Table 8 shows the pin configuration and function of a standard computer-to-printer parallel cable. Table 8 Parallel Cable Pin Configuration

Similar documents
Select a Data Communication Interface

Serial Interfaces Part 1. ECE 153B Sensor & Peripheral Interface Design Winter 2016

Appendix A Cable Pinouts

Sender Receiver Sender

Connector and Cable Specifications

Cable Pinouts. SRP I/O Module

(renamed the "EIA232 Standard" in the early 1990 s)

Wrenchman, Inc Old Hwy. # 8 Suite # 122 New Brighton, Minnesota (651)

RS-232 SERIAL INTERFACE PHOTOELECTRIC ISOLATOR

Serial Communication Prof. James L. Frankel Harvard University. Version of 2:30 PM 6-Oct-2015 Copyright 2015 James L. Frankel. All rights reserved.

User Manual. ASeries A704

IM3523 IM3533 IM IM3536 LCR METER IM3570 IM7580 IM3590 CHEMICAL IMPEDANCE ANALYZER IMPEDANCE ANALYZER. Communication Instruction Manual

Bluetooth to RS-232 Converter. RT-132B Bluetooth Adaptor Operation Manual

solartron digital readout model no. DR600 DR700 installation manual

ZM56 High-Speed Industrial Modem. Command Summary. 1 ZM56 High-Speed Industrial Modem

MS Protocol Converter. User Manual. Firmware version 2.0 ISI. Instrumental Solutions, Inc.

3710 ACM 3750 PDC 3800 RTU. ISOCOM Communications Card Retrofit Instructions

Connector and Cable Specifications

The Analyst. RS422/RS232 Tester. (Standard Model) User Manual

4.3 Digital Communication

GPIO Option Rev.B

AUDIO D-Type Pin-outs TALKBOX INSTALLER 12 1U RACK BOX BCD 25/09/07. Broadcast Audio Custom Manufacture Design and Consultancy

Serial Communication Converters & Adapters Instruction Manual

Cable Specifications. Interface Specifications. Fiber-Optic Specifications APPENDIXB

Storage/Control I/O Module

Serial Link Generic Tank Mode Installation Manual. Pro Fuel Management System. RE Rev C July 00

WiFi to RS-232 adapter user manual

Bluetooth TO Serial CONVERTER E-P132-B

Chapter 11: Input/Output Organisation. Lesson 05: Asynchronous RS232C Serial Port data transfer

Bluetooth to RS-232&RS422/485. EX-9132B/BI Bluetooth Adapter Operation Manual

Sartorius Comparator. Interface Description for the CC Model Series

Cable and Port Specifications

Koppelmodul (HART--Modem) für SIMATIC PDM Interface (HART modem) for SIMATIC PDM

XiIII - Series Maintenance Manual

USER S MANUAL. PH232Ex1. #1 RS-232 Serial Port to Ethernet, Terminal Server/Client. Doc No: PH232Ex1-UM-001 IPEX. (IP Electronix)

PCIe Card Selection Guide. PCIe-CAN Card. PCIe-COM Card. Taiwan Pulse Motion Co.,Ltd. Bus Interface PCI Express x 1 LPE-C122 PCE-C122D PCE-C122T

HomeVision-Serial. Add-On Card. Installation and Operation Manual

ICP PANEL-TEC PEX3000 II

Document Name : User Manual for SC10B : RS232 to Bluetooth Converter.

Parallel to Serial and Serial to Parallel Converter CE Model 232SPS2 Documentation Number 232SPS2-3903m

Product Manual. USB to Optical Adapter Industrial Isolated RS- 232/422/485. Coolgear, Inc. Version 2.1 December 2018 Model Number: USB-COMi-Si-M

3.1 I-7560 Pin Assignment and Specifications: Introduction

ZM24x Quick-Connect Industrial Modem. User s Manual

PCL Port RS-232 Interface Card

EX & EX-45362IS 2S RS232/422/485 3-in-1 Serial PCIe Card

Older Compaq UPS Family - Identifying Serial Communication Cables

GT- IRDM-9603 Product description Rev. 2 17/06/2014

AD-8923-BCD. Remote Controller (BCD) INSTRUCTION MANUAL 1WMPD

FCC Information. RoHS This product is RoHS compliant. SJ/T The following contains information that relates to China.

Zebra XiII -Series. Maintenance Manual L Rev. 2

SC32A Optically Isolated RS232 Interface

QuVIS CONNECTOR PINOUT GUIDE

RS-232 DATA COMMUNICATIONS WITH THE TANDY COLOR COMPUTER

IC-485S /IC-485SI. If anything is damaged or missing, contact your dealer.

Wiring Section 3-3. NQ-Series communication ports support various types of (serial) communication.

Programming and Using the Motorola V.3400 Modem for Remote Operation of the DDF6000

RS-232 Connector Pin Assignments

ME778C-RJ45 MAIN MODULE (FRONT CARD) MAIN MODULE. Line: RJ-45. Line: RJ-45 INTERFACE MODULE (REAR CARD) Serial: 10-Pin RJ.

MODBUS/TCP TO SIEMENS G110/G120/MM440 APPLICATION

Enhanced Mini-Chansim Model VCS-232

USER MANUAL. MODEL 1018 High Speed Short Range Modem w/ Extra Controls SALES OFFICE (301) TECHNICAL SUPPORT (301)

SC32A OPTICALLY ISOLATED RS232 INTERFACE INSTRUCTION MANUAL

SitePORTAL Lite TA-SPL32-R48

SCI-2144 SYSTEM CONTROL INTERFACE MODULE OPERATOR S MANUAL

UPort 1200/1400/1600 Quick Installation Guide

110Xi IIIPlus Maintenance Manual

ELK-IP232 INSTALLATION AND CONFIGURATION MANUAL. Ethernet to Serial Bridge /07

DIN Rail Mounted Dial-up Modem Users Manual

AB300-Series Automated Filter Wheels

EZ864 UMTS Terminal Telit Cellular GSM Engine

USB to RS-232/RS422/485. URK-228-I USB To Serial Operation Manual

UPort 1200/1400/1600 Quick Installation Guide

Section 1 Introduction

Manual Industry Interfaces

INTEGRATED SYSTEMS AND CONTROL, INC. User s Hardware Manual. PCMNET V 7. xx

Operating Instructions. Sartorius. Description of the Interface for EA, EB, GD, GE and TE Balances/Scales

edbox-100 SmartStack Box for PSTN

Powered RS Port PCIe Card

Note: For BANDIT II, BANDIT III, or VSR-1200 specifications, see the BANDIT II, BANDIT III, and VSR-1200 Document Set. Function

USB to RS-232/RS422/485. US-101-I USB To Serial Operation Manual

SPECIFICATIONS AND FEATURES GUIDE NI Serial Legacy Hardware

User s Manual INT131

Miniature Asynchronous 4-Wire High Speed Modems

RM024 DVK USER GUIDE VERSION 1.2

E Serial Controller

USB/RS232 TO cctalk COMMUNICATION BOARD Technical Information

LM058 Bluetooth Serial Adapter SMA Antenna 100m m Range SPP GAP + Wireless DTR DSR RTS CTS

The Analyst RS422/RS232 Tester. With. VTR, Monitor, and Data Logging Option (LOG2) User Manual

Domain 3000 Back Panel

FX-485PC-IF RS485 Interface Unit Hardware Manual

RS 232 to Fibre Optic Modems ELO E240, ELO E241, ELO E242. Operation manual

Frame Relay Cabling This section describes the cabling and connector pinouts for the Frame Relay cards.

EX KVIS RS232/422/485 3-in-1 Serial to USB Adapter (w/ 4KV Isolation, 15KV ESD Surge Protection)

SunSpec Reference Architecture SunSpec CEA 2045 Inverter Adaptor

Features: Analog to Digital: 12 bit resolution TTL outputs, RS-232 tolerant inputs 4.096V reference (1mV/count) 115K max speed

RS-422 Code-Operated Switches

Quick Start Guide. 2-Port 10/100 Device Server RS-232/422/485 DB9 M. Access two serial RS-232 or RS-422/485 devices over a 10- or 100-Mbps network.

Serial to RS422/485 Converter SER 485 PRO( SI) User Manual

STEP X - Name of Step QUICK START GUIDE SP385A-R3, SP390A-R3 USB TO RS CONVERTER 24/7 TECHNICAL SUPPORT AT OR VISIT BLACKBOX.

E1 and T1 RJ-48 Cable Pinouts on page 208. Fast Ethernet 12-port Cable Pinouts on page 211

Transcription:

Advanced Printer Inion Parallel Data Port Parallel Data Port The parallel data interface supports IEEE 1 bidirectional parallel communications in nibble mode. The parallel interface provides a means of communication that typically is faster than the serial interface methods. In this method, the bits of data that make up a character are sent all at one time over several wires in the cable, one bit per wire. When communicating via the parallel port, the values selected on the print engine must be the same as those used by the host equipment connected to the print engine. Port selection for status inion is determined by the channel sending the request. The parallel port can be set for bidirectional or unidirectional communication. The default setting is bidirectional. Parallel Cabling Requirements A standard -pin parallel connector is available on the back of the print engine for connection to the data source. An IEEE-1 compatible bidirectional parallel data cable is required when this communication method is used. The required cable must have a standard -pin parallel connector on one end that is plugged into the mating connector located at the rear of the print engine. The other end of the cable connects to the print engine connector at the host computer. Port selection for status inion is determined each time the print engine is turned on. Parallel Port Interconnections Table shows the pin configuration and function of a standard computer-to-printer parallel cable. Table Parallel Cable Pin Configuration -Pin Connectors Description 1 nstrobe/hostclk Data Bits 1 10 nack/ptrclk 11 Busy/PtrBusy 1 PError/ACKDataReq 1 Select/Xflag 1 nautofd/hostbusy 1 Not used 1, 1 Ground 1 + V at 0 ma The maximum current draw may be limited by option configuration. To enable this capability, a qualified service technician must install a jumper on the print engine s main logic board on JP1, pins and. 1 0 Ground P100-001 11/0/1

Advanced Printer Inion Parallel Data Port Table Parallel Cable Pin Configuration (Continued) -Pin Connectors Description 1 ninit nfault/ndataavail, Not used + V through a 1. K Resistor NSelectin/1 active 11/0/1 P100-001

0 Advanced Printer Inion Serial Data Port Serial Data Port To communicate using the serial data port of the print engine, you must choose the number of data bits, parity, and handshaking. Parity applies only to data transmitted by the print engine because the parity of received data is ignored. The values selected must be the same as those used by the host equipment connected to the print engine. Default print engine settings are 00 baud, data bits, no parity, and XON/XOFF. The print engine will accept any host setting for stop bits. Hardware Control Signal Descriptions For all RS- input and output signals, the print engine follows both the Electronics Industries Association (EIA) RS- and the Consultative Committee for International Telegraph and Telephone (CCITT) V. standard signal level specifications. When DTR/DSR handshaking is selected, the Data Terminal Ready (DTR) control signal output from the print engine controls when the host computer may send data. DTR ACTIVE (positive voltage) permits the host to send data. When the print engine places DTR in the INACTIVE (negative voltage) state, the host must not send data. Note When XON/XOFF handshaking is selected, data flow is controlled by the ASCII Control Codes DC1 (XON) and DC (XOFF). The DTR Control lead has no effect. Request To Send (RTS) is a control signal from the print engine that is connected to the Clear To Send (CTS) input at the host computer. Pin Configuration Connect the serial data cable to the female DB- connector on the back of the print engine. For all RS- connections through a DB- cable, use a DB- to DB- interface module (see DB- to DB- Connections on page ). Table shows the pin configuration of the serial data connector. Table Serial Connector Pin Configuration Pin No. Name Description 1 Unused and unterminated RXD Receive data data input to print engine TXD Transmit data data output from print engine DTR Data terminal output from print engine SG Signal ground DSR Data set input to print engine RTS Request to send output from print engine P100-001 11/0/1

Advanced Printer Inion Serial Data Port 1 Table Serial Connector Pin Configuration (Continued) Pin No. Name Description CTS Clear to send input to print engine + VDC + VDC at 0 ma The maximum current draw may be limited by option configuration. Important To enable this capability, a qualified service technician must install a jumper on the print engine s main logic board on JP1, pins and. RS- Interface Connections The print engine is configured as Data Terminal Equipment (DTE). Figure 11 shows the internal connections of the print engine s RS- connector. Note Use a null modem (crossover) cable to connect the print engine to a computer or any other DTE device. Figure 11 RS- DB MLB Connections +VDC R1 1 K 1 +VDC signal source RXD (receive data) input TXD (transmit data) output DTR (data terminal ) output SG (signal ground) DSR (data set ) input RTS (request to send) output CTS (clear to send) input +VDC signal source When the print engine is connected via its RS- interface to Data Communication Equipment (DCE) such as a modem, use a standard RS- (straight-through) interface cable. Figure 1 illustrates the connections required for this cable. 11/0/1 P100-001

Advanced Printer Inion Serial Data Port Figure 1 RS- to DCE Cable Connectors RXD (receive data) TXD (transmit data) DTR (data terminal ) SG (signal ground) DSR (data set ) RTS (request to send) CTS (clear to send) + VDC signal source DB- to DB- Connections To connect the print engine s RS- DB- interface to a DB- connector, an interface adapter is required. A generic DB- adapter can be used, although the + VDC signal source would not be passed through the adapter. Figure 1 shows the connections required for the DB- to DB- interface. Figure 1 DB- to DB- Cable Connections RXD FG 1 TXD TXD DTR RXD SG DSR RTS CTS + VDC SIGNAL RTS CTS DSR SG + VDC SIGNAL DTR 0 Modem Connection When the print engine is connected via its RS- interface to Data Communication Equipment (DCE) such as a modem, use a standard RS- (straight-through) interface cable. Figure 1 shows the connections required for this cable. P100-001 11/0/1

Advanced Printer Inion Serial Data Port Figure 1 RS- Cable Connections DTE (Printer) RXD (receive data) TXD (transmit data) DTR (data terminal ) SG (signal ground) DSR (data set ) RTS (request to send) CTS (clear to send) + VDC signal source DCE (Modem, etc.) 11/0/1 P100-001

Advanced User Inion USB.0 Port USB.0 Port A USB.0 port (which is USB 1.1 and 1.0 compatible) is available to connect your printer to the host equipment. The industry-standard USB cable has an A-male connector on one end and a B-male connector on the other end as shown in Figure 1. Figure 1 USB Connectors Printer = Computer 1 1 B male connector, attaching to printer B male connector, detail A male connector, attaching to computer A male connector, detail Maximum cable length = 1. ft. ( m) Note Use a USB.0-certified compliant cable no longer than 1. ft ( m) long. A cable that meets these requirements is available from Zebra (part number 011). P100-001 11/0/1

Advanced User Inion Applicator Interface Connector Applicator Interface Connector An external DB-1 connector is present on the rear panel of the print engine for communication with a customer applicator. An optional DB-1 to DB- adapter cable (Zebra part number 0) is available to accommodate existing DB- interfaces. The print engine ships with the following caution over the optional applicator port: For +V non-isolated mode (internal power), no configuration is necessary. For +V to +V isolated mode (external power), the jumpers on the applicator interface board must be reconfigured. Follow the instructions in Applicator Interface Board Reconfiguration on page. Applicator Signals The print engine communicates with a customer applicator through a series of signals on the pins in the DB-1 connector. Each pin causes different things to happen when the signal is active (asserted) or not active (deasserted). Applicator Interface Connector Pin Configuration on page provides additional inion about each pin and signal. The following timing diagrams show how applicator signals function in each applicator mode during the stages of printing a. Figure 1 Applicator Signals (Mode 1) sent processed waiting for start print signal prints for next DATA READY (pin 1) START PRINT (pin ) END PRINT (pin 11) not do not start start do not end end 11/0/1 P100-001

Advanced User Inion Applicator Interface Connector Figure 1 Applicator Signals (Mode ) sent processed waiting for start print signal prints for next DATA READY (pin 1) START PRINT (pin ) END PRINT (pin 11) not do not start start do not end end Figure 1 Applicator Signals (Mode ) sent processed waiting for start print signal prints for next DATA READY (pin 1) START PRINT (pin ) END PRINT (pin 11) not do not start start do not end end Figure 1 Applicator Signals (Mode ) sent processed waiting for start print signal prints for next DATA READY (pin 1) START PRINT (pin ) END PRINT (pin 11) not do not start start do not end end P100-001 11/0/1

Advanced User Inion Applicator Interface Connector Applicator Interface Connector Pin Configuration The Applicator Interface Assembly is available in two versions: a + V I/O and a +- V I/O. Table 10 lists the pin configurations and functions of the applicator interface connector for both + V and + V operation. Table 10 Applicator Interface Connector Pin Configuration Pin No. Signal Name Signal Type Description 1 I/O SIGNAL GROUND I/O Signal Ground Using jumper J, this pin can be configured as isolated or non-isolated. When in non-isolated mode, the printer s +V ground is connected to this pin. See Figure 0 on page for location of jumpers. I/O SIGNAL POWER Power Using jumper J, this pin can be configured as isolated or non-isolated. When in non-isolated mode, the printer s +V power supply is used and fused at 1 Amp. See Figure 1 on page 0 and Figure on page 1. Note Replace the fuse with one of the same type and rating only. START PRINT Input Pulse Mode The printing process begins on the HIGH to LOW transition of this signal if a is. De-assert this signal HIGH to inhibit printing of a new. Level Mode Assert LOW to enable the print engine to print if a is. When deasserted HIGH, the print engine completes the that is printing then stops and waits for this input to be reasserted LOW. FEED Input When the print engine is idle or has been paused, assert this input LOW to trigger repeated feeding of blank s. De-assert HIGH to stop feeding blank s and register to the top of the next. PAUSE Input To toggle the current Pause state, this input must be asserted LOW for 00 milliseconds, or until the SER- VICE REQUIRED output (pin 10) changes state. REPRINT Input If the Reprint feature is enabled, this input must be asserted LOW to cause the print engine to reprint the last. If the Reprint feature is disabled, this input is ignored. +V (Fused at 0.A) Note Replace the fuse with one of the same type and rating only. Power The Interface Power Supply. Supplies power to external sensors as required. Note If operating with +V signals, pin may be used to supply power to pin. However, this creates a non-isolated mode of operation with +V signals. 11/0/1 P100-001

Advanced User Inion Applicator Interface Connector Table 10 Applicator Interface Connector Pin Configuration (Continued) Pin No. Signal Name Signal Type Description POWER GROUND (+ V DC Return) Power Ground The Interface Power Ground. Note If pin is used to supply power to pin, use this pin to supply ground to pin 1. However, this creates a non-isolated mode of operation. RIBBON LOW Output Asserted LOW if the Supplies Warning feature is enabled and the amount of ribbon remaining on the supply spindle is below the threshold level. 10 SERVICE REQUIRED Output Asserted LOW in the following circumstances: the printhead is open the ribbon or media is out the print engine is paused an operational fault occurs a Resynch error occurs while the applicator Resynch mode is set to Error mode 11 END PRINT Output MODE 0 The applicator port is OFF. MODE 1 Asserted LOW only while the print engine is moving the forward; otherwise deasserted HIGH. MODE Asserted HIGH only while the print engine is moving the forward; otherwise deasserted LOW. MODE (Default) Asserted LOW for 0 milliseconds when a is completed and positioned. Not asserted during continuous printing. MODE Asserted HIGH for 0 milliseconds when a is completed and positioned. Not asserted during continuous printing. 1 MEDIA OUT Output Asserted LOW while there is no media in the print engine. 1 RIBBON OUT Output Asserted LOW while there is no ribbon in the print engine. 1 DATA READY Output Asserted LOW when sufficient data has been received to begin printing the next. Deasserted HIGH whenever printing stops after the current, due to either a pause condition or the absence of a. 1 SPARE Output Unassigned. P100-001 11/0/1