UL TEST REPORT AND PROCEDURE

Similar documents
UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE

COVER PAGE FOR TEST REPORT

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE

E A54-UL 2012-AUGUST-29 XP POWER L L C SUITE E DYER RD SANTA ANA CA 92705

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE

Page 1 of 2. Component - Power Supply SL POWER ELECTRONICS CORP 6050 KING DR. BLDG A VENTURA, CA 93003, USA

C E R T I F I C A T E O F C O M P L I A N C E

File E Project 00SC September 27, 2000 REPORT COMPONENT - POWER SUPPLIES, MEDICAL AND DENTAL EQUIPMENT

UL TEST REPORT AND PROCEDURE

File E Project 91SC COMPONENT POWER SUPPLIES INFORMATION TECHNOLOGY EQUIPMENT INCLUDING ELECTRICAL BUSINESS EQUIPMENT

DEMKO CERTIFICATE. Certificate No Page 1/3 Date of Issue Certificate Holder. Manufacturer. Production site

C E R T I F I C A T E O F C O M P L I A N C E

Page 1 of 2. Component - Power Supply SL POWER ELECTRONICS CORP BLDG A, 6050 KING ST VENTURA CA 93003, USA

Underwriters Laboratories (UL LLC) Safety Certification Report

C E R T I F I C A T E O F C O M P L I A N C E

C E R T I F I C A T E O F C O M P L I A N C E

CERTIFICATE OF COMPLIANCE

C E R T I F I C A T E O F C O M P L I A N C E

Power Supply SL POWER ELECTRONICS CORP BLDG A, 6050 KING DRIVE VENTURA CA 93003, USA

C E R T I F I C A T E O F C O M P L I A N C E

UL TEST REPORT AND PROCEDURE

IEC Medical electrical equipment Part 1: General requirements for basic safety and essential performance

C E R T I F I C A T E O F C O M P L I A N C E

Page 1 of 2. Power Supply SL POWER ELECTRONICS CORP 6050 KING DRIVE, BLDG A VENTURA CA 93003, USA

IEC60601_1K. Medical electrical equipment Part 1: General requirements for basic safety and essential performance

C E R T I F I C A T E O F C O M P L I A N C E

C E R T I F I C A T E O F C O M P L I A N C E

Certificate of Compliance

File E Project 89ME November 30, 1989 REPORT COMPONENT - POWER SUPPLY. Vicor Corp. Andover, MA

UL TEST REPORT AND PROCEDURE

File E Project 90ME March 12, 1991 REPORT

File E Project 11SC May 15, 2012 REPORT COMPONENT DRIVERS FOR LIGHT-EMITTING-DIODE ARRAYS, MODULES AND CONTROLLERS

File E Project 01ME October 15, 2001 REPORT

High Performance Network Isolator

Certificate of Compliance

SPECIFICATION FOR APPROVAL AC/DC ADAPTOR

C E R T I F I C A T E O F C O M P L I A N C E

File E Project 93ME39941, Issued: November 29, 1993 New: April 26, 2006 REPORT COMPONENT - POWER SUPPLIES. For Use In

IEC An introduction. 28 March 2012 By Craig McKee Technical Manager

EMOSAFE EN-100 Network Isolators for PCB assembly

EMOSAFE EN-30 1 FEATURES AND ADVANTAGES 2 GENERAL DESCRIPTION. Product Datasheet. Gigabit Network Isolator in aluminium housing December 2015 ENGLISH

Datasheet - SRB 402EM-24V

INSTITUTE OF TESTING AND CERTIFICATION (INDIA) PVT. LTD.

Datasheet - SRB 301LC/B-24V

KUANTECH (SHEN ZHEN) COMPANY LIMITED KSAFD W1UK

Procedure And/Or Report Material

File E Project 03ME REPORT COMPONENT - POWER SUPPLIES, INFORMATION TECHNOLOGY EQUIPMENT, INCLUDING ELECTRICAL BUSINESS EQUIPMENT

File E Project 91SC Issued: July 4, 1991 Revised: August 23, 2007 REPORT

Safety Standards. Model Number:

EMOSAFE EN-85e Network Isolator with Overtension Auto-Release

Datasheet SRB301ST 24V (V.2)

Electrical Specifications. Input Input range: Vac Hz, single phase AC. 92% typical at high line 50% load. FCC Subpart J EN55022 Class A

40 & 60 Watt Models. Low Leakage Current. EN61000 Compliant. Single & Multiple Outputs. Cover Kits Available

EMOSAFE EN-10 Network Isolators with Protected Connector

CONTENTS 3 EN :2006

D15CC55UNVD K/KS. UNV DALI Dimming LED Driver 1500mA Constant Current Output Class 2, 55W Output DALI Dimming to 1% Performance.

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

With the exception of EN-70e, which provides a dielectric strength of only 4.6 kv AC, and does not provide any transient voltage suppression.

400AUS24 B MDS AUS. MDS Medical AC-DC Open Frame 24Volt, 400Watt / MDS-400AUS24 B. General Description. Model Information. Model Numbering ```

Application Switchgear for industrial and advanced commercial applications. U e V AC 240/ (per pole) I cs 7,5 ka

Notes: Note1: Other output voltages on request Note2: Efficiency is tested at nominal input (115/230VAC) and full load at +25 C ambient

File E Project 03ME Issued: March 4, 2004 REPORT COMPONENT - POWER SUPPLIES, SPECIALTY - COMPONENT

Manual Supplement. This supplement contains information necessary to ensure the accuracy of the above manual.

060AAS19 B MDS. MDS Medical AC-DC Adapter 19Volt, 60Watt / MDS-060AAS19 B. Highlights & Features. Safety Standards. Model Number: General Description

100BPS15 B. MDS Medical AC-DC Open Frame 15Volt, 100Watt / MDS-100BPS15 B ``` Highlights & Features. Safety Standards.

Please use the Q & A utility to ask us any questions concerning the material being presented.

The Solid-State Decoupler (SSD)

040APS12 B MDS. MDS Medical AC-DC Open Frame 12Volt, 40Watt / MDS-040APS12 B ``` Highlights & Features. Safety Standards.

Test Report S

Page 1 of 5. Increased Safety, Encapsulation and Dust

Standards Update Notice (SUN) Issued: April 25, 2017

EMOSAFE EN-60KDS 1 FEATURES AND ADVANTAGES 2 GENERAL DESCRIPTION. Product Datasheet. Keystone Network Isolator with Cable December 2015 ENGLISH

Explosion-Protected Arc-Fault Protection ExAFCI Arc-Fault Circuit Interrupter

GETTING STARTED GUIDE NI Channel Solid-State Relay (SSR) Digital Output Module

400AUS24 B MDS AUS. MDS Medical AC-DC Open Frame 24Volt, 400Watt / MDS-400AUS24 B. General Description. Model Information. Model Numbering ```

PanelView Plus/VersaView CE Terminals and Display Modules

Safety Standards. Model Number:

Standards Update Notice (SUN) Issued: August 11, 2017

SECTION TRANSIENT VOLTAGE SUPPRESSION FOR LOW-VOLTAGE ELECTRICAL POWER CIRCUITS

C B. Models. Operating up to 5000m altitude 5 year product warranty

PERMANENT DOCUMENT. Annex AU to Routine Test Requirements for manufacturers (as per Article 9 of the Agreement)

TECHNICAL DATASHEET MDS Medical AC-DC Open Frame 065APS24 B Highlights & Features Safety Standards Model Number: Unit Weight Dimensions (W x L x H):

Safety Standards. Model Number:

Electrical Specifications. Input Input range Vac Frequency. 90% typical at full load, nominal line. FCC Subpart J EN55022 Class B

Transcription:

Issue Date: 2014-10-31 Page 1 of 18 Report Reference # E182560-A123-UL UL TEST REPORT AND PROCEDURE Standard: Certification Type: CCN: ANSI/AAMI ES60601-1 (2005 + C1:09 + A2:10)(Medical Electrical Equipment - Part 1: General Requirements for Basic Safety and Essential Performance) CAN/CSA-C22.2 No. 60601-1 (2008) (Medical Electrical Equipment - Part 1: General Requirements for Basic Safety and Essential Performance) Component Recognition QQHM2, QQHM8 (Power Supplies, Medical and Dental) Product: Model: Switching Power Supply LCC600-28U-XX, LCC600-36U-XX, LCC600-48U-XX (where XX can 4P or 9P) Rating: LCC600-28U-XX (where XX can 4P or 9P) AC Input: 100-240Vac, 50/60Hz, 10A MAX DC Output: +28VDC, 25A MAX, +5Vsb, 1.5A MAX. LCC600-36U-XX (where XX can be 4P or 9P) AC Input: 100-240Vac, 10A Max, 50/60Hz DC Output: +36V, 16.7A Max +5Vsb, 1.5A Max LCC600-48U-XX (where XX can be 4P or 9P) AC Input: 100-240Vac, 10A Max, 50/60Hz DC Output: +48V, 12.5A Max +5Vsb, 1.5A Max MAX. TOTAL OUTPUT POWER: 600W Applicant Name and Address: ASTEC INTERNATIONAL LTD - PHILIPPINE BRANCH 16TH FL LU PLAZA 2 WING YIP ST KWUN TONG KOWLOON HONG KONG This is to certify that representative samples of the products covered by this Test Report have been investigated in accordance with the above referenced Standards. The products have been found to comply with the requirements covering the category and the products are judged to be eligible for Follow-Up Service under the indicated Test Procedure. The manufacturer is authorized to use the UL Mark on such products which comply with this Test Report and any other applicable requirements of UL LLC ('UL') in accordance with the Follow- Up Service Agreement. Only those products which properly bear the UL Mark are considered as being covered by UL's Follow-Up Service under the indicated Test Procedure. The applicant is authorized to reproduce the referenced Test Report provided it is reproduced in its entirety. Copyright 2015

Issue Date: 2014-10-31 Page 2 of 18 Report Reference # E182560-A123-UL UL authorizes the applicant to reproduce the latest pages of the referenced Test Report consisting of the first page of the Specific Technical Criteria through to the end of the Conditions of Acceptability. Any information and documentation involving UL Mark services are provided on behalf of UL LLC (UL) or any authorized licensee of UL. Prepared by: Clare He Reviewed by: Sammi Liang Copyright 2015

Issue Date: 2014-10-31 Page 3 of 18 Report Reference # E182560-A123-UL Supporting Documentation The following documents located at the beginning of this Procedure supplement the requirements of this Test Report: A. Authorization - The Authorization page may include additional Factory Identification Code markings. B. Generic Inspection Instructions - i. Part AC details important information which may be applicable to products covered by this Procedure. Products described in this Test Report must comply with any applicable items listed unless otherwise stated in the body of this Test Report. ii. Part AE details any requirements which may be applicable to all products covered by this Procedure. Products described in this Test Report must comply with any applicable items listed unless otherwise stated in the body of each Test Report. iii. Part AF details the requirements for the UL Certification Mark which is not controlled by the technical standard used to investigate these products. Products are permitted to bear only the Certification Mark(s) corresponding to the countries for which it is certified, as indicated in each Test Report.

Issue Date: 2014-10-31 Page 4 of 18 Report Reference # E182560-A123-UL Product Description This unit is a medical switching mode power supply for building-in which has been evaluated for use in Class I medical application. Unit provided with insulation transformers and all components are mounted on 94V-0 PWB. Model Differences Model LCC600-28U-4P is similar to LCC600-28U-9P except for the input connector is used on model LCC600-28U-9P instead of input cord used for LCC600-28U-4P, and the output connector is used on model LCC600-28U-9P instead of output cord used for LCC600-28U-4P. Model LCC600-28U-XX is identical to Model LCC600-48U-XX except for the following safety controlled parameters. 1. Model name. 2. Ratings of DC Output, input connector 3. Power transformer (T204) Model LCC600-28U-XX and LCC600-48U-XX is identical to Model LCC600-36U-XX except for the following safety controlled parameters. 1. Model name. 2. Ratings of DC Output 3. Power transformer (T204),alternate source of MOV101 4. LCC600, 9P version has two input connector option: Input Connector (J101) and Input cord with input connector (Optional). Technical Considerations Classification of installation and use : For built-in Device type (component/sub-assembly/ equipment/ system) : Component Intended use (Including type of patient, application location) : Recognized power supply for medical equipment usage Mode of operation : Continuous Supply connection : Permanently installed for LCC600-28U-4P, LCC600-36U-4P and LCC600-48U- 4P / Input connector for LCC600-28U-9P, LCC600-36U-9P and LCC600-48U-9P Accessories and detachable parts included : None Other options include : None The product was investigated to the following additional standards:: CAN/CSA-C22.2 No. 60601-1 (2008) (Medical Electrical Equipment - Part 1: General Requirements for Basic Safety and Essential Performance) Edition 2 - Revision Date 2011/06/01, ANSI/AAMI ES60601-1 (2005 + C1:09 + A2:10) (Medical Electrical Equipment - Part 1: General Requirements for Basic Safety and Essential Performance) - Edition 1 - Revision Date 2012/01/01 The product was not investigated to the following standards or clauses:: Biocompatibility (ISO 10993-1), Clause 14, Programmable Electronic Systems, Electromagnetic Compatibility (IEC 60601-1-2) The degree of protection against harmful ingress of water is:: Ordinary The mode of operation is:: Continuous The product is suitable for use in the presence of a flammable anesthetics mixture with air or oxygen or with nitrous oxide:: No Engineering Conditions of Acceptability For use only in or with complete equipment where the acceptability of the combination is determined by UL

Issue Date: 2014-10-31 Page 5 of 18 Report Reference # E182560-A123-UL LLC. When installed in an end-product, consideration must be given to the following: This power supply has been judged on the basis of the required creepage and clearances in the First Edition of the Standard for Medical Electrical Equipment, ANSI/AAMI ES 60601-1, Sub clause 8.9. This power supply has been evaluated as a Class I, continuous operation, ordinary Equipment and has not been evaluated for use in the presence of a flammable anesthetic mixture with air, oxygen, or nitrous oxide. An additional evaluation shall be made if the power supply is intended for use in other than Class I equipment. This power supply was tested on a 30A branch circuit. If used on a branch circuit greater than this, additional testing may be necessary. The power supply was evaluated as 2 MOPP between Primary to Secondary and 1 MOPP from Primary to Earth, see insulation diagram for details. Consideration should be given to measuring the temperatures on power electronic components and transformer windings when the power supply is installed in the end use equipment. The transformers (T204, T301, T501) incorporate a Class 155 (F) insulation system. The secondary circuit of this power supply has not been evaluated for patient connected applications. The following tests shall be performed in the end-product evaluation: Earthing and Potential Equalization Test, Temperature Test, Dielectric Voltage Withstand Tests, Leakage Current Test with Normal MD, Non-frequency-weighted MD and Fuse Short Circuit Test. For Model LCC600-28U-XX, the maximum working voltage for T501 is 377 Vrms, 663 Vpk, for LCC600-48U-XX T501 is 391 Vrms, 681 Vpk and for Model LCC600-36U-XX T501 is 382.8 Vrms, 660 Vpk. The electric withstand test in the end-product shall be based on this value. This power supply shall be installed in compliance with the enclosure, mounting, spacing, casualty, markings and segregation requirements of the end use application. A suitable Mechanical, Electrical and Fire enclosure shall be provided in the end-use product. This power supply is operated up to 5000m above sea level as declared by manufacturer. Separation from secondary to earth need to evaluated in end product. End product Risk Management Process to include consideration of requirements specific to the Power Supply and the suitability of Fuse. The terminals and connectors have not been evaluated for field wiring. End product Risk Management Process to consider the need for simultaneous fault condition testing. End product Risk Management Process to consider the need for different orientations of installation during testing. End product to determine the acceptability of risk in conjunction to insulation to resistance to heat, moisture, and dielectric strength. End product to determine the acceptability of risk in conjunction to the movement of components and conductors as part of the power supply. End product to determine the acceptability of risk in conjunction to the routing of wires away from moving parts and sharp edges as part of the power supply. Temperature Test was conducted without Test Corner. End product to determine the acceptability of risk in conjunction to temperature testing without test corner as part of the power supply. End product to determine the acceptability of risk in conjunction to the Cleaning and Disinfection Methods as part of the power supply. End product to determine the acceptability of risk in conjunction to the Leakage of Liquids as part of

Issue Date: 2014-10-31 Page 6 of 18 Report Reference # E182560-A123-UL the power supply. End product to determine the acceptability of risk in conjunction to the Arrangement of Indicators as part of the power supply. End product to determine the acceptability of risk in conjunction to the results of Mechanical Testing conducted as part of the power supply. End product to determine the acceptability of risk in conjunction to the selection of components as it pertains to the intended use, essential performance, transport, storage conditions as part of the power supply. The end-product evaluation shall ensure that the requirements related to Accompanying Documents, Clause 7.9 are met. This power supply has two fuses (F101, F102) rated 12.5A, 250Vac connected in Live and Neutral. The power supply shall be properly bonded to the main earthing termination in end-use. Maximum ambient temperature is 70 degree C with the temperature of baseplate at 85 degree C. MOPP BF dielectric strength test (1500Vrms) was conducted between secondary and PE on the power supply. Minimum Trimming Voltage (+44V output) for Model LCC600-48U-XX limited to 550 W max output power and +32V output (for Model LCC600-36U-XX) limited to 535 W max output power. Table represents the derating power and allowable baseplate temperature for Model LCC600-48U- XX and LCC600-36U-XX, Input (Vac) Pout (W) Base Plate Temp (deg C), 90-104 600 70, 90-104 550 85, 105-264 600 85 and, 90-264 535 85 (For Model LCC600-36U-XX only). Hi-pot Voltage 1500Vac was performed between Secondary Circuit to Protective Earth. Additional Information Project 4786833275: 1. Alternate new model LCC600-36U-XX (where XX can 4P or 9P) with new transformer, which is identical to the UL approved model LCC600-28U-XX (where XX can 4P or 9P). 2. Alternate Marking Label Sources Model (s) FLEXLBL1, FLEXLBL2 from Nameplates For Industry Inc (MH12578, PGDQ2). Project 4786660417: Alternate new model LCC600-48U-XX (where XX can 4P or 9P) with new transformer, which is identical to the UL approved model LCC600-28U-XX (where XX can 4P or 9P). Project 4786946222: 1) Alternate triple insulation wire for transformer (T204) - MFR: Hoi luen Electrical Manufacturer, Model: THL-F - MFR: Draka Automotive GMBH, Model: 8Y13 - MFR: New England Wire Technologies, Model: ETFE - MFR: Totoku Electric Co Ltd, Model TIW-3 2) Alternate Top Cover Enclosure for LCC600-28U-4P,LCC600-48U-4P and LCC600-36U-4P: Aluminium Alloy ADC12 3) Alternate insulator to critical component table - Insulator Barrier for Transformer Mainboard: MFR: E I Dupont, Model: FR530 - Insulator for EMI board: MFR: E I Dupont, Model: FR530 & MFR: Toray Industries INC, Model: Lumirror S10 - Insulator for Top Cover Enclosure for LCC600-28U-4P,LCC600-48U-4P and LCC600-36U-4P: Toray

Issue Date: 2014-10-31 Page 7 of 18 Report Reference # E182560-A123-UL Industries INC, Model: Lumirror S10 4) Added alternate Marking Label: MRF: Adampak Ltd, Model: 89A - For all labels source: add "aluminium" into technical consideration in critical component list 5) Correct following typing error - Revised the description for the rating: Added "Max" behind 10A - Added "with input connector" to Input Cord in critical component list - For Input Connector (For LCC600-36U-9P only) in critical component list: Deleted "(For LCC600-36U-9P only" - For Power Transformer (T204) (For Model LCC600-48U-XX) in critical component list: Corrected "4-17" to "4-33"; - Added "LCC600-36U-4P" to input cord, output cord, top cover enclosure((lcc600-28u-4p and LCC600-48U-4P only) in critical component list - Added "LCC600-36U-9P" to top cover enclosure((lcc600-28u-9p and LCC600-48U-9P only) in critical component list - Revised the description for the insulation diagram table: Corrected the "C" to "E" for T501(primary to secondary) - For diagram 4-16 in enclosure table: Corrected the "4P" to "9P" - Added the test data for Marking Label in test table 7.1.3: MRF: INDUSTRY INC. Model: FLEXLBL1, FLEXLBL2 SR 2881156.732318: Correct Typo Error in Test Record 2 for Project 4786660417 (E182560-A123) Note: Change word "identical" to "similar". Additional Standards The product fulfills the requirements of: CAN/CSA-C22.2 No. 60601-1 (2008) (Medical Electrical Equipment - Part 1: General Requirements for Basic Safety and Essential Performance) Edition 2 - Revision Date 2011/06/01 Markings and instructions Clause Title Company identification Model Supply Connection Supply Frequency Alternating current Marking or Instruction Details Classified or Recognized company's name, Trade name, Trademark or File Model number Voltage range, ac/dc, phases if more than single phase Rated frequency range in hertz Direct current Power Input Output Amps, VA, or Watts Rated output voltage, power, frequency.

Issue Date: 2014-10-31 Page 8 of 18 Report Reference # E182560-A123-UL Protective earth ground Special Instructions to UL Representative N/A Production-Line Testing Requirements Test Exemptions - The following models are exempt from the indicated test Model Grounding Continuity Dielectric Voltage Withstand Patient Circuit Dielectric Voltage Withstand LCC600-28U-4P Not Exempted Not Exempted Exempted LCC600-28U-9P Not Exempted Not Exempted Exempted LCC600-48U-4P Not Exempted Not Exempted Exempted LCC600-48U-9P Not Exempted Not Exempted Exempted LCC600-36U-4P Not Exempted Not Exempted Exempted LCC600-36U-9P Not Exempted Not Exempted Exempted Solid-State Component Test Exemptions - The following solid-state components may be disconnected from the remainder of the circuitry during either Dielectric Voltage Withstand Test: Component -- Sample and Test Specifics for Follow-Up Tests at UL The following tests shall be conducted in accordance with the Generic Inspection Instructions Plastic Enclosure or Part Test Sample(s) Test Specifics -- -- -- --