MULTI-LINE 2 DESCRIPTION OF OPTIONS

Similar documents
Advanced Graphical Interface, AGI 100

Option X4 Additional Operator Panel AOP-2 Description of option Functional description

Getting started - USW 3.x Software download from internet Software installation Device setup Data backup

APPLICATION NOTES Translations

Inverter Interface Interface examples Wiring examples Communication topology

Option H10, Multi-line 2 unit with USB service port. To be used when the multi-line 2 unit service port is USB type

Compact Genset Controller, CGC 400 What's in the delivery? The first steps Push-buttons and LEDs

APPLICATION NOTES H-coupling

Option P1 Event and alarm printer Description of option Functional description Parameter list

APPLICATION NOTES DELOMATIC 4, DM-4 GAS/HYDRO

DEIF A/S. Description of options. Option C2, Generator add-on protection package Automatic Gen-set Controller. Description of option

DEIF A/S. Description of options. Option C1 Generator add-on protection package Multi-line 2 version 2. Description of options. Functional description

AGC 200 Advanced Gen-set Controller What s in the delivery? Getting started The first steps Using the AGC 200

CODESYS v. 2.3, Ethernet driver for AGI 3xx Use the CODESYS Ethernet driver in the AGI Creator Set up the CODESYS for use with the AGI Creator

DEIF A/S. Description of options. Option P1, Event and alarm printer Automatic Gen-set Controller. Description of option. Functional description

QUICK START GUIDE Generator Paralleling Controller, GPC-3 Generator Protection Unit, GPU-3/GPU-3 Hydro Paralleling and Protection Unit, PPU-3

Multi-instrument Communication, MIC-2 MKII DIN Quick Start Guide

Automatic Genset Controller, AGC-3 What's in the delivery Getting started The first steps Using the AGC

Automatic Genset Controller, AGC-4 What s in the delivery? Getting started The first steps Using the AGC

Multi-instrument Communication, MIC-2 MKII DIN Quick Start Guide

Automatic Genset Controller, AGC-4 What s in the delivery? Getting started The first steps Using the AGC

MULTI-LINE 2 APPLICATION NOTES. Converting PPU-2 to PPU-3 Parameter conversion Wiring Options I/O list. Document no.: A SW version:

Genset control and protection with safety system

MULTI-LINE 2 DESCRIPTION OF OPTIONS. Option N Modbus TCP/IP SMS/ alarms NTP time synchronisation. Document no.: C SW version:

Option H8.x and H12.x External I/O modules Description of option Functional description

MULTI-LINE 2 APPLICATION NOTES

MULTI-LINE 2 DESCRIPTION OF OPTIONS. Option N Modbus TCP/IP SMS/ alarms NTP time synchronisation. Document no.: D SW version:

DEIF A/S. Description of options. Option H4 Serial comm. CAT CCM communication Multi-line 2 version 2. Description of option Functional description

OPERATOR'S MANUAL Generator Paralleling Controller, GPC-3 - Generator Protection Unit, GPU-3/GPU-3 Hydro - Paralleling and Protection Unit, PPU-3

EAP 300 REMOTE ANNUNCIATOR INSTALLATION MANUAL. r.0454a

DEIF A/S. Description of options. Option A and B, Loss of mains protection package Automatic Gen-set controller. Description of options

APPLICATION NOTES. Advanced Graphical Interface - AGI Internal PLC (CODESYS V3) SHENDONG

for Energy and Power meters AEM and APM with Modbus interface

Quick Start Guide. NP290W Turbo Wireless HomePlug

Option H3 Serial communication Profibus DP

QUICK START GUIDE Paralleling and Protection Unit PPU 300

Operating instructions IO-Link master CabinetLine AL19xx

Lab IP Addresses and Network Communication

TeSys Programmer. Firmware Update Utility for LTMR & LTMCU User Manual. January 2017

QUICK START GUIDE Generator Protection Unit GPU 300

INSTALLATION INSTRUCTIONS

QUICK START GUIDE Paralleling and Protection Unit PPU 300

Option M2 Configurable engine control cards Multi-line 2 version B SW version 2.4X.X

SEI DC-UPS Power Management Package Users Manual

Setting up securityglobal FW Rulesets SIMATIC NET. Industrial Ethernet Security Setting up security. Preface. Firewall in standard mode

MSD-SRF2XM Multi-port RS-232 to Ethernet Data Gateway User Manual

Ethernet Module MGC-PRO MicroDrive

Power Xpert Meter 2000 Gateway Card Kit

Power Xpert Meter 2000 Gateway Card Kit

Power Xpert Meter 2000 Gateway Card Kit

WiFi Setup Guide. Overview. Before you start

MultiModem rcell. Intelligent Wireless Router. Quick Start Guide

Basic Gen-set Controller G (UK) SW version 2.1X.X. Terminal strip overview

Networking a Digital Video Recorder

Magnitude TM Chiller Unit Controller BACnet Communication Module (MS/TP, IP, Ethernet)

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

Compact Genset Controller, CGC 200 Mounting Terminals and wiring Commissioning, using the Utility Software and/or the front panel

TIME SERVER NETSILON. Quick start.

Insight Installation of FX30 Data Acquisition Unit (DAU) Login to Insight Setup Insight with your equipment in the cloud Related system information

Active Load Balancing via Modbus TCP/IP

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

MULTI-LINE 2 APPLICATION NOTES. Converting PPM-2 to PPM-3 Parameter conversion Wiring Options I/O list Modbus. Document no.: A SW version:

Connecting the DI-804V Broadband Router to your network

Siemens Spares. Setting up security in STEP 7. Professional SIMATIC NET. Industrial Ethernet Security Setting up security in STEP 7 Professional

EtherNet/IP Communications Module

Getting Started - Startdrive. Startdrive SINAMICS. Introduction 1. Connecting the drive unit to the PC. Creating a project 3

ACC1000 QUICK NETWORKING GUIDE

MultiModem rcell Intelligent Wireless Router. Quick Start Guide

Description of options. user s manual. DEIF A/S Frisenborgvej 33 DK-7800 Skive Tel.: Fax:

QUICK START GUIDE MODEL 195Ep

Application Note (Revision A, 6/2002) Original Instructions. 723PLUS/DSLC Network Binding Procedure. LonMaker for DOS

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

TABLE OF CONTENTS COPYRIGHT INTRODUCTION...3 PRODUCT OVERVIEW...3 COMPONENTS AND FEATURES...3 HARDWARE INSTALLATION

SB72EX User's Manual

DP-301P+ D-Link Fast Ethernet Print Server

Product Family: Networking Hardware Number: AN-NH-012

TROUBLESHOOTING COMMUNICATION PROBLEMS BETWEEN A TYPE 3 DECODER AND THE MYLAPS PRACTICE WEBSITE

Canlan INSTALLATION MANUAL

APPLICATION NOTES. HEADING INDICATOR SYSTEMS using XDi-N indicators. Document no.: A

OPERATION MANUAL. MV-410HS Web Browser. Version Rev.2

DATA SHEET LAN Server For Energy and Power meters AEM and APM with Modbus interface

MOD-MUX MODBUS TCP I/O PRODUCTS

SIMATIC NET. Industrial Ethernet Security SCALANCE S615 Getting Started. Preface. Connecting SCALANCE S615 to the WAN 1

MicroTech II McQuay Maverick II Rooftop Unit Controller BACnet Communication Module, Ethernet or IP

Ethernet Smart Cable

Version 1.0c May 6, 2010 ATK3

1 P a g e. Local Application software by MidNite Solar

iconnect625w Copyright Disclaimer Enabling Basic Wireless Security

APC100. User Manual.

STS Web card for Upsilon/Epsilon STS (66073) STS Web card User Manual

MODEL CIO-EN MODBUS/TCP, MODBUS/RTU I/O MODULE

Use a hardwired Ethernet to RS232 Converter [Moxa N Port Express ]

Hardware Installation Guide Installation (x3350)

App Tariff Switch Functional description

User Manual Anybus Serial Server

Monitor - 15-Inch LCD - Replacement

Enabling RUGID RTUs to Communicate Over Ethernet

Getting Started with Modbus TCP/IP for AC Tech Drives

P-Bus Gateway Firmware

Section 4: Installing the ECC (Epilog Control Center)

Transcription:

MULTI-LINE 2 DESCRIPTION OF OPTIONS Option N Modbus TCP/IP Document no.: 4189340612D

This description of options covers the following products: AGC 200 series APU 200 series Utility Software SW version 3.53.1 or later SW version 3.53.x or later SW version 3.20.0 or later DEIF A/S Page 2 of 11

Table of contents 1. WARNINGS AND LEGAL INFORMATION... 4 LEGAL INFORMATION AND RESPONSIBILITY... 4 ELECTROSTATIC DISCHARGE AWARENESS... 4 SAFETY ISSUES... 4 PROGRAMMING... 4 NOTES... 4 2. DESCRIPTION OF OPTION... 5 HARDWARE... 5 3. NETWORK CONFIGURATION OF THE OPTION N... 6 OPTION N SETUP... 7 CHANGING THE AGC 200 IP ADDRESS... 8 4. TCP/IP MODBUS COMMUNICATION... 10 5. TCP/IP MODBUS DATA TABLES... 11 DEIF A/S Page 3 of 11

1. Warnings and legal information This chapter includes important information about general legal issues relevant in the handling of DEIF products. Furthermore, some overall safety precautions will be introduced and recommended. Finally, the highlighted notes, which will be used throughout this document, are presented. Legal information and responsibility DEIF takes no responsibility for installation or operation of the generator set. If there is any doubt about how to install or operate the engine/generator controlled by the Multi-line 2 unit, the company responsible for the installation or the operation of the set must be contacted. The Multi-line unit is not to be opened by unauthorised personnel. If opened anyway, the warranty will be lost. Electrostatic discharge awareness Sufficient care must be taken to protect the terminals against static discharges during the installation. Once the unit is installed and connected, these precautions are no longer necessary. Safety issues Installing the Multi-line 2 unit may imply work with dangerous currents and voltages. Therefore, the installation should only be carried out by authorised personnel who understand the risks involved in working with live electrical equipment. Programming The Multi-line 2 unit is delivered from factory with factory settings. These are based on an average value and do not necessarily represent values matching the engine/generator set in question. Precautions must be taken to check this before running the engine/generator set. Notes Throughout this document a number of notes will be presented. To ensure that these are noticed, they will be highlighted in order to separate them from the general text. The notes provide general information which will be helpful for the reader to bear in mind. DEIF A/S Page 4 of 11

2. Description of option Hardware The option N is an Ethernet hardware option offering a number of features (hereafter referred to as the option N). The hardware needed for the option N is placed with an RJ45 connector on the left side of the unit, seen from the rear. The option N is delivered through the Ethernet port, and we recommend using a twisted pair category 5 cable (CAT5 as defined in ANSI/TIA/EIA-568-A) for connection of the option N to the network. The option N port automatically detects the cable type, so both twisted and straight cables can be used. DEIF A/S Page 5 of 11

3. Network configuration of the option N The Ethernet port of the Multi-line 2 option N is delivered preconfigured with these network settings: Factory setting IP address 192.168.20.11 Gateway address 192.168.20.200 Subnet mask 255.255.255.0 To be able to configure and use the option N, it must be connected to a network or directly to a PC. The option J4 is for ordering a crossover Ethernet cable from DEIF. This cable can be used to connect the option N directly to a PC. For this to work, the PC must be configured to use the same network as specified above. Go to the control panel via the Start button on the PC screen. Select Network Connections. Select the local area connection used. DEIF A/S Page 6 of 11

Select Internet Protocol (TCP/IP) and use this setting. Option N setup When your PC has been set up as described on the previous pages and the PC is connected directly to the Ethernet socket of the Multi-line 2 unit option N port, you must subsequently check if you have access to the option N port from the internet connection by means of the ping utility programme from your PC. Click Start (lower left corner of the PC screen) and select Run. Type cmd and press the Enter key. Type ping + the IP address of the option N (standard is 192.168.20.19) and press the Enter key (see below). DEIF A/S Page 7 of 11

The above screen dump is displayed when this connection works as it should. Otherwise, it will look like this: Changing the AGC 200 IP address The IP address can be changed in two different ways. 1. Using the Tools menu on the AGC 200 display: Select Ethernet Setup in the Tools menu. This enables you to change the following: IP address (Factory setting 192.168.20.11) Subnet mask (Factory setting 255.255.255.0) Gateway address (Factory setting 192.168.20.200) MAC address (The physical address of the AGC 200. This is specific for the unit in question and cannot be changed). Select any of these to change the value. 2. Using the option N setting in the PC utility software: Connect to the AGC 200 using the TCP/IP link and click the option N icon when connected. The following window appears: DEIF A/S Page 8 of 11

The network parameters can be modified from here to match the final network configuration. If the following window appears, you are not connected to an AGC 200: The above window is useful when working with another product type than the AGC 200, like for example the AGC-3. When changing the IP or gateway address, a power cycle (aux. power OFF and ON) is needed before the changes take effect. Remember to change the communication settings in the utility software (IP address) as well. DEIF A/S Page 9 of 11

4. TCP/IP Modbus communication TCP/IP Modbus is identical with the classical serial Modbus communication, except that the media used for this communication is a TCP/IP communication. So the basic Modbus functionalities will not be explained here, but more information can be found in the Multi-line 2 option H2 (Modbus option) documentation, which can be downloaded free of charge from the DEIF web page www.deif.com. Modicon, today Schneider Electric, introduced the Modbus protocol to the market in 1979. Modbus protocol is a messaging structure used to establish master-slave/client-server communication between intelligent devices. More information is available at www.modbus.org. What is Modbus TCP/IP protocol? TCP/IP is the common transport protocol of the internet and is actually a set of layered protocols, providing a reliable data transport mechanism between machines. Ethernet has become the de facto standard of corporate enterprise systems, so it has also, not surprisingly, become the de facto standard for factory networking. Ethernet is not a new technology. It has matured to the point that the costs of implementing this network solution has dropped to where they are commensurate with those of today's field busses. An open Modbus TCP/IP specification was developed in 1999. The protocol specification and implementation guide are available for download (www.modbus-ida.org/specs.php). The useful parameters required from the software you use to communicate with the option N by means of a TCP/IP Modbus communication are: - The IP address of the option N to talk to - The port number to be used The previous chapters explain the way to set up the IP address parameter of the option N. The port number to be used is 502. DEIF A/S Page 10 of 11

5. TCP/IP Modbus data tables See the AGC 200 option H2 documentation to get the details of the data available by means of the TCP/IP Modbus communication (identical with the serial RS485 Modbus data). DEIF A/S reserves the right to change any of the above. DEIF A/S Page 11 of 11