 0 2 V (AC/DC) HOLD inactive 10 30 V (AC/DC) HOLD active CONTROL input digital 0 2 V (AC/DC) flow too low 10 30 V (AC/DC) flow okay Outputs Output 1, Output 2 Process variable*} Characteristic Output filter*} 0/4 20 ma, max. 10 V, 22 ma for error message ph or mv value or temperature or differential value (CALC) linear PT1 filter, filter time constant: 0 120 s Contacts alarm, wash, limit values 1/2 Contact ratings AC < 250 V/< 3 A/< 750 VA DC < 30 V/< 3 A/< 90 W PID process controller output via limit contacts 1/2 Controller type*} pulse length controller or pulse frequency controller Sensor standardization ph*} ISFET zero offset Adaptive calibration timer adoption of calibration data from digital sensors calibration with Calimatic automatic buffer recognition manually, data entry or using the product buffer sets: Knick, Mettler Toledo, Merck/Riedel de Haen, Ciba (94), NIST, HACH, WTW, Hamilton, Reagecon, user-defined buffer table ±750 mv interval 0000 9999 h 449

Process Analysis Systems Chem Energy Pharm Food Water Stratos Pro A4 MSPH/MSPH Specifications continued Temperature compensation Process medium linear 19.99 19.99 %/K (reference temperature 25 C) Communication HART communication (TAN) HART version 6 digital communication by FSK modulation of output current 1 device identification, measured values, status and messages, parameter setting, calibration, records Diagnostics/Service Diagnostics functions Sensocheck Sensoface Logbook (TAN) Extended logbook (TAN) FDA CFR 21 Part 11 Service functions Sensor monitor Relay test IrDA interface calibration data, device self-test, display test automatic impedance monitoring of glass electrode information on the sensor condition (zero/slope, response time, calibration interval, Sensocheck, wear) 100 events with date and time Audit Trail: 200 events with date and time access control by editable passcodes logbook entry and flag via HART in the case of configuration changes message and logbook entry when enclosure is opened current source, manual controller display of direct sensor signals (mv/temperature/resistance, ) manual control of the 4 relay contacts infrared service interface for firmware updates Device data Display Keypad Power supply Real-time clock EMC Electrical safety LC display with colored backlighting, main display, secondary display, plain-text ticker line, icons, Sensoface, status indication, alarm indication keys: meas, info, 4 cursor keys, enter 24 ( 15 %) 230 (+10 %) V AC, 45 65 Hz, < 12 VA 20 80 V DC, < 4 W overvoltage category II, protection class II different time and date formats selectable power reserve > 5 days EN 61326-1 (general requirements) emitted interference: class B (residential area) immunity to interference: industry EN 61326-2-3 protection against electric shock by protective separation of all low-voltage circuits against mains according to EN 61010-1 CB report 450

For up-to-date information, please visit www.knick.de Isolation Amplifiers Transmitters Indicators Process Analytics Portable Meters Laboratory Meters Sensors Fittings Specifications continued Nominal operating conditions Ambient temperature 20 +55 C Transport/Storage temperature 20 +70 C Relative humidity Enclosure Assembly 10 95 %, not condensing molded enclosure, PBT/PC, glass-reinforced wall mounting pipe mounting: Ø 40 60 mm, _ 30 45 mm panel mounting Dimensions (mm) H x W x D: 148 x 148 x 117 Cable glands 3 knockouts for cable glands M20 x 1.5 2 knockouts for 1/2; NPT or rigid metallic conduit Control panel cutout 138 mm x 138 mm to DIN 43700 Ingress protection Weight Connections IP 67/NEMA 4X outdoor approx. 1.2 kg (1.6 kg incl. accessories and packaging) terminals, conductor cross section max. 2.5 mm *} user-defined 451

Process Analysis Systems Chem Energy Pharm Food Water Stratos Pro Simple Installation wall, post/pipe, or panel mounting all parts are easily accessible large terminal compartment pre-installation of rear unit possible also suitable for rigid metallic conduits replaceable screw terminals replacement of electronics without new cabling ZU 0274 pipe-mount kit For assembly on vertical or horizontal pipes or posts. ZU 0737 protective hood Additional protection from direct weather exposure and mechanical damage. ZU 0738 panel-mount kit For mounting in standardized panel cutout138 x 138 mm (DIN 43700), sealed against panel. 536

For up-to-date information, please visit www.knick.de Isolation Amplifiers Transmitters Indicators Process Analytics Portable Meters Laboratory Meters Sensors Fittings Dimension Drawings Front and side view 148 117 43 Rear side 34 80 148 74 6.2 Knockouts for pipe mounting (4 knockouts) Knockouts for wall mounting (2 knockouts) 14 42 42 42 Cable gland (3 x) 21 43 Knockouts for cable gland or conduit 1/2;, Ø 21.5 mm (2 knockouts) Conduits couplings not included! Pipe-mount kit ZU 0274 Ø 40 60 Panel-mount kit ZU 0738 Control panel cutout 138 x 138 mm (DIN 43700) < 30 76 31 Hose clamp with worm gear drive to DIN 3017 (2 x) Pipe-mount plate (1 x) For vertical or horizontal posts or pipes Protective hood ZU 0737 Self-tapping screw (4 x) 199 147 Threaded sleeve (4 x) 1 22 Circumferential sealing (1 x) Span piece Position (4 x) Screws (4 x) of control panel 91 185 537