LM10 to MM200 Retrofit

Similar documents
Multilin MM200. Low Voltage Motor Protection and Control. Protection and Control. Metering & Monitoring. Communications. EnerVista Software

MM300. Integrated automation and protection for low voltage motors. Digital Energy Multilin. Metering & Monitoring. Protection and Control

GE Power Management. MMII Intelligent MCC Controller

Multilin EPM 6010 YEAR. GE Grid Solutions. Building Automation Power Meter with BacNET /IP Communications. Monitoring & Metering

Multilin EPM Energy and Demand Submeter with Wi-Fi. Monitoring & Metering. Communications. Key Benefits. Applications

LM10 Motor Protection System Instruction Manual

g Energy Multilin Voltage Regulator Controller DGCV KEy BENEFITS APPLICATIONS FEATURES Metering & Monitoring Voltage Regulation Communications

www. ElectricalPartManuals. com l Basler Electric MPS100 MOTOR PROTECTION SYSTEM ADVANTAGES WINDOWS SOFTWARE ADDITIONAL INFORMATION

E1 Plus Electronic Overload Relay

Quantum III. Compact DC Drive Package. Slitter DC Drive Package. Quantum III

SECTION SOLID-STATE REDUCED VOLTAGE STARTERS

EPM g Energy. Multilin BUILDING AUTOMATION POWER METER. BACnet /IP Communications and Energy Measurement KEY BENEFITS APPLICATIONS FEATURES

SORDS ELECTRIC ~ MA7200. Sensorless Vector AC Inverter.

JK Series POWER DISTRIBUTION. Solid State Starters Medium Voltage A

IPS INTELLIGENT PUMP STARTER

One relay for safety and process continuity

Easy To Use OEMS Take Note

FM2. Economical and compact feeder protection for low voltage feeders. Digital Energy Multilin. Monitoring & Metering. Protection and Control

MIC-2 Multi-instrument DATA SHEET

MIN II. Complete numerical ground directional protection. Digital Energy Multilin. Protection and Control. Monitoring and Metering.

EM132 EM132. Main Features. Multi-functional 3-Phase Transducer. Energy Meter

SSW06. Soft Starters. Applications. Standard Features. Pumps Fans Blowers Compressors Crushers Saws Grinders Mixers.

Bulletin 825-P Modular Protection System

g Energy Multilin Recloser Controller DGCR Communications Protection Automation & Control Security & EnerVista Software Hardware Metering & Monitoring

SSW06. Soft Starters.

PM174 PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER. Features

MIC-2 MKII & MIC-2 MKII DIN, Multi-instrument DATA SHEET

Motor Protection Solutions. Bulletins 193, 592, 809S, 813S, 814S, 817S and 825-P

EMS 1Ø, 120 ~ 230V, 1/10-25HP 3Ø, 200 ~ 600V, 1/2-300HP

MM200 Motor Management System Communications Guide

SMARTSTART MOTOR STARTERS

MODERNIZE YOUR DC CRANES. Convert Your DC Controls to State-of-the-Art Energy Efficient OmniPulse DDC Series 2 Drives

Packaged Solutions. Grid Solutions. Value Added Solutions for Protection, Control and Automation Applications. Flexible and Expandable

ADJUSTABLE SPEED DRIVES. QX7 Series. HVAC 18-Pulse. Phone: Fax: Web:

OVERLOAD RELAYS POWER & ACTUATION PROVEN. series

ENERGY MANAGEMENT SOFT-STARTER THE MOST INTELLIGENT SOFT-STARTER YET

REL52002 Easergy P3U30, 4L, 4U, 16DI/8DO, Uaux: V, DI: V, RS-485

Universal Motor Controller UMC22-FBP. Excellent motor protection and control ATEX ABB

GE Power Management. UR F60 Feeder Management Relay An integrated feeder protection and metering solution

Multilin 339. Motor Protection System Intuitive Motor Protection. Protection and Control. Communications. Metering & Monitoring. EnerVista Software

Maximize process uptime with the SEL-patented motor thermal model.

MM200 Motor Management System

469 Motor Management Relay

How to control and monitor up to 16 Motor Insight motor protection relays via an HMi and Modbus serial

DIRIS A. Multifunction measurement units for managing your electrical networks

Q9 ASD LOW VOLTAGE DRIVE

MIC-2 MKII, Multi-instrument DATA SHEET

SECTION SWITCHBOARDS

Unidrive M200 Integration through flexible communications

TeSys IEC Contactors and Overload Relays

SYMAP R Plug in Variants FI, MI, 87M, TI Technical data

SR489 SR489. Generator Management Relay. Economical protection, metering, and monitoring functions for small and medium sized generators.

LC-1 Level Controller & Flow Monitor

FUSION COMPACT. Load a. Line A. Inverse parallel scrs. Line B. Line c. inverse parallel scrs. Load C SCR POWER. O delta CONTROLLERS

Line A. Inverse parallel scrs. Load a FUSION. Line B SCR POWER. O delta CONTROLLERS. Line c. inverse parallel scrs. Load C. FUSION Brochure Rev 3.

Digistart. Soft starters for 3 phase induction motors 7.5 to 800kW (18 to 1600A) 200V, 400V, 575V, 690V

02/11/2015

Spectra RMS Circuit Breakers with microentelliguard Trip Units

Current Fault Signatures and Analysis Auto-calibrating metrology means the meter maintains its accuracy over temperature and time

HVAC Products. Introducing the SED2 Variable Frequency Drives

NewCode. Comprehensive Motor Protection and Control Relay. Relay Field Input and Output LEDs. LED Fault Indicators

ADJUSTABLE SPEED DRIVES. GX7 Series

GE Multilin 350 Feeder Protection Relay Specifications

Technical data sheet. PowerLogic power-monitoring units EM3500 series DIN Rail meter

Applications requiring fast and secure communications Protection of pumps, conveyors, fans, compressors, etc.

Power Xpert Meter 350 (PXM350) three-phased DIN-rail multifunction meter

SDM-8AO. Expansion Module 8 analog outputs. Manufactured for

PowerFlex 400 AC Drive Guide Specification

Built-in features Built-in simplicity Built for fans & pumps

SIGMA. Advanced Generator Protection and Control. Short Form Catalogue

BT300 HVAC Drives Electronic Bypass (E-Bypass) Options

THYRO-S THYRO-A THYRO-AX THYRO-PX

Instruction Manual. MM300 Motor Management System * AC* GE Grid Solutions. Low Voltage Motor Protection and Control

Programmable Logic Controllers. and Components for Industrial Automation. altus. evolution in automation.

Intelligent Technologies QCPort Cover Control

QCPort Cover Control Trouble Shooting Guide

Protection relays.

NE1A/DST1. DeviceNet Safety System

MW/MVAR Transducer Specifications

OrionLX. An Overview of the OrionLX Product Line

Product Sheet ECO. Types ECG, AMF Technical data. product sheet eco ecg-amf - technical data gb v1.0.docx

SENSORLESS VECTOR CONTROL

PowerFlex 40 Sample Specification

Overcurrent and Arc Protection by Reyrolle Alexander Erokhin. 21, 2017 I Berlin

SECTION ( ) LIGHTING CONTROL PANELBOARD

Motor control and protection Universal Motor Controller UMC100-FBP

MICROFUSION FEATURES OPTIONS CERTIFICATIONS (PENDING) THREE PHASE SCR POWER CONTROLLERS

EM133 EM133 TOU SMART ENERGY METER. Main Features. Multifunctional 3-Phase Smart Meter. Billing/TOU Energy Meter

DV-300 DC DRIVE. DV-300 DC Drive

MENTOR MP/QUANTUM MP DC Drive Solutions

SACE Emax 2 Specification guide

Outline. 1. Introduction 2. Why Upgrading? 3. Who Is Affected? 4. How to Upgrade? 5. Benefits of the New Upgraded UR

The SV9000. The Comprehensive Drive Solution.

Lowering Lifecycle Costs

M60 Motor Relay. UR Series Instruction Manual. GE Industrial Systems. Title Page. M60 Revision: 3.4x

P7000 Stepper Drives. P7000 Introduction

TECHNICAL BROCHURE BCPNEMAST R0. NEMA Rated Three-Phase Starters BY EATON

Controls Enclosed Non-Combination Starters - PESW Series

SIRIUS 3RB24 Solid-State Overload Relays with Complete Starter Functionality via IO-Link

Power Xpert C445 Competitive Comparison

Transcription:

Grid Solutions LM10 to MM200 Retrofit Replace old LM10 Motor Controller relays with the Multilin TM MM200 Motor Management System The LM10 Motor Controller (discontinued in 2013) has been replaced by new generation MM200 Motor Controllers. The Multilin MM200 is a digital motor protection and control system, designed for low voltage motor applications that integrates protection, control and multiple communication protocols in a rugged compact device. Easily integrated into new and existing control system architectures, the Multilin MM200 provides comprehensive low voltage motor protection and communications for all types of motor protection applications. Key Benefits Flexible protection, control, and communication options to suit low voltage motor applications Small footprint designed specifically for IEC and NEMA MCC applications Integrated pushbuttons and LED indicators reduce external components and wiring Flexible DIN rail mounting Multiple communication protocols allow simple integration into monitoring and control systems. Optional control panel provides local control Universal device for all motor power ratings No CTs required for less than 5A motor ratings Thermistor input to monitor the ambient or motor temperature Support for Hand Held Display (HHD) that provides a graphical color local interface allowing local operators to view and change setting files and quickly access relay diagnostic information Applications Low Voltage Three-Phase Motors MCC and standalone Panel Mount Applications IEC and NEMA Motor Control Center (MCCs) Process control applications System architecture requiring multiple simultaneous communications FVNR, FVR, two speed Protection and Control Protection and Control Motor Thermal Model Undercurrent & Current Unbalance Acceleration Time, Sensitive Ground Fault Built-in Starter Logic; FVNR, FVR, Two-Speed Auto / Manual Control, Configurable Inputs Power Fail Restart Metering & Monitoring Current, Motor Loads, Thermal Capacity Motor Running Time, Cause of Trip, Total Number of Trips 1A / 5A combined CT inputs Communications Networking through RS485 ModBus RTU, DeviceNet & ProfiBus ODVA Certified DeviceNet and ProfiBus Network powered by external (preferred) or internal power Simultaneous Communications Easy Integration with MM200/MM300 Setup Program GE ViewPoint Monitor TM Software for Easy Motor Controls Connect to the Graphical Control Panel HHD EnerVista Software Simplify setup and configuration Strong document archive and management system Simplify full-featured monitoring and data recording Strong maintenance and troubleshooting tool Seamless integration toolkit

Specifications - LM10 & MM200 DEVICE DESCRIPTION LM10 MODULAR MOTOR CONTROLLER MM200 MOTOR CONTROLLER BASIC SPECIFICATIONS Protection Class NEMA class 10, 15, 20 and 30, hot and cold 10, 15, 20, 30 (selectable) Starter Types FVNR, FVR, RV, 2S1W, 2S2W, custom FVNR; FVR & Two Speed Ambient Compensation No Yes with Thermistor Biasing Phase Loss Protection Yes Yes Phase Unbalance Yes Yes Ground Fault Yes Yes Self Powered Power from Starter CPT For AC Inputs: No (Power from starter CPT recommended) For DC Inputs (Low Power Option): Yes FLA Adjustable Range 0.05 to 8 CT Primary (3200.0 A max.) 0.5 to 1000 FLA in steps of 0.1 Reset Mode Manual & Automatic Manual & Automatic Trip Test Manual & Automatic Manual & Automatic Trip Indication Unit LEDs/User Interface - PDU/SCADA LED/User Interface/SCADA Operating Temp. Range Operating temp: 0 to 60 C Operating temp: -20 C to +60 C Storage temp: 30 to 80 C Humidity: up to 95% noncondensing Communications DeviceNet only Modbus RTU Modbus RTU + Profibus DP Modbus RTU + DeviceNet PLC Compatible Contacts Yes Yes Aux. Contacts 4 on-board Form-C Relays with NEMA C150 Pilot Duty Ratings Two Form A Types for Controlling & One Form C Mounting Flexible Three Different Mounting Options Din-Rail Panel Mount Notes: The LM10 Motor Controller System supported Voltage Signal Based Sensor CT Packs using two sets of CTs connected to separate CT terminals. In MM200, this is achieved by connecting two separate sets of CTs to the same CT Terminals. MM200 does not support CT sensor packs. MM200 Relay Options B: Basic Control Panel L: 24 VDC H: 60-300 VAC 1. RS485 Modbus RTU + DeviceNet Slave 2. RS485 Modbus RTU + Profibus DP Slave HHD (Hand Held Display): a graphical control panel used to control, monitor, and enter setpoints manually For further details on the MM200 Motor Management System, visit GE Multilin s web site at www.gemultilin.com where you can download the MM200 brochure with complete order codes, the MM200 instruction manual, and details about the EnerVista suite of setup and monitoring software tools. 2 GEGridSolutions.com

Specifications - LM10 & MM200 DEVICE DESCRIPTION LM10 MM200 PROTECTION Thermal Model (49) Custom programmable overload curves IOC, Ground (50G) TOC, Phase (51P) Jam Protection (51R) Stall Protection Phase Overvoltage (59P) Phase Under-voltage (27P) Power Loss/Under-voltage Auto-restart (27/79) Power Failure Restart (PFR) is available Undercurrent/Under-power (37) Current Unbalance (46) Frequency (81) Power Factor (55) Reduced Voltage Start (19) Remote Start/Stop via Communications Start Inhibit Emergency Start Two-speed motor protection DEVICE DESCRIPTION LM10 MM200 CONTROL Remote Display Power Supply AC Only AC/DC CT Inputs Designed for 5 Amp; Adjustable to 1 Amp for Voltage based Current Sensor Packs 5/1 A Self-Test Failure Contact Contact Inputs 7 6 LCD Display with Keypad - Yes with HHD Basic Control Panel (No Writing) User-Programmable LEDs Thermistor Inputs Event Recorder (in form of trip counter) MONITORING & METERING SPECIFICATIONS Last 10 trips Power Factor Thermal Capacity Used Last trip Current - RMS Current - Unbalance Current - Ground Leakage Voltage - RMS Power - Apparent, Real, Reactive Active Active Learned motor data ENVIRONMENT & MECHANICAL SPECIFICATIONS BASIC Control Power LCD Display 120 V AC 4 line 16 character small display with a keypad (H) 65-300 V AC / 84-250 V DC (L) 24 V DC 1. none 2. optional HHD 3. Basic Control Panel available Operating Temperature Range - Minimum C Operating Temperature Range - Maximum C Humidity COMMUNICATION SPECIFICATIONS 0-20 60 60 Up to 95% noncondensing Up to 95% noncondensing Interface Program OVERLOAD CURVE COMPARISON LM10 (NEMA curve) MM200 (curve multiplier) Class 10 Classs15 Class 20 Class 30 4 6 8 12 RS232 Port RS485 Port Communication Baud Rates ModBus Protocol 125kbps; 250kbps or 500kbps 9600; 19200; 38400; 57600 or 115,200 ModBus User Map Profibus Port For a feature comparison of all available GE Multilin relays, visit our selector guide at: www.gegridsolutions.com/multilin/selector Device Net USB Port - Yes with HHD GEGridSolutions.com 3

Specifications - LM10 & MM200 LM10 Dimensions Existing LM10 relays may be mounted using a mounting plate, mounting bracket, or door mount cutout. MM200 Dimensions & Mounting MM200 relays are DIN rail mounted, as shown. The DIN rail conforms to EN 50022. SNAP IN THE DIN CLIPS (QTY:4) FOR DIN RAIL MOUNTING 3.100 (78.7 mm) 4.437 (112.7 mm) 3.542 (90 mm) 4 GEGridSolutions.com

Terminal Mappings LM10 to MM200 LM10 # LM10 DESCRIPTION MM200 # MM200 DESCRIPTION Control Connection Terminals Sensor Pack Inputs Upper Signal Row Lower Signal Row Sensor Pack - 01 Sensor Pack - 02 1 Live Connection - 120 V AC PSU - L PSU 2 Neutral Connection PSU - N* Voltage Terminal - Phase A 3 Switch Input - STOP A2 to A5 - (Any Input) Switch Input 4 Switch Input - RESET A2 to A5 - (Any Input) Switch Input 5 Switch Input Common NR* Neutral Return 6 Relay 1 - Normally Open - Run C1 Contact Output 1 - Normally Open - Run 7 Relay 1 - Common - Run C2 Contact Output 1 - Common - Run 8 Chasis Ground PSU - GROUND* Neutral Terminal - Control Power 9 Relay 2 - Normally Open - Run C3 Contact Output 2 - Normally Open - Run 10 Ground Fault Relay - Normally Closed Not Required in MM200 MM200 uses Contact Output 1 or 2 based on the Settings 11 Relay 2 - Common - Run C4 Contact Output 2 - Common - Run 12 CT Input - Set 1-5 Amps - Phase B B5 Phase B - 5 Amps or 1 Amp - CT Terminal 13 CT Input - Set 1-5 Amps - Phase A B3 Phase A - 5 Amps or 1 Amp - CT Terminal 14 CT Input - Set 1-5 Amps - Phase C B7 Phase C - 5 Amps or 1 Amp - CT Terminal 15 CT Input - Set 1-5 Amps CT - Common B4, B6 & B8 Phase A, B & C CT Commons respectively 16 Ground CT - 1 Amp Secondary or 20 : 0.2 Amp Type Only 50:0.025 CT Connection is required MM200 supports 50:0.025 Type CBCTs 17 Switch Input - Auxiliary 2 A2 Switch Input - Contactor B - Feedback 18 Switch Input - Auxiliary 1 A1 Switch Input - Contactor A - Feedback 19 Switch Input - Run 2 A2 to A5 - (Any Input) Switch Input 20 Switch Input Run 1 A2 to A5 - (Any Input) Switch Input 21 Switch Input - DedviceNet Control Not Required in MM200 Order Code based feature supported by Settings 22 Ground Fault Relay - Normally Open Not Required in MM200 MM200 uses Contact Output 1 or 2 based on the Settings 23 Ground Fault Relay - Common Not Required in MM200 MM200 uses Contact Output 1 or 2 based on the Settings 24 Programmable Relay - Normally Open C5 Contact Output 3 - Normally Open Contact 25 Programmable Relay - Normally Close C7 Contact Output 3 - Normally Close Contact 26 Programmable Relay - Common C6 Contact Output 3 - Common Terminal 27 CT Input - Set 2-5 Amps - Phase B B5 Phase B - 5 Amps or 1 Amp - CT Terminal 28 CT Input - Set 2-5 Amps - Phase A B3 Phase A - 5 Amps or 1 Amp - CT Terminal 29 CT Input - Set 2-5 Amps - Phase C B7 Phase C - 5 Amps or 1 Amp - CT Terminal 30 CT Input - Set 2-5 Amps CT - Common B4, B6 & B8 Phase A, B & C CT Commons respectively 31 No Connection Not Required in MM200 Not Required 32 Ground CT - 1 Amp Secondary or 20 : 0.2 50:0.025 CT Connection is MM200 supports 50:0.025 Type CBCTs Amp Type Only required 1 Phase A - CT 2 Phase B - CT 3 Phase C - CT 4 Phase A - CT - Common 5 Phase B - CT - Common 6 Phase C - CT - Common 1 Phase A - CT 2 Phase B - CT 3 Phase C - CT 4 Phase A - CT - Common 5 Phase B - CT - Common 6 Phase C - CT - Common Not Supported in MM200 MM200 does not accept Voltage Input based Sensor Packs Note: * Indicates MM200 retrofit terminals selected under the assumption a CPT with Non-Polarity Secondary (Neutral) is grounded and fed to both Neutral and Ground Terminals of the LM10 Relay. GEGridSolutions.com 5

GE s Projects and Professional Service Professional Services Offerings and Activities GE has developed a Professional Services Process. The process is comprehensive, application specific, and includes customer collaboration for successful project implementation. GE s Professional Services Process is based on a common set of building blocks, utilized and tailored for each customer s unique communication network requirements. While GE uses well documented and repeatable processes, we realize that flexibility is also key to accommodate our customer s specific requirements and needs unique to their environment. Dedicated Project Management GE assigns a project manager at the beginning of each project to lead the team throughout the project lifecycle. The project manager acts as an extension of the customer s team to coordinate and drive all aspects of the project to a successful outcome. Global Capabilities GE s dedicated engineering teams are located in regions around the world and bring a wealth of international experience to every project. Customers benefit from GE s local systems subject matter experts who drive compliance with regional/local requirements ensuring our customers business and technical objectives are met. GE has an excellent track record in planning, executing and delivering a broad range of projects. GE s systems subject matter experts work in state-of-the-art facilities that include design, research and development, manufacturing and testing capabilities. Customer are supported with 24/7 field and application support. Conventional Control Systems Packaged Solutions Protection Panels Projects RTU Centric Panel Engineering Digital Control Systems Substation Automation Engineering Substation Automation Projects Integrated Energy Management Systems Microgrids Technical Expertise Technical Services Standard pre-designed protection and RTU panels Design to specification protection and control panels Legacy retrofit solutions Protection and Control System design Drop in Control House Automation and Protection project design and build Local HMI through complex substation SCADA Solutions WAMS / Synchrophasers Implementation Integrated Energy Monitoring Systems implementation and custom applications RTU upgrade engineering Power system studies System setting studies Real Time Digital Simulation and modelling Complex system design (Fast Load Shedding, Remedial Action Schemes, Synchrohpasor and Microgrid Project Design) NERC Compliance Support Modified field drawings Setting and configuration Monitoring & Diagnostic, Process Bus Consulting Services Training Commissioning & Field Service Maintenance Contracts Life Cycle Management Services Designed, build and tested in house with customer settings if needed 6 GEGridSolutions.com

MM200 Typical Wiring Digram GEGridSolutions.com 7

LM10 Typical Wiring Diagram Multilin LM10 Motor Protection System GEGridSolutions.com IEC is a registered trademark of Commission Electrotechnique Internationale. IEEE is a registered trademark of the Institute of Electrical Electronics Engineers, Inc. Modbus is a registered trademark of Schneider Automation. NERC is a registered trademark of North American Electric Reliability Council. ANSI is a registered trademark of American National Standards. GE, the GE monogram, Multilin, FlexCurves and EnerVista are trademarks of General Electric Company. GE reserves the right to make changes to specifications of products described at any time without notice and without obligation to notify any person of such changes. Copyright 2017, General Electric Company. All Rights Reserved. GEA-32002-(E) English 171120