Modbus Communications Board

Similar documents
Modbus Communications Board

Intrinsically Safe Temperature Concentrator System

INTEGRATED SYSTEMS AND CONTROL, INC. User s Hardware Manual. PCMNET V 7. xx

Carbon Monoxide Sensor - ModBus

Chapter. Modbus. In This Chapter...

SERIES CMT CARBON MONOXIDE GAS TRANSMITTER

H704-42(H)(E), H704-42/1(H)(E)

MicroTech III Applied Terminal Systems BACnet MS/TP Communication Module

MODBUS MANUAL For the AccUView UV Transmission Monitor

HPS-M -2 DIFFERENTIAL PRESSURE TRANSMITTER. Mounting and operating instructions

INSTALLATION MANUAL. Gateway EKBMSMBA EKBMSBNA

Combustion gas and odorous gases within the room (smoke, body odor, timber dope Gas detected

USER GUIDE PEL / PEL-M

MTII4200 Level Transmitter Installation, Operation & Maintenance Instructions

A36D/TPSD DNP 3.0 & Modbus SCADA INTERFACE

DSTHM-2 COMBINED T AND RH DUCT TRANSMITTER. Mounting and operating instructions

Product Specification for SAB-S-MODBUS

Model 700 Remote Sensor/Alarm Relay Module

USER GUIDE PEL 8K / PEL 8K-M

KTA-250 Anemometer Alarm Card

HI 6600 series Quick Start Guide

MX200 SERIES Modbus Card 50P GE Zenith Controls. Operation and Maintenance Manual 50R-2200B 12/00

Control Techniques Variable-Speed Drive (VSD) Interface to E2 v and Above

Communications Quick-Start Guide

MC CO MODBUS ADDRESSABLE SENSOR

CTS-M5 TOXIC GAS TRANSMITTER/SENSOR INSTALLATION OPERATION AND MAINTENANCE MANUAL. Automation Components, Inc.

MEV Limited USB232/485 INSTRUCTION MANUAL

INSTRUCTION MANUAL STATION CONTROLLER SC1000 MOTOR PROTECTION ELECTRONICS, INC.

HART USER GUIDE FOR GASSONIC OBSERVER-H ULTRASONIC GAS LEAK DETECTOR

QEL - DEDESCO 5935 Ottawa Street Richmond, Ontario, Canada, K0A 2Z0.

I-7570 Serial To HART Converter

DNP 3.0 & Modbus SCADA INTERFACE INSTRUCTIONS FOR 205T BASED SYSTEMS

ABB Drives. User s Manual RS-485 Adapter Board FRSA-00

Revision 1.2. July 24, COM Protocol Manual. for MDC and ADC N 11th St - San Jose CA

Model IR4000M. HART Field Device Specification Multi-Point Monitor. Instruction Manual 07-08

Appendix to the Operating Instructions RMx621 with ModBus Interface V Connection to ModBus-IDA System

Time Mark Corporation Model 42A Pump Controller User s Guide

MGate 5105-MB-EIP Quick Installation Guide

Hello Angles... A First Use Guide to the SOLAR Product Series: RS485 Interface with ModBus RTU Communication Protocol.

MODBUS RTU I/O Expansion Modules - Models C267, C277, and C287. Installation and Operations Manual Section 50

T80 Universal Transmitter S80 Intelligent Sensors

MicroTech III Water Source Heat Pump BACnet MS/TP Communication Module

APPENDIX B SERIAL I/O MODULE INSTALLATION / OPERATION WHEN USING T&D VER. 5.2 OR 5.3

Carbon Monoxide Transmitter

MGate MB3000 Modbus Gateway User Manual

URC Utility Relay Company

5450 NW 33rd Ave, Suite 104 Fort Lauderdale, FL Fruitland Ave Los Angeles, CA UM Channel Monitor.

CDN502 HIGH DENSITY I/O ADAPTER USER GUIDE

Series 370 Stabil-Ion Gauge Controller with RS-485 Interface Option

Using the MODBUS Protocol with Athena Series C (1ZC, 16C, 18C, and 25C) Controllers

CDD ModBus Carbon Dioxide Detector

EX & EX-45362IS 2S RS232/422/485 3-in-1 Serial PCIe Card

GW-7228 J1939/Modbus RTU Slave Gateway

ModbusLink M ModbusLink S. Operations & Maintenance Manual

MODBUS Message Protocol MODEL FT3

MLC 9000 Bus Compatible PID

M-SWITCH SWITCH INPUT IN GAS CONTROL SYSTEM INSTALLATION OPERATION AND MAINTENANCE MANUAL

ABB Drives. User s Manual. Modbus Adapter Module RMBA-01

EA500. Installation Instructions Transponder

Modbus MS Card User manual

Installation and Programming Manual. Niobrara Research & Development Corporation P.O. Box 3418 Joplin, MO USA

USB-COMi-TB USB to Industrial Single RS-422 / 485 Adapter Manual. Specifications and Features

VirtualSCADA VSU-485G USB to RS422/485 Isolated Converter User Manual

Industrial Serial Device Server

Installation and Operating Instructions

Oldham OLCT 200 Revision 1

DATRAN XL4 PLUS RTU Quick Start Guide

MGate MB3000 Modbus Gateway User s Manual

IFC 100 Supplementary instructions

TRAINING GUIDE LEVEL 3 MODBUS WRITE IMPORT COMMAND

AirCare General Purpose ModBus Interface ACM1001. OptiDrive Modbus Module Product Specification. For assistance call

EXD-TEVI Economizer Controller for Tandem Compressors

USB-16COMi-M 16-Port RS-422/485 USB Serial Adapter User Manual. Features and Specifications. Power Supply

isma-b-mg-ip User Manual Global Control 5 Sp. z o.o. Poland, Warsaw

CAS OPW Fuel Management Systems Gateway Modbus (RTU and TCP) and BACnet IP and Web (HTML, REST, JSON, XML, CSV, COSM)

Product Manual SZ2141

High Level Lift Protocol Controller Model TS0868

6-Channel Monitor. Installation and Operation Manual

Model OI x42 ProSafe

Millennium Simplicity Elite Parameter Points and Quirks

Operating Guide MODBUS (RTU) Communications Option IM/L150 MOD_2. Level Indicator L150 and L160

T1K MODBUS Base Controller Specifications

TR600 with RS485 Appendix 1

Technical Bulletin, HT/HM HART Module

RTU560 Connections and Settings DIN Rail RTU 560CIG10

Features: Analog to Digital: 12 bit resolution TTL outputs, RS-232 tolerant inputs 4.096V reference (1mV/count) 115K max speed

ABB Drives. User s Manual Modbus Adapter Module FMBA-01

F-3100 FLOW METER NETWORK INTERFACE Installation and Operation Guide

2 Table of Contents 1. TABLE OF CONTENTS. 1. Table of Contents Introduction Wiring Diagram Terminals Review...

GE Infrastructure Sensing

R1M-GH THERMOCOUPLE & DC INPUT MODULE MODEL. Remote I/O R1M Series. (16 points)

ENVIRORANGER ERS 500 NVIRORANGER ERS 500 COMMUNICATIONS REFERENCE. Instruction Manual August 2001

USER INSTRUCTION MANUAL FOR LOADCELL TRANSMITTER MODEL TDC/I/0550 (SOFTWARE: VER2A) INDEX

Wiring Guide EP.HIO. Version 1.03 Last Updated:

Features. Target Applications. V1.6 TBS07 RS485 to SDI-12 Converter

It is the installer's responsibility to follow all instructions in this manual and to follow correct electrical practice.

User Guide IM/C250 MOD_3. Modbus (RTU) Communications Option C250 and V250

USER GUIDE TEx LU / TEx-M

Model 305e OEM CO 2 concentration sensor

ENG-7680: SCADA Laboratory Experiments

Transcription:

- Modbus Communications Board (RS-485) User Manual Document No. 360-0099-01 (Revision G) Sensidyne, LP. 1000 112 th Circle N, Suite 100 St. Petersburg, Florida 33716 USA 800-451-9444 +1 727-530-3602 +1 727-539-0550 [fax] web: www.sensidyne.com e-mail: info@sensidyne.com

Field Installation Kit If you have ordered the field install kit p/n 821-0221-02, you will need to install the MODBUS Card into your SensAlert Plus transmitter as follows (If not skip to Set Up): 1. Disconnect Power. Dummy Card Dummy Card GP HD and XP 2. Open or Unscrew cover (Note: On the HD and XP Option when doing more than one transmitter, keep cover and transmitter Body as a matched set) 3. Gently unplug the Display Assembly and place it face down on a clean static free work surface. HD and XP SHOWN 4. Unscrew the Banana Plugs and remove the dummy Card. Retain all hardware. 5. Place the MODBUS Card on the Hex Stand-offs and gently couple the plug into the jack on the Display Printed Circuit Board Assembly. 6. Install the Banana Plugs into the Hex Stand-offs. Use two 1/4 wrenches to tighten. 7. Proceed with SET UP. 2 Sensidyne Document No. 360-0099-01 (Rev G)

Set Up NOTE SensAlert Plus Modbus Communication Board The Modbus Communications Board is shipped from the factory with jumpers at JP1 and HDR1 installed as shown is figure. Make certain you adjust jumpers for the network being used. The Board is shipped with wires connected to each of the terminal points. These leads are used in the final test of the Board before being shipped from the factory. For your convenience in testing the Board upon delivery, the color code of the wires is given. These wires need to be replaced before the unit is put into service. (See Cable Recommendation section) VIEWING ANGLE ORIENTATION (FOR JUMPER SETTING PROCEDURE ON FOLLOWING PAGE) HDR1 RX TX Sensidyne Document No. 360-0099-01 (Rev G) 3

4 wire connections and termination resistors F E D C B A HDR1 (SEE VIEWING ANGLE ORIENTATION ON PREVIOUS PAGE) SensAlert Plus Test Lead Color Modbus Master HDR1 4 WIRE NO TERMINATION RESISTORS F E D C B A PCB TB8-5 RXD-A Brown TXD-B TB8-4 RXD-B Green TXD-A TB8-3 TXD-A Violet RXD-B TB8-2 TXD-B Gray RXD-A TB8-1 SHLD NOT USED Shield 4 WIRE WITH TERMINATION RESISTORS PCB 2 wire connections and termination resistors F E D C B A HDR1 (SEE VIEWING ANGLE ORIENTATION ON PREVIOUS PAGE) 2 WIRE NO TERMINATION RESISTORS PCB SensAlert Plus Test Lead Color Modbus Master TB8-5 RXD-A Brown B TB8-4 RXD-B Green A F E D C B A TB8-3 TXD-A NOT USED NOT USED HDR1 2 WIRE WITH TERMINATION RESISTORS PCB TB8-2 TXD-B NOT USED NOT USED TB8-1 SHLD NOT USED Shield Shield Terminations JP1 NO TERMINATION JP1 CIRCUIT GROUND JP1 CHASSIS GROUND 4 Sensidyne Document No. 360-0099-01 (Rev G)

Refer to SensAlert Plus User Manual (P/N: 360-0087-02) The following section is reprinted from the SensAlert Plus User Manual. A properly installed Modbus Communication Board will indicate Modbus Comm at step 5.2.5.5. If Hart Comm. Or No Comm Installed appears, an improper Board has been installed in the transmitter. 5.2 Main Menu As shown on the example display to the right, the top level (main) menu allows the selection of several submenus, documented below. Selecting OK brings up the submenus. Main Menu > Calibration Mode Calibration Mode Maintenance Maintenance Mode Mode Data Data Review Review Test On t-on-demand > System Configuration Lost Password 5.2.5 System Configuration The System Configuration menu provides a large number of functions for configuring the operation of the unit. These include conducting a self test, alarm and relay setup, adjusting the 4 ma & 20 ma outputs, setting the date and time, communications setup, adjusting TOD cell functions, setting combustible sensor parameters, and setting a password. System Configuration > > Self Calibration Test Mode Alarm Maintenance Settings Mode 4/20 Data ma Review Adjustment Adjust Test-on-Demand Date/Time Communication Setup TOD System Mode Config Adjustment --more-- 5.2.5.5 Communication Setup This menu provides adjustment for both standard and optional installed communications methods. Options installed will be displayed. Possible options are Hart Comm Modbus Comm Communication > Calibration Mode Setup Maintenance Mode > 4/20mA Data Review Communication Modbus Comm Tes t-on-demand System Config (If no Communications Option is installed Display will read) No Comm Installed Modbus Comm > Calibration Mode Modbus Address Maintenance Mode Baud Rate Data Review Parity Tes t-on-demand Stop Bits System Config Sensidyne Document No. 360-0099-01 (Rev G) 5

5.2.3 Data Review Data review allows the examination of data stored by the unit. Data reviews are available for the Test-On-Demand gas generating cell, the installed sensor, Fault Currents, Active Alarms/Faults, Rly Alm Fault Config., Calibration Info, and Communication Review. Data Review > > TOD Calibration Review Mode Sensor Maintenance Review Mode Fault Data Currents Review Active Alarms/Faults Test-on-Demand Rly Alm Fault Config Calibration System Config Info Communication Review 5.2.3.7 Communication Review The Communication Review screen displays the present setting Of the 4/20mA Current Loop (SensAlert sensor ID or None). Depending on which Communications Option is installed (None, HART, or Modbus) the display will vary. Communications Review > Calibration Mode 4/20mA Maintenance Communications Mode SensAlert Data Review Sensor ID Modbus Test-on-Demand Comm Add 013 Baud 38400 System Config Parity Even Stop 1 5.1 Menu Map 5.5. Communication Setup 5.5.1. 4-20ma Communications 5.5.1.1. None 5.5.1.2. SensAlert Sensor ID 5.5.2. Hart Comm or Modbus or No Comm Installed 5.5.2.1. Hart Comm 5.5.2.1.1. No User Adjustments Through this Interface Use Current Loop 5.5.2.2. Modbus Comm 5.5.2.2.1. Modbus Address 5.5.2.2.2. Baud Rate 5.5.2.2.3. Parity 5.5.2.2.4. Stop bits 5.5.2.3. No Comm Installed 5.5.2.3.1. -No Communications Board Installed 6 Sensidyne Document No. 360-0099-01 (Rev G)

Modbus Specifications RTU Transmission Mode Byte-order: most-significant-first Functions 01 (0x01) Read Coils 02 (0x02) Read Discrete Inputs 03 (0x03) Read Holding Registers 04 (0x04) Read Input Registers 05 (0x05) Write Single Coil 06 (0x06) Write Single Register 16 (0x10) Write Multiple Registers Modbus RS485 Electrical Specifications RS485 Termination Resisitors RS485 Load 2 wire or 4 wire 120 Ωohms 2 wire ½ Load 4 wire ¼ Load Comm Port Specifications Baud Rate 9600, 19200, 38400 Parity None, Even, Odd Start Bit 1 Data Bits 8 Stop Bit 1 for Parity, 1 or 2 for No Parity Indicators RX LED TX LED Indicates received communications Indicates transmitted communications Cable Recommendations 20-24 AWG Twisted Pair, Overall Shielded 2 wire Single Pair 4 wire Two Pair Belden 9501, 9502, 8451, 8761, 1419A Alpha Wire 5471C, 5472C Sensidyne Document No. 360-0099-01 (Rev G) 7

Modbus Register Addresses This section provides information about the implementation of the Modbus Protocol on the Sensidyne SensAlert Plus Transmitter. The following Modbus Register Addresses have been implemented in the SensAlert Plus device. Coils 00001 Start Zeroing Sensor 00004 Start Sensor Calibration 00007 Start Automatic TOD Test 00010 Stop Sensor Calibration 00017 Clear Latched Relays 00021 Enable Alarm 1 00022 Enable Alarm 2 00023 Enable Alarm 3 00024 Enable Alarm 4 00025 Relay 1 Latch Enable 00026 Relay 2 Latch Enable 00027 Relay 3 Latch Enable 00028 Relay 4 Latch Enable 00032 TOD Fail Enable 00041 Head Fail Fault Enable 00042 Sensor Missing Fault Enable 00043 Sensor Fail Fault Enable 00044 Sensor End of Life Fault Enable 00045 TOD End of Life Enable 00046 Loop Current Out of Tolerance Fault Enable 00047 Calibration Mode Fault Enable 00048 Maintenance Mode Fault Enable 10001 Zeroing Sensor Started 10002 Zeroing Sensor Good 10003 Zeroing Sensor Failed 10004 Calibration of Sensor Started 10005 Calibration of Sensor Good 10006 Calibration of Sensor Failed 10007 TOD Test Started 10008 TOD Test Good 10009 TOD Test Failed 10017 Alarm 1 Active 10018 Alarm 2 Active 10019 Alarm 3 Active 10020 Alarm 4 Active 10031 TOD Test Fail Active 10033 Missing Sensor Active 10034 Head Fail Active 10035 Sensor Fail Active 10036 Sensor End of Life Active 10037 TOD End of Life Active 10038 Loop Current Out of Tolerance 10039 Calibration Mode Fault Active 10040 Maintenance Mode Fault Active Discrete Inputs 8 Sensidyne Document No. 360-0099-01 (Rev G)

Modbus Register Addresses Input Registers 30031 Float Gas Concentration 30033 Float Full Scale Value 30035 Float Loop Current 30037 Float TWA Gas Concentration 30039 Float Sensor Temperature Degrees C 30041 Float Max Gas Concentration 30043 Float Date/Time of Max Gas Concentration 30095 Long Date/Time of Last Calibration 30097 Float Last Calibration Gas Concentration 30099 Float Minimum Sensor Temperature 30101 Long Date/Time of Minimum Sensor Temperature 30103 Float Maximum Sensor Temperature 30105 Long Date/Time of Maximum Sensor Temperature 30111 Float Calibration Pre Exposure Gas Concentration 30159 Int 8 bits Sensor Type High 8 bits Sensor Type Low 30160 Int Display Units 30161 Int 8 bits Display Version High 8 bits Display Version Low 30162 Int 8 bits Comm Board High 8 bits Comm Board Low 30163 Int 8 bits Head Version High 8 bits Head Version Low 30164 Int 8bits Sensor Version High 8 bits Sensor Version Low 30175 Float Minimum Span Value 30177 Float Maximum Span Value 30179 Float Peak TOD Test Value 30181 Long Date/Time of Last TOD Test 30183 Int 12 Bit Representation of Current Loop, 4mA is a count of 800, 20mA is a count of 4000 Date/Time values are seconds from 12:00:00 AM March 1, 2000 40127 Float Alarm 1 Setpoint 40129 Float Alarm 2 Setpoint 40131 Float Alarm 3 Setpoint 40133 Float Alarm 4 Setpoint Holding Registers For further information about the Modbus protocol contact the Modbus-IDA at www.modbus.org Modbus-IDA Headquarters: 37 Wheeler Rd North Grafton, MA 01536 Mailing Address: PO Box 628 Hopkinton, MA 01748 Telephone: +1 508-435-7170 Fax: +1 508-435-6929 e-mail: info@modbus-ida.org Sensidyne Document No. 360-0099-01 (Rev G) 9

Sensidyne, LP. 1000 112 th Circle N, Suite 100 St. Petersburg, Florida 33716 USA 800-451-9444 +1 727-530-3602 +1 727-539-0550 [fax] web: www.sensidyne.com e-mail: info@sensidyne.com