vlocdm2 Rx & Loc-150Tx Data Sheet V1.6

Similar documents
vlocml2 Rx Data Sheet V1.6

vloc3-pro Technical Specifications V1.0

vcam-5 Type-M2 System Data Sheet V1.2

vcam-5 Mini System Data Sheet V1.0

INVITATION TO BID. (This is not an order.)

vcam-6 Technical Specifications V1.1

vcam-6 Technical Specifications V1.1 vcam-6 Technical Specifications V1.1 Page 1 of 7

Innovative Industrial Solutions, Inc Skyline Drive Russellville, AR Phone (479) Fax (479)

MZ Line tester. Contents. Reference: Date: October Version: 3

CRIBS Installation and User Guide

BT-R900. Bluetooth GPS Receiver. User s Manual. Date: April 2006 Version: 2.1. All Rights Reserved

Quinta MU 31 FEATURES. Digital Wireless Delegate Microphone Unit Order #

HPA4202 1/5. 2-Channel High Power Multi-Impedance Amplifier. General Description. Features. Applications. AtlasIED.com. HPA4202 Front.

Circuit Breaker Analyzer & Timer CAT-P

innovative technology to keep you a step ahead

BlueSet Wireless Headset Interface User Guide

Circuit Breaker Analyzer & Timer CAT-P

innovative technology to keep you a step ahead In-Home Leakage Evaluation System

Instruction Manual. G.R.A.S. 12AA 2-Channel Power Module with gain, filters and SysCheck generator. LI April 2015

DVI KVM Switch user manual Model

Micro-Ohmmeters. Digital 10A. Models 6240 & Measure low resistance with high accuracy. Selectable test current and resistance ranges

MICHIGAN DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION FOR ACCESSIBLE PEDESTRIAN SIGNAL SYSTEM

Model R5005. Instruction Manual. True RMS Industrial Multimeter. reedinstruments. www. com

Digital Clamp-on Meter Instruction Manual

Marshall Electronics. Operating Instructions. Warranty. AR-AM4 Analog Audio Monitor

USB VGA KVM Console Extender w/ Serial & Audio Over Cat5 UTP ft

WaveMark SmartWand Plug Kit

E101 - Strain Gauge Transducer Display Module. Contents

Voice Pager Supports P25 Radio Systems Now!

Click Desktop Kit. Click Desktop Kit

FG-3000R Digital Force Gauge Operation Manual

MCCB-500 MOLDED-CASE CIRCUIT BREAKER TESTER

Marshall Electronics. AR-AM4-BG Analog Audio Monitor. Operating Instructions

705 INSTALLATION MANUAL

Technical Data FLIR i7

OTS-600 Series Optical Sources, Meters, Testers and Kits with Data Storage Capabilities

5.6" Multi-function Monitor

Bluetooth Stereo Headset icombi TM AH20 User s Manual

10A Micro-Ohmmeter Model 6240

VIAVI Seeker D Lite. Data Sheet. Shielding Integrity Testing Kit A Trilithic Series Leakage Solution. Overview. Key Features. In-Home Leakage Detector

IFR 6000 Transponder/DME Ramp Test Set

FG-7000 Digital Force Gauge Operation Manual

3.5 TFT LCD CCTV Service Viewer with Wristband LCD35SV

German Cathodic Protection

Circuit Breaker Analyzer & Timer CAT-P

Digital Signal Level Meters. IT-910C Series. User Manual

RetroSign GRX-7 1. MEASUREMENT PARAMETERS:

Fortuna Slim Bluetooth GPS Receiver

High Definition VideoScope

HMEC Instructions for use

FLIR T Imaging and optical data. Minimum focus distance. Minimum focus distance with MSX. Spatial resolution (IFOV)

REDCAT ACCESS DETAILED SPECIFICATIONS

mxr Wireless Optical quick install guide Model MAN QIG

HT-1A Dual Band CW QRP Transceiver. User Manual

Technical Data FLIR E5

Hand-held thermometer Model CTH7000

T2 863 Transmitter, R2 863 Receiver 863 MHz Portable FM Listening System - Europe

F1000 User's Manual. (Version: V1.01)

FG-3000 Digital Force Gauge Operation Manual

Seeker HL In-Home Leakage Detector. User s Guide

FG-7000L Digital Force Gauge Operation Manual

TTC Series Torque Tool Tester Operation Manual

MEASURING AND TESTING INSTRUMENTS

DM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER

CONTENTS ... S-62 OVERVIEW POSITIONING GETTING STARTED... 6 HOW TO USE YOUR S OTHER FUNCTIONS TECHNICAL SPECIFICATIONS...

PDW30 Point-To-Point Wireless Bridge

Andover Continuum. Power Supplies with or without UPS

DH GHz Digital Wireless Headphone. User s Manual. Please read before using the equipment. Please visit for details.

DLT 300, DLR 360 Digi-Wave 300 Series Digital Transceiver and Receiver

CU 4005 CDS 4000 Central Control Unit for 50 Conference Units

Simplified information where and how you want it.

ARA FTS Flow Calibrator. Operation Manual August 1, 2016

Electrical Specifications. Input Current 115 VAC: 1 A max. 230 VAC: 0.5 A max.

Model: BluComm-OTH. All rights reserved. 0

Tinytag Thermohygrometer User Guide

Digital Video Inspection

DELORME PowerPack for Earthmate GPS with Bluetooth GPS 9822

FLIR VS70: Wireless General Purpose Videoscope Combo

Kenai Peninsula Borough School District Formal Bid #

Windows-Based Terminal. TK-3550 H.W. Manual

Package Contents Bluetooth Keyboard Charging Cable (If using the Apple 30 pin charging interface, this is not needed)

Features Ultra-light, compact and thin form factor Available in your choice of high-gloss black or high-gloss white DATA SHEET

SmartPro LCD 120V 1200VA 700W Line- Interactive UPS, AVR, 2U Rack/Tower, LCD, USB, DB9 Serial, 8 Outlets

Single Phase Systems-North American PC125/PC420 Series

BORESCOPE INSTRUCTIONS INSPECTION CAMERA RANGE RBS100 RBS200 RBS300. Retain these instructions for future reference

Really Performs! Here is a Hand-Held Data Logger that Royalton Rd. Cleveland, OH USA Tel: (440) Fax: (440)

EZ Bridge G Product Guide

BT-Q818XT Quick Installation Guide

Model OI-9100 Signal Strength Meter The View

Micro Ohmmeter RMO200G

Bluetooth Hands-free Car Kit S-61. Quick Start Guide

DPA 7000 PATENTS PENDING TELEPHONE AND LINE ANALYZER

EtherScope Series II Network Assistant

Communication over Modbus protocol Connection with multiple controllers Application upgrade by using an SD 1) card or a USB stick

HCS-3600 / 3602 / 3604 Laboratory Grade & High RFI Immunity Switching Mode Power Supply with Rotary Encoder Control

Marshall Electronics. Operating Instructions. Warranty. AR-AM1 Analog Audio Monitor

Marshall Electronics. AR-AM1 Analog Audio Monitor. Operating Instructions

Talk-N-Tracef Communication and Tracing Set. User's Guide.

Bearing (Shock Pulse) Condition Analyzer -110

NIDEC-SHIMPO INSTRUMENTS

Transcription:

A. vlocdm2 Typical Applications Description Pipeline defect mapper receiver and transmitter Uses - Locating and pinpointing coating defects on buried pipelines - Profiling the CP current distribution on a pipeline network - Identification of short circuits from pipelines to other structures - Long distance pipeline location - Transmitting active signals for the location of coating defects on buried pipes B. vlocdm2 Receiver Assembly Construction - Carbon fiber reinforced antenna tube Weight Dimension Display Type Receiver Antennas - High impact thermoplastic (ABS) injection molded housing - Removable ABS foot molding containing magnetometer 6lbs (2.7kg) 11.7in(L) x 5.5in(W) x 30in(H) (262mm x 122mm x 750mm) Sharp TFT LCD ¼ VGA color display, 3.52in (89mm) 2 x Peak antennas, 1 x null antenna, 1 x compass antenna, 1 x magnetometer Batteries - Rechargeable Lithium-ion batteries with 100-240V AC mains charger - Replaceable (6 x standard Alkaline AA batteries) batteries can be used when required Battery Life - Alkaline typically 8 hours intermittent use at 70ºF (21ºC) - Lithium-ion typically 24 hours continuous use at 70ºF (21ºC) (with full backlight turned on). Re-charging cycles approx. 500 times life cycle. Battery life varies with temperature. Bluetooth - Plug and play custom Bluetooth interface External Connectors - 1 x Socket for USB accessories & analogue accessories - 1 x Mini USB socket for data transfer / programming - 1 x Socket for battery charger - 1 x Standard USB (Memory stick) socket for data transfer (Future feature) Approvals - Complies with European standard CE (Directive 99/5/EC) EN 55011 EN 61000-4-2: A1 & A2 EN 61000-4-3 EN 61000-4-8: A1 ETSI EN 300 330-2 ETSI EN 301 489-1 ETSI EN 301 489-3 Standard Accessories - Bluetooth Module - Holux GPS (Bluetooth connectivity) - Transmitter: Loc-150Tx and connection leads - A-frame - Complies with FCC Rules Part 15 CFR 47 part 2 CFR 47 Part 15 Updated: June 2014 Page 1 of 8

- USB data cable - 100-240V AC mains receiver charger (for Lithium-ion battery) - Soft carry bag (inclusive of accessories bag) - User handbook - Desktop application (desktop programming data management) User selectable configuration management Replication of user configuration Accessories (Optional) - Remote Antenna USB - Sondes (waterproof self-contained transmitters for use in pipes & ducts) D18-33-SR44-0.75in(Dia.) x 3.1in(L) (18mm x 80mm), 33 khz, range 15ft (4.5m), 2 x button cell batteries D38-33-AA 1.5in(Dia.) x 4.1in(L) (38mm x 105mm), 33 khz, range 16.3ft (5m), 1 x AA battery D38-09-AA 1.5in(Dia.) x 4.1in(L) (38mm x 105mm), 9.82 khz, range 16.3ft (5m), 1 x AA battery D38-83-AA 1.5in(Dia.) x 4.1in(L) (38mm x 105mm), 83 khz, range 16.3ft (5m), 1 x AA battery D64-33-6LR61 2.5in(Dia.) x 7.3in(L) (64mm x 186mm), 33 khz, range 26ft (8m), 1 x 6LR61 battery D64-09-6LR61 2.5in(Dia.) x 7.3in(L) (64mm x 186mm), 9.82 khz, range 26ft (8m), 1 x 6LR61 battery D64-83-6LR61 2.5in(Dia.) x 7.3in(L) (64mm x 186mm), 83 khz, range 26ft (8m), 1 x 6LR61 battery D23F-512-AA / D23F-640-AA 1in(Dia.) x 18in(L) (23mm x 456mm), 512Hz or 640Hz, range 20ft (7m), flexible Sonde in 3 sections for use in cast iron pipes as well as non metallic pipes, 1 x AA battery C. vlocdm2 Receiver Operational Information Displayed - Signal strength - moving bar graph & numeric value - Mode indication ( Peak, Null and Peak with proportional left/right arrows location) - Proportional left/right indication - Compass: line direction indicator - vlocdm2 signal direction - Plug and play automatic recognition of accessories - Accessory specific custom screen - Line location - depth & current measurement - Measurement of vlocdm2 mapping current - Gain level (in db) - Battery condition - Speaker volume - Operating frequency - Bluetooth and GPS status - Configuration menu & submenus Updated: June 2014 Page 2 of 8

Configuration - Start up screen product and USB accessories software revision - Customer definable start up screen - Distance from last reading (when GPS facility activated) - Log number - Real time vlocdm2 mapping and on screen graphing (walk back feature) - Walk back feature giving physical position on graph allowing the user to walk back to a point of interest. - Real time A-frame fault mapping and on screen graphing Intuitive setup menu enables user to configure vlocdm2 receiver or use MyLocator2 application to configure vlocdm2 receiver: 1. Setup frequency selection to toggle by f pushbutton 2. Setup location mode selection to toggle by M pushbutton 3. Units of measure (feet/meter) 4. Power and radio modes 50Hz or 60Hz environments 5. Sound (Pitch) normal/modulated 6. Language 7. Continuous depth/current options 8. Loudspeaker level 9. Backlight 10. Bluetooth pairing if fitted Internal Data Logging - At least 1000 records. Operating Frequencies - All parameters stored at each location including Depth, Current, Mode, Gain Setting, and Frequency. - If connected to GPS (via Bluetooth) data also recorded with coordinates and date time. - Files can be saved as.kml,.txt,.xls,.shp, csv - Data transfer program MyLocator2 available from www.vivax-metrotech.com vlocdm2 (magnetometer) frequencies: 3Hz/6Hz, 4Hz/8Hz vlocdm2 related locate frequencies: 98Hz, 128Hz, 512Hz, 640Hz Configurable frequencies from 16Hz to 200 khz. Operating Modes - Peak Vivax-Metrotech Corporation retains the right to make additions or deletions to this list at any time Gain Control Performance Using Single Undistorted Signal Source - Null - Peak with proportional left/right arrows Manual gain using + or - with one touch to return to center (60% of FSD) Locate pinpointing accuracy: - up to 9ft (3m) 3% of depth - over 9ft (3m) 5% of depth Depth measurement accuracy: - 3% of depth Current measurement accuracy: Updated: June 2014 Page 3 of 8

Compatible With Transmitter - 3% of actual current up to 9ft (3m) - 5% of actual current over 9ft (3m) Depth range: - Dependent on strength of signal radiating to locator Generally up to 15ft (5m) Loc-150Tx, Loc-10Tx, Loc-5Tx, Loc-1Tx Updated: June 2014 Page 4 of 8

D. Loc-150Tx Transmitter Assembly Construction Weight Dimension Display Type High impact ABS 27.5lbs (12.5kg) 16.7in(L) x 10.3in(W) x 12.9in(H) (425mm x 262mm x 328mm) Monochrome dot matrix display 2.4in x 1.3in (60mm x 32mm) Power Supply Cathodic Protection (nominally 26V - 60V DC) (max 14A) External Connectors Output Protection Approvals Standard Accessories (Supplied With Transmitter) 100 250V AC mains power (max 4A) or 12V DC external supply or higher (output power is limited when using 12V DC) (max 8A) 100 250V AC mains input - three pin Multi-Con-X connector (Male) DC Input - two pin Multi-Con-X connector (Male) Transmitter output - two pin Multi-Con-X connector (Female) Fuse sockets mains input fuse (5A, 250V), output fuse (10A, 250V) Output fuse protected against accidental connection to up to AC/DC 250V Complies with European standard CE (Directive 99/5/EC) (Pending) EN 55011 EN 61000-4-3 EN 61000-4-2: A1 & A2 EN 61000-4-8: A1 ETSI EN 300 330-2 ETSI EN 301 489-1 ETSI EN 301 489-3 Complies with FCC Rules Part 15 (Pending) CFR 47 part 2 CFR 47 Part 15 1 x direct connection lead (with two cables each 10ft(3.5m) long with crocodile clips) 1 x DC input lead (with two cables each 10ft (3.5m) long with crocodile clips) 1 x 9ft (3m) mains input lead E. Loc-150Tx Transmitter Operational Information Displayed Signal Application Modes Transmitting Frequencies (Varies By Country & Market) Output Frequency Output Current setting Output Current Output Voltage (info menu) Operating Temperature (info menu) Direct connection mode only- applies signal directly to the cable by clipping one output lead to the pipe, the other to an independent ground or anode bed. 98Hz, 128Hz, 512Hz, 640Hz, 3Hz/98Hz, 3Hz/128Hz, 4Hz/98Hz, 4Hz/128Hz; ELF1-3Hz/6Hz/98Hz; ELF2-3Hz/6Hz/128Hz; ELF3-4Hz/8Hz/98Hz; ELF4-4Hz/8Hz/128Hz; 3Hz/6Hz/512Hz; 3Hz/6Hz/640Hz; Updated: June 2014 Page 5 of 8

Transmitting Mode Power Output Output Voltage Output Current Controls Compatible With Receivers 4Hz/8Hz/512Hz; 4Hz/8Hz/640Hz Other multiple frequencies in the range of 3Hz to 2kHz available upon request. Powered by AC: 150W Powered by DC: 12-28V, 50W; > 28V, 150W Maximum output voltage = 120V RMS Maximum output current = 4A RMS with up to 2 frequencies. Output limited to 3A RMS with 3 simultaneous frequencies. 2 Rotary/Push control knobs to select: Frequency Output level Information ACTIVE/STANDBY pushbutton One On/OFF pushbutton vlocdm & vlocdm2 F. Sensitivity Mode 3Hz DM Mapping Frequency 50Hz/ Power Mode Radio Mode 512Hz / 640Hz Sensitivity at 3.2ft (1m) 1 ma 7.5 ma 20 μa 400 μa 8 khz 40 μa 32 khz and Above 25 μa G. Environmental Temperature Range Operating : - 4ºF to 122ºF (-20ºC to 50ºC) Storage : -40ºF to 140ºF (-40ºC to 60ºC) Weather Proof IP54 and NEMA 4 Shipping Weight vlocdm2 Receiver: 12lbs (5.5kg) Loc-150Tx Transmitter: 44.1lbs (20kg) Shipping Dimension vlocdm2 Receiver: 13.0(L) x 8.7in(W) x 32.7in(H) (330mm x 220mm x 830mm) Loc-150Tx Transmitter: 21.7in(L) x 15.2in(W) x 18.3in(H) (550mm x 385mm x 465mm) H. Warranty Warranty 12 months Updated: June 2014 Page 6 of 8

I. Upgrade Software Software can be upgraded using a PC with USB port. Programs & locator software will be available via email. Additional frequencies will be available free of charge. J. A-frame Construction Sensitivity Weight Dimension Weather Proof Shipping Weight Shipping Dimension Carbon fiber 2MΩ 4.0lbs (1.80kg) 28.3in(L) x 25.2in(W) x 1.6in(H) (720mm x 640mm x 40mm) IP54 9.9lbs (4.50kg) 31.5in(L) x 27.8in(W) x 4.5in(H) (800mm x 705mm x 115mm) K. Holux Bluetooth GPS Overview The M-1200 high performance Bluetooth TM GPS Receiver which featured with: - Dual interface (Bluetooth + GPS - mouse) - Compatible with Bluetooth TM Serial Port Profile (SPP) completely - Built-in rechargeable Lithium-ion battery without external power supply Weight - 0.07lbs (30g) Dimension - 2.63in(L) x 0.9in(W) x 0.63in(H) (67mm x 23mm x 16mm) Specification - Tracks up to 32 satellites - Receiver: L1, 1575.42 MHz - C/A code: 1.023 MHz - Update rate: 1Hz - Antenna type: built-in patch antenna - Minimum signal tracked: -159dBm - On/Off switch: slide switcher - Lithium-ion battery lasts for 15 hours of use. LED Indication - Bluetooth - Navigation update - Battery/charger status indication Temperature Range - Store Temperature : -4ºF to 140ºF (-20ºC to 60ºC) : -22ºF to 176ºF (-30ºC to 80ºC) (Without Lithium-ion battery) - Operation Temperature : 14ºF to 140ºF (-10ºC to 60ºC) Updated: June 2014 Page 7 of 8

L. Features Enhanced Features - Removable foot - Reduced size and weight with enhanced ergonomic design - Improved power management and Lithium-ion rechargeable batteries provide longer battery life - Auto detects batteries type (Lithium-Ion/Alkaline) and displays appropriate status. - Non-reflective display - Enable / Disable auto shut off mode - USB data Logging - Analogue channel - Overload protection Disclaimer: Product and accessory specification and availability information is subject to change without prior notice. Indepth Utility Solutions LLC 4100 Greenbriar Dr., Suite 240 Stafford, TX 77477 Phone: 281-969-8530 Email: info@indepthus.com Website: www.indepthus.com Updated: June 2014 Page 8 of 8