Gmux Modular TDMoIP Gateway FEATURES

Similar documents
Gmux-2000 Hub-Site Pseudowire and Voice Trunking Gateway

Optimux-34, Optimux-25

Optimux-34 Fiber Optic Multiplexer

Megaplex-2100/2104. Data Sheet. Modular Integrated Access Multiplexers

FCD-155. STM-1/OC-3 Terminal Multiplexer FEATURES

ETX-102 Carrier Ethernet Demarcation Device

Kilomux-2100/2104. Data, Voice, Fax and LAN Integrating Modular Multiplexer

Optimux-4T1 Four-Channel T1 Multiplexer

Optimux-1553 STM-1/OC-3 Terminal Multiplexer

RICi-E1, RICi-T1 Fast Ethernet over E1/T1 Intelligent Converters

Optimux-1032, Optimux-1025

This provides an easily configurable solution, flexible enough to meet the specific requirements of a broad range of applications.

Optimux-1553 E3/T3 STM-1/OC-3 Terminal Multiplexer

Optimux-108, Optimux-106

FOMi-40 Fiber Optic Modem with Remote Management

MARKET SEGMENTS AND APPLICATION

IPmux-16 TDM Pseudowire Access Gateway

Kilomux-2100/2104. Data, Voice, Fax and LAN Integrating Modular Multiplexer FEATURES

Optimux-108, Optimux-106 Four-Channel E1/T1 and Ethernet Multiplexers

ASMi-52 2/4-wire SHDSL Modem/Multiplexer

IPmux-11. TDMoIP Gateway DESCRIPTION FEATURES

2/4-wire SHDSL Modem/Multiplexer

Where to buy > Product page >

Kilomux-2100/2104. Data, Voice, Fax and LAN Integrating Modular Multiplexer FEATURES

FCD-155 STM-1/OC-3 Terminal Multiplexer

IPmux-1E TDM Pseudowire Access Gateway

ACE-2002, ACE-2002E. Multiservice Access Concentrators/ ATM Network Termination Units FEATURES

ASMi-52. 2/4-Wire SHDSL Modem FEATURES

FCD-E1E Managed E1 and Fractional E1 Access Device

Optimux-108, Optimux-106

DXC /1/0 modular multiservice cross connect access node up to 1.2 Gbps matrix. Data Sheet. Multiservice Access Node. The Access Company

ASMi-54 SHDSL.bis Modem

ASMi-54L. Data Sheet. SHDSL.bis Modem

FCD-155. STM-1/OC-3 Terminal Multiplexer DESCRIPTION FEATURES

ATM OVER PACKET CAPABILITIES

ASMi-54 SHDSL.bis Modem

Vmux-2120 Voice Trunking Gateway

Kilomux Accessories KM-Ringer, Ringer-2000, Ringer-2200N DC Feed and Ring Power Supplies for Voice/Fax and ISDN Modules

FCD-E1, FCD-T1 E1/T1 or Fractional E1/T1 Access Units

Optimux-108, Optimux-106

FCD-155 STM-1/OC-3 Terminal Multiplexer

ASMi-54L SHDSL.bis Modem

FCD-E1LC, FCD-T1LC Managed E1/T1 or Fractional E1/T1 Access Units

SFP Transceivers Small Form-Factor Pluggable Transceivers

FCD-155 STM-1/OC-3 Terminal Multiplexer

ETX-201A Carrier Ethernet Demarcation Device

Airmux-400, Airmux-5000 Optional Accessories

Megaplex-2100/2104 Modular Integrated Access Multiplexers

Modular E1 or Fractional E1 Access Unit. Dial-out for alarm report The E1 main link can be supplied with the following options:

SFP Transceivers Small Form-Factor Pluggable Transceivers

Multiservice Network Termination Unit

LRS-12. "Last Mile" SNMP Modem Rack FEATURES

Vmux-400 GSM A-bis/A-ter Optimization Gateway

FCD-155E STM-1/OC-3 Add/Drop Multiplexer

Vmux-210 Analog Voice Trunking Gateway

E1/T1 or Fractional E1/T1 Modular Access Device with Integrated Router

IPmux-1E. TDMoIP Gateway FEATURES

ETX-203AX Carrier Ethernet Demarcation Device

FCD-155E STM-1/OC-3 Add-Drop Multiplexer

ACE-3000 Family ACE-3400 Aggregation Site Gateway

MARKET SEGMENTS AND TYPICAL

IPmux-4LGE TDM Pseudowire Gateway

IPmux-14. TDMoIP Gateway FEATURES DESCRIPTION

Kilomux-2100/2104 KVF.6 E1/T1 Voice Compression Module

IPmux-14. TDM Pseudowire Access Gateway FEATURES

ACE-3000 Family ACE-3100 Cell-Site Gateway

Where to buy > Product page > (E1/T1, SHDSL, data or voice ports) into IP or MPLS packets for transmission over Ethernet, IP or MPLS networks.

ETX-204A Carrier Ethernet Demarcation Device

RICi-16 Ethernet over Bonded PDH Network Termination Unit

Megaplex-4100 Next Generation Multiservice Access Node

Datasheet. Multi-Service Access Platform OPCOM3500E-12. OPCOM3500E-12 Feature. Raisecom Technology Co., Ltd.

ACE-202/2002/2002E ATM STM-1, STM-4, IMA and ATM UNI Modules

ACE-3000 Family ACE-3200 Cell-Site Gateway

RICi-16 Ethernet over Bonded PDH Network Termination Unit

LA-140. Advanced ATM IAD FEATURES

modules in the MP-4100/4104 chassis (E1/T1, SHDSL, data or voice ports) into IP or MPLS packets for transmission over Ethernet, IP or MPLS networks.

ETX-204A Carrier Ethernet Demarcation Device

Kilomux-2100/2104 KVF.8 8-Channel Analog Voice Compression Module

IPmux-24 TDM Pseudowire Access Gateway

Vmux-110 Voice Trunking Gateway for Remote Sites

SFP/XFP Transceivers Small Form-Factor Pluggable Transceivers

Megaplex-4100 Next Generation Multiservice Access Node

Note: IPmux-155L equipped with the AC or 48 power supply modules supports up to 16 MiRICi-E3T3 units.

Where to buy > Product page >

OPERATION MANUAL INSTALLATION AND MPW-1. TDM Pseudowire Access Gateway. MP-4100 Version 2.0. The Access Company

VB-8030/8034. Hybrid Ethernet/TDM Central Aggregation Solution Platform for Seamless and Economical Migration to Next-Generation Communication

E1/T1 or Fractional E1/T1 Access Unit with Integrated Router

BROAD RANGE OF INTERFACES

ACE-3000 Family ACE-3105 Cell-Site Gateway. 2G, 3G and HSDPA cellular traffic over packet-switched networks (PSNs) and ATM, using DSL uplinks

Vmux-110. Voice Trunking Gateway FEATURES

Prisma II Platform. Optoelectronics

Cisco Prisma II Platform

Product page > Link-layer OAM according to IEEE 802.3ah is used for fault indication and loopback activation response.

SFP/XFP/SFP+ Transceivers

HS-2. MEGAPLEX-2000/2100 Module. 2-Channel High Speed Data Module DESCRIPTION FEATURES

FMUX1001 Modularized 16E1/T1 + 4x GbE Managed Fiber Multiplexer FMUX101 Modularized 16E1/T1 + 4x FE Managed Fiber Multiplexer

Megaplex-2100/2104. Modular Integrated Access Multiplexers

IPmux-2L, IPmux-4L. IPmux-2L, IPmux-4L are a TDM pseudowire. also serves as an Ethernet-based access device.

ETX-203A Carrier Ethernet Demarcation Device

VCL-TP, Teleprotection Equipment

Transcription:

FEATURES Carrier-class modular TDMoIP gateway, extending high capacity TDM traffic over packet-switched networks (PSNs) Operates opposite other members of RAD s TDMoIP family of products, offering a complete cost-effective TDMoIP solution Handles up to 63 E1 or 84 T1 streams to fully populate a channelized STM-1 or OC-3 trunk Handles up to 196 E1 or T1 streams transported via seven 28-port external E1/T1 interface modules Packet-switched network interface via a dual-port Gigabit Ethernet module SDH and SONET interface via dual-port STM-1 and OC-3 module with link protection Full redundancy of the STM-1/OC-3 links, clocks, control and power supply modules Management via ASCII terminal, Telnet host, Web terminal or SNMP-based network management station Provisioning and monitoring of TDMoIP services using the RADview Service Center for TDMoIP applications Non-volatile flash memory for software upgrade and configuration download AC and DC power supplies 6U chassis suitable for ETSI or ANSI installations

DESCRIPTION Gmux-2000 is a modular TDMoIP gateway that extends the TDM traffic (originating from legacy circuit-switched networks) over packet-switched networks (PSNs). This is achieved by converting TDM data streams coming from the TDM ports into IP packets transported over the PSN. Gmux-2000 features the following ports: TDM ports: SDH/SONET port at the STM-1/OC-3 level (155.52 Mbps), or external PDH ports at the E1/T1 level PSN port: GbE optical interface via SFP modules. The Gmux-2000 capacity is 63 E1 streams (full STM-1 payload) for the SDH version, and 84 T1 (full OC-3 payload) streams for the SONET version. The E1 streams are transparently transported using a circuit emulation method, while supporting all the signaling protocols and payload types. Advanced packet handling capabilities, VLAN and ToS support ensure the highest quality of service (QoS) that modern packet-switched networks can provide. APPLICATIONS Gmux-2000 is designed as a central site solution for RAD s TDMoIP products, operating opposite all members of the IPmux product line and Megaplex ML-IP. CHASSIS The modular chassis of Gmux-2000 can accommodate up to seven I/O modules, two Gigabit Ethernet trunk modules, two SDH/SONET modules, two control/clock modules, three power supply modules (AC or DC), one power inlet module (AC or DC) and a fan unit. The modules are hot-swappable. Gmux-2000 comes in a 6U-high chassis, mountable in a 19-inch ETSI or ANSI rack. PSN INTERFACE MODULE The Gigabit Ethernet module serves for packet network connection to the PSN. The module is equipped with a pair of redundant replaceable SFP-based fiber optic GbE interfaces. Operating as a Level-3/4 switch, the Gigabit Ethernet module routes the packets coming from the packet network to the I/O modules and the system modules connected to the packet bus. The routing is performed at wire speed, minimizing delays on the packet bus. The GbE interface operation complies with the IEEE 802.3, 802.1Q and 802.1p requirements. SDH/SONET INTERFACE MODULE Gmux-2000 uses STM-1/OC-3 modules for the SDH/SONET connection. Each STM-1/OC-3 module has two ports that can be ordered with electrical (75Ω coax), or optical interfaces with various characteristics (850 nm or 1310 nm with laser and LED transmitters). The module complies with the applicable requirements of ITU-T Rec. G.957, G.958, I.432 and G.703. The STM-1/OC-3 module operates as a terminal multiplexer and is usually connected to an STM-1/OC-3 add/drop multiplexer port for access to the SDH/SONET backbone. The STM-1/OC-3 module provides 1+1 line redundancy to ensure rapid restoration of service in case of line failure. Figure 1. Extending Multiple TDM Trunks over a Packet-Switched Network

TDMoIP CIRCUIT EMULATION MODULES Gmux-2000 uses the following TDMoIP Circuit Emulation (CE) modules, in accordance with the required external TDM interface: When external E1/T1 interfaces are required, 28-port external E1/T1 modules are used When STM-1 or OC-3 interface to SDH/SONET is required, dedicated TDMoIP server modules are used to bridge between the PSN interface module and the STM-1/OC-3 interface module. CONTROL MODULES The control modules interface with the external SNMP-based network management stations, supervision terminals, Telnet hosts and Web browsers. Each control module has two out-of-band ports: a serial RS-232 synchronous port and a 10/100BaseT Ethernet port. The control modules store the application software in flash memory. This software can be remotely updated through the management link. The control modules collect the operational history (alarms, configuration error messages, performance statistics, etc). The Gmux-2000 chassis uses two control modules, providing hot-standby system control. MANAGEMENT CAPABILITIES The chassis can be managed using different ports and applications: Local out-of-band management via an ASCII terminal connected to the RS-232 port Remote out-of-band management via the dedicated 10/100BaseT port Remote inband management via the GbE interface. Remote management is performed using Telnet, Web browser or RADview-SC/TDMoIP, RAD s SNMP-based network management system. ALARM REPORTING The chassis features a dry-contact connector for reporting alarms to external equipment. The connector also has an external alarm input for monitoring external sensors. Gmux-2000 TIMING Gmux-2000 includes a central timing subsystem, located on the control module (two station clock ports per module), and local timing subsystems located on the individual I/O modules. If a control module providing a system clock fails, Gmux-2000 switches to the second control module, without affecting system performance. Gmux-2000 provides a flexible clock management using the timing signals coming from: Station clock source SDH/SONET interface SDH/SONET internal virtual container clock Clock recovered from a TDMoIP flow generated by a remote TDMoIP gateway. Figure 2. Aggregating TDMoIP Links for Transmission over an SDH/SONET Network

SPECIFICATIONS TDM Interfaces Two SDH/SONET ports (155.52 Mbps): STM-1 (63 E1) OC-3 (84 T1) PDH: 196 E1 or T1 PSN Interface Two GbE ports (1.25 Gbps) via SFP modules Routing Capabilities Any E1/T1 stream from any PDH or SDH/SONET interface to any IP destination MANAGEMENT Methods Supervision terminal, directly or via modem link Telnet Web browser RADview-SC/TDMoIP or other SNMP-based NMS Interfaces Serial ports on control modules 10/100BaseT ports on control modules Inband via PSN interface ports Serial Port Type: RS-232 (V.24) async DCE Data rate: 0.3 115.2 kbps Connector: 9-pin, D-type, female EXTERNAL ALARM INTERFACE Alarm Outputs Major alarm indication by floating change-over dry contacts Minor alarm indication by floating change-over contacts Output Contact Ratings Maximum 60 VDC/30 VAC across open contacts Maximum 1 ADC through closed contacts Maximum load switching capacity: 60W External Alarm Input One active-low input, RS-232 levels POWER Source AC: 100 to 240 VAC, 50/60 Hz DC: -48 VDC Power Consumption 200W max Number of PS Modules 3 Number of Power Inlets (via separate power inlet module) AC: 3 DC: 2 Redundancy 2+1 PHYSICAL Number of Slots 1 power inlet slot 3 power supply slots 2 control slots 9 I/O slots 1 cooling fan tray slot Dimensions Height: 265 mm (10.4 in) Width: 440 mm (17.3 in) Depth: 210 mm (8.2 in) Weight 12 kg (26.4 lb), max Environment Operating temperature: 0 to 55 C (0 to 131 F) Storage temperature: -20 to +70 C (0 to 150 F) Humidity: Up to 90%, non-condensing

ORDERING Standard Gmux-2000 systems are comprised of a chassis, service modules (control, power supply, etc), and interface modules (GbE, STM-1, OC-3, E1, T1 and servers). Figure 3 illustrates minimal required combinations of the service and interface modules in the chassis. See separate module data sheets for interface module details and ordering information. GMUX-2000-SYS/* Gmux-2000 chassis * Specify rack type: A for ANSI rack E for ETSI rack GMUX-M/@/# Gmux-2000 service module @ Specify service module type: PI for power inlet module PS for power supply module CL for control and timing module FANS for fan unit module # Specify power inlet and power supply module type: AC for AC power inlet module and 100 240 VAC power supply module DC for DC power inlet module and -48 VDC power supply module SUPPLIED ACCESSORIES RM-2000 Hardware kit for mounting one Gmux-2000 chassis into a 19-inch rack RM-2000E Hardware kit for mounting one Gmux-2000 chassis into an ETSI rack 1 Power Inlet Module 2 or 3 Power Supply Modules 1 or 2 Control Modules 1 Power Inlet Module 2 or 3 Power Supply Modules 1 or 2 Control Modules 1 GbE Module 1 STM1 or OC3 Module 1 3 Circuit Emulation E1/T1 Modules (E1-CE-SRV/21 or T1-CE-SRV/28) Channelized STM-1/OC-3 Service 1 GbE Module 1 7 Circuit Emulation E1/T1 Modules (E1-CE/28 or T1-CE/28) N E1/T1 Service Fan Unit Fan Unit Figure 3. Minimal Required Module Combinations in the Gmux-2000 Chassis www.rad.com International Headquarters 24 Raoul Wallenberg Street Tel Aviv 69719, Israel Tel: 972-3-6458181 Fax: 972-3-6498250 Email: market@rad.com North America Headquarters 900 Corporate Drive Mahwah, NJ 07430, USA Tel: (201) 529-1100 Toll free: 1-800 444-7234 Fax: (201) 529-5777 Email: market@radusa.com 358-100-03/06 2006 RAD Data Communications Ltd. Specifications are subject to change without prior notice. The RAD name, logo, logotype, and the term TDMoIP Driven are registered trademarks of RAD Data Communications Ltd. All other trademarks are the property of their respective holders.