OPERATIONS MANUAL ACL 350 DIGITAL STATIC LOCATOR

Similar documents
ACL 350 Digital Static Locator

ELECTROSTATIC FIELDMETER

Electrostatic Fieldmeter Model 775

CHARGED PLATE ANALYZER CHARGED PLATE ANALYZER KIT

MulTI-Touch Projected Capacitive Touch Screen Integration Guide

Electrostatic Field Meter EFM 022

MANUAL. Electrostatic Field Meter EFM 022. System Prof. Dr.-Ing. Hans Kleinwächter

OLS Series Light Sources, OPM Series Optical Power Meters, and Related Test Kits User s Guide

TEST AND MEASUREMENT SRM 200 SRM 200/EFM 51 STARTERKIT

STATIC METERS Models 211 & 212. SURVEYORSTAT Models 211XL & 212XL

INTRODUCTION CT87E FEATURES AND CONTROLS

OPERATING INSTRUCTION

TITLE PAGE I. Safety Information II. General Description III. Specifications IV. Controls V. Calibration Procedures VI. Measurement Preparation

User's Guide. Digital Multimeter. Model MN42

W Warning To avoid electrical shock, remove test leads and any input signals from the Model 707 Loop Calibrator before opening the case.

Manual No Revision MODEL GLI-9835 HAND-HELD/PORTABLE CONDUCTIVITY/TDS METER

Autoranging True RMS Multimeter User Manual

Mini Digital Multimeter

ELECTROSTATIC FIELDMETER

INSTRUCTION MANUAL. Model True RMS AC/DC 30A Mini Clamp-on Meter. Introduction. True RMS AC Current and Voltage

MARTINDALE INSTRUCTIONS MM35 DIGITAL MULTIMETER ELECTRIC. Trusted by professionals

QUICK REFERENCE. Getting Started

Mini Digital Multimeter

Mini Digital Multimeter

This 4200-RM Rack Mount Kit is for installation in 4200-CAB series cabinets only.

Pro II. Sound Level Meter V-9992

S-14 S-14. Compact Digital Multimeter. Compact Digital Multimeter

SoniChek MC. 99 Washington Street Melrose, MA Phone Toll Free TRIPLETT. Mini Sound Level Meter C Weighted

SOUND LEVEL METER DVM1351 INSTRUCTION MANUAL HANDLEIDING MANUEL D UTILISATEUR DVM1351 SOUND LEVEL METER 1

INSTRUCTION MANUAL. Sound Calibrator NC Higashimotomachi, Kokubunji, Tokyo , Japan

EDGE. Digital Kitchen Scale. 11lb x 0.1oz 5000g x 1g

1. Review the printer safety information in the Regulatory Compliance document provided with your printer.

DIGITAL VOLTAGE INDICATOR

2 in 1 LAN Tester and Multimeter Model:

3 Maintenance. Chapter contents

DM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER

CSS1 Contractor Series Light Sources and CSM1 Contractor Series Optical Power Meters User s Guide

User s Guide. 600A True RMS AC/DC Clamp Meter. Model 38389

Owner's Manual. True RMS Multimeter. Model No Safety Operation Maintenance Español

Model R8050. Instruction Manual. Sound Level Meter. reedinstruments. REED Instruments

User s Manual. Digital Baby Scales. Hopkins Featherweight Baby Scale # Hopkins Featherweight XL Baby Scale # # #688340

CM-140. Instruction Manual SOUND LEVEL METER G A L A X Y A U D I O

Advanced Instrument Development, Inc Curtiss St. Downers Grove, IL U.S.A. Phone: (630) Fax: (630)

Allen-Bradley Drives. Instructions. (For 6180 Industrial Computers)

User Guide True RMS Multimeter Extech EX205T

User's Guide. ExStik EC400. Conductivity / TDS / Salinity / Temperature Meter MODE HOLD

HV-CS kv Edge Mount Triaxial Jack

FMX-004. User Manual. Call the experts on us

Installation Job Aid for Ethernet Routing Switch 3600 Series

User's Guide. Phase Sequence and Motor Rotation Tester Model

Keysight M8000 Series BER Test Solutions

CHAPTER 2: USING MANAGER PREFERENCE. 2.1 Using Manager Mode Using CSAFE Console (back side) Access Layout...

User Guide. ExStik FL700. Fluoride Meter

User's Guide. MiniTec TM Series Model MN25 MultiMeter

HS-27 Manual 5/2/2013. Neuralynx, Inc. 105 Commercial Drive, Bozeman, MT Phone Fax

Installation Job Aid for Ethernet Routing Switch 5900 Series

INSPECTION CAMERA MODEL NO: CIC2410 OPERATION & SAFETY INSTRUCTIONS PART NO: GC0116

Analog Resistive Touchscreen QST Series Product Specifications

700 Series 200 Amp Clamp Meters

UWE-1707 SERIES CONTENTS OPERATION MANUAL ELECTRONIC WEIGHING INDICATOR 1. SPECIFICATIONS 2. INSTALLATION

OPERATING INSTRUCTIONS

User s Guide. 600A AC Clamp Meter. Model 38387

User Guide. ExStik II EC400. Conductivity / TDS / Salinity / Temperature Meter

-auto Power Off- T1/T2/T1-T2

Model: Pro93 TRUE RMS LEAKAGE CURRENT TESTER

TOP - 1. Instruction Manual. Version 1.0 Produced in Jan. 2004

3M Static Sensor 718, 3M Air Ionizer Test Kit 718A. User s Guide

P1 PowerStation Backlight Bulb

IDEAL INDUSTRIES INC. TECHNICAL MANUAL MODEL:

User's Guide. Extech AM A AC Analog Clamp Meter

Keysight E5864A Removable Hard Drive for Series Logic Analyzers. Installation Guide

Model INSTRUCTION MANUAL DIGITAL MULTIMETER

User s Manual. Sound Level Meter. FSM 30Plus. Lo/Hi MAX HOLD S/F. S F db BAT. SOUND LEVEL: Lo=35~100dB Hi=65~130dB. 94dB

Mini Digital Multimeter Model MN15. User's Guide

200B-G Tone Probe. 200EP-G Tone Probe INSTRUCTION MANUAL. with Adjustable Volume

ph, ORP, and TDS ORP Continuous Monitor OPERATING INSTRUCTIONS 8. Warranty 9. Return of Goods

DVD/CD RECEIVER SERVICE MANUAL

Table of Contents Product Overview Before using the product Installation Procedure... 5

V /06/ Velleman nv

SOLAR POWER METER TM-206. User s Manual HB1TM

Model R5010. TRMS Digital Multimeter. Instruction Manual

PS/IO Circuit Board Retrofit

R5050. Model. Instruction Manual. TRMS AC/DC Clamp Meter. reedinstruments. www. com

Charge Analyzer 711. Operating Instructions. August

VELOCICALC Air Velocity Meter

Polarization Microscope. Omano OM349P Series. User Guide

OPERATION MANUAL SERIES MICRO BORESCOPES INSTRUMENT TECHNOLOGY, INC. POB 381, Westfield, MA Airport Road, Westfield, MA 01085

711 Charge Analyzer Operation and Maintenance

Installation Instructions

LSL250. Laser light! Do not stare into the beam or view directly with magnifiers. Class 2 laser EN :

High Precision Quad Output DC Power Supply

INSTRUCTION MANUAL TRIP CIRCUIT SUPERVISION RELAY GKAD1

I/R Thermometer Gun 8:1

Voltage Detector and Phasing Tester Operating Instructions 83280

ETHOS Auto Ranging Digital Multimeter

Torque Series LCD Remote Panel Installation/Operation Manual Model: TQ-DSP-12/24

HS-27-Mini. Headstage preamplifier providing 27 channels of unity gain amplification.

AutoRanging Digital MultiMeter

VTPC190V / VS / VDC / VSDC

Prestigio P371 Users manual

Transcription:

OPERATIONS MANUAL ACL 350 DIGITAL STATIC LOCATOR

ACL 350 DIGITAL STATIC LOCATOR OPERATIONS MANUAL TABLE OF CONTENTS Title Page No. BEFORE USING THE INSTRUMENT... ACL 350 Page 2 SAFETY... ACL 350 Page 2 FUNCTION... ACL 350 Page 2 ACCURACY... ACL 350 Page 2 BATTERY INSTALLATION & MAINTENANCE... ACL 350 Page 3 Battery Replacement... ACL 350 Page 3 Cleaning... ACL 350 Page 3 STANDARD OPERATION... ACL 350 Page 4 BASIC OPERATION WHILE USING THE ONE INCH SPACER... ACL 350 Page 5 OPERATION WHILE USING THE ONE INCH SPACER AS DIST. REF. ACL 350 Page 6 ACL 350 DIGITAL STATIC LOCATOR SPECIFICATIONS... ACL 350 Page 8 ACL 350 DIGITAL STATIC LOCATOR DISTANCE CHART... ACL 350 Page 9 Rev. 01/29/10 MKB ACL 350 Page 1 of 9

ACL 350 DIGITAL STATIC LOCATOR Before using this, or any other electronic piece of equipment, carefully read the instruction manual completely. I. BEFORE USING THE INSTRUMENT Examine the instrument for damage, contamination (excessive dirt, grease, etc.) and defects. If any abnormal conditions exist, do not attempt to make any measurements. II. SAFETY A. The following safety information must be observed to insure maximum personal safety during the operation of this meter. 1. DO NOT use the meter if the meter looks damaged, or if you suspect that the meter is not operating properly. 2. DO NOT touch the front sensing head while operating this meter. 3. Measuring voltage which exceeds the limits of this meter may damage the meter and expose the operator to a shock hazard. Always recognize the meter voltage limits as stated. III. FUNCTION The ACL 350 Static Locator is a non-contact meter that indicates electrostatic field voltage and polarity on charged surfaces. This easy to use instrument comes equipped with a Power On/Hold button, a zero button and a unique retractable one inch spacer. The meter automatically shuts off after approximately 90 seconds. The unit's grounding path is through its conductive case, so there is often no need to wear a grounded wrist strap during normal operations. The easy to read 3-1/2 digit LCD display automatically updates three times per second. Measurements are dependent on the distance from the object being measured. IV. ACCURACY A. The accuracy of the ACL 350 is dependent upon three factors. 1. The instrument must be properly grounded and zeroed. 2. The distance from the front edge of the case to the target or surface under examination must be accurate and stable. Rev. 01/29/10 MKB ACL 350 Page 2 of 9

3. The target must be large relative to the measurement distance. The target should be at least 5" x 5" for true accuracy at 1". V. BATTERY INSTALLATION & MAINTENANCE A. Battery Replacement B. Cleaning 1. Power is supplied by a standard 9 volt "transistor" battery. 2. Replace the battery when the "BAT" indicator appears in the display above the "HOLD indicator for more than an instant or at least once a year. NOTE: Dead battery voltage is approximately 7.2 volts. 3. Unit should be OFF when replacing battery. 4. To replace the battery, remove the cover from the back of the meter. 5. Remove the battery from its compartment, and disconnect it from the power terminals. 6. Connect a new battery to the power terminals and install it in the battery compartment. 7. Replace the battery cover by mounting it carefully in the grooves provided, then sliding it closed until it "clicks" shut. Do not over force the cover on. If the cover does not shut easily, remove the battery and reinsert for a better fit. Be sure wires do not hamper closing the battery cover. 8. The meter is now ready for use. 1. If excessive drift is noted, the surface of the sensing electrode may require cleaning. a. Wipe the electrode surface with a soft, low linting cloth dampened with alcohol. b. Allow to dry thoroughly before use. 2. Remove dust or dirt from case or display using a soft, low linting cloth. Rev. 01/29/10 MKB ACL 350 Page 3 of 9

VI. STANDARD OPERATION A. While holding the ACL 350 in one hand, discharge your body by touching a grounded conductive object. 1. The operator may wear a grounded wrist strap or place a grounded wrist strap cuff around the instrument case beneath the display and operating buttons. 2. The case of the instrument is conductive and is the reference for measurement. B. Press the POWER ON/HOLD button and release C. Face the static locator away from charged objects and depress and release the ZERO button twice. Note that the display indicates 00.0 volts. Due to the tolerance and sensitivity of the sensor, the value may drift by.1 or.2. The sensor can pick up noise from fluorescent lights, electronics, and air movement. D. Point the sensor plate toward the target and move to a point one inch from the surface to be measured. Thus, there should be a one inch space between the front sensing end of the case and the target. 1. Note the meter reading. 2. To hold the reading, press and hold the PWR ON/HOLD button. 3. A source with a negative polarity will show a minus (-) sign in the display. 4. A positive source will display no sign. NOTE: If, as you approach the target, the indicated field strength begins to exceed 20kV at a distance greater than 1", STOP! This implies that the target voltage may be high enough to create an arc. Proceed with caution. E. Repeat the procedure outlined above for additional measurements. F. The instrument will automatically shut off after approximately 90 seconds from the time the PWR ON/HOLD button was last activated. Rev. 01/29/10 MKB ACL 350 Page 4 of 9

VII. BASIC OPERATION WHILE USING THE ONE (1) INCH RETRACTABLE SPACER The retractable spacer is provided to conveniently define the measurement space between the front sensing end of the instrument case and the measurement target. The spacer is made of a low charge generating, somewhat insulative material. It is designed to avoid discharging the measurement target surface if touched by the spacer, and minimize influence of the electrostatic field measurement. A. While holding the ACL 350 in one hand, discharge your body by touching a grounded conductive object. 1. The operator may wear a grounded wrist strap or place a grounded wrist strap cuff around the instrument case beneath the display and operating buttons. 2. The case of the instrument is conductive and is the reference for measurement. B. Press the POWER ON/HOLD button and release. C. Face the static locator away from charged objects and depress and release the ZERO button twice. Note that the display indicates 00.0 volts. D. Rotate the one inch spacer 180 o from its storage configuration such that it extends beyond the front sensing end of the case, and is on a parallel plane with the case. E. If the display indicates a measurement other than 00.0, repeat the ZERO procedure above. This will compensate for any small charge on the spacer. F. Point the sensor plate toward the target and move to a point one inch from the surface to be measured such that the spacer is virtually in contact with the target material. At this point, there is a one inch space between the front sensing end of the case and the target. Rev. 01/29/10 MKB ACL 350 Page 5 of 9

1. Note the meter reading. 2. To hold the reading, press and hold the PWR ON/HOLD button. 3. A source with a negative polarity will show a minus (-) sign in the display. 4. A positive source will display no sign. NOTE: If, as you approach the target, the indicated field strength begins to exceed 20kV at a distance greater than 1", STOP! This implies that the target voltage may be high enough to create an arc. Proceed with caution. G. Repeat the procedure outlined above for additional measurements. H. The instrument will automatically shut off after approximately 90 seconds from the time the PWR ON/HOLD button was last activated. I. To retract the spacer, rotate it 180 until it rests parallel to the case with its point toward the battery compartment. VIII. OPERATION WHILE USING THE ONE-INCH SPACER AS A DISTANCE REFERENCE In some cases, you may wish to use the spacer to estimate the one-inch distance from a measurement target surface, but make the measurement without the presence of the spacer to minimize its influence on measurement accuracy. A. While holding the ACL 350 in one hand, discharge your body by touching a grounded conductive object. 1. The operator may wear a grounded wrist strap or place a grounded wrist strap cuff around the instrument case beneath the display and operating buttons. 2. The case of the instrument is conductive and is the reference for measurement. B. Press the POWER ON/HOLD button and release C. Face the static locator away from charged objects and depress and release the ZERO button twice. Note that the display indicates 00.0 volts. Rev. 01/29/10 MKB ACL 350 Page 6 of 9

D. Rotate the one-inch spacer 180 o from its storage configuration such that it extends beyond the front sensing end of the case, and is on a parallel plane with the case. If the display changes when the spacer is deployed, do not re-zero the instrument. E. Point the sensor plate toward the target and move to a point one inch from the surface to be measured such that the spacer is virtually in contact with the target material. Carefully retract the spacer without moving the instrument away or towards the measurement target surface. At this point, there is approximately one inch space between the front sensing end of the case and the target. 1. Note the meter reading. 2. To hold the reading, press and hold the PWR ON/HOLD button. 3. A source with a negative polarity will show a minus (-) sign in the display. 4. A positive source will display no sign. NOTE: If, as you approach the target, the indicated field strength begins to exceed 20kV at a distance greater than 1", STOP! This implies that the target voltage may be high enough to create an arc. Proceed with caution. F. Repeat the procedure outlined above for additional measurements. G. The instrument will automatically shut off after approximately 90 seconds from the time the PWR ON/HOLD button was last activated Rev. 01/29/10 MKB ACL 350 Page 7 of 9

ACL 350 DIGITAL STATIC LOCATOR SPECIFICATIONS Readout: Polarity: Zero: Response: Low Battery Indication: Hold indication: mode Spacer: Measurement Ranges: 3-1/2 digit LCD, automatically displays measured voltage. Automatic, positive implied, negative polarity indication Semi-Automatic, "Push to Zero" Feature Display updates three times per second "BAT" is displayed when voltage is too low for proper function The "HOLD" indication appears on the LCD when in hold Retractable 1 Inch spacer @1 inch: 0-20,000 volts in 100 volt increments @1/10 inch: 0-2,000 volts in 10 volt increments Extended Ranges: @ 4 inches: ± 40,000 volts (multiply reading x 2) @ 6.5 inches: ± 60,000 volts (multiply reading x 3) @ 8.5 inches: ± 80,000 volts (multiply reading x 4) Overall Accuracy: Better than ± 10% Grounding Path: Battery SavRTM Timeout: Through conductive case Typically 90 seconds, automatic shut off Power: One (1) standard 9-volt battery, PROCELL, Eveready #216 (NEDA 1604, JIS 006P, IEC 6F22) Eveready #216 Battery Life: Dimensions: Weight: 200 hours typical 4.2 inches x 2.4 inches x.9 inches 5 oz. (142 gm) Rev. 01/29/10 MKB ACL 350 Page 8 of 9

ACL 350 Digital Static Locator Distance Reading multiply Volts 1/10" 0.1 10 v 1 100v 10 1,000v 20 2,000v 1" 0.1 100 v 1 1000v 10 10,000v 20 20,000v 4" 0.1 2 x 100 v 200 v 1 2 x 1000v 2000v 10 2 x 10,000v 20,000v 20 2 x 20,000v 40,000v 6.5" 0.1 3 x 100 v 300 v 1 3 x 1000v 3000v 10 3 x 10,000v 30,000v 20 3 x 20,000v 60,000v 8.5" 0.1 4 x 100 v 400 v 1 4 x 1000v 4000v 10 4 x 10,000v 40,000v 20 4 x 20,000v 80,000v Rev. 01/29/10 MKB ACL 350 Page 9 of 9