DPX-620III 6-Ch. dimmer pack. user manual

Similar documents
D1210H dimmer pack. user manual

D610H, D610H MKII, D610S, D610T dimmer pack. user manual

UP-1-1 Channel Dimmer. User manual. dimmer pack

UP-1-1 Channel Dimmer dimmer pack. user manual

DDS 405 digital dimmer and switcher. user manual

DS-2 RF DMX dimmer. user manual

DDS-405 LC DMX 4 Ch. Dimmer dimmer pack. user manual

DMX Splitter 4 MKIII 19" DMX splitter. user manual

DDC-6, DDC-12 LCD DMX controller. user manual

TPC25 active crossover. user manual

LED Pixel Rail Drive 640 controller. user manual

Pixel Panel 144 RGB effect panel. user manual

HP4 headphone amplifier. user manual

D-SEED effects pedal. user manual

RevueLED 120 COB DMX LED spotlight. user manual

LED Pixel Rail 40 RGB LED strip. user manual

RevueLED 150 Profile 3200K 26 LED spotlight. user manual

LED Commander 16/2 DMX controller. user manual

SB 115A active subwoofer. user manual

HP4 headphone amplifier. user manual

LED Profile 150W 3200K. User manual. LED spotlight

PAR56 10MM UV LED PAR. user manual

TA18 active subwoofer. user manual

PowerPlant Tuner tuner pedal with power distribution. user manual

Pyrit 212 Sub A active subwoofer. user manual

LED Hellball 3 RGB LED effect. user manual

Achat 112 MA Achat 112 MA WH full-range speaker. user manual

MA100 full-range speaker. user manual

RevueLED 120 COB RGBW DMX LED spotlight. user manual

Achat 110 MA active full-range speaker. user manual

Fan-200 DMX wind machine. user manual

LED Theater Spot K. User manual. LED spotlight

650/1000 Fresnel 650/1000 PC 300/500 Antihalo 300/500 Fresnel theatre spotlight. user manual

UA-2X2 audio interface. user manual

PA18 ECO MKII passive subwoofer. user manual

MA5 active monitor. user manual

Pyrit 112 Sub A active subwoofer. user manual

Drum n Loop drum looper. user manual

Mon P10, Mon P12, Mon P15 passive monitor. user manual

xbrick Full-Colour 16 3W LED floodlight user manual

LED Colour Flood 10W / 30W RGB LED floodlight. user manual

PA12 DSP active speaker. user manual

TA12 full-rangespeaker. user manual

Hz-600 PRO Hazer DMX hazer. user manual

Harley Benton Power-Attenuator power attenuator. user manual

LED Blinder 2 COB 2 65 W blinder. user manual

201-USB Play mixer. user manual

LED Pot Strobe 100 strobe. user manual

Basic Router router. user manual

Classic Flanger effects pedal. user manual

WLAN ArtNet DMX Interface WiFi DMX controller. user manual

PAR64 CX-3 RGBW LED PAR. user manual

DSP 4x4 Mini digital speaker management. user manual

Mini Stage Par 4 7W RGBW RGB WW LED PAR. user manual

HL-x18 DCL CW/WW Flood 18x6W, HL-x9 DCL CW/WW Flood 9x6W LED floodlight. user manual

Fire Fogger 1500 fog machine. user manual

STAGE-PAR CX-2 RGBAW LED PAR. user manual

PAR64 PRO 36x3W Par56 Pro 24x3W Mini Stage Par 7x3W Stage PAR 18 Tri-Color LED3W LED PAR. user manual

LED Diamond Dome LED effect. user manual

Hz-200 DMX hazer. user manual

Achat 206 passive full-range speaker. user manual

Outdoor Stage PAR 12 3W Tri LED-PAR. user manual

MH-100 Beam 36x3 LED moving head. user manual

Stage Flood QCL 24x10W LED floodlight. user manual

Achat 115M full-range speaker. user manual

MKR 61 roll-up keyboard. user manual

HL-x18 QCL RGBW HL-x18 QCL RGB WW HL-x18 W QCL RGB WW Flood 18x8W LED floodlight. user manual

STAGE-PAR CX-2 RGBAW LED PAR. user manual

Achat 110 M passive full-range speaker. user manual

LED Matrix Blinder 5x5 DMX blinder. user manual

PA 4080 KB keyboard combo. user manual

Power Strobe 1500 DMX stroboscope. user manual

LED IP Bar 320/8 RGB DMX LED floodlight. user manual

MH-100 Beam 36x3 LED moving head. user manual

Octagon Theater CW/WW 36x1W MKII CW/WW 3W LED PAR. user manual

DSP 4x4 Mini digital speaker management. user manual

LED Bar 240/8 CW/ WW DMX LED floodlight. user manual

Stage Flood QCL 24x10W, Stage Flood Inst QCL 24x10W LED floodlight. user manual

VF-1200 DMX VertiFog CO2 FX fog machine. user manual

DMX-Master I, DMX-Master MK II ENC DMX controller. user manual

LED Pot 12 1W QCL RGB WW LED PAR. user manual

LED Derby ST. User manual. LED effect

PL 108 A / 110 A / 112 A / 115 A active 2-way speaker. user manual

MKR 61 roll-up keyboard. user manual

MS 12 active speaker. user manual

LED Matrix Blinder 5x5 DMX blinder. user manual

CLB2.4 Compact LED PAR System LED lighting set. user manual

Echolette MK I Tube amp head. user manual

Easy Move XS HP Wash. User manual. moving head

M-Fog 1000, M-Fog 1500, M-Fog 2500 fog machine. user manual

LED Pot System COB 40W RGB WW LED lighting set. user manual

MH-x30 LED Beam moving head. user manual

LED Accu Pad 7 7x10W RGBAWUV. User manual. battery spot light

Wild Wash Pro 648 LED RGB DMX, Wild Wash Pro 648 LED White DMX LED spotlight. user manual

Wild Wash 132 LED RGB DMX, 132 LED White DMX, 648 LED RGB DMX, 648 LED White DMX LED floodlight. user manual

DSP 26 digital speaker management system. user manual

SP-320 digital piano. user manual

Tri Flat PAR Profile 18x3W RGB 25, 45 LED PAR. user manual

Compact LED-Bar CLB8 LED lighting set. user manual

A 10 LA line array element. user manual

Transcription:

DPX-620III 6-Ch. dimmer pack user manual

Musikhaus Thomann Thomann GmbH Hans-Thomann-Straße 1 96138 Burgebrach Germany Telephone: +49 (0) 9546 9223-0 E-mail: info@thomann.de Internet: www.thomann.de 28.08.2017, ID: 107858

Table of contents Table of contents 1 General notes... 4 1.1 Further information... 5 1.2 Notational conventions... 6 1.3 Symbols and signal words... 7 2 Safety instructions... 9 3 Features... 14 4 Installation and starting up... 15 5 Connections and controls... 18 6 Operating... 22 7 Technical specifications... 32 8 Plug and connection assignments... 33 9 Protecting the environment... 34 DPX-620III 6-Ch. 3

General notes 1 General notes This manual contains important instructions for the safe operation of the unit. Read and follow the safety instructions and all other instructions. Keep the manual for future reference. Make sure that it is available to all those using the device. If you sell the unit please make sure that the buyer also receives this manual. Our products are subject to a process of continuous development. Thus, they are subject to change. dimmer pack 4

General notes 1.1 Further information On our website (www.thomann.de) you will find lots of further information and details on the following points: Download Keyword search Online guides Personal consultation Service This manual is also available as PDF file for you to download. Use the search function in the electronic version to find the topics of interest for you quickly. Our online guides provide detailed information on technical basics and terms. For personal consultation please contact our technical hotline. If you have any problems with the device the customer service will gladly assist you. DPX-620III 6-Ch. 5

General notes 1.2 Notational conventions This manual uses the following notational conventions: Letterings The letterings for connectors and controls are marked by square brackets and italics. Examples: [VOLUME] control, [Mono] button. Displays Texts and values displayed on the device are marked by quotation marks and italics. Examples: 24ch, OFF. dimmer pack 6

General notes Instructions The individual steps of an instruction are numbered consecutively. The result of a step is indented and highlighted by an arrow. Example: 1. Switch on the device. 2. Press [Auto]. ð Automatic operation is started. 3. Switch off the device. 1.3 Symbols and signal words In this section you will find an overview of the meaning of symbols and signal words that are used in this manual. DPX-620III 6-Ch. 7

General notes Signal word DANGER! NOTICE! Warning signs Meaning This combination of symbol and signal word indicates an immediate dangerous situation that will result in death or serious injury if it is not avoided. This combination of symbol and signal word indicates a possible dangerous situation that can result in material and environmental damage if it is not avoided. Type of danger Warning high-voltage. Warning danger zone. dimmer pack 8

Safety instructions 2 Safety instructions Intended use This appliance is designed for professional use only and is intended to be used to control the brightness of connected spotlights. Use the device only as described in this user manual. Any other use or use under other operating conditions is considered to be improper and may result in personal injury or property damage. No liability will be assumed for damages resulting from improper use. This device may be used only by persons with sufficient physical, sensorial, and intellectual abilities and having corresponding knowledge and experience. Other persons may use this device only if they are supervised or instructed by a person who is responsible for their safety. DPX-620III 6-Ch. 9

Safety instructions Safety DANGER! Danger for children Ensure that plastic bags, packaging, etc. are disposed of properly and are not within reach of babies and young children. Choking hazard! Ensure that children do not detach any small parts (e.g. knobs or the like) from the unit. They could swallow the pieces and choke! Never let children unattended use electrical devices. DANGER! Electric shock caused by high voltages inside Within the device there are areas where high voltages may be present. Never remove any covers. There are no user-serviceable parts inside. Do not use the device if covers, protectors or optical components are missing or damaged. dimmer pack 10

Safety instructions DANGER! Electric shock caused by short-circuit Do not modify the mains cable or the plug. Failure to do so could result in electric shock/death or fire. If in doubt, seek advice from a registered electrician. DANGER! Hazardous voltage Hazardous voltage may be present at cable ends and screw terminals. The connection of screw terminals as well as all maintenance and repair work on the electrical installation of the device must only be performed by qualified electrical personnel in volt-free condition. Failure to do so may result in electric shock and risk of fire and loss of life. By all means you have to observe all electrical safety instructions applicable at the place of operation. DPX-620III 6-Ch. 11

Safety instructions NOTICE! Risk of fire Do not block areas of ventilation. Do not install the device near any direct heat source. Keep the device away from naked flames. NOTICE! Operating conditions This device has been designed for indoor use only. To prevent damage, never expose the device to any liquid or moisture. Avoid direct sunlight, heavy dirt, and strong vibrations. dimmer pack 12

Safety instructions NOTICE! Power supply Before connecting the device, ensure that the input voltage (AC outlet) matches the voltage rating of the device and that the AC outlet is protected by a residual current circuit breaker. Failure to do so could result in damage to the device and possibly injure the user. Unplug the device before electrical storms occur and when it is unused for long periods of time to reduce the risk of electric shock or fire. DPX-620III 6-Ch. 13

Features 3 Features Six dimmer channels Output: 16-pin multi-pin industrial connector Digital control system Control via DMX 512 Single channel fuse (6 A) Phase correction for linear dimming Individually adjustable dimmer curve Power supply via 5-pin mains connection cable for CEE plug dimmer pack 14

Installation and starting up 4 Installation and starting up Unpack and carefully check that there is no transportation damage before using the unit. Keep the equipment packaging. To fully protect the device against vibration, dust and moisture during transportation or storage use the original packaging or your own packaging material suitable for transport or storage, respectively. Create all connections while the device is off. Use the shortest possible high-quality cables for all connections. Take care when running the cables to prevent tripping hazards. DPX-620III 6-Ch. 15

Installation and starting up DANGER! Hazardous voltage Hazardous voltage may be present at cable ends and screw terminals. The connection of screw terminals as well as all maintenance and repair work on the electrical installation of the device must only be performed by qualified electrical personnel in volt-free condition. Failure to do so may result in electric shock and risk of fire and loss of life. By all means you have to observe all electrical safety instructions applicable at the place of operation. The device is designed for mounting in 19" racks, it occupies two rack units (RU). If necessary, install a CEE plug on the power cord of the unit. First, connect the loads to the terminals on the back of the device. Establish the DMX link to the controller. Finally, connect the CEE plug of the device to a CEE socket. dimmer pack 16

Installation and starting up Connections in DMX mode Connect the DMX input of the device to the DMX output of a DMX controller or other DMX device. Connect the output of the first DMX device to the input of the second one and so on, to form a series connection. Make sure that the output of the last DMX device in the chain is terminated by a resistor (110 Ω, ¼ W). DPX-620III 6-Ch. 17

Connections and controls 5 Connections and controls Front panel dimmer pack 18

Connections and controls 1 [1] [6] Circuit breakers for channels 1 6, arranged in three blocks. With the circuit breakers, the desired channels are being activated ([I - ON]) or deactivated ([O - OFF]). 2 [DMX] The control LED lights when a DMX signal is received. 3 [1] [6] Voltage indicators of channels 1 6. The LEDs of active channels light solid green during operation. 4 Display. 5 [CH 1] [CH 6] Buttons for direct control of channels 1 6. 6 Function buttons [MENU]: Opens the main menu. [ESC]: Closes an opened menu. [UP] / [DOWN]: Navigates within a menu, increases or decreases the displayed value. DPX-620III 6-Ch. 19

Connections and controls Rear panel 7 Power cord for 5-pin CEE plug (40 A/Phase, 3 230 V). 8 Dimmer outputs, 16-pin multi-pin industrial connector (note the device label when connecting the cables). dimmer pack 20

Connections and controls 9 [DMX IN] DMX input. 10 [ANALOG] Connections to control the device by a voltage in the range 0 V 10 V. 11 [DMX OUT] DMX output DPX-620III 6-Ch. 21

Operating 6 Operating Turning on and off As soon as you connect the device to the voltage supply, the display shows the current software version, then a bar graph with the brightness set for each channel. Turn on the required channels via the associated circuit breakers (LEDs of active channels light up green). Disconnect the device from the power supply to turn it off. DANGER! Hazardous voltage Hazardous voltage may be present at cable ends and screw terminals. The connection of screw terminals as well as all maintenance and repair work on the electrical installation of the device must only be performed by qualified electrical personnel in volt-free condition. Failure to do so may result in electric shock and risk of fire and loss of life. By all means you have to observe all electrical safety instructions applicable at the place of operation. dimmer pack 22

Operating Adjusting the brightness of an individual channel Press one of the channel buttons [CH 1] [CH 6] to change the brightness. Pressing briefly results in changes with small increments, press longer for changes with larger increments. Press [ESC] to reverse the direction of change. Setting the brightness for all channels Press one of the channel buttons [UP] or [DOWN] to increase or decrease the brightness of all channels together. Pressing briefly results in changes with small increments, press longer for changes with larger increments. DPX-620III 6-Ch. 23

Operating Assigning a DMX address (patching) Proceed as follows to assign DMX addresses to the dimmer channels: 1. Press [MENU] to open the main menu. Press [UP] or [DOWN] to select the Patching menu. 2. Confirm with [MENU]. ð The display shows Patching Start. 3. Use [UP] or [DOWN] to select between assignment mode Start (channels are automatically addressed consecutively) and Independent (DMX addresses are independent of each other). Confirm with [MENU]. 4. In Start mode: Use [UP] or [DOWN] to select the DMX address of channel 1 in a rage 1 512. Confirm with [MENU]. 5. In Independent mode: Use [UP] or [DOWN] to select between All (all channels get the same DMX address) and Single (each channel can get an individual DMX address). In Independent All mode: Use [UP] or [DOWN] to select the DMX address for all channels in a rage 1 512. Confirm with [MENU]. dimmer pack 24

Operating In Independent Single mode: Use [UP] or [DOWN] to first select the channel whose DMX address is to be set. Confirm with MENU. Then select the DMX address for this channel from a range 1 512. Confirm with [MENU] and repeat the procedure for all channels. 6. Press [ESC] to return to the main menu. DPX-620III 6-Ch. 25

Operating Device behaviour on missing DMX signal. Proceed as follows to specify how the unit behaves when the DMX signal is missing. 1. Press [MENU] to open the main menu. Press [UP] or [DOWN] to select the DMX Fail menu. 2. Confirm with [MENU]. ð The display shows Dmx fail. 3. Use [UP] or [DOWN] to select between options LastHold : Last setting is retained Analog : The analogue control signal (input [ANALOG]) is analysed Progr:01-12 : The built-in automatic programmes are executed Confirm with [MENU]. 4. In Progr:01-12 mode: Use [UP] or [DOWN] to select the duration of each step (and thus the programme speed) in the range 0.005 s 30.0 s. 5. Press [ESC] to return to the main menu. dimmer pack 26

Operating Setting maximum brightness Proceed as follows to set the maximum brightness for the dimmer channels: 1. Press [MENU] to open the main menu. Press [UP] or [DOWN] to select the MaxLevel menu. 2. Confirm with [MENU]. ð The display shows MaxLevel. 3. Use [UP] or [DOWN] to select between All (all channels get the same maximum brightness) and Single (each channel can get an individual maximum brightness). Confirm with [MENU]. 4. In All mode: Use [UP] or [DOWN] to select the maximum brightness for all channels in a rage 70 % 100 %. Confirm with [MENU]. In Independent Single mode: Use [UP] or [DOWN] to first select the channel whose maximum brightness is to be set. Confirm with MENU. Then select the maximum brightness for this channel from a range 70 % 100 %. Confirm with [MENU] and repeat the procedure for all channels. 5. Press [ESC] to return to the main menu. DPX-620III 6-Ch. 27

Operating Setting minimum brightness Proceed as follows to set the minimum brightness for the dimmer channels: 1. Press [MENU] to open the main menu. Press [UP] or [DOWN] to select the MinLevel menu. 2. Confirm with [MENU]. ð The display shows MinLevel. 3. Use [UP] or [DOWN] to select between All (all channels get the same minimum brightness) and Single (each channel can get an individual minimum brightness). Confirm with [MENU]. 4. In All mode: Use [UP] or [DOWN] to select the minimum brightness for all channels in a rage 0 % 30 %. Confirm with [MENU]. In Single mode: Use [UP] or [DOWN] to first select the channel whose minimum brightness is to be set. Confirm with MENU. Then select the minimum brightness for this channel from a range 0 % 30 %. Confirm with [MENU] and repeat the procedure for all channels. 5. Press [ESC] to return to the main menu. dimmer pack 28

Operating Setting the dimmer curve Proceed as follows to adjust the dimmer curve of the dimmer channels: 1. Press [MENU] to open the main menu. Press [UP] or [DOWN] to select the Curve menu. 2. Confirm with [MENU]. ð The display shows Curve. 3. Use [UP] or [DOWN] to select between All (all channels get the same dimmer curve) and Single (each channel can get an individual dimmer curve). Confirm with [MENU]. 4. In All mode: Use [UP] or [DOWN] to select the dimmer curve from the options: Linear S Curve Non Dim Square Confirm with [MENU]. In Single mode: Use [UP] or [DOWN] to first select the channel whose dimmer curve is to be set. Confirm with MENU. Then select the dimmer curve for this channel from the options: Linear DPX-620III 6-Ch. 29

Operating S Curve Non Dim Square Confirm with [MENU] and repeat the procedure for all channels. 5. Press [ESC] to return to the main menu. dimmer pack 30

Operating Menu overview DPX-620III 6-Ch. 31

Technical specifications 7 Technical specifications Operating supply voltage AC 230 V 50 Hz Electrical connection Channel fuse Signal input Outputs Dimensions (W H D) Weight Three-phase connection, max. 40 A per phase 1 circuit breaker per channel, 6 A DMX 512 via 3-pin XLR socket 16-pin multi-pin industrial connector 482 mm 88 mm 325 mm 13.5 kg dimmer pack 32

Plug and connection assignments 8 Plug and connection assignments Introduction This chapter will help you select the right cables and plugs to connect your valuable equipment so that a perfect light experience is guaranteed. Please take our tips, because especially in Sound & Light caution is indicated: Even if a plug fits into a socket, the result of an incorrect connection may be a destroyed DMX controller, a short circuit or just a not working light show! DMX connections The unit offers a 3-pin XLR socket for DMX output and a 3-pin XLR plug for DMX input. Please refer to the drawing and table below for the pin assignment of a suitable XLR plug. Pin Configuration 1 Ground, shielding 2 Signal inverted (DMX, cold signal ) 3 Signal (DMX+, hot signal ) DPX-620III 6-Ch. 33

Protecting the environment 9 Protecting the environment Disposal of the packaging material For the transport and protective packaging, environmentally friendly materials have been chosen that can be supplied to normal recycling. Ensure that plastic bags, packaging, etc. are properly disposed of. Do not just dispose of these materials with your normal household waste, but make sure that they are collected for recycling. Please follow the notes and markings on the packaging. Disposal of your old device This product is subject to the European Waste Electrical and Electronic Equipment Directive (WEEE). Do not dispose with your normal household waste. Dispose of this device through an approved waste disposal firm or through your local waste facility. When discarding the device, comply with the rules and regulations that apply in your country. If in doubt, consult your local waste disposal facility. dimmer pack 34

Musikhaus Thomann Hans-Thomann-Straße 1 96138 Burgebrach Germany www.thomann.de