Heavy-duty SmartRack enclosures hold up to 3000 lb (1363 kg) and practices, SmartRack enclosures make your job easier.

Similar documents
SmartRack Premium Rack Enclosures, Wall-Mount Rack Enclosures, Open Frame Racks, Cooling Solutions & Accessories

RACK SOLUTIONS. Rack Enclosures, Wall Mount Racks, Open Frame Racks and Accessories

VERTIV VR RACK. Selection Guide

QuickSpecs. HPE G2 Enterprise Series Racks. Overview

Vertiv VR Rack 1.0 GENERAL

COOLING SOLUTIONS. SmartRack Close-Coupled Cooling for IT Environments

QuickSpecs. HPE G2 Advanced Series Racks. Overview

APC Open Frame Rack Networking Solutions

15U Wall-Mount Server Rack Cabinet - 20 in. Deep - Hinged

S-SERIES 2 Superior Rack Solution for Data Center & Network Closets

QuickSpecs. HPE G2 Enterprise Series Racks. Overview

QuickSpecs. HP Rack G2 Series Overview

QuickSpecs. HP Rack G2 Series. Overview

D-Net CABINETS. D-Net cabinets are a versatile racking system suitable for housing

V800 Cabinet Solution

System Storage EXP3000 Rack Installation Instructions

F-SERIES Innovative Rack Solution

RE Series Rack from Eaton Product Presentation

MECHANICAL AND THERMAL CONSIDERATIONS FOR RACK DEPLOYMENT OF THE DELL POWEREDGE M-SERIES. One Dell Way Round Rock, Texas

or

Tripp Lite PDUs POWER DISTRIBUTION UNITS. Reliable rack power distribution for high-density IT environments. Introduction 2-3.

4-Post and Universal Telco Frame (UTF) Rack Mount Kit Installation Instructions

QuickSpecs. HP Rack G2 Series - top view

Specification Sheet: HT SERIES

16Hi HARDWARE INSTALLATION GUIDE

Rack Installation Instructions

QuickSpecs. HP Rack Series. Overview. HP Rack Series - 36U

QuickSpecs. HPE G2 Advanced Series Racks. HPE G2 Advanced Series Racks. Overview

Tripp Lite PDUs POWER DISTRIBUTION UNITS. Reliable rack power distribution for high-density IT environments. Introduction 2-3.

INTEGRATED SOLUTIONS. Tripp Lite Integrated Solutions. FREE Solution Integration Service

Knurr Miracel Server Rack

SYSTIMAX Rack and Cabinet Solution

Rack 111 Catalog. Designed and Built to Exceed Your Needs.

Hassle-free equipment installation

DATACOM CABINETS SOLUTION GUIDE

APC by Schneider Electric Solutions for Cisco Unified Computing System (UCS) Blade Applications

IBM. Rack Installation Instructions

Data Center Enclosures Best Practices. Maximize the Efficiency of the Enclosure within a Data Center

RittalXpress TS IT Enclosure Assemble-to-Order Program

HYPERFRAME CABINET & ENCLOSURE SOLUTIONS

S-Series Superior Rack Solution for Data Centre & Network Closets

Thermal management. Thermal management

RACK READY TO SAVE 10% ON ALL RACKS AND ACCESSORIES

EF-Series EuroFrame Gen 2 Cabinet System

Hassle-free equipment installation

Rack Installation Instructions

Rack Installation Instructions

Cabinet Solutions

Featured Products - RU Marking Standard on Hoffman brand

SECTION 5 -- EQUIPMENT LAYOUT & EQUIPMENT ENVIRONMENTS

Lenovo 42U 1200mm Deep Racks Product Guide

Eaton Heat Containment System (HCS) Installation Guide

1.866.TRY.GLCC WeRackYourWorld.com

Rackmount Shelves, Wallmount Shelves, Keyboard/Mouse Trays

Flexible platform with many features of the Elite.

Titan Media Cart. Installation and Operation Manual

Data sheet. Server Rack ( heavy duty rack cabinet ) W:600 = D:1000

Data Sheet FUJITSU PRIMECENTER M2 19-inch Racks

Rack Solutions RS-2. Free Standing Racks & Cabinets Wall Mount Racks, Cabinets, & Brackets Shelving Cable Management Accessories RS-5 RS-10 RS-12

APC APPLICATION NOTE #74

PI Server - 19 enclosures

Liebert XDA Air Flow Enhancer. User Manual

VersaPOD and V600. Cabinets. Section Contents. VersaPOD AND V600 CABINETS

Rack Installation Instructions

Titan Cable Management Catalog TCM3.0. IMS Engineered Products is ISO 9001 Certified. Designed and Manufactured in the USA

PowerChain Management solutions. Enclosure Solutions

Moving Containment Inside the Enclosure. Jeff Markle Great Lakes Case & Cabinet

CABINETS & CONTAINMENT SOLUTIONS GUIDE. designed to be better

Heat Containment System (HCS)

Rack Selection Guide for NetShelter SX

OZLINX Solutions Australia Pty Ltd 21 Ayton Street, Sunshine North, Melbourne VIC3020 Australia Ph: Fax:

V800. Cabinet V800 CABINETS

IT infrastructure Efficiency-boosting solutions. nextlevel. for data centre

Solutions Guide for Cisco UCS B and C Series Servers

707 Patching Frames. 505 Frames. 303 Frames. 404 & 202 Wallboxes. 505 Cabinets. 303 Cabinets. Cold Aisle Containment. 505 Server Cabinets

Floor Standing Rack Cabinet

Dell MD1280 Storage Enclosure Getting Started Guide

APC APPLICATION NOTE #146

Netfinity White Paper Netfinity Technology Center

EMEA. Product Catalog. RackLine. AT&T Rack & Enclosure LAN Cabling Products. AT&T Cabling Systems

New products spring 2018

Avoidable Mistakes that Compromise Cooling Performance in Data Centers and Network Rooms

VERAK IP. 19 Stand Alone Cabinet with IP65 Rating.

DIGITUS Server Cabinet Unique Series

V-Built Custom Preconfigured Solutions

UltraRack. Advanced Data Centre Enclosures SR SERIES

QuickSpecs HP Rack 5642

Rack Installation Guide

QuickSpecs. HP Rack Accessories. QuickSpecs. Retired

Power and Cooling for Ultra-High Density Racks and Blade Servers

FI Server Range. 600mm Wide 800mm Wide Door Options

SmartOnline V 3kVA 2.5kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 2U Rack/Tower, USB, DB9 Serial

Installation and Maintenance

E-Series Site Preparation Guide

The Most Advanced Racking Solutions Available!

System Storage DS3950 Quick Start Guide

CHASSIS INSTALLATION GUIDE

Compaq Ultra-Dense Server Deployment in Telecommunications (Telco) Racks

W DATA SHEET: FREE-STANDING DATA ENCLOSURES DS

RACKS AND CABLE MANAGEMENT

Transcription:

your rackmount equipment quickly and conveniently Organize, secure RCK SYSTEMS SmartRackTM Enclosures, Open rame Racks and ccessories Organize, secure and protect your rackmount equipment quickly and conveniently Organize, secure and protect your rackmount equipment quickly and conveniently Organize, secure and protect your rackmount equipment quickly and conveniently Organize, secure and protect your rackmount equipment quickly and conveniently Organize, secure and protect your rackmount equipment quickly and conveniently Organize, secure and protect your rackmount equipment quickly and conveniently Organize, secure and protect your rackmount equipment quickly and conveniently Organize, secure and protect your rackmount equipment quickly and conveniently Organize, secure and protect your rackmount equipment quickly and conveniently Organize, secure and protect your rackmount equipment quickly and conveniently Organize, secure and protect your rackmount Rack equipment Enclosures quickly and 2-5 conveniently Organize, secure and protect your rackmount Open rame equipment Racks quickly and 6 conveniently Organize, secure and protect Rack your ccessories rackmount equipment 7-10 quickly and conveniently Organize, secure and Cooling protect & your Cable rackmount equipment 8-9 quickly Management and conveniently Organize, secure and protect your rackmount equipment quickly and conveniently Organize, secure and protect your rackmount KVM Switches 11 equipment quickly and conveniently Organize, secure and protect your Power Distribution Units 12 rackmount equipment quickly and conveniently Organize, secure and protect

48U, 42U and 25U models, with or without side panels djustable mounting rails with easy-view depth index Toolless mounting slots for PDUs and vertical cable managers irflow exceeds server manufacturer requirements Built or Your Convenience deal or High-Density Data Centers With a design streamlined by years of customer feedback and T best Heavy-duty SmartRack enclosures hold up to 3000 lb (1363 kg) and practices, SmartRack enclosures make your job easier. Enclosures ship support advanced cooling, cable management, power distribution and fully assembled for rapid deployment and roll into place on heavy-duty monitoring features that keep critical servers and network equipment casters. Toolless mounting slots allow quick installation of PDUs and operating nonstop. Perforated doors permit massive front-to-rear vertical cable managers. djustable mounting rails include an easy-view airflow that exceeds server manufacturer requirements. SmartRack depth index to eliminate time-consuming measurements. Lightweight enclosures are fully compatible with hot-aisle / cold-aisle data modular doors and side panels provide safe, convenient service access. center configurations. irflow optimization accessories prevent air ntegrated baying tabs facilitate combining enclosures in rows for recirculation that compromises cooling efficiency. (See pages 8 and 9 standard data center baying applications. for more information about airflow optimization and cooling.) Specifications Standard Models SR25UB SR25UBEXP SR42UB SR42UBEXP SR48UB SR48UBEXP Rack Spaces 25U 25U 42U 42U 48U 48U Side Panels Yes (2) No Yes (4) No Yes (4) No T/E-310-D, EC 60297-3-100, DN 41494, P 20 Protection Rating, RoHS Standards Compliance 3000 lb (1363 kg) Stationary / 2250 lb (1022 kg) Rolling Load Capacity SmartRack Enclosures Rack Enclosures Mounting Depth djustable from 4 to 35.75 (102 to 908 mm) Optional SREXTENDER extension frame accessory (see page 3) increases maximum mounting depth to 43.75 (1111 mm) Square (ll models include 50 cage nuts, screws and washers for equipment mounting) Mounting Holes External Height 49 (1245 mm) 78.5 (1994 mm) External Depth Unit Weight 89 (2261 mm) 23.63 (600 mm) External Width 43 (1092 mm) - Optional SREXTENDER extension frame accessory (see page 3) increases external depth to 51 (1295 mm) 195 lb (88.6 kg) 149 lb (67.7 kg) 281 lb (127.7 kg) 203 lb (92.3 kg) 309 lb (140.5 kg) 211 lb (95.9 kg) Special pplication Enclosures Knockdown Models SR25UBKD SR25UBEXPKD SR42UBKD SR42UBEXPKD SR48UBKD SR48UBEXPKD Shock Pallet Models SR25UBSP1 SR25UBEXPSP1 SR42UBSP1 SR42UBEXPSP1 SR48UBSP1 SR48UBEXPSP1 Heavy-Duty Shock Pallet Models SR25UBSP2 SR25UBEXPSP2 SR42UBSP2 SR42UBEXPSP2 SR48UBSP2 SR48UBEXPSP2 Special application enclosures are identical to standard models, with the following exceptions: Knockdown models ship disassembled into several sections for easy transport and assembly in confined spaces. Shock pallet models include a reinforced shipping pallet and loading ramps, allowing pre-installation of equipment and reshipment to the final destination. The pallet supports up to 1250 lb (568 kg) during shipment, including the combined weight of the enclosure and all pre-installed equipment. Heavy-duty shock pallet models increase the pallet capacity to 2000 lb (909 kg). See page 4 for more information about shock pallet models. Smar track enclosures accommodate all standard 19 (482.6 mm) rackmount equipment, regardless of vendor 2 200802087 95-2918.indd 2 EMC2 1/8/2009 1:11:22 PM

res SmartRack Enclosures row With You pplications like hosting, colocation and server farms often experience rapid growth, requiring you to install deeper server chassis that pack more processing power in each rack enclosure. Replacing standard enclosures with deeper models is expensive and time-consuming, but Tripp Lite's rack enclosure extension frame (model SREXTENDER, sold separately) allows you to increase mounting depth by 8 (203 mm) without replacing enclosures or reinstalling existing equipment. You can add SREXTENDER to 48U, 42U or 25U SmartRack enclosures at any time, giving you room to grow without increasing your up-front investment. SREXTENDER allows SmartRack enclosures to house deeper equipment, avoiding expensive and timeconsuming enclosure replacement. The toolless mounting rails fit inside the extension frame, accommodating vertical cable managers and PDUs. Maximum mounting depth increases from 35.75" (908 mm) to 43.75" (1111 mm). SREXTENDER SmartRack Wall-Mounted Enclosure 12U with adjustable front and rear vertical rackmount rails Hinged cabinet swings away from wall bracket for easy equipment access (swing direction is reversible) Locking, reversible front door and locking, removable side panels ully assembled for quick installation deal or Space-Limited Network pplications Designed with provisions to integrate wall-mounting, easy equipment access and Specifications cable management, SmartRack wall-mounted enclosures are perfect for network Model orm actor equipment in T environments with limited floor space. Ventilated door and panels allow generous airflow to keep equipment operating safely. djustable Standards Compliance rack rails with square mounting holes accommodate up to 12U of standard 19 Load Capacity* Mounting Depth Mounting Holes Dimensions (H x W x D) Unit Weight (482.6 mm) rackmount equipment. sturdy hinge between the cabinet and the wall-mount bracket allows the cabinet to swing away from the wall for easy access to equipment and cabling. Top and bottom panels include convenient cutouts for cable routing. 200802087 95-2918.indd 3 SRW12US 12U wall-mounted enclosure T/E-310-D, EC 60297-3-100, DN 41494, P 20 Protection Rating, RoHS 200 lb (90 kg) Stationary / 200 lb (90 kg) Rolling djustable from 3 to 20.5 (76 to 521 mm) Square (ncludes 30 cage nuts, screws and washers) 25 x 23.63 x 21.6 (635 x 600 x 549 mm) 60 lb (27 kg) * ull wall-mount load capacity requires a mounting surface capable of bearing the full load. Rolling applications require optional SRCSTER accessory kit. 3 1/8/2009 1:11:27 PM

SmartRack Enclosure eatures 4 djustable Mounting Rails (4) with Easy-View Depth ndex ront and rear sets of rails adjust in ¼ (6.4 mm) increments. djustment is quick and convenient simply unscrew the rails, slide them to the desired depth and restore the Square Mounting Holes screws. The easy-view depth index Rack Unit Labeling ensures consistent rail placement Easy-View Depth ndex without requiring time-consuming measurements. Square mounting holes and included hardware (not shown) support standard 19 (482.6 mm) rackmount installation. B Toolless Mounting Rails (2) with Easy-View Depth ndex djustable rails include toolless mounting slots for quick installation of compatible PDUs and cable managers. The easy view depth index ensures consistent rail placement without requiring timeconsuming measurements. Mounting slots are arranged in an industry-standard pattern compatible with a wide variety of accessories. Each rail can accommodate two vertical PDUs or cable managers side-by-side (four per enclosure). C Roof Panel (Removable) Spring-loaded pins allow the roof panel to be removed and replaced in seconds. ncludes cable access channels and mounting slots for cable management accessories. D ront Door (Lockable/Removable/Reversible) The door is perforated for optimal airflow, which exceeds server manufacturer requirements. The door handle is reversible to preserve standard orientation if the door is reversed. Lockable, Reversible Handle E Split Rear Doors (Lockable/Removable) Split rear doors reduce clearance requirements for service access. The doors are perforated for optimal airflow, which exceeds server manufacturer requirements. Toolless Mounting Slot Toolless Mounting Button on Tripp Lite PDU Modular Side Panels (Lockable/Removable) Modular side panels are smaller and lighter, improving ease of installation and service. Standard 25U models include two side panels. Standard 42U and 48U models include four side panels. Side panels are not included with EXP models, which are intended for in-row baying and other applications that do not require side panels. Baying Tabs (2) Baying tabs allow enclosures to be combined securely in rows. Center-to-center width can be set at 600 mm or 24 to match standard data center floor tiles. H Heavy-Duty Casters and Levelers (4 each) Casters support a rolling load capacity of 2250 lb (1022 kg), allowing enclosures to be pre-configured and rolled to the final installation location. Levelers support a stationary load capacity of 3000 lb (1363 kg) and adjust to improve enclosure stability. Casters and levelers are removable. Convenient rounding System ll components are grounded to the enclosure frame, which includes multiple connections for facility ground. ront and rear doors include quick-release ground wires for convenient configuration. J Stabilizing Brackets (2) The included stabilizing brackets are used for shipment and can be attached at the bottom of the enclosure frame Mounted Outside (inside or outside) to improve stability after installation. The brackets can be bolted to the floor with the addition of the optional SRBOLTDOWN kit. or maximum enclosure stability, add the Mounted nside optional SRSTBLZE anti-tip stabilizing plate kit (see page 10). K Shock Pallet ( SP1 and SP2 Models Only) Caster Leveler 600 mm 24 Quick-Release round Wire Shock pallet models include a reinforced shipping pallet and loading ramps (see the inset photo on the next page), allowing pre-installation of equipment and reshipment to the final destination. The SP1 pallet supports up to 1250 lb (568 kg) during shipment, including the weight of the enclosure and all pre-installed equipment. The heavy-duty SP2 pallet supports up to 2000 lb (909 kg) during shipment.

C E D K H B H J Model SR42UB Shown 200802087 95-2918.indd 5 Shock Pallet and Loading Ramps (Optional) 5 1/8/2009 1:11:35 PM

O P E N R M E R C K S O P E N R M E R C K S O P E N R M E R C K S O P E N R M E r a c k S 6 SmartRack Open rame Racks Cost-Effective Equipment Organization Open frame racks provide economical organization for servers and network/telecom equipment. Sturdy aluminum (2-post) or steel (4-post) frames support loads up to 1000 lb (454 kg), but are light enough for one person to transport and install. Compact components facilitate assembly in confined spaces, such as wiring closets and Ds (intermediate distribution frames). Toolless mounting slots make installation of PDUs and vertical cable managers quick and convenient. Specifications OPEN RME RCKS o p e n f r a m e r a c k S o p e n f r a m e r a c K S 45U and 25U 2-post racks 45U and 13U 4-post racks Toolless mounting slots for PDUs and vertical cable managers Easy assembly and self-squaring design Model SR2POST SR2POST25 SR4POST SR4POST13 orm actor 2-post open frame rack 2-post open frame rack 4-post open frame rack 4-post open frame rack Rack Spaces 45U 25U 45U 13U Standards Compliance SmartRack enclosures accommodate all standard 19 (482.6 mm) rackmount equipment, regardless of vendor EMC 2 T/E-310-D, EC 60297-3-100, DN 41494, RoHS Stationary Load Capacity 800 lb (363 kg) 1000 lb (454 kg) Rolling Load Capacity N/ 1000 lb (454 kg) with optional SRCSTER accessory kit. Mounting Holes Round/Threaded (Mounting hardware included) Square (Mounting hardware included) Unit Height 84 (2134 mm) 49 (1245 mm) 84 (2134 mm) 28 (711 mm) Unit Width 20.3 (516 mm) 20.3 (516 mm) Unit Depth 4.8 (122 mm)* djustable from 34.6 to 46.1 (879 to 1171 mm) with base.** Unit Weight 29 lb (13.2 kg) 23 lb (10.5 kg) 58 lb (26.4 kg) 43 lb (19.5 kg) * 13.5 (343 mm) with base. ** Mounting depth is adjustable from 24 to 35.6 (610 to 904 mm).

R C K C C E S S O R E S R C K C C E S S O R E S R C K C C E S S O R E S R C K C C E S S O R E S RCK CCESSORES R C K C C E S S O R E S R C K C C E S S O R E S SmartRack ccessories lexible oundation for Data Centers SmartRack accessories adapt, enhance and expand SmartRack enclosures and open frame racks, addressing diverse applications and evolving T requirements throughout a data center s operational lifespan. Model Description irflow Optimization / Cooling ccessories (See pages 8 and 9 for more information.) Customize racks for individual applications and changing T requirements Optimize airflow and manage cables Toolless installation options available 2-Post Open rame Racks 4-Post Open rame Racks Compatibility Wall-Mount Enclosures SRN3U 3U an Panel 120V (3 high-performance fans; 210 CM; 5-15P plug.) SRXN3U 3U an Panel 230V (3 high-performance fans; 210 CM; C14 inlet.) SRNROO Roof-Mounted an Panel 120V (6 high-performance fans; 420 CM; 5-15P plug; toolless mounting.) SRXNROO Roof-Mounted an Panel 230V (6 high-performance fans; 420 CM; C14 inlet; toolless mounting.) SR1UPNEL10 1U Blanking Panel Kit (10 pieces; toolless mounting.) SR1UPNEL50 1U Blanking Panel Kit (50 pieces; toolless mounting.) SR1UBRUSH 1U Cable Pass-Through Panel with Brush Strip (Brush strip blocks unwanted airflow.) SRSKRT Rack Enclosure Skirt Kit (Brush strip blocks unwanted airflow at bottom.) SRSKET irflow Optimization Kit (Prevents recirculation of warm air through side gaps.) Cable Management ccessories (See pages 8 and 9 for more information.) SRCBLERN1U 1U Horizontal Cable Manager (lexible ring type.) SRCBLERN2U 2U Horizontal Cable Manager (lexible ring type.) SRCBLEDUCT1U 1U Horizontal Cable Manager (inger duct with cover.) SRCBLEDUCTVRT 6 (1.8 m) Vertical Cable Manager (Double finger duct with cover; toolless mounting.) SRCBLERNVRT 6 (1.8 m) Vertical Cable Manager (lexible ring type; toolless mounting.) SRCBLETRY Roof-Mounted Cable Trough (Provides cable routing and power/data cable segregation.) SRCBLETRYEXP Roof-Mounted Cable Trough Vertical Expansion (Requires SRCBLETRY.) SRCBLELDDER 10 x 1 (3 m x 0.3 m) Cable Ladder (ncludes 2 sections; requires SRCBLETRY.) Security / Monitoring ccessories (See page 10 for more information.) SRCOMBO Door Handles with Combination Lock (2-pack for front and rear doors; includes bypass key.) SRSWTCH Magnetic Door Switch Kit (2-pack for front and rear doors; requires ENVROSENSE.) ENVROSENSE Monitors temperature, humidity and contact-closure inputs. (Requires SNMPWEBCRD or switched PDU.) SNMPWEBCRD dds network interface to UPS systems for remote monitoring and control via SNMP, Web or telnet. Shelves (See page 10 for more information.) SRSHEL2P 2U Cantilever ixed Shelf (60 lb / 27 kg capacity; 18 / 457 mm depth.) SRSHEL4PHD Heavy-Duty ixed Shelf (250 lb / 113 kg capacity; 26 / 660 mm depth.) SRSHEL4PSLHD Heavy-Duty Sliding Shelf (100 lb / 45 kg capacity; 26 / 660 mm depth.) SRSHEL4PSL Standard Sliding Shelf (50 lb / 22 kg capacity; 26 / 660 mm depth.) SRSHEL4PKYBD Keyboard Shelf (25 lb / 11 kg capacity; 16 / 406 mm depth.) Mounting ccessories SRCENUTS Square Hole Hardware Kit (ncludes 50 cage nuts, screws and washers.) SRSCREWS Threaded Hole Hardware Kit (ncludes 50 #12-24 screws and washers.) SREXTENDER Rack Enclosure Extension rame (ncreases external depth of rack enclosures to 51 / 1295 mm; increases maximum mounting depth to 43.75 / 1111 mm. See page 3 for more information.) 2POSTRMKTWM Universal 2-Post Rackmount Kit (Supports 2U to 4U UPS systems and battery packs.) 4POSTRLKT 4-Post Rack Rail Kit (Supports rackmount cabinets up to 250 lb / 113 kg.) UPSHDERKT Heavy-Duty Mounting Ear Kit (Supports 2U cabinets up to 65 lb / 29 kg from front vertical rails in 4-post racks and enclosures. Not suitable for 2-post mounting.) Stability ccessories (See page 10 for more information.) SRBOLTDOWN Bolt-Down Kit (Secures included stabilizing brackets or optional stabilizing plates to facility floor.) SRSTBLZE nti-tip Stabilizing Plate Kit (Provides extra stability for standalone enclosures.) Mobility ccessory SRCSTER Heavy-Duty Rolling Caster Kit (ncludes 4 casters. Casters are included with 48/42/25U enclosures.) Standard Enclosures 7

SmartRack ccessories Cooling and Cable Management Cool Your Critical Equipment Crowded rack enclosures in high-density data centers generate lots of heat, requiring special measures to protect your equipment. SmartRack enclosures and accessories permit a wide range of convenient cooling solutions that support data center best practices. The first step is airflow optimization, including arranging enclosures in a hot-aisle / cold-aisle configuration. SmartRack enclosures and accessories fully support hot-aisle / cold-aisle configurations, essential for cost-effective data center cooling. The next step, often overlooked, is proper cable management. Cable management not only keeps your rack organized, it also prevents tangled cables from obstructing airflow and reducing cooling efficiency. or persistent hot spots, fan-assisted cooling actively moves warm air out of the enclosure and encourages intake of cooler air. H B C J D E irflow Optimization Hot-isle / Cold-isle Configuration hot-aisle / cold-aisle configuration increases cooling efficiency, reducing energy consumption by up to 20%.* Cool air is drawn from the cold aisle through the front of each enclosure and warm air is exhausted to the hot aisle and vented overhead. irflow optimization accessories prevent warm air from recirculating. * Source: TC Data Centers. Hot isle Cold isle Hot isle 8 Hot-isle / Cold-isle Configuration (Top View)

B Blanking Panels C 1U Brush Panel D Rack Enclosure Skirt Blanking panel kits include ten (SR1UPNEL10) or fifty (SR1UPNEL50) 1U panels that conveniently snap into place in empty rack spaces, preventing recirculation of warm air. The 1U brush panel (SR1UBRUSH) allows cables to pass through and keeps them organized in place. dense brush strip prevents recirculation of warm air. The rack enclosure skirt (SRSKRT) prevents recirculation of warm air through the bottom of the enclosure. nternal Cable Management External Cable Management E 1U & 2U Horizontal Cable Managers Ring-type (SRCBLERN1U / SRCBLERN2U) and duct-type (SRCBLEDUCT1U) cable managers are available. Vertical Cable Managers Vertical cable managers include mounting buttons for toolless zero-u installation in SmartRack enclosures and open frame racks. They can be used in a single 6 (1.8 m) section or two separate 3 (0.9 m) sections. Ringtype (SRCBLERNVRT) and duct-type (SRCBLEDUCTVRT) cable managers are available. an-ssisted Cooling H Cable Troughs The cable trough (SRCBLETRY) provides roof-mounted cable routing and power/data cable segregation for SmartRack enclosures. The cable trough expansion (SRCBLETRYEXP) provides vertical expansion with additional cable routing channels. Cable Ladder The cable ladder (SRCBLELDDER) provides roof-mounted cable routing for SmartRack enclosures, allowing cable bundles to span aisles or gaps within rows. The ladder includes 2 sections that combine to form a 10 (3 m) span. single section can span a smaller distance, or sections can be cut to size. (SRCBLELDDER requires SRCBLETRY.) Rackmount an Panels Rackmount fan panels (SRN3U / SRXN3U) include three fans in a 3U space. They remove warm air from enclosure hot spots, such as the top rear section. J an-equipped Roof Panels an-equipped roof panels (SRNROO/ SRXNROO) replace the standard roof panel. Six fans remove warm air from the top of the enclosure. SmartRack enclosures accommodate all standard 19 (482.6 mm) rackmount equipment, regardless of vendor EMC 2 9

SmartRack ccessories dditional Solutions Rack Shelves Power Distribution Units (PDUs) variety of rackmount shelves Tripp Lite s network-grade rackmount PDUs are highly reliable multiple are available, including fixed and outlet strips that distribute power from a UPS system, generator or sliding shelves with capacities up utility wall outlet to multiple devices. Tripp Lite makes basic, metered to 250 lb (113 kg). (See page 7 and switched PDUs with features to match any application. (See back for more information.) cover for more information.) Select models include toolless mounting SRSHEL4PHD buttons for convenient zero-u (vertical) installation in SmartRack enclosures and open frame racks. Simply insert the buttons into the toolless mounting slots and slide downward to lock into place. SRSHEL2P SRSHEL4PSL / SRSHEL4PSLHD nti-tip Stabilizing Plate Kit The anti-tip stabilizing plate kit (SRSTBLZE) provides an extra measure of stability for standalone enclosures. The kit includes front and rear stabilizing plates. dd the SRSTBLZE bolt-down kit (SRBOLTDOWN) to secure the stabilizing plates to the facility floor. Door Handle with Combination Lock Kit The door handle with combination lock kit (SRCOMBO) includes two replacement handles for the front and rear doors of SmartRack enclosures. The changeable three-digit combination lock can be bypassed with the included key, ensuring that administrators SRCOMBO always have access. Door Switch Kit and Environmental Sensor Module The door switch kit (SRSWTCH) includes two magnetic switches for the front and rear doors of SmartRack ENVROSENSE enclosures. The switches require connection to ENVROSENSE, which can also monitor temperature, humidity and contact-closure inputs for alarms and security systems. (ENVROSENSE SNMPWEBCRD must be connected to SNMPWEBCRD Toolless installation of a Tripp Lite PDU. Each toolless mounting or a Tripp Lite switched PDU.) rail can accommodate two PDUs or cable managers side-by-side (four total per enclosure or open frame rack). SRSWTCH Smar track enclosures accommodate all standard 19 (482.6 mm) rackmount equipment, regardless of vendor 10 200802087 95-2918.indd 10 EMC2 1/8/2009 1:11:59 PM

UN T S O W E R D S T R B U T ON UN T S Multi-outlet power distribution from UPS system, generator or wall outlet Digital load meters, network interface and automatic transfer switch available lexible mounting options, including toolless mounting lexible Mounting Options Network nterface Select Tripp Lite PDUs include toolless mounting buttons for quick and Switched PDUs include a network interface (RJ45 Ethernet) that easy zero-u (vertical) installation in SmartRack enclosures and open allows remote load monitoring, remote condition reporting and remote frame racks. Simply insert the toolless mounting buttons into the control of individual outlets via SNMP, Web or telnet. Switched PDUs toolless mounting slots and slide downward to lock into place. prevent downtime by providing load threshold notification and reduce ll PDUs include standard mounting brackets that support zero-u, service calls by rebooting locked devices remotely. 1U, 2U and/or surface mounting, depending on the model. utomatic Transfer Switch Digital Load Meters Select metered and switched PDUs include dual input power cords and ncluded with all metered and switched PDUs, a built-in automatic transfer switch (TS), providing the benefits of digital load meters display total current usage redundant input power sources to single-cord devices. f the primary in real time, allowing you to connect more power source fails or is taken off-line, the PDU automatically switches equipment safely without overloading the PDU. to the secondary power source. P O W E R D S T R B U T ON P Basic, Metered and Switched PDUs P O W E R D S T R B U T ON POWER DSTRBUTON UNTS P O W E R D S T R B U T ON UN T S PDU Comparison Chart eature Multiple Outlets (Up to 40 outlets per PDU) Toolless Mounting Buttons (ndustry-standard pattern) utomatic Transfer Switch (ncludes dual input power cords) Digital Load Meter (Displays current usage in real time) Basic PDU Metered PDU Switched PDU Select Models Select Models Select Models Select Models Select Models Network nterface (Remote monitoring and control via SNMP, Web or telnet) or Sales or Service Call or Visit: Power Pros, nc. 888-330-2538 www.powerprosinc.com Copyright 2009 Tripp Lite. ll trademarks are the sole property of their respective owners. Tripp Lite has a policy of continuous improvement. Specifications are subject to change without notice. Photos may differ slightly from final products. 1111 W. 35th Street, Chicago, L 60609 US 200802087 95-2918 200802087 95-2918.indd 12 1/8/2009 1:12:05 PM