MODEL: R1M-A1. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

Similar documents
MODEL: R1M-D1. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

MODEL: R1M-P4. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

MODEL: R1M-GH. PC Recorders R1M Series

MODEL: R2K-1 SEN TRONIC AG. R2K Series

R1M-GH THERMOCOUPLE & DC INPUT MODULE MODEL. Remote I/O R1M Series. (16 points)

R1M-GH BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL PC RECORDER MODEL. (thermocouple or DC input, 16 points)

MODEL: GR8-EM. Communication Adaptor GR8 Series

R1M-GH BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL PC RECORDER MODEL. (thermocouple or DC input, 16 points)

MODEL: M1EXV. OUTPUT Field-selectable DC Output Current output: 0-20 ma DC Voltage output: V DC Voltage output: V DC

MODEL: M2EXM. Super-mini Signal Conditioners with Display Mini-M M2E Series

MODEL: R3-NE1. Remote I/O R3 Series. ETHERNET INTERFACE MODULE (Modbus/TCP) 27.5 (1.08)

MODEL: M1EXM. OUTPUT Field-selectable DC Output Current output: 0-20 ma DC Voltage output: V DC Voltage output: V DC

MODEL: 47LYV. Digital Panel Meters 47 Series

MODEL: M5DY SEN TRONIC AG CURRENT LOOP SUPPLY. [2] POWER INPUT AC Power M: V AC (Operational voltage range V, Hz)

MODEL: MDCAT. Lightning Surge Protectors for Electronics Equipment M-RESTER

MODEL: MDCAT. Lightning Surge Protectors for Electronics Equipment M-RESTER

MODEL: SC100. Single Loop Controller Series. MULTI-FUNCTION PID CONTROLLER (color LCD with touch-panel) MODEL: SC100 [1]0 [2][3]

MODEL: R3-NL1. RELATED PRODUCTS XIF File (Device Interface File) XIF file is used to define a LonWorks device when programmed on LonMaker.

MODEL: 43AL1. Digital Panel Meters 43 Series

R: Red Y: Amber G: Green B: Blue W: White. R: Red Y: Amber G: Green B: Blue W: White. R: Red Y: Amber G: Green B: Blue W: White.

MODEL: R3-NL2. RELATED PRODUCTS XIF File (Device Interface File) XIF file is used to define a LonWorks device when programmed on LonMaker.

MODEL: 40DN. Digital Panel Meters 40 Series

MODEL: 40DR SEN TRONIC AG. Digital Panel Meters 40 Series

MODEL: IT40SW2. Tower Light Series. [2] LAMP 1 COLOR (1st layer from the top) R: Red Y: Amber G: Green B: Blue W: White

MODEL: MD7TC. Lightning Surge Protectors for Electronics Equipment M-RESTER

MODEL: 40DV SEN TRONIC AG. Digital Panel Meters 40 Series

MODEL: WL40EW2F. Wireless I/O WL40F Series

DAL4 REPEATER MODEL. (SIN-NET, M-Bus use) MODEL & SUFFIX CODE SELECTION DAL4 TRANSMISSION ORDERING INFORMATION RELATED PRODUCTS GENERAL SPECIFICATIONS

MODEL: R3-NFL1. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.) Remote I/O R3 Series

R1M-J3 BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL RTD & POTENTIOMETER INPUT MODULE MODEL. (8 points)

R3-NE1 ETHERNET INTERFACE MODULE MODEL. Remote I/O R3 Series. (Modbus/TCP)

MODEL: CND. Multiplex Transmission System

Measuring transducers MI4x0 series Programmable transducers for RTD sensors MI450

MODEL: MD7ST. [3] LOOP DISCONNECT FUSE 0: Without 1: With (CENELEC/ATEX approval Not selectable)

AD-8923-BCD. Remote Controller (BCD) INSTRUCTION MANUAL 1WMPD

MIC-2 MKII, Multi-instrument DATA SHEET

SSI-1016H Specifications and Operation Manual

DLS-E2 TELEMETERING UNIT BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL MODEL. (16 contact inputs & 16 open collector outputs)

MODEL: 6DV-B. [2] TERMINAL BLOCK 0: None (Euro terminal block at the rear of indicator module)

OHIO SEMITRONICS, INC. AC MULTIFUNCTION PROGRAMMABLE TRANSDUCERS & -1000L

MODEL: 43DV2. Digital Panel Meters 43 Series

MODEL: 6DV-B. [2] TERMINAL BLOCK 0: None (Euro terminal block at the rear of indicator module)

CONTENTS 1. BEFORE USE GENERAL DESCRIPTION POINTS OF CAUTION HARDWARE SPECIFICATIONS... 4

OTB1S0DM9LP I/O distributed module OTB - Modbus non isolated serial link m

OTB1S0DM9LP I/O distributed module OTB - Modbus non isolated serial link m

TABLE OF CONTENTS. Communication Functions

Network Instrumentation Module Communications box NX-CB1 Communications adapter NX-CL1/NX-CR1 Terminal adapter NX-TL1/NX-TR1

Modbus Digital Remote I/O. ARM Series. Modbus Sensor Connector Type Digital Remote I/O. Features. User Manual For Communication. Ordering Information

Energy Management Modular DC Energy analyzer Type VMU-E and VMU-X

Appearance Size (mm) Power supply voltage Model (W H D) 100 to 240 VAC K3SC to 240 VAC

SYSMAC Remote Transistor Module

ICD105A 1008 page 1/ r001 ICD105A. Industrial RS-232 to RS-422/485 Converter

R7D-RR8 BEFORE USE... POINTS OF CAUTION. INSTRUCTION MANUAL REMOTE CONTROL RELAY CONTROL MODULE, 8 points MODEL. (DeviceNet)

MIC-2 MKII & MIC-2 MKII DIN, Multi-instrument DATA SHEET

MODEL: DL8. POWER INPUT DC power R: 24 V DC (Operational voltage range: ±10 %; ripple 10 %p-p max.) Web Data Logger DL8

Power Transducers. Measuring most electrical parameters

FX-485PC-IF RS485 Interface Unit Hardware Manual

Rotary Measuring Technology Absolute encoders, Multiturn, optional with incremental track

Power Supplies. PS5R Standard Series Switching Power Supplies. Part Numbers. Part Number

DEIF A/S. MIC Multi-instrument G. Data sheet. Features. Accuracy. Measurements. Installation. Intelligent. Display. Communication DEIF A/S

IST ULTRASTAB Power Supply for high precision transducers

G9SA. Ordering Information. Safety Relay Unit. The G9SA Series Offers a Complete Line of Compact Units. H Several types of 45-mm wide Units are

Energy Management Energy Transducer Type ET112

Communication Controller CC-Link/CPL Converter CMC10A

PHOENIX CONTACT Features

Main contacts Auxiliary contact Number of input channels Rated voltage Model Category 24 VAC/VDC 3PST-NO SPST-NC 1 channel or 2 channels possible

USER'S GUIDE FX-485ADP COMMUNICATION ADAPTER FX0N-485ADP COMMUNICATION ADAPTER

BEFORE USE... POINTS OF CAUTION. INSTRUCTION MANUAL PNP TRANSISTOR OUTPUT MODULE, 16 points (MECHATROLINK-I / -II, short circuit protection)

Voltage Current Front-mounting bracket

Energy Management Modular DC Energy analyzer Type VIM-E and VIM-X

Page Housing Plastic Metal Mounting DIN Rail or surface mount Panel or bracket mount Wattage Range 10W to 240W 7.5W to 240W 10W to 300W

INSTALLATION MANUAL. LC 200 Electronic Overload Guard. Software versione PW0501 R 0.3

PGR-4300 MANUAL GENERATOR GROUND-FAULT RELAY

MODEL: M8BS-16. [3] OPTIONS blank: none /Q: With options (specify the specification)

ICF-1150 Series Quick Installation Guide

MIC-2 Multi-instrument DATA SHEET

Advant OCS. The Compact and Cost Effective Advant Controller. Advant Controller 210. Open Control System

IST ULTRASTAB Power Supply for IT/ITN ULTRASTAB transducers

PGR-3200 MANUAL INSULATION MONITOR

Communications & Networking

QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB PM Series Power Meter. Safety Information. Equipment Maintenance and Service.

Thread length (overall length) material

485DRCI. Industrial RS-232 to RS-422/485 Converter B&B ELECTRONICS PRODUCT INFORMATION. Specifications Serial Technology

SensoTrans DMS A 20220

F150 Vision Controller with integrated PROFIBUS-DP unit. 9-pin female sub-d connector (RS-485 ProfiBus) Bus termination

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

DPST-NO None 2 channels Auto-reset Inverse (+/-) 24 VAC/VDC 4 G9SB-2002-A 1 channel or 2

EM270. Multi-channel power analyzer. Benefits. Description

RoHS. Shock / vibration resistant. Short circuit proof. Flexible. . XXXX e. . XXXX e

MED102A. Industrial Serial to Single-mode Fiber Converter

Absolute Encoders Multiturn

Electronic timer CT-ERD.12

IO-DI8-TO8 I/O Expansion Module 8 Inputs, 8 Outputs

Programmable Relay ZEN V2 Units

Signal Doublers. VariTrans A 20300

Energy meters Single phase electrical energy meters WM1-6 / WM1M6

Blue ID Communication module RS485 SC44

RS232C/RS485 Data can be easily monitored by LAN

VMU-MC and VMU-OC. Pulse concentrator. Benefits. Description

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions

Transcription:

PC Recorders R1M Series PC RECORDER (contact input, 32 points) Functions & Features Industrial recorder on PC 32-point dry contact inputs Easy system expansion via Modbus RTU Recorded data exportable to spreadsheet applications SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.) /C01: Silicone coating /C02: Polyurethane coating /C03: Rubber coating RELATED PRODUCTS Connector terminal block (model: CNT) Special cable (model: FCN32) 175 (6.89) 115 (4.53) 40 (1.57) mm (inch) MODEL: R1M-A1[1]-[2][3] ORDERING INFORMATION Code number: R1M-A1[1]-[2][3] Specify a code from below for each [1] through [3]. (e.g. R1M-A1T-M2/MSR/Q) Specify the specification for option code /Q (e.g. /C01) [1] FIELD TERMINAL TYPE T: M3 screw terminals C1: FCN type connector (No CE conformance) [2] POWER INPUT AC Power M2: 100 240 V AC (Operational voltage range 85 264 V, 47 66 Hz) DC Power R: 24 V DC (Operational voltage range 24 V ±10 %, ripple 10 %p-p max.) [3] OPTIONS (multiple selections) PC Recorder Software Package (must be specified) /MSR: With Other Options blank: none /Q: Option other than the above (specify the specification) PACKAGE INCLUDES... PC Recorder Software CD 9-pin D-sub connector, straight type (1 m or 3.3 ft) GENERAL SPECIFICATIONS Connection Power input, transmission: Euro type connector terminal (Wire size AWG24-12 (0.2 2.5 mm 2 ), stripped length 7 mm) : 9-pin D-sub connector (male) (Lock screw No. 4-40 UNC) Input: M3 screw terminals (torque: 0.6N m) or FCN type connector (Fujitsu FCN-365P040-AU) Screw terminal: Nickel-plated steel Housing material: Flame-resistant resin (gray) Isolation: Input to or to power Count memory at power loss: Count value is not saved when the power supply is lost. Node address setting: Rotary switch; 1 F (15 nodes) RUN indicator LED: Green light blinks in normal conditions. COMMUNICATION Baud rate: 38.4 kbps Communication: Half-duplex, asynchronous, no procedure Protocol: Modbus RTU Standard: Conforms to, EIA Transmission distance: 10 meters max. Standard: Conforms to TIA/EIA-485-A Transmission distance: 500 meters max. Transmission media: Shielded twisted-pair cable (CPEV-S 0.9 dia.) INPUT SPECIFICATIONS Input: Dry contact, 32 points Commons: All negatives Sensing: Approx. 5 V DC (pull-up resistance 22 kω) 1.5 V at ON 4 V at OFF http://www.m-system.co.jp/ R1M-A1 SPECIFICATIONS ES-5660 Rev.17 Page 1/6

Sampling rate: 50 msec. Totalizing Counter Function Number of input channels: 16 (ch.1 thr. 16 available both with instantaneous status and totalized value) Max. input frequency: 100 Hz Minimum pulse width: 5 ms Counter reset input: Pulse rising (ch.32 assigned) Max. counter value: 999 999 999 (reset to zero at overflow) INSTALLATION Power consumption AC: Approx. 10 VA DC: Approx. 7 W Operating temperature: -5 to +60 C (23 to 140 F) Operating humidity: 30 to 90 %RH (non-condensing) Mounting: Surface or DIN rail Weight: 400 g (0.88 lb) PERFORMANCE Multi-transmission time: 5 msec. Insulation resistance: 100 MΩ with 500 V DC Dielectric strength: 2000 V AC @ 1 minute (input to RS-232- C or to power to FG) STANDARDS & APPROVALS EU conformity: EMC Directive EMI EN 61000-6-4 EMS EN 61000-6-2 Low Voltage Directive EN 61010-1 Installation Category II Pollution Degree 2 Input or / to power: Reinforced insulation (300 V) Input to /: Basic insulation (300 V) RoHS Directive EN 50581 http://www.m-system.co.jp/ R1M-A1 SPECIFICATIONS ES-5660 Rev.17 Page 2/6

PC RECORDER SOFTWARE PC Recorder Software Package (model: MSRPAC-2010) is included with purchases of this model. Refer to the MSRPAC-2010 data sheet for the contents of the package and the requirements for the PC to be prepared by the user. EXTERNAL VIEW Power Terminals 9-pin Connector RUN Indicator LED Connector Node Address Setting Rotary SW Configurator Jack INTERFACE 1 5 ABBR. 6 9 PIN NO. EXPLANATION OF FUNCTION BA (SD) 2 Transmitted Data BB (RD) 3 Received Data AB (SG) 5 Signal Common CB (CS) 7 Clear to Send CA (RS) 8 Request to Send 1 Not Used. 4 DO NOT connect. Connecting may 6 cause malfunctions. 9 MODBUS WIRING CONNECTION CONNECTOR R1M T3 R1M R1M * 1 T3 T3 * 1 FG *2 *1. Internal terminating resistor is used when the device is at the end of a transmission line. *2. Install shielded cables to all sections and ground them at single point. http://www.m-system.co.jp/ R1M-A1 SPECIFICATIONS ES-5660 Rev.17 Page 3/6

CONNECTION DIAGRAM Note: In order to improve EMC performance, bond the FG terminal to ground. Caution: FG terminal is NOT a protective conductor terminal. FCN TYPE CONNECTOR M3 SCREW TERMINALS CN1 CN2 ch.1 ch.2 ch.3 ch.4 ch.5 ch.6 ch.7 ch.8 ch.9 ch.10 ch.11 ch.12 ch.13 ch.14 ch.15 ch.16 ch.17 ch.18 ch.19 ch.20 ch.21 ch.22 ch.23 ch.24 ch.25 ch.26 ch.27 ch.28 ch.29 ch.30 ch.31 Count Reset Input ch.32 A1 A2 A3 A4 A5 A6 A7 A8 A9 A10 A11 A12 A13 A14 A15 A16 B1 : B16 A1 A2 A3 A4 A5 A6 A7 A8 A9 A10 A11 A12 A13 A14 A15 A16 B1 : B16 Input Circuit ch.1 ch.2 ch.3 ch.4 ch.5 ch.6 ch.7 ch.8 ch.9 ch.10 ch.11 ch.12 ch.13 ch.14 ch.15 ch.16 ch.17 ch.18 ch.19 ch.20 ch.21 ch.22 ch.23 ch.24 ch.25 ch.26 ch.27 ch.28 ch.29 ch.30 ch.31 Count Reset Input ch.32 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 Input Circuit Output Circuit Term. Resist. Power Circuit T3 T5 T6 T7 * When the device is located at the end of a transmission line via twisted-pair cable, (when there is no cross-wiring), close across the terminal T3 with the attached jumper pin (or with a leadwire). When the device is not at the end, remove the jumper pin. D-SUB CONNECTOR + U (+) V ( ) FG Shielded Twisted-pair Cable To Other PC Recorders Jumper* POWER http://www.m-system.co.jp/ R1M-A1 SPECIFICATIONS ES-5660 Rev.17 Page 4/6

EXTERNAL DIMENSIONS & TERMINAL ASSIGNMENTS unit: mm (inch) M3 SCREW TERMINALS MODEL: R1M-A1 175 (6.89) 10 (.39) 165 (6.50) T3 T5 T6 T7 3 5 (.20) dia. MTG HOLES 15.5 (.61) 46 (1.81) 105 (4.13) 104 (4.09) DIN RAIL 35 mm wide 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 35 14 (.55) 163 (6.42) FOR WALL MOUNT. 3 (.12) 40 (1.57) [6 (.24)] 6.2 (.24) 36 M3 INPUT TERMINALS FCN TYPE CONNECTOR 175 (6.89) 40 (1.57) 10 (.39) 165 (6.50) T3 T5 T6 T7 3 5 (.20) dia. MTG HOLES 15.5 (.61) 46 (1.81) Connector Pin Assignment A1 B1 105 (4.13) 104 (4.09) DIN RAIL 35 mm wide CN1 CN2 See Caution below A16 B16 14 (.55) FCN TYPE INPUT CONNECTOR 163 (6.42) FOR WALL MOUNT. 40 (1.57) 3 (.12) [6 (.24)] Caution: DO NOT APPLY EXCESSIVE FORCE onto the connector. The connector may be destroyed. http://www.m-system.co.jp/ R1M-A1 SPECIFICATIONS ES-5660 Rev.17 Page 5/6

SYSTEM CONFIGURATION EXAMPLES / Converter (model: R2K-1) TC/DC Inputs (model: R1M-GH) Contact Inputs (model: R1M-A1) Contact Outputs (model: R1M-D1) When the cable distance between the PC and the R1Ms is long, insert an / Converter for isolation. Specifications are subject to change without notice. http://www.m-system.co.jp/ R1M-A1 SPECIFICATIONS ES-5660 Rev.17 Page 6/6