User Manual. cmt-svr Startup Guide

Similar documents
User Manual. cmt-svr Startup Guide

256 MB RAM. 256 MB 32 bits RISC Cortex-A8 600MHz SD Card Slot. N/A USB Host. N/A USB Client

Machine TV Interface. mtv-100. Memory Processor. I/O Port RTC. Power. Specification. Certificate Software

User Manual. cmt-iv5 Startup Guide

User Manual. cmt-iv5 Startup Guide

3.1 Updating Web Package Updating OS... 16

Cloud Human Machine Interface SERIES

4-1. This chapter explains HMI settings.

4-1. This chapter explains HMI settings.

MT8050iE series. Installation Instruction (1) (2)

Performance, Design, and Versatility MT8000iE XE mtv ip Series

emt3000 series emt-3070a Installation Instruction 1.0 Installation and Startup Guide 2.0 Installation Instructions 2.1 Mounting Instructions

MT-600/8000 series. MT-607i MT-8070iH / MT-6070iH Installation Instruction Installation and Startup Guide. Where Used

MT-8000 series. MT-8056T/ MT-6056T Installation Instruction. 1.0 Installation and Startup Guide. 2.0 Installation Instructions

OnRISC. OnRISC Baltos ir 2110

JetBox 9300/9310 User Manual. Hardware

Performance, Design, and Versatility MT8000iE/XE mtv Series

Professionals in Human Machine Interface. Performance, Design, and Versatility MT8000iE/XE mtv Series

Arm-based DIN-rail industrial computers with 4 serial ports, 2 LAN ports, 8 DI/DO, and VGA. Features and Benefits. Certifications

Professionals in Human Machine Interface. We provide the most advanced and stable HMI product solutions.

We provide the most advanced and stable HMI product solutions

Feature and Benefits. Certifications

Performance, Design, and Versatility MT8000iE XE mtv ip Series

UR72 & UR75 Industrial Cellular Router

Performance, Design, and Versatility MT8000iE/XE mtv Series

We provide the most advanced and stable HMI product solutions

UR51 Industrial Cellular Router

Arm-based wireless-enabled DIN-rail industrial computers with 2 serial ports and 2 LAN ports. Features and Benefits.

F1000 User's Manual. (Version: V1.01)

Hardware manual. 1. Overview 2. Technical characteristics 3. Connections. ( Portal (../portal/portal.html)

Industrial Serial Device Server

MMI8000 Series. MMI8056, MMI8070, MMI8080, MMI8100, MMI8104, MMI8121 Installation Instructions

Serial to Ethernet Converter

Lantech LSC-1102B SERIAL TO TCPIP CONVERTER. User Manual

Matrix-710. Linux-Ready Cortex-A5 Industry IoT Gateway. Hardware Guide. Version: Nov.

exware Series Operating Instructions

COSMOS COLLECTOR X10 COSMOS X10 DATA COLLECTION AND REPORTING SYSTEM. User manual

POWERWISE INDAC SETUP MANUAL

Arm-based palm-sized industrial computers with 2 serial ports and 2 LAN ports. Features and Benefits. Certifications

Features and Benefits. Certifications

INDEX. Network Power Monitor NPM-R10-SNMP. Innovative Electronics for a Changing World. NPM-R10-SNMP Remote Network Power Monitor

MGate 5111 Quick Installation Guide

INDEX. Network Power Monitor R10 SNMP

USER MANUAL FOR GS100/GS1003G

cmt Quick Start Guide

MGate 5105-MB-EIP Quick Installation Guide

Innovative Electronics for a Changing World INDEX

Ethernet Interface Module

Short Instructions CG-S / IP-Router

MGate 5118 Quick Installation Guide

S SENECA. Installation Manual Z-TWS4. Z-PC Line. Web Multifunction Controller Straton / Linux

Control Panel CP600 CP651, CP651-WEB

mark150s mark150/485s DDC controllers Summary

Industrial Media Converters

Technical Manual Nova: Cabinet Security Management System (CSMS)

We provide the most advanced and stable HMI product solutions

Baltos ir Contact Online. More Pictures. Click on the thumbnails for the large picture

Newsletter. DOP-W Series HMI. Introduction. Product Features of DOP-W. N e w P r o d u c t L a u n c h. The Ultimate Work Made with Excellent Standard

Network Camera Quick Operation Guide

7 S-Series HMI W07FA3S-PCM1AC-PoE W07FA3S-PCM1-PoE. Quick Start Guide V1.0

Modbus TCP/RTU Gateway

icex-cmtm General specs and Installation guide

Control Panel CP600 CP635, CP635-B, CP635-WEB

BLUE LOG XM / XC. Quick Start Guide. Version

C-DIAS EtherNet/IP Slave CIP 022

PACSystems* RXi ICRXIBN0E000A and ICRXIBN0M000A

Quick Installation Guide

Note: the wiring of the dead-man buttons has been changed since October 2001.

DTM Distributed Transmitter Monitor

Intelligent 4 Port RS-422/485 to 2 Port Ethernet Serial Device Server with PoE

Innovative Electronics for a Changing World. NPM-R10 Remote Network Power Monitor. With optional relay board and GSM module INDEX

PBSCONTROL. AMS-R4000 Modular RTU. Remote Terminal Unit

Features: SF108-CR v1.1 SF108-CR 10-ports switch for 8 IP cameras in enclosure with recorder space

Features. Intel 45nm Atom Processor N270: 1.6 GHz

Specification Sheet For electronically commutated motors

MXPLC. Compact PLC process station. Summary. Application HVAC control systems, data acquisition, interfacing 3 rd party systems.

PWS500S Installation Guide

Installation and Configuration Quick Guide. R3000 Lite. Industrial Dual SIM Cellular VPN Router (1 Eth + 1 RS RS USB Host)

PIGEON RB100-CM3. Features. Applications

Web-enabled DAQ System

Hardware Reference. Web Application Gateway IGW/935. with esom/3517

Citrix CloudBridge CB User Manual

DT Desktop Series

Features: S98-B v1.0 S98-B 9-port switch with buffer power supply for 8 IP cameras

MODEL CIO-EN MODBUS/TCP, MODBUS/RTU I/O MODULE

Features: DSFB108 v1.1 DIN rail mounted switch 10-ports DSFB108 with buffer power supply for 8 IP cameras

TRP-C08. USB to RS232/422/485 Isolated Converter. User s Manual. Printed Sep.2014 Rev 1.4

DIN Rail RTU 540CMD01 Data sheet

NPort W2150A/W2250A Series Quick Installation Guide

SERIES. Professional In Human Machine Interface

HEC. General Operating, Maintenance and Installation Manual

Page Housing Plastic Metal Mounting DIN Rail or surface mount Panel or bracket mount Wattage Range 10W to 240W 7.5W to 240W 10W to 300W

VL BPC MINI. A configurable industrial computer platform Intel Atom Z510PT CMAT IPC Module Option [I28] AUTOMATION Data Sheet 2930_en_A.

Alekto 2. Contact Online. More Pictures. Klick on the thumbnails for the large picture

Modbus Server - M-Bus (EN ) Gateway for the integration of M-BUS meters with Modbus RTU and TCP based control systems.

Control Panel CP600-eCo CP604, CP604-B

DKG-210 UNIVERSAL INTERNET GATEWAY UNIT

Matrix-700 Linux-Ready Cortex-A5 Industry IoT Gateway Hardware Guide

PRELIMINARY. USB1 / USB2 USB host interface to read data via memory stick. Bus Out (system bus) For connection to a router

ICD105A 1008 page 1/ r001 ICD105A. Industrial RS-232 to RS-422/485 Converter

Transcription:

User Manual cmt-svr Startup Guide

Table of Contents Chapter 1 Overview... 1 1.1 Specification... 1 1.2 Dimensions... 2 1.3 Connector pin designations... 3 1.4 USB host port and SD card slot... 3 1.5 Ethernet port... 3 1.6 DIP switch... 3 1.7 LED indicator... 4 1.8 CR1225 battery... 4 1.9 Power connection... 4 1.10 How to update cmt-svr OS image... 4 1.11 Requirements... 5 Chapter 2 System Setting... 6 2.1 cmt-svr System Setting... 7 2.1.1 Information... 7 2.1.2 System Setting... 8 Chapter 3 How to create a cmt-svr project... 16 3.1 Create a new project... 16 3.2 Download project to cmt-svr... 17 Chapter 4 CloudHMI App... 18 4.1 Introduction of icons... 18 4.2 How to load project file to ipad... 19 4.3 How to switch between cmt-svr projects... 22

cmt-svr Startup Guide Chapter 1 Overview 1.1 Specification Cloud Human Machine Interface Features Two Gigabit Ethernet Ports Supports E-mail Compact Design and DIN-rail Mountable Built-in 256MB Flash Memory SD Card Slot for Extension of Storage One USB Host Port Fan-less Cooling System Supports MPI 187.5K Power Isolator Inside Display Project Screen Size 1024x748 or 768x1004 (Portrait mode) Memory Processor I/O Port RTC Power Specification Environment Certificate Software Storage(MB) 256 RAM (MB) 256 SD Card Slot ARM Cortex A8 600Mhz SD/SDHC USB Host USB 2.0 x 1 USB Client N/A Ethernet 10/100/1000M x 2 COM Port CAN Bus HDMI Input Power Power Consumption Power Isolation Voltage Resistance Isolation Resistance Vibration Endurance Enclosure Dimensions WxHxD Weight (kg) Mount Storage Temperature Operating Temperature Relative Humidity CE COM1 RS232,COM2 RS485 2W/4W,COM3 RS-485 2W N/A N/A Built-in (CR1225 3V lithium battery) 24±20%VDC 230 ma@24v Built In 500VAC (1 min) Exceed 50M at 500VDC 10 to 25Hz(X,Y,Z direction 2G 30 minutes) Plastic 130 x 115 x 27mm Approx. 0.18 kg 35mm Din rail mounting -20 ~ 70 C (-4 ~ 158 F) -20 ~ 55 C (-4 ~ 131 F) 10% ~ 90% RH (non-condensing) EN 55022: 2010 EN 55024: 2010 EN 61000-3-2: 2006+A2: 2009 EN 61000-3-3: 2008 AS/NZS CISPR 22: 2009+A1: 2010 EasyBuilder Pro V4.00.01 or later versions V1.00 1

125,00 [4,921] 129,73 [5,107] 1.2 Dimensions f Top View 27,00 [1,063] a b c d e Side View Front View 114,80 [4,520] Side View g h Bottom View a USB Host Port e Power Connector b Ethernet 2 Port f SD Card Slot c Ethernet 1 Port g DIP Switch d Com1 RS-232, Com2 RS-485 2W/4W, Com3 RS-485 2W h Reset Button V1.00 2

1.3 Connector pin designations PIN# Symbol COM1 RS-232 COM2 RS-485 2W 4W COM3 RS-485 1 Data+ Data+ 2 RxD Received Data 3 TxD Transmitted Data 4 Data- Data- 5 GND Signal Ground 6 RX+ Data+ RX+ 7 RX- Data- RX- 8 TX+ TX+ 9 TX- TX- 1.4 USB host port and SD card slot USB 2.0 full speed host interface supports barcode scanners and USB drive. While using external hard drive, use external power supply. Do not use USB port to charge external device. You may use SD card as an extension of storage 1.5 Ethernet port The unit has two 10/100/1000M Gigabit Ethernet ports. The LED indicators on the Ethernet port indicate: Orange LED: LAN link status Green LED: Active communication status 1.6 DIP switch Each HMI is equipped with a reset button and a set of DIP switches. When using the DIP switches to change modes, the corresponding functions will be triggered. When SW1 is turned ON and power the unit again, the IP setting is restored to default: Ethernet 1: DHCP Ethernet 2: 192.168.100.1 SW1 OFF SW2 OFF Mode Normal mode ON OFF Restore Ethernet IP settings OFF ON Boot loader mode ON ON Restore factory default Note: Reboot cmt-svr after adjusting DIP switches to start the corresponding mode. When restore factory default, the project file and history data stored in the unit are all cleared. V1.00 3

1.7 LED indicator LED indicators show the operation status of cmt-svr. Power (Orange) CPU (Green) Communication (Blue) Indicates power status. Indicates CPU status. Indicates communication status. It blinks during communication and may stay on when communication is good. 1.8 CR1225 battery The cmt-svr Series HMI requires a CR1225 coin type lithium battery to keep the RTC running. Battery type: CR1225 3V lithium battery How to check battery voltage: EasyBuilder Pro provides system register [LW-9008 (32bit-float): battery voltage] for checking current battery voltage. When battery voltage goes under 2.80, please replace battery. 1.9 Power connection Power: The unit can be powered by DC power only, voltage range: 24±20% Volts DC, compatible with most controller DC systems. The power conditioning circuitry inside the unit is accomplished by a switching power supply. The peak starting current can be as high as 500mA. Connection: To make a connection, strip about 3/8 of insulation off the end of the wire, turn the connector screw counterclockwise until the gap is wide open, insert the wire all the way in, and turn the screw clockwise until it is tight. Note: Connect positive DC line to the + terminal and the DC ground to the - terminal. 1.10 How to update cmt-svr OS image Copy the MTfirmware.bin file to SD card, insert the SD card to cmt-svr and flip DIP Switch 2 to ON. Restart cmt-svr and wait about 2 minutes for the system to update OS image. V1.00 4

1.11 Requirements 1. HMI model: cmt-svr 2. EasyBuilder Pro software version: V4.00.01 or later versions 3. Device: ipad Series 4. ios version: ios 6.0 or later versions 5. CloudHMI App: Download CloudHMI application from App Store. 6. Wireless router: The cmt-svr connects with other devices through wires. To connect ipad with cmt-svr, use a wireless router. 7. One ipad can operate three logged in cmt-svrs simultaneously. 8. One cmt-svr can connect with three ipads simultaneously. V1.00 5

Chapter 2 System Setting Connect cmt-svr via Ethernet cable, and configure system settings using the following two ways. Set in internet browser Open internet browser (IE, Chrome, or Firefox), and enter cmt-svr IP address (for example: 192.168.1.44/web_ihmi) to configure cmt-svr. Set on ipad Install and open CloudHMI App on ipad. Tap Search icon, select the cmt-svr and tap icon to configure cmt-svr. Note: The default IP address of Ethernet 1: DHCP, and Ethernet 2: 192.168.100.1 V1.00 6

2.1 cmt-svr System Setting 2.1.1 Information The following part introduces cmt-svr system information. V1.00 7

Icon Description Displays HMI name. Displays RTC date. Displays RTC time. 2.1.2 System Setting The following part introduces cmt-svr system setting. There are two modes, [System Setting] and [Update project to SVR]. [System Setting] controls all the settings while [Update project to SVR] controls limited items. For safety, confirm password before configuring. Also, before selecting [History], enter password. History data can be downloaded when password is confirmed. V1.00 8

IP Setting Set the IP address of Ethernet 1 and Ethernet 2. The default IP address of Ethernet 1 is DHCP. The default IP address of Ethernet 2 is 192.168.100.1. Date/Time Setting Set RTC date and time. V1.00 9

HMI Name Setting Enter a cmt-svr name to identify the unit when transferring data. This avoids remembering the IP address of each cmt-svr. Clean log Clear history data in cmt-svr. V1.00 10

Email contacts setting Set the E-mail contact addresses and group number. SMTP setting Configure E-mail server and relevant settings. V1.00 11

Restart EB Project Restart cmt-svr project and restore to initial state. Update project to SVR Upload the *.cxob project file to cmt-svr. V1.00 12

Download EB project Download the *.cxob project file from cmt-svr to PC. Download history Download history data from cmt-svr to PC. V1.00 13

Upload files Select E-mail account setting or User account setting and upload the file to cmt-svr. Password Setting Set the password of identities for login, and the password for transferring project file or history data. V1.00 14

User account setting Set user password and operable classes. V1.00 15

Chapter 3 How to create a cmt-svr project 3.1 Create a new project Step 1. Launch EasyBuilder Pro and select cmt-svr model. Step 2. Create the needed objects on editing screen. Step 3. Save the project and compile to *.cxob file. V1.00 16

3.2 Download project to cmt-svr The compiled *.cxob file can be downloaded by using EasyBuilder Pro via Ethernet. Or, in cmt-svr System Setting, tap [Update Project to SVR] to transfer project file from PC to cmt-svr. Open internet browser (IE, Chrome, Firefox), enter cmt-svr IP address (for example: 192.168.1.44/web_ihmi), tap System Setting, enter password, and then configure cmt-svr settings. V1.00 17

Chapter 4 CloudHMI App 4.1 Introduction of icons Icon Description After download CloudHMI from App Store, tap this icon to run CloudHMI App. After opening CloudHMI, tap the Start Button to configure the settings. Project tab lists the logged in cmt-svrs. Each ipad can control three cmt-svrs simultaneously. Search tab lists all the cmt-svrs on the same network. History tab lists the cmt-svrs that logged in before. System tab is used to adjust the volume or enable ipad Auto-Lock. If needed, switch language here. After changing the language, log in CloudHMI App again to update the setting. Tap this icon to make cmt-svr CPU LED (green) blink for finding the cmt-svr. Tap this icon to load cmt-svr project to ipad and operate. Tap this icon to configure cmt-svr system settings. In Search tab sort cmt-svrs according to IP address. In Search tab sort cmt-svrs according to HMI name. In History tab clear all the login records. Tap this icon to open Help. V1.00 18

4.2 How to load project file to ipad Step 1. Start CloudHMI App, tap Start Button as shown in the following figure. Step 2. Search all the cmt-svrs on the same network. V1.00 19

Step 3. Select the cmt-svr, tap and then enter password. Step 4. The ipad displays the project after the project is loaded V1.00 20

Tap Start Button to return to Search screen. To connect other cmt-svr, follow the preceding steps to search cmt-svr and load the project. The badge is displayed in the icons of the successfully connected cmt-svrs. Up to three cmt-svrs can log in ipad simultaneously, and for the rest connected cmt-svrs, the button is not available. V1.00 21

4.3 How to switch between cmt-svr projects When multiple cmt-svrs are connected, to switch between cmt-svr projects, select from Project tab. To delete cmt-svr project, tap. V1.00 22