PHOENIX CONTACT - 01/2010. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

Similar documents
PHOENIX CONTACT - 01/2007

PHOENIX CONTACT - 08/2009. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

STEP-PS/1AC/24DC/1.75

PHOENIX CONTACT - 07/2006

MINI-DC-UPS/12DC/4. Extract from the online catalog. Order No.:

PHOENIX CONTACT - 06/2007. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area.

MINI-PS AC/10-15DC/8

TRIO-DIODE/12-24DC/2X10/1X20

PHOENIX CONTACT - 05/2008. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

PHOENIX CONTACT - 05/2008. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

QUINT-BUFFER/24DC/24DC/40

UNO-PS/1AC/12DC/30W. Primary-switched power supply unit. Data sheet. 1 Description

QUINT-PS-3x AC/24DC/10

Power Supply, Primary Switch Mode, Narrow Design MINI-PS AC/24DC/1

Power Supply, Primary Switch Mode for Universal Use QUINT-PS AC/48DC/5

TRIO-PS/1AC/24DC/20. Extract from the online catalog. Order No.:

QUINT-PS AC/24DC/10

QUINT-DC-UPS/24DC/10. Extract from the online catalog. Order No.:

QUINT-PS/ 1AC/24DC/ 5

Uninterruptible Power Supply Unit for Universal Use QUINT-DC-UPS/24DC/40

QUINT-DC-UPS/24DC/10. Extract from the online catalog. Order No.:

QUINT-DC-UPS/24DC/40. Extract from the online catalog. Order No.:

QUINT-PS/1AC/24DC/10. Extract from the online catalog. Order No.:

onlinecomponents.com

Uninterruptible power supply - TRIO-UPS/1AC/24DC/

QUINT-PS/24DC/48DC/ 5

ASI QUINT /2.4 EFD

STEP-PS/1AC/24DC/2.5. Extract from the online catalog. Order No.: DIN rail power supply of 24 V DC/2.5 A, primary switched, single phase.

1-Phase Power Supply, Primary Switch Mode for Use in Potentially Explosive Areas QUINT-PS AC/24DC/5/EX

Power supply CP-C 24/5.0

Extract from the online catalog

QUINT-PS/ 1AC/24DC/20/CO

RTU500 series Data Sheet Power Supply CP-E 24/2.5

EMD-SL-LL-230. Electronic monitoring relay for level monitoring of conductive liquids. INTERFACE Data sheet _en_04. 1 Description.

Power supply CP-E 48/1.25 Primary switch mode power supply

Redundancy Module QUINT-DIODE/40

Power supply CP-E 24/0.75 Primary switch mode power supply

Easy Analog RNB130. Technical Information. Primary switched-mode power supply

Power supply CP-E 24/10.0 Primary switch mode power supply

QUINT-UPS/ 24DC/ 24DC/10

Power Supply HARTING pcon

Power Supply HARTING pcon

Redundancy unit CP-A RU

MINI MCR-SL-UI-2I(-SP)(-NC)

Rhino Redundancy Module PSM24-REM360S. Operating Instructions

Power supply CP-D 12/2.1 Primary switch mode power supply

EMD-FL-C-10. Electronic monitoring relay for overcurrent and undercurrent monitoring of direct and alternating current in single-phase networks

ETD-BL-1T-OFF-CC- 10S

DC/DC converters - QUINT-PS/24DC/24DC/

FL MC 2000E (SM40) LC

MINI MCR-SL-UI-REL(-SP)

MINI MCR-SL-PT100-UI(-SP)(-NC)

ETD-BL-1T-230(-PT) Multifunctional time relay with various functions and adjustable times. Data sheet. 1 Description

PHOENIX CONTACT Features

Industrial Power Supplies

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

Buffer module CP-B 24/20.0, ultra-capacitor based Accessory for power supplies (e.g. switch mode power supplies CP range)

MINI MCR-SL-PT100-UI-200

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

Contact protection relay

Industrial Power Supplies

MINI MCR-SL-UI-2I. Configurable signal duplicator. Data sheet. 1 Description

TSP-BCM48, TSP-BCM48A. Operating Instruction Manual. Page 1 of 13

Power supply CP-C 24/5.0

RAD-DI8-IFS. I/O extension module with 8 digital inputs or 2 pulse inputs. INTERFACE Data sheet. 1 Description

MINI MCR-SL-CVS NC

ILBIB24DO16-DSUB. Inline Block IO Module for INTERBUS With 16 Digital Outputs; Bus Connection via D-SUB Connectors

PI-EX-ME-2NAM/COC-24VDC

DC561, digital input/output module,

MINI MCR-SL-RPS-I-I. Repeater power supply, active. Data sheet. 1 Description

RAD-DOR4-IFS. I/O extension module, 4 digital relay outputs. INTERFACE Data sheet. 1 Description

DC562, digital input/output module,

IB ST 24 AO 4/EF. INTERBUS-ST analog output module, 4 outputs, 0-10 V, ±10 V, 0-20 ma, 4-20 ma. Data sheet. 1 Description

PI-EX-ME-2NAM/COC-120VAC

Electronic timer CT-ERD.12

MINI MCR-SL-PT100-UI. Active resistance thermometer measuring transducer. Data sheet. 1 Description

CliQ II DC-UPS Module 24V 40A / DRU-24V40ABN

DX561 Digital Input/Output Module

ILBPB24DO32. Inline Block IO Module for PROFIBUS With 32 Digital Outputs. AUTOMATIONWORX Data Sheet 6889_en_04. Description

PHOENIX CONTACT - 12/2007

PSR-MS60. Safety relay for emergency stop, safety door and light grid monitoring. Data sheet. 1 Description

PSR DC/ESP4/2X1/1X2

Rhino PSM Power Supplies. Operating Instructions

is then retained absolutely without interruption.

FL MC 2000T. Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections. Data sheet 3379_en_B

This data sheet is only valid in association with the IL SYS INST UM E user manual.

Electronic timer CT-AHD.22

PSR-PC50. SIL 3 coupling relay for safety-related switch on. Data sheet. 1 Description

20A DRR Module / 40A DRR Module

Chrome DIN Rail Power Supply 5V 7.5W 1 Phase (Class II & NEC Class 2) / DRC-5V10W1AZ

PSR-PS21. SIL coupling relay. Data sheet. 1 Description

DI561 Digital Input Module

24V 100W 1 Phase PMC-24V100W1AA

Electronic timer CT-ERS.12 ON-delayed with 1 c/o contact Data sheet

Electronic timer CT-EBD.12 Flasher starting with ON with 1 c/o (SPDT) contact

AI561 Analog Input Module

Switched-Mode Power Supplies. 5, 12, 18, 48 VDC Output

PSR-SCP- 24DC/URM4/4X1/2X2/B PSR-SPP- 24DC/URM4/4X1/2X2/B

Electronic timer CT-ERS.21

Transcription:

Uninterruptible power supply with integrated power supply unit INTERFACE Data sheet 104211_en_00 1 Description PHOENIX CONTACT - 01/2010 Features The MINI-DC-UPS provide an uninterruptible DC voltage both in case of AC power supply network and in the event of mains interferences. The wide-range input allows input voltages from 85 V AC to 264 V AC; 4 A is provided at the output with a regulated and adjustable output voltage from 10 V DC to 16 V DC. The rechargeable battery module supplies an output voltage from 13.8 V DC to 9.6 V DC in buffer mode. A 1.6 Ah or a 2.6 Ah rechargeable battery module is optionally used depending on the required buffer time. The buffer time varies depending on the load current. Easy assembly on the DIN rail or panel Quick startup with LED function monitoring Buffer time of 0.5 to 30 minutes or permanently settable Can be used worldwide in all industrial sectors due to a wide-range input and an international approval package Battery management for optimized, temperaturecompensated charging with simultaneous increase of battery life High operating safety due to long mains buffering under full load and high MTBF (> 500,000 h) DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area. The device contains dangerous live elements and high levels of stored energy. Never carry out work when the power is turned on. Make sure you always use the latest documentation. It can be downloaded from the product at www.phoenixcontact.net/catalog.

2 Table of contents 1 Description...1 Features...1 2 Table of contents...2 3 Ordering data...3 4 Technical data...3 5 Structure...7 6 Block diagram...8 7 Safety and warning notes...8 8 Installation...8 9 Installation position...9 10 Mounting on DIN rails...9 Assembly...9 Removing...9 11 Connection, network forms 100...240 V AC networks... 10 12 Input... 10 13 Output... 11 Signaling outputs...11 14 Signaling... 11 15 Rechargeable battery module... 12 16 Remote shutdown ("Remote")... 12 Remote shutdown inactive...12 Remote shutdown active...12 17 Function... 13 Setting the output voltage...13 Buffer time setting...13 104211_en_00 PHOENIX CONTACT 2

3 Ordering data Description Type Order No. Pcs. / Pkt. Uninterruptible power supply with integrated power supply unit, 4 A, in combination with MINI-BAT/12/DC 1.6 Ah or 2.6 Ah MINI-DC-UPS/12DC/4 2866598 1 The MINI-DC-UPS/12DC/4 is supplied without battery module. Please order a battery module separately (see accessories). Accessories Type Order No. Pcs. / Pkt. Rechargeable battery module, 12 V DC, 1.6 Ah, for use with DC-UPS/4A MINI-BAT/12DC/1.6AH 2866572 1 Rechargeable battery module, 12 V DC, 2,6 Ah, for use with DC-UPS/4A MINI-BAT/12DC/2.6AH 2866569 1 4 Technical data Input data Input nominal voltage range 100 V AC... 240 V AC AC input voltage range 85 V AC... 264 V AC DC input voltage range 100 V DC... 350 V DC (UL508: 100...250 V DC) Buffer period (Depending on the storage medium, e.g. 20 min / 4A) Current consumption Approx. 0.5 A / 0.65 A (for 230 V AC) Approx. 1.15 A / 1.35 A (for 120 V AC) Inrush current limitation < 34 A I 2 t < 1.1 A 2 s Power failure bypass (refer to the diagram) Typical response time 100 ms Power factor (cos phi) Approx. 0.5 Protective circuitry Varistor Input fuse, integrated 3.15 A (slow-blow, internal) Recommended backup fuse for mains protection 6 A (characteristic B) 10 A (characteristic B) 16 A (characteristic B) Output data Nominal output voltage 12 V DC (AC input voltage available: 10 to 16 V DC, AC input voltage not available: 13.8 to 9.6 V DC) Setting range of the output voltage 10 V DC... 16 V DC (AC input voltage available, AC input voltage not available: Output voltage depending on the battery voltage: 13.8 V DC... 9.6 V DC) Output current 4 A Derating From +60 C to 70 C: 2.5% per Kelvin Output current limit max. 7 A Charge current max. 1 A Max. capacitive load Unlimited Control deviation < 1 % (change in load, static 10%... 90%) Efficiency > 82 % Ascent time < 100 ms Residual ripple < 50 mv PP Peak switching voltages < 100 mv PP Connection in parallel No Surge protection against internal surge voltages Yes, < 35 V DC Resistance to reverse feed 35 V DC 104211_en_00 PHOENIX CONTACT 3

Power consumption Maximum power dissipation idling Power loss nominal load max. Power dissipation battery operation Output description Voltage Status display Battery charge Output description Voltage Status display Battery mode Output description Voltage Status display 3.8 W 10.5 W 2.9 W Relay output 12 V LED red / Malfunction/alarm: LED permanently lit Relay output 12 V LED yellow, flashing / Battery charge/battery is being charged: LED flashing Relay output 12 V Yellow LED / Battery mode/buffer mode: LED permanently lit General data Insulation voltage input/output 2 kv (routine test) 4 kv (type test) Degree of protection IP20 Class of protection II (in an enclosed control cabinet) MTBF > 500 000 h in acc. with IEC 61709 (SN 29500) Type of housing Polyamide PA, color: green Dimensions W / H / D (state of delivery) 67.5 mm / 99 mm / 115 mm Weight 0.45 kg Ambient conditions Ambient temperature (operation) -25 C... 70 C (> 60 C derating) Ambient temperature (storage/transport) -40 C... 80 C Max. permissible relative humidity (operation) 95 % (at 25 C, no condensation) Vibration (operation) < 15 Hz, amplitude ±2.5 mm in acc. with IEC 60068-2-6 15 Hz... 150 Hz, 2.3g, 90 min. Shock 30g in all directions in acc. with IEC 60068-2-27 Pollution degree in acc. with EN 50178 2 Climatic class 3K3 (in acc. with EN 60721) 104211_en_00 PHOENIX CONTACT 4

Standards Electrical Equipment for Machinery EN 60204 Safety transformers for power supply units EN 61558-2-17 Electrical safety (of information technology equipment) EN 60950/VDE 0805 (SELV) EN 61558-2-17 Electronic equipment for use in electrical power installations EN 50178/VDE 0160 (PELV) SELV EN 60950 (SELV) EN 60204 (PELV) Safe isolation DIN VDE 0100-410 DIN VDE 0106-1010 Protection against electric shock, basic requirements for safe isolation in DIN VDE 0106-101 electrical equipment Approvals UL approvals UL Listed UL 508 UL/C-UL Recognized UL 60950 Conformance with EMC guideline 2004/108/EC and for low-voltage guideline 2006/95/EC Noise immunity according to EN 61000-6-2 Electrostatic discharge EN 61000-4-2 Housing Level 3 Contact discharge 6 kv Discharge in air 8 kv Comments Criterion B Electromagnetic HF field EN 61000-4-3 Housing Level 3 Frequency range 80 MHz... 2 GHz Field intensity 10 V/m Comments Criterion A Fast transients (burst) EN 61000-4-4 Input 4 kv (level 4 - asymmetrical: conductor to ground) Output 2 kv (level 3 - asymmetrical: conductor to ground) Signal 1 kv (level 2 - asymmetrical: conductor to ground) Comments Criterion B Surge current loads (surge) EN 61000-4-5 Input 4 kv (level 4 - asymmetrical: conductor to ground) 2 kv (level 4 - symmetrical: conductor to conductor) Output Signal 2 kv (Level 3 - asymmetrical) 1 kv (Level 3 - symmetrical) 2 kv (Level 3 - asymmetrical) 1 kv (Level 3 - symmetrical) Comments Criterion B Conducted interference EN 61000-4-6 Input/Output/Signal Level 3 Frequency range 10 khz... 80 MHz Voltage 10 V Comments Criterion A 104211_en_00 PHOENIX CONTACT 5

Conformance with EMC guideline 2004/108/EC and for low-voltage guideline 2006/95/EC (Continued) Noise immunity according to EN 61000-6-2 Voltage dips EN 61000-4-11 Input (mains buffering > 20 ms) Comments Criterion B Emitted interference in acc. with EN 61000-6-3 Radio interference voltage in acc. with EN 55011 Emitted radio interference in acc. with EN 55011 EN 55011 (EN 55022) Class B, area of application: Industry and residential EN 55011 (EN 55022) Class B, area of application: Industry and residential 104211_en_00 PHOENIX CONTACT 6

5 Structure 1 7 12 1 2 0,5 3 5 30 10 20 15 IN AC 100-240 V L(+) N(-) t min max [ ] OUTDC12V 4A 10-16 V DC Power in OK Overload 2 Bat.- Mode Bat.- Charge R1 R2 Remote OFF ON MINI DC-UPS 4 5 6 Battery 8 3 9 10 11 1 AC input 2 DC output 3 Rechargeable battery connection 4 Active relay output: 5 Active relay output: Battery Mode 6 Active relay output: Battery Charge 7 Potentiometer 10 V DC... 16 V DC 8 Remote shutdown (R1, R2) 9 Red control lamp: 10 Yellow control lamp: Battery Mode/Battery Charge 11 Green control lamp: Power In OK/Overload 12 Buffer time setting 0.5 min... 30 min and permanently [mm 2 ] AWG [Nm] solid stranded Torque Input 0.2-2.5 0.2-2.5 24-12 0.5-0.6 Output 0.2-2.5 0.2-2.5 24-12 0.5-0.6 Signal 0.2-2.5 0.2-2.5 24-12 0.5-0.6 Input data Input nominal voltage range 100 V AC... 240 V AC AC input voltage range 85 V AC... 264 V AC DC input voltage range 100 V DC... 350 V DC (UL508: 100...250 V DC) Input fuse, integrated 3.15 A (slow-blow, internal) Recommended backup fuse for mains protection 6 A (characteristic B) 10 A (characteristic B) 16 A (characteristic B) Type of connection Pluggable COMBICON screw connections, Stripping length 8 mm Output data Nominal output voltage Setting range of the output voltage Output current Type of connection Stripping length 12 V DC (AC input voltage available: 10 to 16 V DC, AC input voltage not available: 13.8 to 9.6 V DC) 10 V DC... 16 V DC (AC input voltage available, AC input voltage not available: Output voltage depending on the battery voltage: 13.8 V DC... 9.6 V DC) 4 A Pluggable COMBICON screw connections, 8 mm 104211_en_00 PHOENIX CONTACT 7

6 Block diagram t...[min] Battery R1 R2 Remote On/Off L(+) N(-) PS Output DC 12V4A 7 Safety and warning notes DANGER The device contains dangerous live elements and high levels of stored energy. Never carry out work when the power is turned on. Depending on the ambient temperature and the load, the housing can become very hot! WARNING Before startup please ensure: The mains connection has been carried out by a competent person and protection against electric shock is guaranteed! The device can be disconnected outside the power supply unit in accordance with the regulations as in EN 60950 (e.g. through primary side line protection)! All feed lines are sufficiently protected and dimensioned! All output lines are dimensioned according to the maximum output current of the device or separately protected! Sufficient convection is guaranteed! CAUTION The power supply units are built-in devices. The device may only be installed and put into operation by qualified personnel. The corresponding national regulations must be observed. 8 Installation In order for the device to function in the manner intended. it is not necessary to observe any minimum spacing to other devices. The power supply unit can be snapped onto all DIN rails in acc. with EN 60715. They must be mounted horizontally (connecting terminal blocks top and bottom). 104211_en_00 PHOENIX CONTACT 8

t min 1 2 0,5 3 5 30 10 20 15 10-16 VDC Power in OK Overload MINI-DC-UPS/12DC/4 9 Installation position 67,5 110 OUTDC12V4A Bat.- Mode Bat.- Charge R1 R2 Remote Battery OFF ON 99 max [ ] MINI DC-UPS IN AC 100-240 V L(+) N(-) 115 10 Mounting on DIN rails Assembly To mount on a DIN rail, snap the device straight onto the DIN rail. Removing To remove from the DIN rail, press the base latch outward and pull the device off of the DIN rail. 104211_en_00 PHOENIX CONTACT 9

3 5 MINI-DC-UPS/12DC/4 11 Connection, network forms 100...240 V AC networks TN-S TN-C TT it L N PE L PEN L N L1 L2 L3 L N + - L N + L N - + - L N + - The 100...240 V AC connection is made using the L and N screw connections. The device can be connected to 1-phase AC networks or to two of the phase conductors of three-phase systems (TN, TT or IT networks in acc. with VDE 0100-300/IEC 60364-3) with nominal voltages of 100 V AC...240 V AC. For operation on two of the phase conductors of a three-phase system, an isolating facility for all poles must be provided. 12 Input CAUTION If an internal fuse is triggered, there is a device malfunction. In this case, the device must be inspected in the factory. OUT DC 12V 4A t min max[ ] 1 2 0,5 30 10 20 15 Bat.- Mode 10-16 V DC Bat.- Charge R1 R2 Remote Battery OFF ON IN AC 100-240 V L(+) N(-) Power in OK Overload MINI DC-UPS The 100... 240 V AC connection is established using the L and N screw connections. The device must be installed in acc. with the regulations as in EN 60950. It must be possible to disconnect the device using a suitable isolating facility outside the power supply. The primary side line protection, for example, is suitable. For device protection, there is an internal fuse. Additional device protection is not necessary. 104211_en_00 PHOENIX CONTACT 10

3 5 MINI-DC-UPS/12DC/4 13 Output OUT DC 12V 4A t min max[ ] 1 2 0,5 30 10 20 15 Bat.- Mode 10-16 V DC Bat.- Charge R1 R2 Remote Battery OFF ON IN AC 100-240 V L(+) N(-) Power in OK Overload MINI DC-UPS CAUTION Make sure that all output lines are dimensioned according to the maximum output current or are separately protected. The cables on the secondary side must have sufficiently large cross sections in order to keep the voltage drops on the lines as low as possible. Signaling outputs The connection is established through the "OUT DC 12 V, +, " screw connections. The set output voltage is 12 V DC at the time of delivery. The output voltage from 10 V DC to 16 V DC can be set on the potentiometer. Signal outputs are connected using "", "" and "" terminal blocks. Three control lamps and three active switching outputs are provided for function monitoring. 14 Signaling State Power In OK Battery mode/ Battery charge Supply voltage OK, rechargeable battery is being charged Supply voltage OK, rechargeable battery charged (normal mode) LED on LED is flashing; Battery mode output: 0 V, Battery charge: 12 V LED on LED off; Battery mode / Battery charge output: 0 V Buffer mode LED off LED on; Battery mode output: 12 V, Battery charge: 0 V Battery discharged, UBAT < 10.2 V DC Rechargeable battery test negative Buffer time over and remote shutdown activated LED off LED on; Battery mode / Battery charge output: 0 V LED on LED off; Battery mode / Battery charge output: 0 V LED off LED off; Battery mode / Battery charge output: 0 V LED off; output: 0 V LED off; output: 0 V LED off; output: 0 V LED on; output: 12 V LED on; output: 12 V LED off; output: 0 V 104211_en_00 PHOENIX CONTACT 11

3 5 MINI-DC-UPS/12DC/4 15 Rechargeable battery module Time [min] Time [h] 30 10 1 2 60 1 10 1 = 1,6Ah 2 = 2,6Ah 1 0 0,5 1 1,5 2 2,5 3 3,5 4 Current [A] The rechargeable battery module is connected to the power supply unit through the "Battery +" and the "Battery " terminal blocks. The fuse of the rechargeable battery module must be removed when installing or replacing the module. We recommend to use the following battery modules: 1. MINI-BAT 12DC/1.6Ah (Order No. 2866572) 2. MINI-BAT 12DC/2.6Ah (Order No. 2866569) The buffer mode might be terminated after the preset time or due to an external shutdown. If the device is to be switched off after a certain period, the time for it is set using the selector switch at the front of the device. The device can be switched on in the buffer mode again after reconnecting the power supply. 16 Remote shutdown ("Remote") The device has a remote shutdown with a UPS function for deliberate shutdown. Remote shutdown must be deactivated for the device to switch over to the buffer mode in the event of a supply voltage failure. OUT DC 12V 4A t min max[ ] 1 2 0,5 30 10 20 15 Bat.- Mode 10-16 V DC Bat.- Charge R1 R2 Remote Battery OFF ON IN AC 100-240 V L(+) N(-) Power in OK Overload MINI DC-UPS Remote shutdown inactive The "Remote shutdown R1" and "Remote shutdown R2" terminal points are short-circuited (e.g., with a plug-in bridge) OR 12 V DC is present at the "Remote shutdown R2" terminal point. The power supply unit switches over to the buffer mode in the event of a supply voltage failure. Remote shutdown active The "Remote shutdown R1" and "Remote shutdown R2" terminal points are not short-circuited (e.g., with a plug-in bridge) OR 0 V is present at the "Remote shutdown R2" terminal point. All LEDs are off. The power supply does not switch over to the buffer mode in the event of a supply voltage failure; the device switches off. The rechargeable battery module is charged when the supply voltage is reconnected, but the device remains switched off until the remote shutdown is activated. The connected consumers are fed as long as the supply voltage is available. 104211_en_00 PHOENIX CONTACT 12

3 5 MINI-DC-UPS/12DC/4 17 Function OUT DC 12V 4A t min max[ ] 1 2 0,5 30 10 20 15 Bat.- Mode 10-16 V DC Bat.- Charge R1 R2 Remote Battery OFF ON IN AC 100-240 V L(+) N(-) Power in OK Overload MINI DC-UPS Setting the output voltage In the normal mode, the output voltage of the device conforms to the setting on the potentiometer (10 V DC... 16 V DC). If the supply voltage fails, the buffer mode is activated without any interruption and the output voltage is supplied by the rechargeable battery module. The output voltage is now directly dependent on the battery voltage and is U BAT - 0.5 V. An alarm signal is triggered if the output voltage drops below 10.2 V in the buffer mode. If the output voltage drops to 9.6 V due to a completely discharged rechargeable battery module, the device switches off and remains switched off. The device switches on automatically only after reconnecting the power supply. The device is electronically protected against shortcircuits and no-load operation. Buffer time setting The buffer mode might be terminated after the preset time or due to an external shutdown. If the device is to be shut down after a specific time has elapsed, the time can be set via the selector switch on the front of the device. The device can be switched on in the buffer mode again after reconnecting the power supply. 104211_en_00 PHOENIX CONTACT GmbH & Co. KG 32823 Blomberg Germany Phone: +49-(0) 5235-3-00 13 PHOENIX CONTACT P.O.Box 4100 Harrisburg PA 17111-0100 USA Phone: +717-944-1300 www.phoenixcontact.com