Datacentre Reading East 2 Data sheet

Similar documents
Datacentre Milton Keynes Data sheet

Datacentre Newbridge Data sheet

Datacentre Milton Keynes Hall C Data sheet

DATA CENTRE & COLOCATION

Data Center. Tai Po Data Center

Rack Colocation Hosting. Data Centre Solutions Expertly Engineered

Data Centre Stockholm II, Sweden Flexible, advanced and efficient by design.

STATE OF THE ART DATA CENTRES

A next generation Colocation data centre for Birmingham city centre

Data Centre & Colocation in Birmingham. Flexible. Secure. Accredited.

COLOCATION 1/4 RACK RACK COLD AISLE CONTAINEMENT PRIVATE CAGE PRIVATE SUITE FLEXIBLE PRICING OPTIONS

Data Centre Solutions. Data Centre Solutions Expertly Engineered

POWERING A CONNECTED ASIA. Pacnet Hong Kong DataSpace1 Technical Specifications. Advanced Data Center Facility for Multi-Site Enterprises

World Class. Globally Certified. High Availability.

CUS. Introducing New Zealand s most connected data centre. Albany, Auckland

DUB4. An innovative data centre. Resilience. Power. Flexibility AT NORTHWEST BUSINESS PARK

TIER 3+ CARRIER NEUTRAL DATA CENTER TELEPOINT SOFIA EAST THE LATEST ADDITION TO OUR FAST-GROWING DATA CENTER LOCATIONS.

IXcellerate Moscow One Datacentre - Phase 1 & 2 Overview

DATA CENTRE & COLOCATION

PEARL MANHATTAN, NY

Fact sheet FRANKFURT DATA CENTRE CAMPUS. Connect, transact and grow

Datacentres & Colocation

Data Center. Data Centers in Hong Kong

Fact sheet BRUSSELS DATA CENTRE CAMPUS. Connect, transact and grow

Fact sheet COPENHAGEN DATA CENTRE CAMPUS. Connect, transact and grow

NTT Communications data center services. Key european data centers

3300 kw, Tier 3, Chilled Water, 70,000 ft 2

84 kw, Tier 3, Direct Expansion, 937 ft 2

AMS6, Amstel Business Park Campus. Highly connected, Energy efficient data centre. Duivendrechtse kade 80A 1096 AH Amsterdam Netherlands

JT Rue Des Pres DATA CENTRE

The Region s Leading Data Center Developer, Manager and Operator

MD-ALPHA DATA CENTER. Hagerstown, Maryland

Fact sheet DUBLIN DATA CENTRE CAMPUS. Connect, transact and grow

10 QUESTIONS TO ASK YOUR DATA CENTRE

KAO DATA CAMPUS DATA CENTRES AT THE HOME OF INNOVATION

Fact sheet VIENNA DATA CENTRE CAMPUS. Connect, transact and grow

WHITE PAPER. Solutions OnDemand Hosting Overview

RFP Questions Guideline For Data Center Buyers

An Adaptive Data Center for Dynamic IT Aligned Energy s Dallas-Plano Data Center

Optimize Your Data Center. Gary Hill VP, Business Development DVL Group, Inc.

DATA CENTRE. JT First Tower Lane. Facility Product Description. Data Centre Services

CenturyLink Data Center Services Omaha, Nebraska

Data Center. Hong Kong Financial Data Center

Modular & Mobile Data Centre Solutions. Data Centre Solutions Expertly Engineered

brightsolid Data Hall 1 Keysource Technical Specifications

2000 kw, Tier 3, Chilled Water, Prefabricated, sq. ft.

DATA CENTRE. JT Five Oaks. Facility Product Description. Data Centre Services

Dazelidis Thanos - Product Manager Rittal Greece 1

DATA CENTER COLOCATION BUILD VS. BUY

1008 kw, Tier 2, Chilled Water, ft 2

CenturyLink Data Center Services Herndon, Virginia

Dude Solutions Business Continuity Overview

Access UK Ltd. Data centre Security. Data Centre Summary v.2.0 _ December Date: 12 th January Version: 1.1. Parkinson / Daniel Gould

London s Data Centre provider

Data Center RFP Template

CARRIER NEUTRAL, PROVIDING ACCESS TO A RICH CONNECTIVITY AND CLOUD ECOSYSTEM

Data Centre Infrastructure

APC by Schneider Electric Elite Data Centre Partner

Introduction. Service and Support

COLOCATION A BEST PRACTICE GUIDE TO IT

<Insert Picture Here> Austin Data Center 6Sigma DC CFD Model

Data Center Checklist

PT Sigma Cipta Caraka (Telkomsigma)

A Data Center Heat Removal System That Saves... 80% Discover Inertech s Award-winning Data Center Heat Removal System

Fact sheet AMSTERDAM DATA CENTRE CAMPUS. Connect, transact and grow

Art and Science of Building NUS Data Centres

Continuity Insights Chicago: Evolving Data Center Trends & Design Standards. 19 June Jose Hernandez, 30+ years of design/build experience

NTT Communications data center services

DATA MSP RD AVE S MINNEAPOLIS, MN MINNEAPOLIS, MINNESOTA

AT&T Enterprise Hosting Services

Charles Nolan. Do more with less with your data centre A customer s perspective. Director IT Infrastructure, UNSW. Brought to you by:

Critical IT Facilities at the Edge

Industry leading low energy evaporative fresh air cooling.

Fact sheet ZURICH DATA CENTRE CAMPUS. Connect, transact and grow

Fact sheet PARIS DATA CENTRE CAMPUS. Connect, transact and grow

HYBRID CLOUD BACKUP & DISASTER RECOVERY

Data Centre In A Box

Prefabricated Data Center Solutions: Coming of Age

2055 E TECHNOLOGY CIRCLE

Providing premium colocation and networking solutions to end user clients

Customizable Colocation: Building for the Future

5.2 MW, Pod-based build, Chilled Water, ft 2

Multiplying disruption: Modular data centres at the edge

SMART SOLUTIONS TM INTELLIGENT, INTEGRATED INFRASTRUCTURE FOR THE DATA CENTER

Fact sheet LONDON DATA CENTRE CAMPUS. Connect, transact and grow

Maximising Energy Efficiency and Validating Decisions with Romonet s Analytics Platform. About Global Switch. Global Switch Sydney East

Microsoft s Cloud. Delivering operational excellence in the cloud Infrastructure. Erik Jan van Vuuren Azure Lead Microsoft Netherlands

Infrastructure as a Service (IaaS) Compute with Storage and Backup PRICING DOCUMENT

Efficiency of Data Center cooling

PROCESS & DATA CENTER COOLING. How and Why To Prepare For What s To Come JOHN MORRIS REGIONAL DIRECTOR OF SALES

TURN-KEY AND BUILD-TO-SUIT WHOLESALE DATA CENTER SOLUTIONS

Case Study Leicester City Council

QuickSpecs. HP Performance Optimized Datacenter (POD) 20ce. Overview. Retired

TX1 230,000 SQ. FT. 16MW AVAILABLE NOW RAGINGWIRE DALLAS, TX 1MW, 2MW, 3MW AND 5MW 42 ACRE DATA CENTER CAMPUS CUSTOMIZABLE PRIVATE SUITES

SmartMod Intelligent, Integrated Infrastructure for the Data Center

KEEPING YOU OUT IN FRONT

FOM 2.4 The Performance Indicator: Assessing & Visualizing Data Center Cooling Performance

Thermal management. Thermal management

Twin Core Data Center Munich

HPC Solutions in High Density Data Centers

Transcription:

Datacentre Reading East 2 Data sheet

Data sheet Datacentre Reading East 2 Find us With 10 datacentres, over 4,500 racks and a 10Gb resilient core network between our datacentre locations, Pulsant has the infrastructure to support you. Suttons Business Park Reading Berkshire RG6 1AZ United Kingdom Tier 3 Datacentre site 40 minutes from Central London servicing a wide range of business critical systems for financial services, telecoms and retail customers. Pulsant use a variety of security measures to ensure your infrastructure remains safe. A high security facility with high performance cooling. Site Overview Capacity - Supporting a total of 200 racks in 48U 600mm x 1,000mm up to 7kW dual diverse power supplies. Available in ¼, ½ and full rack. Configuration - 1 Secure Data Hall racks available in Amp, kw per annum and kwh models in singular racks or rows. Support - 24x7 on-site remote hands, monitoring and support available to all customers. On-site Cloud, Government Cloud, Managed Services and Colocation. Security - 24x7 manned site with HD CCTV cameras, PAC access controlled into each area of the site, on-site provisioning and technical support teams. Power - 1,500kVA incoming supply from SSE to on-site substation and transformer. Cooling - Blended N+1 Chilled Water and Free Air redundant cooling solutions to 1,100kW. UPS - N+1 Modular PowerWAVE DPA high efficiency units with up to 15 minutes autonomy. Standby Generation - 2 x 500kVA Standby Rated units in N+1 configuration. info@

Data sheet Data sheet Total Technical DC Sq Ft - 6,500 No of Data Halls - 1 Total Rack Capacity - 200 Building Floors - 1 Floor Void - 1,000mm Tier Rating - Tier 3 Total Power Provision - 1.5MW Total Power Protection - N Total UPS Provision - 0.8MW Total UPS Protection - N+1 Rack Provision - Single 16Amp or 32Amp Total Generator Provision - 0.8MW Total Generator Protection - N+N Total Generator Fuel Storage - 3,000 Litres Total Cooling Provision - 1.1MW Total Cooling Protection - N+1 Cooling Type - Chilled Water with Free Cooling CCTV - Total Cameras - 9 Cameras CCTV - Retention Period - Minimum 45 Days Access Control - Type - Swipe Entry/Exit Access Control - Retention Period - Minimum 6 Months Fire Protection Systems - Floor and Ceiling Sensors Fire Suppressant Systems on-site - FM200 Reading East 2 site colocation propositions Rack Capacity - 200 1U Server 1/4 Rack 1/2 Rack Full Rack Oversized Rack Dual PDU Cage Suite 1Mb - 1Gb Transit Dark Fibre With Pulsant, we have access to secure enterprise class datacentre facilities without unnecessary capital expense. IT DIRECTOR AT AWARD WINNING FINANCIAL SERVICE COMPANY, 7IM. Site Backhaul Carriers - 9 PCI-DSS SP 2.0 ISO 27001:2013 Managed Server Colocation Backup DC Connectivity On-Net Services - BT, Virgin Media, KCOM, Vodafone, GEO, City Fibre Services, Colt, Level 3 Backed by our Triple A Support 24/7/365 Technical Support - One call takes you straight through to our dedicated technical teams at a Pulsant datacentre in the UK. Skilled system and network admin - All Pulsant s operatives are Rapid triage and escalation ensure requests are processed quickly for a positive experience and quality result. info@

POWER & GENERATORS To eliminate risk from outage or power failure, the site uses diverse supplier feeds from multiple grid points ensuring there is no single point of failure. The site will provide 2N+1 redundant power systems and power feeds up to 10kW per racks to ensure unrivalled power continuity. FIRE DETECTION & SUPPRESSION Ensuring our infrastructure and customer equipment operate safely is one of our greatest concerns. The facility is equipped with VESDA fire detection which continuously sample the air for smoke particles. In the event of an alert we have installed a FM200 suppression system. DATACENTRE FACILITIES Pulsant have built a number of client facilities into the site to ensure any time you spend on-site is comfortable. There is ample provision for client IT staff who may be required on-site, this includes parking, rest rooms, kitchen, build facilities, dedicated offices and meeting rooms. COOLING & PERFORMANCE Energy is vital to power and cool servers, we reduce energy consumption and costs by using ultra-efficient systems and advanced cold aisle and pod technology. MULTI LEVEL SECURITY Pulsant do everything possible to prevent unauthorised access to the site, buildings and data halls as well as to the rack housings themselves. We have systems in place to identify and react to threats so that your infrastructure is protected from theft, damage or interference. The site is a PCI DSS Level 1 compliant facility. NETWORK & CONNECTIVITY When creating the data campus we needed to ensure we had ultra-fast connectivity with low latency to London locations. We achieved this as the site houses diverse network connectivity via Dark Fibre to multiple London points of presence with 2ms of network latency.

Data sheet PULSANT ELEMENTS Created to answer your business needs Ultra-reliable, flexible, scalable, secure solutions, stand-alone or hybrid service combinations, designed to deliver your business-specific needs. HOW WE ENGAGE Continual Technology Optimisation We enable businesses to grow quickly and efficiently through a continuous process of optimal deployment and use of technology. HOW WE DELIVER Discover your Hybrid Solution Combining Pulsant Elements to create business solutions that address essential business needs. info@