DL2700-SERIES DIGITAL LOCKS Programming Instructions

Similar documents
Trilogy DL5200 Programming Instructions OI345 10/08

Index. Disable or Enable Code 06. Definition 02 Factory Default Settings 03 Important Notes 03 Change Master Code 03 Add Code 04

Trilogy DL1200ET Programming Instructions WI1686 7/08

Trilogy DL2800 Programming Instructions

Trilogy DL2700LD Programming Instructions

Digital Lock User Guide

Trilogy Double-Sided DL5300 Programming Instructions

Trilogy DL3200 Programming Instructions

Trilogy PL3500 and ETPL Programming Instructions

Trilogy PDL3000 & PDL3500 Programming Instructions

Trilogy PL3500 and ETPL Programming Instructions

Trilogy Double-Sided PDL5300 Programming Instructions

Programming/Troubleshooting Instructions

Product Guide. Key Button. Pull Handle

Keypad Lock. Operation and Service Manual. Order parts online

SCHLAGE KING COBRA - 12 BUTTON WITH BEEPER

Trilogy DL4100 / DL4500 Series Programming Instructions WI1194B 10/07

Product Guide. Key Button. Pull Handle

Wireless Trilogy DL6500 & ETDLN Programming Instructions

eforce 150 Keyless Entry Owner s manual & User s guide For Model 3090

Lock Parts. Keys. Key Insertion. Front Unit. Rear Unit. Product Guide. Standard Keypad Bolt Mechanism. Connection Options

TABLE OF CONTENTS (continued) TABLE OF CONTENTS. March 2006

Setup. Programming Instructions. Product Guide

Digital Electronic Lock OWNER S MANUAL

Trilogy. PDL6500 & ETPDLN Programming Instructions ALARM LOCK 2011 WI1835A 09/11 PDL6500 & ETPDLN

Lock Orientation - Views

Lock Orientation. Keys. Key Insertion. Product Guide. Horizontal with Knob on Left

CO-100. Offline lock user guide Instructions for CO-Series offline locks

Living. Keyfree Connected Smart Lock Manual. smart. The smarter way to protect your home

Trilogy PDK3000 Series Programming Instructions ALARM LOCK 2005 WI 1120D 5/05

DL1300. Programming Instructions. DL Trilogy Series Stand-Alone Access Control Systems OI311 7/06 ALARM LOCK 2006 DL1300

Ultraloq UL3 Series Fingerprint and Touchscreen Smart Lock User Guide ( V1.4 ) Welcome

Lock Orientation - Views

OPERATING INSTRUCTIONS AUDITCON LOCK 100, 200, 400, 500 SERIES

Preparing Door. P/N AYRD-120-STANDALONE-INST-FUL Rev F

ibutton Solo Setup Instructions

DOWNLOAD THE BILT APP. x3 #8-32 x 5/16" Machine screws. x4 #7 wood & #8-32 machine x 20mm Combination screws. x2 M6x55mm Long through bolt

PDL1300 Programming Instructions

ONYX FINGERPRINT PASSWORD LOCK MANUAL

Lock Orientation - Views. Keys. Key Insertion. Product Guide. Keypad Key Managed. Horizontal - Handle on Right. Vertical

CO-100 OFFLINE LOCK USER GUIDE

PDL6100. Wireless Trilogy. Programming Instructions WI1790E 05/15 PDL6100 HID HID CORPORATION PROXIMITY KEYFOB PROXIMITY CARD

Troubleshooting: Locked Turnbutton 6. Troubleshooting: Keypad 7. Troubleshooting: Smart Home Systems 8. Troubleshooting: Battery 10.

Ultraloq UL3 Fingerprint and Touchscreen Smart Lock

LC SERIES OPERATING INSTRUCTIONS MODELS LCLX, LCMX, TLCL, TLCM

PROGRAMMING GUIDE. MARKS USA 365 Bayview Ave., Amityville, NY Fax

Security Door Controls

Troubleshooting: Locked Turnbutton 6. Troubleshooting: Keypad 7. Troubleshooting: Battery 8. Battery FAQ 9

Lock Parts. Keys. Key Insertion. Front Unit. Rear Unit. Product Guide. User Credential User Key. Touch RFID Latch Mechanism. Connection Options

CO-250. Offline lock user guide Instructions for programming CO-Series offline locks

E-PLEX 58XX FIPS LOCK SERIES OPERATIONS MANUAL

USER MANUAL. TL400B Fingerprint Lock with Voice Guide Feature. Version: 1.1 Date: Jul. 2017

Wireless Access Control Keypad

Trilogy. NETWORXPANEL Programming Instructions ALARM LOCK 2012 WI1855B 3/12 NETPDK GATEWAY NETWORXPANEL NETDK

Keypad Programming Instructions For the Access 800 Series Locks

Ultraloq UL3 Fingerprint and Touchscreen Smart Lock. User Guide

Ritenergy Pro. Access Control Systems. Manual Programming Guide. (Firmware Version 3.XX) 1 Introduction Programming Guide ritelock.

Operating Instructions KEYPAD. Compatible WIRELESS ACCESS CONTROL

Yale Real Living Assure Lock Touchscreen Deadbolt Installation and Programming Instructions (YRD226)

Users Manual. Operating and Installation Instructions Buffalo River Black Dimaond. Model:ECSL-0601A Electronic Combination Controller

Section 1 General Description. Section 3 How to Program Keypad. Section 2 Installation. CM-120TX Wireless Digital Keypads Installation Instructions

SK-1011-SQ Digital Access Keypad with 5A Relay Output

Access 800TM. Keypad Programming Instructions. Locks CYLINDRICAL EXIT MORTISE

Installers & User guide Smart Mortise.

Wireless Trilogy Networx PL6600 & ETPLNRX Programming Instructions

ENFORCER SK-1131-SQ. Digital Access Keypad with 5A Relay Output MANUAL. Digital Access Keypad Manual. Also available from SECO-LARM: Outdoor Keypads

INSTALLATION INSTRUCTIONS

IDS X-Series User Manual E Issued June 2013

IQ PROX. Programming Guide. Series. For use with IQ KP* only

Created by: Alarm System Store Quick Start Guide. for Interlogix NetworX NX4, NX6 & NX8

INSTALLATION INSTRUCTIONS 920 EntryCheck TM

INSTALLATION INSTRUCTIONS 921P EntryCheck TM

nextouch Touchscreen and Push Button Keypad Sectional Mortise Lock Installation and Programming Instructions

Lock Orientation - Views. Cam & Cam Stop Position. Product Guide !! READ FIRST!! Keypad Camlocks Key Managed. Vertical. Horizontal Left Handed

PAD LOCK. code: PL369 COMBINATION LOCK INSTRUCTION

Lock-Duo Redundant Lock & Keypad

User Manual. Smart Lock. Please read this manual before operating your Smart Lock, and keep it for further reference. 40

NAPCO SECURITY TECHNOLOGIES, INC. 333 Bayview Avenue, Amityville, New York, U.S.A (631) FAX (631)

Wireless Trilogy Networx PL6100 Programming Instructions

Installers & User guide Smart Mortise.

DG-800 Stand-Alone Proximity Reader Instruction Manual

AS Keypad User Manual

INSTALLATION INSTRUCTIONS 920P EntryCheck TM

Yale Real Living Key Free Touchscreen Deadbolt Installation and Programming Instructions

Up to 5 permanent PINs and Tri-band 390 MHz, 315 MHz, and 310 MHz. Up to 10 unique temporary PINs KPW250

ITEM: Digilock ATS - Recess Mount, No Pull Handle, Brushed Nickel, Black for 3/4" Door BRAND: Digilock $138.3

CHECK LIST 2 QUICK START 3 SAFE OPERATION & PROGRAMMING 3 HOW TO OPEN YOUR SAFE 3 CHANGING THE USER CODE 3 LOW BATTERY WARNING 4

Series. NX-8-EUR Control Panel. Installation manual

XP-KIT. Programming & Operations. Programming Starter Kit for Aiphone -XP Series Proximity Reader Stations

UCA, INC. ACCESS CONTROL SOLUTION ETERNITY USER GUIDE. Version 2.1

MODEL KP-100 ACCESS CONTROL DIGITAL KEYPAD OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS

Troubleshooting: Installation 10. Troubleshooting: Door Jamming and Door Handing 11. Troubleshooting: Touchscreen 14. Troubleshooting: Battery 15

AUDITGARD. LGA Electronic Combination Locks. manager instructions PROGRAMMABLE LOCK FEATURES STANDARD LOCK FEATURES

INSTALLATION INSTRUCTIONS 923P EntryCheck TM

ENFORCER. SK-1123-SQ Outdoor Digital Access Keypad with 2 Outputs MANUAL. Digital Access Keypad Manual. Also available from SECO-LARM: Outdoor Keypads

User Manual SOLOgarde

USER MANUAL OF FINGERPRINT DOOR LOCK

IDS. Users Guide to Keypad Functions S E C U R I T Y MANUAL NO D ISSUED NOVEMBER 2002 VERSION 2.

FTK5 PROXIMITY KEYPAD

Transcription:

DL2700-SERIES DIGITAL LOCKS Programming Instructions If a wrong code is entered, the red LED will flash 5 times. If the batteries are weak, pressing any button will cause the red LED to come on, along with a steady sounder OI209 4/96 UL LISTED: ELECTRICALLY-CONTROLLED SINGLE-POINT LOCK USER S GUIDE TO DL2700-SERIES CODES AND FEATURES CONGRATULATIONS! Your new Alarm Lock Trilogy electronic digital lock is a rugged entry lock of advanced design with several programmable features. Three security levels are provided: Master, Management, and User, the latter comprising 15 User Codes, including a 1-time entry Service Code. Take the time to read through this guide to familiarize yourself with the features and operation of the lock, and its quick and easy programming procedures. PRELIMINARY INFORMATION The DL2700 allows you to program 1 Master Code (all functions including entry) 1 Management Code (all functions including entry, but not Master Code, Management Code or Passage Function) 15 User Codes (3 banks of 5; entry only) 1 Service Code (1-time entry) Important: Before attempting to program any codes or functions, note the following: While the lever or knob may be rotated at any time, the latch will not be engaged to unlock the door unless a valid code has been entered. When a valid code is entered, the lock will unlock immediately and remain unlocked for about 5 seconds (or longer, if reprogrammed). When attempting to change a code, the respective program address and replacement code must be entered while unlocked. Therefore, it is recommended that all codes be prepared in advance for reference while programming (see Program Sheet), then be secured when finished. Audible Indications A beep will sound (a) when each key is pressed and (b) after a valid code is entered and (c) at the end of the unlock time (just before the unit relocks). If a wrong key is pressed during code entry, press the [AL] Button to clear the entry and start again. Two beeps will sound at the end of the antitamper lockout time. Five beeps will sound upon entry of an invalid code. Six beeps indicate acceptance of a programmed code. A 5-second tone (with red LED) when a key is pressed signifies a low-battery condition. LED Indications LED indications are especially useful when the lock is used in noisy environments. Red LED The red LED will light momentarily whenever a key is pressed.

indication. Green LED The green LED will come on momentarily when a valid code has been entered. PROGRAMMING YOUR CODES Master Code The Master Code can program any entry code or function. It may consist of 3 to 5 digits; the number of digits selected determines the number required for all other codes. The factory-programmed code is 1-2-3-4-5, but this code must be changed as follows to preserve security. For example, change the factoryprogrammed Master Code to 5-4-3-2-1. Note: Changing the Master Code will erase all other codes. 1. Enter existing Master Code: [1] [2] [3] [4] [5]. 2. Within 5 seconds, enter Master Program Address: [AL] [1] [AL]. 3. Within 5 seconds, enter new Master Code: 4. (For Master Code only): Press [AL]. 5. Enter Master Code again to validate (only the Master Code must be validated): Six beeps will sound and lock will relock after about five seconds. 6. Test the new Master Code. Enter: Note: If only one code is required, stop here and proceed to PROGRAMMING SPECIAL FUNCTIONS. Management Code The Management Code can program any user code (but not the Master or Management Code) or any programma- ble function except the Passage Function. It must contain the same number of digits as the Master Code. The follow- ing example will program a Management Code of 2-3-4-5- 1 using the Master Code programmed in the example above. Note: Changing the Management Code will not affect any other code. 1. Enter the existing Master Code: 2. Within 5 seconds, enter the Management Program Address: [AL] [2] [AL]. 3. Enter the Management Code: [2] [3] [4] [5] Six beeps will sound and lock will relock after about five seconds. 4. Test the Management Code. Enter: [2] [3] [4] [5] Note: If only two codes are required, stop here and proceed to PROGRAMMING SPECIAL FUNCTIONS. User Codes (Provide entry only) Up to 15 User Codes are available in three banks, each containing five users. User Codes are programmed by either a Master Code or a Management Code and the respective User Program Address shown below. Users may be locked out either individually or by bank, therefore when assigning codes, consider which users or groups will

be denied access on a regular basis to simplify the lockout procedure. User Codes must consist of the same number of digits as the Master Code. To program any User Code: 1. Enter the Master Code or Management Code. A beep will sound and the lock will unlock. 2. From Table 1, enter the Program Address for the selected user. PROGRAM PROGRAM PROGRAM BANK 1 ADDRESS BANK 2 ADDRESS BANK 3 ADDRESS User 1 AL-1-1-AL User 1 AL-2-1-AL User 1 AL-3-1-AL User 2 AL-1-2-AL User 2 AL-2-2-AL User 2 AL-3-2-AL User 3 AL-1-3-AL User 3 AL-2-3-AL User 3 AL-3-3-AL User 4 AL-1-4-AL User 4 AL-2-4-AL User 4 AL-3-4-AL User 5 AL-1-5-AL User 5 AL-2-5-AL User 5* AL-3-5-AL * May be programmed as Service Code (AL-3-AL). See Service Code. Table 1. User Program Addresses. 3. Enter the User Code; six beeps will sound. 4. Test the User Code. Note: If several User Codes will be programmed at one time, it is not necessary to re-enter the Master or Management Code for each, so long as the lock is not allowed to relock. Therefore, after the six beeps sound (step 3, above) repeat steps 2 and 3 as necessary, then test all codes when done. Service Code The Service Code is a one-time User Code for cleaning crews, servicers, etc., that erases itself immediately after use. It is programmed as any User Code, with the Program Address AL-3-AL. If programmed, the Service Code replaces User Code 15 (Bank 3, User 5). PROGRAMMING SPECIAL FUNCTIONS Lockouts Any single user, any bank of users, or all users may be prevented from entry. User Lockout. To temporarily disable any single user s entry code, 1. Enter the Master Code or Management Code. 2. From Table 1, enter the user s Program Address. 3. Wait for the lock to relock. To re-enable the code, repeat the procedure. Group Lockout. To temporarily disable all user entry codes of one or more banks, 1. Enter the Master Code or Management Code. 2. From Table 2, enter the Bank Disable Address(es). BANK DISABLE ADDRESS ENABLE ADDRESS 1 AL-5-1-AL AL-4-1-AL 2 AL-5-2-AL AL-4-2-AL 3 AL-5-3-AL AL-4-3-AL 1--3 AL-5-5-AL AL-4-4-AL Table 2. Bank Disable and Enable Addresses. 3. Wait for the lock to relock. To re-enable the code(s), repeat the procedure, replacing the Disable Address in Step 2 with the Enable Address. Note: Re-enabling a group lockout does not re-enable a single-user lockout of that group (see User Lockout). Unlock Time This is the amount of time that the lock stays open after a valid code is entered. The factory-programmed time is 5 seconds, however this time may be increased to up to 20 seconds as follows. 1. Enter the Master Code or Management Code. 2. Enter Address [AL] [4] [5] [AL]. 3. From Table 3, enter the desired unlock time. ENTRY TIME 1 5 SEC. 2 10 SEC. 3 15 SEC. 4 20 SEC. Table 3. Unlock Times (times approximate). Note: To conserve battery power, keep unlock time as short as possible. Passage Programming the Passage Function will maintain the DL2700 unlocked (no code required for entry) until reprogrammed. To set the Passage Function, enter the Master Code, then Address [AL] [4] [AL]. To relock, enter the Master Code, then Address [AL] [5] [AL]. OTHER IMPORTANT INFORMATION Antitamper Protection If three invalid codes are entered in succession, the unit will shut down for approximately 20 seconds to prevent code tampering. Two short beeps will sound when the lock has been reactivated. Battery Replacement A 5-second dual tone (4 seconds high; 1 second low) when any key is pressed indicates that the batteries are weak. The DL2700 uses 5 AA-size1.5-volt alkaline batteries. The lock will function with weak batteries, however be sure to replace the batteries as soon as possible. Remove the screw at the bottom of the interior lock housing and remove the cover. Replace all 5 batteries quickly ---- within about 2 minutes ---- to avoid losing the memorized codes. Do not press any buttons while replacing the batteries! Replace the battery cover, then test the lock. Note: To immediately erase all codes, remove the batteries and press any button. Should battery power fail and all codes be erased, open the door using the key and replace the batteries. Reprogram all codes starting with the original factory Master Code (1-2-3-4-5). Remote Release Provisions for unlocking the DL2700 from a remote location, overriding all codes, using an external momentarycontact switch.

PROGRAM WORKSHEET: CODES Instructions: The Factory Master Code (1-2-3-4-5) may not be used for programming; it must first be reprogrammed as a new Master Code to enable its programming capabilities. Fill in codes in spaces provided prior to programming. All other codes must have the same number of digits as the new Master Code (3 to 5 digits). To load desired code, first enter Master or Management Code (except where indicated) and Program Address before unit relocks, then enter the code. 1. MASTER CODE. Must be programmed. Enter existing Master Code, then Program Address before unit relocks. Enter new Master Code, then press [AL]. Verify as shown. Press: 1 2 3 4 5 (beep) [ AL] [ 1] [ AL] Press [ AL] (for Master Code only) (Factory Master Code) (Program Address) (Master Code) 2. MANAGEMENT CODE. Enter Master Code, then Program Address before unit relocks. Enter Management Code. Verify (enter Master Code again): (6 beeps = OK) Press: (Master Code) (beep) [ AL] [ 2] [ AL] (Program Address) 17. USER 15 CODE*. [ AL] [ 3] [ 5] [ AL] (6 beeps = OK) Note: User Code provides entry only. To disable any user, enter Master or Management Code, respective Program Address, but no User 18. SERVICE CODE*. [ AL] [ 3] [ AL] (6 beeps = OK) Code. Allow unit to relock. * User 15 s code may be used as a Service Code allowing one-time entry only. (Management Code) (6 beeps = OK) 3. USER 1 CODE. Enter Master or Management Code, then Program Address before unit relocks. Enter User 1 Code. Press: (beep) [ AL] [ 1] [ 1] [ AL] (6 beeps = OK) (Master or Management Code) (Program Address) (User 1 Code) 4. USER 2 CODE. [ AL] [ 1] [ 2] [ AL] (6 beeps = OK) 5. USER 3 CODE. [ AL] [ 1] [ 3] [ AL] (6 beeps = OK) 6. USER 4 CODE. [ AL] [ 1] [ 4] [ AL] (6 beeps = OK) 7. USER 5 CODE. [ AL] [ 1] [ 5] [ AL] (6 beeps = OK) 8. USER 6 CODE. [ AL] [ 2] [ 1] [ AL] (6 beeps = OK) 9. USER 7 CODE. [ AL] [ 2] [ 2] [ AL] (6 beeps = OK) 10. USER 8 CODE. [ AL] [ 2] [ 3] [ AL] (6 beeps = OK) 11. USER 9 CODE. [ AL] [ 2] [ 4] [ AL] (6 beeps = OK) 12. USER 10 CODE. [ AL] [ 2] [ 5] [ AL] (6 beeps = OK) 13. USER 11 CODE. [ AL] [ 3] [ 1] [ AL] (6 beeps = OK) 14. USER 12 CODE. [ AL] [ 3] [ 2] [ AL] (6 beeps = OK) 15. USER 13 CODE. [ AL] [ 3] [ 3] [ AL] (6 beeps = OK) 16. USER 14 CODE. [ AL] [ 3] [ 4] [ AL] (6 beeps = OK) PROGRAM WORKSHEET: FUNCTIONS Instructions: To program desired function, (1) enter Master Code or Management Code (except where indicated); (2) enter respective Program Address before unit relocks; (3) see notes, if any. 1. RE-ENABLE BANK 1 Press: (beep) (Master or Management Code) [ AL] [ 4] [ 1] [ AL] (Program Address) 2. RE-ENABLE BANK 2 [ AL] [ 4] [ 2] [ AL] 3. RE-ENABLE BANK 3 [ AL] [ 4] [ 3] [ AL] 4. RE-ENABLE BANKS 1--3 [ AL] [ 4] [ 4] [ AL] 5. UNLOCK TIME [ AL] [ 4] [ 5] [ AL] Note: Press 1 for 5 sec.; 2 for 10 sec. 3 for 15 sec.; 4 for 20 sec. 6. ENABLE PASSAGE [ AL] [ 4] [ AL] Note: Code not required for entry. (Program using Master Code only.) 7. DISABLE PASSAGE [ AL] [ 5] [ AL] Note: Code required for entry. (Program using Master Code only.) 8. DISABLE BANK 1 [ AL] [ 5] [ 1] [ AL] 9. DISABLE BANK 2 [ AL] [ 5] [ 2] [ AL]

10. DISABLE BANK 3 [ AL] [ 5] [ 3] [ AL] 11. DISABLE BANKS 1--3 [ AL] [ 5] [ 5] [ AL] Note: Total user lockout

USER CODE RECORD LOG USER DESCRIPTION USER S NAME CODE ---- MASTER ---- MANAGEMENT ---- SERVICE 1 BANK 1, USER 1 2 BANK 1, USER 2 3 BANK 1, USER 3 4 BANK 1, USER 4 5 BANK 1, USER 5 6 BANK 2, USER 1 7 BANK 2, USER 2 8 BANK 2, USER 3 9 BANK 2, USER 4 10 BANK 2, USER 5 11 BANK 3, USER 1 12 BANK 3, USER 2 13 BANK 3, USER 3 14 BANK 3, USER 4 15 BANK 3, USER 5

Alarm Lock Systems 345 Bayview Avenue Amityville, New York 11701