PROTECTION RELAYS THE ULTRA LINE NUMERICAL MULTIFUNCTION INTELLIGENT DEVICE FOR PROTECTION, SUPERVISION, METERING AND CONTROL

Similar documents
For Transmission, Distribution and Machinery protection.

G - Base. Relays THREE PHASE + NEUTRAL CURRENT PROTECTION RELAY

Protection Relays PHASE & RESIDUAL OVERCURRENT

RE17LAMW on-delay timing relay - 1 s..100 h V AC/DC - solid state output

INTRODUCTION. The PL-50 MO and PM-250 families represent the. PM-250-H: Horizontal box. PM-250-V: Vertical box

RE17LAMW on-delay timing relay - 1 s..100 h V AC/ DC - solid state output

Relion 611 series. 611 series Type Test Certificate

Combined Overcurrent and Earth-fault Relay SPAJ 140 C. Product Guide

EM132 EM132. Main Features. Multi-functional 3-Phase Transducer. Energy Meter

Type VRLTC tap changer

RE17LCBM off-delay timing relay - control - 1 s..100 h V - solid state output

Feeder protection relay SPAA 121 C. Product Guide

MINER-S Station Controller. Substation Automation

Voltage regulator. SPAU 341 C 1MRS MBG Issued: July 1998 Status: Revised Version: C/ Data subject to change without notice

Earth-fault Relay SPAJ 110 C. Product Guide

INSTRUCTION MANUAL TRIP CIRCUIT SUPERVISION RELAY GKAD1

Switching Control Sentinel (SCS) TM For all ABB independent pole operated circuit breakers

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

EM133 EM133 TOU SMART ENERGY METER. Main Features. Multifunctional 3-Phase Smart Meter. Billing/TOU Energy Meter

ATV12HU22M3 variable speed drive ATV12-2.2kW - 3hp V - 3ph - with heat sink

MINER-S Station Controller

ATV12P075M3 variable speed drive ATV kW - 1hp V - 3ph - on base plate

RM22TG. Product data sheet Characteristics. three-phase control relay Vac, 2 C/O. Main. Complementary. Network number of phases

Residual overvoltage relay

Sensitive Earth-fault Relay SPAJ 111 C. Product Guide

Synchro-check relay. Application

Type MVTT 14 and MVTT 15: Static Digital Time delay relays

Bus Bar Protection Relay B-PRO 4000

RE22R2QGMR Star-Delta Timing Relay s 300h V AC/DC - 2C/O

extending the boundaries of technology evolution of proven technology FEATURES

RE22R2QTMR Star-Delta Timing Relay s 300h V AC/DC - 2C/O

IRI1-ES Sensitive Earth Fault Current Relay. Manual IRI1-ES (Revision A)

ATV12P037F1 variable speed drive ATV kW hp V - 1ph - on base plate

100% electricity. Automatic transfer switch controllers ATL series

Combined Overcurrent and Earth-fault Relay SPAJ 141 C. Product Guide

High Impedance Protection Relay SPAE010, SPAE011. Product Guide

Transformer Protection Relay

Arc protection relay. Features Three-phase overcurrent function. Application

RE22R1QMQ star-delta timing relay - 230VAC/440VAC - 1 C/O

ATV12H018M2 variable speed drive ATV kW hp V - 1ph

High impedance protection relay

Sensitive definite time or inverse time earth-fault stage for back-up residual earthfault

Circuit Breaker Sentinel (CBS) for SF 6. power circuit breakers

RE22R2AMR On-delay Timing Relay s 300h V AC/DC - 2C/O

RE22R2CMR Off-delay Timing Relay s 300h V AC/DC - 2C/O

RE22R2AMR On-delay Timing Relay s 300h V AC/DC - 2C/O

ATV310H075N4E variable speed drive ATV kw - 1 hp V - 3 phase

Scout-S Station Controller

ATV12H075M3 variable speed drive ATV kW - 1hp V - 3ph - with heat sink

ekorrps MULTIFUNCTIONAL PROTECTION UNIT CONFIGURATION AND GENERAL CHARACTERISTICS LIB

SIPROTEC easy 7SJ45 Numerical Overcurrent Protection Relay Powered by CTs

InteliPro. Protection Relay for Parallel Applications. Technical Specification

INGEPAC DA-CU. Control Unit. Data Sheet ZY8932IMA01E 31/03/2016

70 SERIES. Line monitoring relay

MRA1 Trip circuit supervision. Manual MRA1 (Revision A)

OHIO SEMITRONICS, INC. AC MULTIFUNCTION PROGRAMMABLE TRANSDUCERS & -1000L

MIN II. Complete numerical ground directional protection. Digital Energy Multilin. Protection and Control. Monitoring and Metering.

RE22R1QMQ star-delta timing relay - 230VAC/440VAC - 1 C/ O

ATV320U07M2C variable speed drive ATV kW V - 1 phase - compact

RM35JA32MR Current control relay 0.15A 15A, 2 C/O

ATV310HU30N4E variable speed drive ATV310-3 kw - 4 hp V - 3 phase

Data Sheet. Digital Multifunctional Power Meter with LCD Display and Optional Modules WPM D

RE11RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

Communication Gateway COM 610. Product Guide

DGSZV-EP DIGITAL GALVANIC LONGITUDINAL DIFFERENTIAL PROTECTION. Application field

RE22R2KMR Off-delay Timing Relay s 10min V AC/DC - 2C/O

High-Tech Range IRI1-ES- Sensitive Earth Fault Current Relay

Programmable Relay ZEN V2 Units

TM221CE40T controller M IO transistor PNP Ethernet

TM221CE24R controller M IO relay Ethernet

Feeder protection relay SPAA 341 C. Product Guide

Arc protection relay. Features Three-phase overcurrent function. Application

PowerLogic power-monitoring units. PM1000 series power meter. Technical data sheet

Energy Management Modular DC Energy analyzer Type VMU-E and VMU-X

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

TM200CE24T controller M IO transistor Source+ Ethernet

ATV320U04N4C variable speed drive ATV kW V - 3 phase - compact

ATV340D75N4E variable speed drive - 75kW- 400V - 3 phases - ATV340 Ethernet

iswitch imotor Compact QR

ATV930D22M3 variable speed drive - ATV930-22kW - 200/240V- with braking unit - IP21

TM3AI4 module TM3-4 analog inputs

Output Voltage* (nom.)(adjustable)

RE Product data sheet Characteristics. universal plug-in timing relay - flashing s..60 mn V AC - 2 OC. Main.

SIMOCODE 3UF Motor Management and Control Devices

TM3TI4 module TM3-4 inputs temperature

PMC 530 Series Advanced Multifunction Meter

Voltage Transducer UMT516 / MT516

Thermistor motor protection relays CM-MSS.12 and CM-MSS.13

RM22LA32MR Level control relay RM22-L V AC/DC - 2 C/O

TM221M16R controller M IO relay

RE7RB13MW adjustable off-delay timing relay s V AC DC - 2OC

BFM-II BFM-II BRANCH FEEDER MONITOR. Highlights

TM221ME32TK controller M IO transistor PNP Ethernet

Thermistor motor protection relays CM-MSS.12 and CM-MSS.13

Tap Position Indicator - PI

RE8TA31BU industrial timing relay s - type A - 24 V AC/DC, V AC - 1 C/O

TeSys protection components

RTU511. Binary Output 23BO62. Characteristics. Application. Data Sheet Binary Output 23BO62. The binary output is made via relay contacts.

TM5C12D6T6L compact I/O expansion block TM5-24 I/0-12 DI - 6 DO transistor - 4 AI - 2 AO

Binary output and supervision 520CSD01 Data sheet

Transcription:

MICROPROCESSOR PROTECTION RELAYS THE ULTRA LINE NUMERICAL MULTIFUNCTION INTELLIGENT DEVICE FOR PROTECTION, SUPERVISION, METERING AND CONTROL

MICROELETTRICA SCIENTIFICA MANUFACTURES A COMPLETE RANGE OF DIGITAL PROTECTION RELAYS DIVIDED IN DIFFERENT LINES FOR SPECIFIC APPLICATIONS. Among these lines the ULTRA-M is the top one designed to meet the most demanding specifications for any application in Trasmission,Distribution and Electric Machinery protection The ULTRA is a very powerful hardware platform on which different firmware programs can be downloaded to accomplish the combination of a number of functions needed for different applications (in protection and management). - Conformance to all IEC 60255, IEC 61000, ANSI-IEEE C37, CE Directive. - Modular fully draw-out execution in individual flush mounting enclosure IP44 (on request IP54) or in 19"-3U chassis for standard Rack panel. - Large graphical LCD display with mimic indication of the C/B status. - User friendly four-buttons keyboard for complete local management. - On-Off Breaker Control push buttons on front face. - RS232 port for local P.C. interface with Modbus-protocol (communication speed: 9600 to 57600bps). - RS485 communication port for connection to Supervision System with Double Communication Protocol Modbus RTU and IEC870-5-103 (communication speed: 9600 to 38400bps). - Optional ethernet communication protocol. - Field-bus (CANBUS) port for control of additional periferic units. - Multivoltage autoranging fully insulated power supply. - Four transformer insulated current inputs (selectable 1-5A). - Four transformer insulated voltage inputs (programmable 50 150V). - Fully programmable settings and Time Current Curves. - Six internal output relays, expandable by additional Output Modules, all user programmable. - Four internal, self powered, optoisolated digital Inputs expandable by additional digital Inputs Modules, all user programmable. - Self-contained Trip Circuit Supervision (F74). - Real time and recorded measurement of all electrical system quantities. - Time tagging with synchronization from serial communication. - Trip and event recording with time tag and input values. - Programmable oscillography wave forms of all inputs. - Comprehensive continuous self-diagnostic. NUMERICAL MULTIFUNCTION IN- TELLIGENT DEVICE FOR PROTECTION, SUPERVISION, METERING AND CONTROL

ELECTRICAL CHARACTERISTICS MAIN MODELS OF THE LINE SERIAL COMMUNICATION The ULTRA line is supported by an advanced communication software with very comprehensive functionalities and yet remaining extraordinarily user friendly and versatile. Microelettrica Scientifica has developed and realized MSCOM II, a communication software for Windows systems available in two versions: PROFESSIONAL (MSCOM II PRO) it is the full version software which allows to: - Simultaneously communicate on serial ports with up to 250 Microelettrica Scientifica relays. - On-line Firmware updating. - Save on disk data coming from relays. - Program or modify settings and configurations. - Prepare off-line relay settings files and directly upload relay's memory. - Print data tables and oscillographic wave form recordings. - Periodically poll the relays and save any data directly in the hard disk or send data to a printer. - Access the relays over TCP/IP protocol modem. - Access the relais through modem. Rated Current: In = 1 or 5A; On = 1 or 5A Current Overload: 80In x 1sec; 4In continuous Burden on current inputs: phase: 0.01VA@1A, - 0.2VA@5A, earth: 0.01VA@1A, - 0.2VA@5A Rated Voltage Un = 100-125Vac Voltage overload: 2 Un continuous Burden on voltage inputs: 0.1VA phase@ Un Averange power supply consumption: <10VA Output Relays: Rating 5A - 250V A.C. resistive switching 1100W, 380 Vac Make=30A peak 0.5 sec Break: 0.3A, 110Vdc. L/R = 40msec Operation ambient temperature: -10 C / +55 C Storage temperature: -25 C / +70 C Reference standards: IEC60255, IEC61000, IEEE C37 CE: EN50081-2, EN50082-2 EN50263, ENV50204 Dielectric test voltage: IEC60255-5 2kV, 1 min. Impulse test voltage: IEC60255-5 5kV(cm),2kV(dm)-1.2/50 us HF disturbance test (1 MHz burst test): IEC60255-22-1 class 3 Electrostatic discharge test: IEC61000-4-2 level 4 Conducted disturbance immunity test: IEC61000-4-6 level 3 Radiated electromagnetic LITE (MSCOM II LITE) this version is freeware and supports all the microprocessor relays manufactured by Microelettrica Scientifica.It allows to: - Communicate only with one relay at a time. - On-line Firmware updating. - Save on disk data coming from relay. - Print data tables and oscillographic wave form recordings. MS-TD PRO 32 is the customer designed multi-protocol software used by Microelettrica Scientifica to implement SCADA (Supervision Control and Data Acquisition) systems based on data and measurements coming from the Protection, Metering and Control devices. FMR Feeder Manager Relay MMR Motor Manager Relay GMR Generator Manager Relay DTMR Transformer Differential Relay DTMR-G Generator Differential Relay U-MLEs DC Feeder Protection Relay For more detailed information about the characteristics of the relays, please refer to each single catalogue. field immunity test: IEC61000-4-3 level 3 Electrical fast transient/burst: IEC61000-4-4 level 4 Surge immunity test IEC61000-4-5 level 4 Oscillatory waves (ring waves): IEC61000-4-12 level 4 Power frequency magnetic test: IEC61000-4-8 level 5 Pulse magnetic field: IEC61000-4-9 level 5 Damped oscillatory magnetic field: IEC61000-4-10 level 5 Voltage interruptions: IEC61000-4-11 200ms HF induced voltage: IEC61000-4-1-A.2.6 level 4 Resistance to vibrations and shocks: IEC60255-21-1 and 21-2

DCS RS485 ULTRA-M CANBUS EX/IO EXPANSION MODULES ULTRA-S RS485 ULTRA 19 RS485

PROTECTION DEGREE IP44 (IP54 ON REQUEST) FLUSH MOUNTING OVERALL DIMENSION 19 Panel can house up to 8 modules 51 mm wide. Each ULTRA relay is 2 module wide (102 mm) ULTRA - S EXECUTION has the dimensions corresponding to 3 modules (n=3) ULTRA RELAY WIRING DIAGRAM MODULAR 3U PANEL OVERALL DIMENSION

Founded in 1953, Microelettrica Scientifica has developed a wide range of products, divided into three main lines: Electronic Relays: For Transmission, Distribution and Machinery protection. A-Line Electronic analogic. M-Line Digital Draw-out LED Display. N-DIN-Line Digital DinRail mounting for MCC/PCC. MC-Line Digital Compact Draw-out LCD Display. ULTRA-Line Digital Draw-out Graphical LCD Display. Contactors A.C./D.C. low and medium voltage Contactors and Disconnetting Switches. N-Series: Bar Contactors ranging up to 6000A - 1000V A.C./D.C. LTH-Series: Specially designed for traction up to 1250A - 1500V D.C. LTHH-Series: Specially designed for traction up to 1750A - 4000V D.C. LTHH-Series: Disconnecting Switches elettromagnetic, pneumatic or motor driven ranging up to 1750A - 4000V D.C. Resistors: For any voltage and power rating, neutral or forced air cooled. Jul 2009 - SF11 - Rev.1 www.bonobodesign.it For "Industrial" application: load, regulation, earthing,filter. For "Railway" application: braking, filter. Microelettrica Scientifica S.p.A. via Alberelle 56/58 20089 Rozzano, Milano (Italy) Tel. +3902575731 - Fax +390257510940 http://www.microelettrica.com sales.relays@microelettrica.com The performances and the characteristics reported in this catalogue are not binding and can modified at any moment without notice