USB RS-485/422 Communication adapter virtual serial port ELO E211. Operation manual

Similar documents
USB RS-485/422 Communication adapter virtual serial port ELO E216. Operation manual

RS 232 to Fibre Optic Modems ELO E240, ELO E241, ELO E242. Operation manual

USB RS232 Communication adapter virtual serial port ELO E215. Operation manual

VirtualSCADA VSU-485G USB to RS422/485 Isolated Converter User Manual

Introduction & Specifications of Hi-Speed USB to Industrial Dual Ports RS-422/485 Adapter

USB to RS-485/RS-422 Interface Converter. User Manual

Introduction & Specifications of Hi-Speed USB to Serial Adapters

Product Manual. 2 Port USB to RS-422 /485 Optical Isolated Adapter. Coolgear, Inc. Version 1.1 March 2018 Model Number: USB-2COMi-Si-M

Installation Guide of Hi-Speed USB to Industrial I/O Adapter

W&T Manual Interface modules W&T

PCI Express 4-Port Industrial Serial I/O Cards

Installation Guide of Hi-Speed USB to Industrial Single RS-422/485 Adapter

Installation Guide of Hi-Speed USB-to-Optically Isolated RS-422/485 Adapter

RS-422A/485 Serial I/O Board with Isolation for PCI. Features. Cable & Connector (Option) Product Configuration List.

Commercial-grade Interface Converter User Manual

MODEL USB-COM-2SM USER MANUAL

Windows 8 / 7 CONTENTS. USB to RS-422 Converter. Part Number: USB FEATURES. 2 SPECIFICATIONS. 2 CONNECTIONS.. 3

Manual Industry Interfaces

Windows 8 / 7 CONTENTS. USB to RS-485 Converter. Part Number: USB FEATURES. 2 SPECIFICATIONS. 2 CONNECTIONS.. 3

USB-16COMi-M 16-Port RS-422/485 USB Serial Adapter User Manual. Features and Specifications. Power Supply

DATA CONNECT ENTERPRISE

ADAM-4510 RS-422/RS-485 Repeater ADAM-4510S Isolated RS-422/485 Repeater ADAM-4520 Isolated RS-422/485 Converter Startup Manual

User s Manual Printed Sep Rev 1.2

USB-COMi-TB USB to Industrial Single RS-422 / 485 Adapter Manual. Specifications and Features

This 4-port RS-422/485 Adapter is provided with an external switching power adapter in the package.

SB485. USB-RS485/422 converter. Isolation. Virtual serial port

Installation Guide of Hi-Speed USB to Octal RS-232/422/485 Adapter

TRP-C08M. USB To 4 RS232/422/485 Isolated Converter. User s Manual. Printed Jun Rev 1.0

3.1 I-7560 Pin Assignment and Specifications: Introduction

USB to RS-232/RS422/485. URK-228-I USB To Serial Operation Manual

USB to RS-232/RS422/485. US-101-I USB To Serial Operation Manual

TRP-C08. USB to RS232/422/485 Isolated Converter. User s Manual. Printed Sep.2014 Rev 1.4

K107A / K107B Half-duplex RS485 serial bus with 3-point insulation

EasySYNC Ltd. USB to Serial Converters Manual

TRP-C08S. USB to 1 RS232 and 1 RS422/485 Isolated Converter. User s Manual

Manual Fiber Optic Interfaces

USB to Single RS-422/485 Adapter - with optical isolation and surge protection (USB-COMi-SI)

MODEL USB-FLEXCOM4. USB to Four RS-232/422/485 Serial Ports and MODEL USB-COM232-4A USB to Four RS-232 Serial Ports USER MANUAL

MED102A. Industrial Serial to Single-mode Fiber Converter

TRP-C08S. USB To 1* RS232 and 1*RS422/485 Isolated Converter. User s Manual. Printed Jun Rev 1.2

CMU 100 RS485 to 7x, 6x, 5x, 4x Multimode Fiber Optic Star Coupler User Manual

INTRODUCTION 2 FEATURES. 2 SPECIFICATIONS. 2 PIN ASSIGNMENT 2 DB-9 DB-25 CONVERSION TABLE. 2 DRIVER INSTALLATION QUICK GUIDE.. 2

FCC Information. RoHS This product is RoHS compliant. SJ/T The following contains information that relates to China.

Serial Communication Converters & Adapters Instruction Manual

EasySYNC Ltd. USB to Serial Converters Manual

8 Port USB to RS- 232/422/485 Octal Adapter. Product Manual. Coolgear, Inc. Version 1.1 April 2018 Model Number: USB-8COMi-RM.

TRP-C08X. USB To 4 RS232/422/485 Converter. User s Manual

USB-COM Plus ISO (USB-COMi SI-M)

USBG-8COM-PRO 8-Port USB to RS-232, 422, 485 Auto Setup Adapter Manual. Features & Specifications. Specifications

I-7570 Serial To HART Converter

W&T. Universal Fiber Optic Interface Converter W&T. Manual. Universal FO Interface Converter. Model Release 1.0. Subject to error and alteration

USB to RS-422 / 485. US USB To Serial Operation Manual

Product Manual. USB to Optical Adapter Industrial Isolated RS- 232/422/485. Coolgear, Inc. Version 2.1 December 2018 Model Number: USB-COMi-Si-M

USB to RS-422/485 Serial Adapter

JetCon 1100 / User s Manual. USB to Serial Converter series. Version 1.0

ICF-1150 Series Quick Installation Guide

USB RS485 High Isolated Industry Converter Box for DIN Rail - product #248

ICF-1150 Series Quick Installation Guide

RS-485 module. Data sheet. for electricity meters

Product Selection Guides Serial Communication PCI Express Boards Multiport Serial Universal PCI Boards Boards ISA Boards

Integrity Instruments Application Notes. Release 1

205 CPU NETWORK ADAPTER F2-UNICON

Model:UT-8814 USB/RS-232 Commercial interface converter. Instruction Manual

TCF-142 Quick Installation Guide

MEV Limited USB232/485 INSTRUCTION MANUAL

Korenix JetCard Series Multiport Serial Card/Ethernet Switch Card User s Manual

I-7560U/7561U/7563U. User Manual WARRANTY WARNING COPYRIGHT TRADEMARKS CONTACT US

CMU 100 Multimode Fiber Optic to Singlemode Fiber Optic Converter User Manual

ICD105A 1008 page 1/ r001 ICD105A. Industrial RS-232 to RS-422/485 Converter

TRANSDUCER T4311, T4411

ABB Drives. User s Manual Modbus Adapter Module FMBA-01

Industrial Media Converters

General Specifications. P2-SCM Serial Communications

TRP-C08 User s Manual

Bluetooth to RS-232&RS422/485. EX-9132B/BI Bluetooth Adapter Operation Manual

8S RS232/422/485 Combo to USB2.0 Module Box Installation Guide

USER S MANUAL SI-700 SI EIA-232/ EIA-485 INTERFACE JUL / 05 SI-700 VERSION 1 FOUNDATION

Serial to Fiber Optic Converter Technical Guide

Chapter 1 Introduction Features Getting Help Chapter 2 ICB Architecture Layout and Components...

ADA User manual ADA RS-485 / RS-422 to RS-232 Converter. 1 io_ada-4010_v3.22_en. Copyright CEL-MAR sp.j.

User Manual VScom PCI Cards VScom Industrial Card

FlexMulti Setup Guide

Chapter 2 ICB Architecture Chapter 3 Board Components GPIO Interface RS-232 Interface RS-485 Interface...

NCOM SERIAL DEVICE SERVER 4XX SERIES USER S MANUAL

R507 I.S. Interface Module User Manual

Channel Digital Input Module 24 V DC High-side switching

CMU 100 RS232 to Singlemode Fiber Optic Converter User Manual

ADAM Fiber Optic to RS-232/422/485 Converter

FOURSTAR PROFIBUS HUB. FS-PBHUB-4 FS-PBHUB-6 User Manual

ME500A BLACK BOX SPECIFICATIONS: BOTTOM OF UNIT INTRODUCTION: CONFIGURATION: Async Sync Industrial Line Driver PWR TX RX RTS CD. DB25 Female Conn.

HDLC-PCIE. Synchronous Serial Card. Rev. Dec 22, Datasheet. Website:

Serial to Fiber Optic Converter

SER-4485-SI-M USER S MANUAL

Wiring Section 3-3. NQ-Series communication ports support various types of (serial) communication.

Media Converters. Media Converters. Product Selection Guides

TRP-C06H User s Manual

Serial Communications Accessories SITRANS RD200/300. Operating Instructions 05/2013 SITRANS

ADA-I9140. User manual ADA-I9140. USB to RS-485 / RS-422 converter. 1 io_ada-i9140_v3.24_en. Copyright CEL-MAR sp.j.

Interface RS485-TTL CODE: INTR. v.1.0 EN* Edition: 3 from

IC-485S /IC-485SI. If anything is damaged or missing, contact your dealer.

Transcription:

USB RS-485/422 Communication adapter virtual serial port Virtual IDLE ECHO ON OFF COM to Fiber Optics through USB ELO E211 Operation manual

2 ELOE211ZKE001

1.0 Introduction 4 1.1 Use of the converter 4 2.0 Operation principles 4 3.0 Installation 4 3.1 USB interface connection 5 3.2 RS-485 Installing 5 3.3 RS-422 Installing 5 3.4 Importance of terminators 5 3.5 Ground potentials differences elimination 6 3.6 Adapter setting 6 3.7 Installing driver 7 3.8 Installing virtual port under Windows XP 8 3.9 Installing driver for direct access 8 3.10 Virtual port properties setting 8 3.11 DLL Library use 9 4.0 Specification 9 4.1 Parameters 9 4.2 Other 9 5.0 Testing 9 6.0 Troubleshooting 10 7.0 Ordering information 10 3

1.0 Introduction The USB interface is preferred to the COM port with RS-232 interface in personal computer technology. To connect the peripheral devices of the RS-232 interface, the USB/RS-232 adapters along with the driver are applied to create so-called virtual COM on the PC. ELO E211 is a device which converts virtual COM to the asynchronous line of the symmetric signal via the USB interface. The signals transmission to the duplex RS-422 interface allows the range and the transmission interference immunity to increase. The signals transmission to the half-duplex RS-485 interface allows the range, communication partners number and the transmission interference immunity to increase. 1.1 Use of the converter The converter increases transmission immunity against electrical disturbance and isolates both interfaces USB / RS-422 hence it is intended to be used in the environments where lightning over-voltage is not necessary to be considered. To lead the RS-422 link cable outside buildings, it is necessary to provide additional overvoltage protection on the input points. The adapter allows the transmission rate up to 1 Mbps. This maximum attainable rate decreases due to the line length and/or its impedance growth. Recommended maximum line length is 1200 m at the rate of 9600 bps. 2.0 Operation principles The adapter converts the RS-422 or RS-485 interface to the USB interface, transmits TxD and RxD signals. The RS-485/422 interface is taken out onto the bus. RS-485 interface is used to the communication of up to 32 partners in one twisted pair. The transmission is half-duplex that means switching on the RS-485 transmitter only during its own transmitting to allow other communication partners to transmit. RS-422 interface is mainly designed for two devices communication in the duplex mode. As transmission media there are two twisted pairs, each for one transmission direction. The adapter also supports the MULTIDROP mode where the transmitter may be switched off as with RS-485. In this mode, one partner as the MASTER can communicate with up to 31 other partners operating as the SLAVE. 3.0 Installation E211 adapter installation is described in this part. There are two problems to be solved: the hardware installation and the SW driver installation. 4

3.1 USB interface connection The adapter operates as per specification USB 2.0 full-speed (12 Mbps). The USB adapter connector is of B female type. The adapter is connected to the terminal equipment via the USB jumper cable of AB type. 3.2 RS-485 Installing The TxRx+ and TxRx- clamps are used to connect the adapter to the bus. The adapter has to be set to the RS-485 mode via the 1-switch in Off position. The RS-485 line should be terminated with the 100-120 resistors on both ends. The reasons in more details are given in the 3.4 chapter. The external terminator (the resistor between TxRx+ and TxRx conductors) or the internal one the 3-switch in On position may be used. If the active termination is used (see the 3.4 chapter), it is necessary to place one resistor between TxRx+ and SP(+5V) clamps and one 820 resistor between TxRx- and SG (signal ground) via the internal active terminator using the 5 and 6 switches in On position. 3.3 RS-422 Installing In case of the point-to-point connection, the TxRx+ (TxRx-) clamp of the local adapter is necessary to be connected to the Rx+ (Rx-) clamp of the remote adapter and the Rx+ (Rx-) clamp of the local adapter to the TxRx+ (TxRx-) clamp of the remote adapter. The 1-switch has to be in On position, thus RS-422. The point-to-point duplex connection of the maximum rate that can be of up to 1 Mbps on the short line is carried out this way. For the MULTIDROP transmission system, it is necessary to distinguish if the adapter works in the MASTER or SLAVE mode. The TxRx+ (TxRx-) of the MASTER adapter is connected to the Rx+ (Rx-) clamps of all SLAVE adapters. The Rx+ (Rx-) clamps of the MASTER adapter are connected to the TxRx+ (TxRx-) clamps of all SLAVE adapters. The No.1switch of all adapters has to be in 422 position. The No.2 switch as the MASTER is On (Normal ), as the SLAVE is set to the Off position ( Multidrop ). 3.4 Importance of terminators The RS-422 recommendation (V.11) uses the symmetric signal transmitted via the twisted pair, there are various marks of the single wires: A-B, P-N, + - and the like. On the long lines there it is necessary to suppress the echo and the electromagnetic interference so the 100-120 resistors (so-called passive terminators) placed between A-B wires on the link ends are applied. The RS-485 recommendation uses the same symmetric signal as the RS-422 hence it requires the use of the passive terminators as the RS-422. On the RS-485 link, another state is defined when no communicating partner transmits all are of the high impedance state and just listening. 5

The partner differential receiver interprets the difference U A -U B. The receiver interprets the obtained signal as U A U B > 200 mv as log 1 or log 0. In the described still state, so-called IDLE, no communicating partner transmits so U A -U B < 200 mv. The problem is how to interpret the state (so-called the third) in the two-state logic. The active terminator (may be only one in each section) gives the signal U A U B >200mV into the idle state line and it is interpreted as IDLE in the two-state logic. The RS-422 MULTIDROP operation with the signal third state is similar to the RS- 485 hence the active terminators are used in this mode, too. 3.5 Ground potentials differences elimination The symmetric signal can deal with the cases when the signal ground potentials difference at the connection points of the partners differs by 5-7V. To eliminate influence of the ground potentials differences, the third conductor is used (see the Fig.). 100 resistors are needed in this case to eliminate currents resulting from the ground potentials differences. The signal ground clamp (labeled SG) may be used to this effect. 3.6 Adapter setting The mode switch is necessary to set to use the adapter in the situations mentioned above. First two switches (SW1, SW2) are used to the transmission mode setting the rest four switches place the terminators. 6

Mode SW1 SW2 RS-485 OFF -- MultiDrop ON OFF RS-422 ON ON Termination SW3 SW4 SW5 SW6 Without terminators OFF OFF OFF OFF Passive terminator between TxRx+ and TxRx- ON OFF OFF OFF Active and passive termin. on TxRx+and TxRx- ON OFF ON ON Passive terminator between Rx+ and Rx- OFF ON OFF OFF The switching automatics implemented into the USB 485/422 converter switches on the transmitter before the start bit transmission of a bit set-up time and switches off after the stop bit finish of a bit delay. 3.7 Installing driver The E211 adapter may be applied on the PC computers under the MS Windows 98/Me/2000/XP operating systems under the Linux operating system from 2.4 core version or on the Apple computers of OS-8 and OS-9 systems. The following chapter will only describe the drivers installation of MS Windows systems. The drivers are supplied together with the other files and the installation CD. They may be downloaded from the producer web-sides www.elo.cz. There are two ways how to use the adapter according to the type of installed drivers. The port may be accessed via the dynamic library or the virtual port. The access via the virtual port installed into the Device Manager is more comfortable and universal because any communication application which is able to select the number of the port to access may be applied. The access via the dynamic library when the user SW accesses to the adapter via the DLL library (chapter 3.4) requires programming knowledge but it offers much higher effectiveness and the real data rate. The proper installation of the drivers is indicated via the lit READY indicator on the cover connected to the adapter. While installing, the newer operating systems can display warnings the drivers are not certified. Do not worry, click Continue. 7

3.8 Installing virtual port under Windows XP 1) When the PC turned on and the adapter connected to the USB port via the cable is detected the operating system reports a new hardware has been found. 2) The system runs the Add New Hardware Wizard automatically. Failing this, the Control panel may be used to start the Wizard. Select the second option in the Wizard menu Install from a list or specific location. 3) In the next Wizard menu leave the system search for the proper driver on the supplied CD, in the directory \ e211 _drivers\serial_ port. 4) Leave the system to install the found driver. 5) Thus the USB device installing is completed. The virtual port installing follows automatically the same way as with 2-4, the device name is only different. 6) After successful installation the Wizard reports the installing has been completed. 3.9 Installing driver for direct access 1) When the PC turned on and the adapter connected to the USB port via the cable is detected the operating system reports a new hardware has been found. 2) The system runs the Add New Hardware Wizard automatically. Failing this, the Control panel may be used to start the Wizard. Select the second option in the Wizard menu Install from a list or specific location. 3) In the next Wizard menu leave the system search for the proper driver on the supplied CD, in the directory \ e211 _drivers \serial_ port. 4) Leave the system to install the found driver. 5) Now click Finish in the dialog box of the installing device completion. 3.10 Virtual port properties setting When connection is established the adapter virtual port appears as the next COM port in the Device Manager. Go to Control panel and select System / Hardware and run the Device Manager. The next COM called USB 485/422 Serial Port has appeared among the Ports. In Properties, its setting, e.g. transmission speed, character format and/or flow control can be changed. Caution!!! The control signals are not transmitted hence no hardware flow control can be used. The port number assignment (e.g. COM3, COM4, ) may be changed under the Specify option. 8

3.11 DLL Library use The annotated examples and English documentation of FT232BM chip used in E211 USB 485/422 adapter are on the CD. As the file streams are applied the programmer access does not differ from the common port access. In the most widespread VisualC language the methods accessible through the header file FTD2XX are needed and their names are derived from the names of the corresponding Win32 API methods adding FT_ prefix. Similarly, the DLL library can be used in Delphi, Builder and Visual Basic. 4.0 Specification 4.1 Parameters USB interface USB connector RS-422, RS-485 connector Communication mode Isolation between USB/RS4xx Transmission mode Maximum data rate 4.2 Other Supply Power take-off Dimension: Width Length Height Stocking temperature Working temperature Humidity USB 2.0 full-speed (12 Mbps) B type clamps full duplex, half-duplex isolation barrier of 1 kv for 1 sec asynchronous, duplex/half-duplex 1 Mbps from USB interface to 100mA (Low power) 55 mm 65 mm 20 mm - 10 o to +55 o C + 0 o to +50 o C 0 85% (non-condensing) 5.0 Testing When the USB cable is connected and the drivers are installed properly the LED READY has to light up. When the transmitter and receiver clamps are interconnected (TxRx+ to Rx+, TxRx- to Rx-) and 422 mode set to No.1 switcher the transmitted and received data has to be equal. The Hyper-terminal programme which is of the MS Windows part or E211_test supplied on the installation CD may be used for testing. The TxD and RxD LED diodes blink during the transmission. If there is the transmission of the low rate and the data blocks are very short the LED brightness is low because they only shine if the data signal is on the active level. It means the short data transmission (or even a sign transmission) of the high data rate are not perceptible to the 9

eye. To connect TxRx+ to Rx-, TxRx- to Rx+ clamp in the 422 mode, the correct operation in the idle state can be checked. Thus we create the transmitter signal negation for the receiver and the RxD diode has to light up. 6.0 Troubleshooting Symptom Adapter does not work after installation Connection in normal operation quit working. Action Check if the metallic link and the USB cable are connected properly Check the mode switches position. Check if the terminators are set properly. Check if READY is alight. Check if READY is alight. Check the cables connection. The 485-USB adapter is missing in the Device Manager Turn it off and on. If need be, repeat the installation. 7.0 Ordering information Supply code is ELO E211. The adapter is supplied with the installation CD. The USB cable of the required length can be ordered separately as it is not provided. 10

Note ELOE211ZKE001 11

12 ELOE211ZKE001