Panorama rudder indicator TRI-2 Analogue or CAN input Approved according to MED Three extra large scales Long-life LED illumination Built-in dimmer

Similar documents
RTC 300/RTC 600 Installation instructions scan

DATA SHEET Rudder/azimuth angle Transmitter CAN, RTC 300/RTC 600

XL/BW/BRW-2 Indicators USER'S MANUAL

Option X4 Additional Operator Panel AOP-2 Description of option Functional description

DATA SHEET Selectable AC transducer, TAS-331DG

Engine Control Unit, ECU 100 Engine control Engine monitoring and protection Easy-to-read graphical display Integrated emulation software solution

DATA SHEET Selectable AC transducer, TAS-321 DG

DATA SHEET IOM 200 analogue interface for AGC 200

Engine Control Unit, ECU 100 Engine control Engine monitoring and protection Easy-to-read graphical display Integrated emulation software solution

APPLICATION NOTES. HEADING INDICATOR SYSTEMS using XDi-N indicators. Document no.: A

E101 - Strain Gauge Transducer Display Module. Contents

SERIE 59. Rear clamp. Frontal clamp HIGH RESOLUTION HOLLOW SHAFT INCREMENTAL ENCODER FOR INDUSTRIAL APPLICATIONS

Compact Genset Controller, CGC 400 Generator control and protection Engine monitoring and protection Generator and mains breaker control RS485 Modbus

DEIF A/S. TAS-331DG Selectable AC transducer G (UK) Installation and start up instructions. Watt or var transducer

SRQ24A. Technical data. Safety notes. Rotary actuator for ball valves Torque 16Nm Nominal voltage AC/DC 24V Control: Open-close Running time 9s

DATA SHEET Compact Genset Controller, CGC 200

Automatic Genset Controller, AGC-4 What s in the delivery? Getting started The first steps Using the AGC

Supplementary instructions. Plug connector ISO for continuously measuring sensors. Document ID: 30375

Supplementary instructions. Plug connector ISO for level sensors. Document ID: 30380

RUDDER ANGLE INDICATION SYSTEMS

QUICK START GUIDE Generator Paralleling Controller, GPC-3 Generator Protection Unit, GPU-3/GPU-3 Hydro Paralleling and Protection Unit, PPU-3

DATA SHEET Advanced Graphical Interface, AGI 100 series

Installing Sentor. Hardware Installation

Delivery. Connection. C. AA+BB Helicoidal cable 2. Radial M12 8p CCW. 3. Radial M23 12p CCW

APU 200 Automatic DATA SHEET Gen-set Controller DATA SHEET

E102 - Advanced Strain Gauge Transducer Display Interface. Contents

Compact Genset Controller, CGC 400 What's in the delivery? The first steps Push-buttons and LEDs

XDi-Standard virtual indicator libraries B DEIF A/S. DEIF A/S, Frisenborgvej 33 Tel.: , Fax:

DATA SHEET Advanced Graphical Interface, AGI 300 series

MCx-xxxAx Installation. Contents. Mounting: Short Instruction MCx-xxxAx Connecting Power and Signal

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Supplementary instructions. Plug connector Harting HAN 7D. For point level sensors. Document ID: 34456

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Incremental Encoder with Hollow Shaft

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

QUICK START GUIDE Paralleling and Protection Unit PPU 300

1 open / 1 close, 240 V ac / 2 A. < 70 ma < 65 ma ac 20 Hz 13 Hz dc 72 Hz 25 Hz

Supplementary instructions. VEGADIS adapter. For connection of an external display and adjustment unit or a slave sensor. Document ID: 45250

Technical data. General specifications. Linearity error ± 0.1 Functional safety related parameters MTTF d 480 a at 40 C Mission Time (T M ) L 10

Supplementary instructions. Plug connector Harting HAN 8D. for continuously measuring sensors. Document ID: 30376

DATA SHEET. Advanced Energy Meter, AEM 380 & AEM 305

Keypad CT2000. Art. No.: , (black) Art. No.: , (white) Installation Manual

More Precision. wiresensor // Draw-wire displacement sensors

GREISINGER electronic GmbH. D Regenstauf, Hans-Sachs-Straße 26. T-Logg 120 W -... T-Logg 120 K -...

TECHNICAL DATASHEET Absolute Encoder AC 58 - CANlayer2

Manual. Simrad IS70/IS80 Rudder Indicators RI70 and RI80. English

ORYON RING LIGHTS. 14 in. Ring Light and 18 in. Ring Light. Quick Start Guide. What s Included

Conveyor Belt Alignment Switches from IDEM

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Insight Installation of FX30 Data Acquisition Unit (DAU) Login to Insight Setup Insight with your equipment in the cloud Related system information

Cables. U.S. Registered Trademark EN0B-0341GE51 R0402 Copyright 2002 Honeywell Inc. All rights reserved

Digital Keypad Introduction

More Precision. wiresensor // Draw-wire displacement sensors

Installing Keypad and Backplate

E3S-A. Built-in Amplifier Photoelectric Sensor (Medium Size) Ordering Information. Built-in Amplifier Photoelectric Sensors. Horizontal. 7 m.

Incremental encoders Solid shaft with clamping or synchro flange pulses per revolution

Technical data sheet. Technical data

Absolute Encoders Multiturn

Automatic Genset Controller, AGC-3 What's in the delivery Getting started The first steps Using the AGC

AGC 200 Advanced Gen-set Controller What s in the delivery? Getting started The first steps Using the AGC 200

LCx-xxxAx-8.08 Linear. Installation. Contents. Mounting: Short Instruction LCx-xxxAx Connecting Power and Signal

Automatic Genset Controller, AGC-4 What s in the delivery? Getting started The first steps Using the AGC

LIFEBUOY RELEASE SYSTEM - TECHNICAL PRODUCT SPECIFICATION AND INSTALLATION MANUAL

MIC-2 Multi-instrument DATA SHEET

Enhancing Business Performance

OPERATOR'S MANUAL Generator Paralleling Controller, GPC-3 - Generator Protection Unit, GPU-3/GPU-3 Hydro - Paralleling and Protection Unit, PPU-3

More Precision. wiresensor // Draw-wire displacement sensors

Installation instructions Inclination sensor EC2019 EC / / 2013

2M IR Mini Dome Quick Installation Guide

More Precision. wiresensor // Draw-wire displacement sensors

DATA SHEET. Advanced Power Meter, APM 380 & APM 305

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

QUICK START GUIDE Generator Protection Unit GPU 300

Power consumption In operation At rest For wire sizing

bidirectionally as well as the rotation sense of shafts. With absolute encoders instead, each incremental

AV24-MFT AV24-MFT2 AV24-MFT2-C105. Power consumption In operation For wire sizing N 1700 N Control Control signal Y Operating range

Option H8.x and H12.x External I/O modules Description of option Functional description

GSV-3USBx2 3,5mV/V 4,2V

Power consumption In operation At rest For wire sizing. Torque Inhibiting torque. 150 s / C Sound power level Motor

SPA-ZC 17. Bus connection module SPA-ZC 17. User s manual and Technical description. Tx SC Rx BB BM MB MM SPA / RS 485 POWER SLAVE 1 MASTER 0

RoHS. Shock / vibration resistant. Short circuit proof. Flexible. . XXXX e. . XXXX e

TECHNICAL MANUAL SAILOR SYSTEM 5000 GMDSS CONSOLE

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

DATA SHEET Advanced Graphical Interface, AGI 100 series

More Precision. Draw-wire displacement sensors

Luna Decorative Light Source Range

Products no longer available

Megatouch FORCE Monitor Chassis Board Replacement

Data Sheet for Angle Sensors

Vega Decorative Light Source Range

Power consumption In operation At rest For wire sizing. Torque Inhibiting torque. 150 s / C Sound power level Motor

DEIF A/S. MIC Multi-instrument G. Data sheet. Features. Accuracy. Measurements. Installation. Intelligent. Display. Communication DEIF A/S

Contents. Part no.: MLC500T Safety light curtain transmitter

Absolute encoders - bus interfaces Solid shaft with clamping or synchro flange Magnetic single- or multiturn encoders 14 bit ST / 18 bit MT

Getting started - USW 3.x Software download from internet Software installation Device setup Data backup

Technical data. Your advantages

Technical data. General specifications. Linearity error ± 0.1 Functional safety related parameters MTTF d 480 a at 40 C Mission Time (T M ) L 10

The PM1000 series is a universal 4 digit LED plug-on display for transmitters with 4-20mA 2 wire output and fitted with DIN43650 connector.

Accsense Wireless System. Temperature Monitor

ATM 60/ATM 90: Multiturn Absolute Encoders extremely robust and exceptionally reliable.

Transcription:

USER'S MANUAL Panorama rudder indicator TRI-2 Analogue or CAN input Approved according to MED Three extra large scales Long-life LED illumination Built-in dimmer DEIF A/S Frisenborgvej 33 DK-7800 Skive Tel.: +45 9614 9614 Fax: +45 9614 9615 info@deif.com www.deif.com Document no.: 4189350053C SW version: N/A

1. General information 1.1. Disclaimer...3 1.1.1. Disclaimer...3 1.2. Product presentation... 3 1.2.1. TRI-2 and TRI-2 CAN... 3 2. Before using the product 2.1. Initial steps... 4 2.1.1. Remove transport lock...4 2.1.2. Mounting...5 3. Setting up TRI-2 3.1. Connection... 6 3.2. Connection of analogue version...6 3.2.1. TRI-2...6 3.2.2. Current input...6 3.2.3. Voltage input...7 3.2.4. Voltage input 3-wire... 7 3.3. Adjustment and setup...7 3.3.1. Voltage versions... 8 4. Setting up TRI-2 CAN 4.1. Connection and setup... 9 4.1.1. TRI-2 CAN... 9 5. Connections of CAN version 5.1. Connections... 10 5.2. Single CAN setup... 11 5.2.1. Setup example...12 5.2.2. Make max. adjustment...12 5.3. Dual CAN setup...13 5.4. Remote dimmer...15 5.4.1. TRI-2 and TRI-2 CAN remote dimmer...15 6. Technical information 6.1. Specifications... 16 6.1.1. TRI-2 and TRI-2 CAN... 16 DEIF A/S Page 2 of 16

General information 1. General information 1.1 Disclaimer 1.1.1 Disclaimer DEIF A/S reserves the right to change any of the contents of this document without prior notice. The English version of this document always contains the most recent and up-to-date information about the product. DEIF does not take responsibility for the accuracy of translations, and translations might not be updated at the same time as the English document. If there is any discrepancy, the English version prevails. 1.2 Product presentation 1.2.1 TRI-2 and TRI-2 CAN The rudder angle indicator type TRI-2 and TRI-2 CAN is used for the indication of the rudder position on the bridge. The light intensity can be changed by means of a built-in dimmer accessible on the rear plate of the indicator. Optional remote dimming from a control panel can be used. DEIF A/S Page 3 of 16

Before using the product 2. Before using the product 2.1 Initial steps 2.1.1 Remove transport lock Transport lock mounted The transport lock (bright red plastic) is mounted to prevent the pointers from being damaged under heavy vibration and shock (transportation). The transport lock must be removed before connecting the indicator! Removal of rear plate Remove the rear plate (4 screws). Removal of transport lock Gently draw the transport lock out with a hand. When inserting the transport lock again, gently insert it between the scale guide (white plastic part inside) and the housing (black part). Transport lock view Please keep the transport lock in case you need to ship the indicator after system test, or in case you need to return the indicator to DEIF for service! DEIF A/S Page 4 of 16

Before using the product Mounting the rear plate Tighten the screws only by hand and with a maximum at 0.5 nm torque to avoid overtighten the screws. 2.1.2 Mounting TRI-2 and TRI-2 CAN have been designed for mounting on the ceiling of the bridge. The cables are connected through the rear panel or through the ceiling. Weight: Approx. 1.5 kg. Make sure that the instrument is mounted on an even surface to prevent the instrument housing from deforming. DEIF A/S Page 5 of 16

Setting up TRI-2 3. Setting up TRI-2 3.1 Connection Depending on the ordered version of TRI-2 analogue or CAN version, different connections and settings apply. The analogue versions of the TRI-2 allow only small adjustments whereas it is possible to make more adjustments on the CAN version. 3.2 Connection of analogue version 3.2.1 TRI-2 After removing the rear panel, the connection terminals are visible. Cable dimensions between 0.2 and 2.5 mm 2 can be used for the terminals. 3.2.2 Current input Terminal 1 Terminal 2 Pointer response (TRI-2 mounted in the ceiling) - current out + current in 0/4 ma Max. left 10/12 ma Zero 20 ma Max. right Not possible to make adjustments on TRI-2 with current input. DEIF A/S Page 6 of 16

Setting up TRI-2 3.2.3 Voltage input Terminal 1 Terminal 2 Pointer response (TRI-2 mounted in the ceiling) +/- V in 0 V in -10 V Max. left 0 V Zero +10 V Max. right 0 V +V in 0 V Max. left 5 V Zero 10 V Max. right The voltage fro illumination may be either 24 V AC or 24 V DC. 3.2.4 Voltage input 3-wire Potentiometer R1 can be used to adjust the deflection of the instrument within +/-10% of full scale to fit the scaling of the indicator to the existing installation. 3.3 Adjustment and setup When the instrument has been properly connected to the analogue rudder transmitter, it can be adjusted to ensure that alignment is in correct position with the rudders. Mechanical zero adjustment is placed in the bottom of the instrument. It is adjusted to zero with the rudder in position zero. The rudder is now turned to maximum position. The instrument indication should be the same as the rudder angle. NOTE: No zero adjustment on 0 to 20 ma and 4 to 20 ma versions. Potentiometer R1 can be adjusted if the instrument indication is not the same as the rudder angle. Potentiometer R1 is placed on the left side of the three blue potentiometers. Remember to remount the rear plate with all 4 screws to ensure the IP54 protection of the instrument. DEIF A/S Page 7 of 16

Setting up TRI-2 3.3.1 Voltage versions When the mechanical zero position has been adjusted, it is possible to make adjustments to the maximum position. The rudder must be turned to the maximum position. Adjusting the potentiometer R3 will move the pointer of the TRI-2. When adjusting the 3-wire version, the same procedure is used. But to adjust the maximum, the potentiometer R15 should be used to adjust the maximum deflection. The maximum range of the maximum deflection is 10 % of the input value. DEIF A/S Page 8 of 16

Setting up TRI-2 CAN 4. Setting up TRI-2 CAN 4.1 Connection and setup 4.1.1 TRI-2 CAN On the CAN version, the connection terminals are also located under the rear plate on the analogue versions. To make adjustment on scan and dual CAN versions, an encoder is used. The encoder (integrated pushbutton/rotating encoder) is located between the two sets of connectors. The encoder is used for the entire set-up together with the two LEDs marked 1 and 2 located on each side of it. Notice that the terminals have been numbered from right to left. A CAN termination switch is placed on the left side of terminal 11. This switch terminates the CAN1 line with 120 Ohm when set to ON (switch is pushed to the right, towards connector X3). Normal position will be OFF = no termination (switch is pushed to the left). Note that only CAN1 has this termination possibility! CAN1 termination switch 11 10 9 8 7 OFF ON Terminals X3 DEIF A/S Page 9 of 16

Connections of CAN version 5. Connections of CAN version 5.1 Connections Pin no. Function CANopen Note 1 Supply voltage +12 V to 24 V DC Consumption 12 V 300 ma/24 V 150 ma 2 0 V DC " 3 CAN connection CAN 2 H input CAN 2 line 4 CAN 2 L input " 5 CAN 2 GND " 6 NC " 7 CAN 1 H input CAN 1 line 8 CAN 1 L input " 9 CAN 1 GND " 10 Illumination Dimmer wiper Dimmer control via 1 kohm 2 W potentiometer 11 Dimmer ref. " The label is located under the lid with the dimmer potentiometer. DEIF A/S Page 10 of 16

Connections of CAN version 5.2 Single CAN setup The table describes the different settings which can be made for the scan version. Depending on the selected operation, it is possible to make changes or see the factory settings of the TRI-2. Time-out: if a mode is entered and no changes made, a time-out of 5 minutes will ensure that the TRI-2 will return to normal operation. When a setting has been changed, save command must be used to save the change. This is done by pressing the mode button for more than 5 seconds until the TRI-2 returns back to normal operation. If multiple changes are to be made, the save command must be used after each change. DEIF A/S Page 11 of 16

Connections of CAN version 5.2.1 Setup example In normal operation, a single flash on LED1 indicates that CAN protocol "Single CAN" is in use. If in doubt whether the TRI-2 is ordered to the right protocol, this can be seen in menu 304 (303). Be aware that the protocol can only be set in the TRI-2 order process. Going from normal operation mode (100) to installation mode (200), press the encoder for 5 seconds. Afterwards, in mode 200, presses of 1 seconds will result in jumps from mode 200 to 201-202 - 203-200. To save the settings, press the encoder for 5 seconds. Notice that settings must be saved before entering the next mode. For example, a zero adjustment performed in mode 200 must be saved before going to mode 201 for maximum adjustment. If the advanced setup is needed, if for example the pointer direction has to be changed from CW to CCW, then go to mode 203 and press the encoder for 10 seconds to activate mode 301. Afterwards, every press of 1 second will result in jumps from mode 301 to 302-303 - 304-305 - 301. Notice that settings must be saved (press 5 seconds) before entering the next mode. To leave advanced setup, press the encoder for 5 seconds. During setup, the input value (if available) is indicated on the instrument. Time-out: after 5 minutes without any change, the unit will return to normal operation without saving. 5.2.2 Make max. adjustment Adjustment of the TRI-2 can be set for max. and zero. The TRI-2 will then internally make a linear adjustment from minimum to zero and to maximum. Max. is defined on the left side of the TRI-2, opposite the cable input; see picture below: TRI-2 clockwise rotation When the rotation of the TRI-2 is set to clockwise, the rudder must be positioned at port side when making the max. adjustment. If the rotation counter is clockwise, the rudder must be positioned at starboard when adjusting max. The procedure to adjust maximum is described below: 1. Set rudder at port side maximum 2. Enter installation setup 3. Press the tumble wheel once, and both LEDs will be yellow 4. Turn the tumble wheel until the pointer moves to the right position on the scale 5. Save the value by pressing the tumble wheel for more than 5 seconds. The TRI-2 returns to normal mode. DEIF A/S Page 12 of 16

Connections of CAN version 5.3 Dual CAN setup DEIF A/S Page 13 of 16

Connections of CAN version In normal operation, a double flash on LED 1 and 2 indicates that CAN protocol "Dual CANopen" is in use. If the CAN bus is not detected, wrong writing or wrong protocol may have been ordered. Enter "Advanced mode 304" to see which protocol has been ordered. Note that the shown CAN protocol can't be changed from the menu. If a TRI-2 needs another protocol, a new indicator must be ordered. Time-out: after 5 minutes without any change, the unit will return to normal operation without saving. DEIF A/S Page 14 of 16

Connections of CAN version 5.4 Remote dimmer 5.4.1 TRI-2 and TRI-2 CAN remote dimmer If remote dimmer is preferred, the built-in dimmer potentiometer can be removed from the indicator (after dismantling the rear plate) and mounted e.g. in a control panel. A plug to seal the hole in the rear plate is included on delivery. The following example is for the TRI-2 with analogue input, but it is similar for the TRI-2 CAN version (however, only 2 wires to the potentiometer is needed). Connecting the wiper (centre pin) on the dimmer potentiometer to a wrong terminal in the TRI-2 may destroy the illumination circuit!therefore - be very careful to connect the wire coming from the wiper (centre pin on the potentiometer) to the terminal marked 1 (wiper) in TRI-2 (see drawing below). (This only applies for TRI-2, not TRI-2 CAN). 2 4 1 3 5 11 12 13 11: Red 12: Orange 13: White Red Orange White Potentiometer front 24 11.9 13 2.5-0.2 8 6 10.2 max 19.8 ø 24.2 M10 x 75 Button 2.6 +0.1 12.2 +0.3 max 20 If dimming via CANbus is used on TRI-2 CAN, the manual dimmer will be off. DEIF A/S Page 15 of 16

Technical information 6. Technical information 6.1 Specifications 6.1.1 TRI-2 and TRI-2 CAN Key specifications Compass safety distance Auxiliary voltage: TRI-2 TRI-2 CAN Consumption: TRI-2 TRI-2 CAN 1 metre 24 V AC/DC ±25 % (illumination only) 12 to 24 V DC -25/+30 % (note: DC only!) Max. 3 W Max. 4 W Cable dimensions 0.2 to 2.5 mm 2 Cable entries Cable outer diameter Error indications TRI-2 CAN Via two PG 13.5 cable glands 6-12 mm Pointer totally CCW indicates no aux. voltage connected to the instrument Pointer totally CW indicates no CAN data received Pointer totally CCW or CW can also indicate internal processor error or CAN data out of range CAN bus problems can be diagnosed using the colour sequence of the two LEDs behind the rear plate (see setup tables). NOTE: TRI-2 with analogue input, no special error indications are available DEIF A/S Page 16 of 16