Operating Instruction for Turbine-wheel Flow Meter. Model: DRS

Similar documents
Operating Instructions for Low Volume Rotating Vane Flow Meter. Model: DPL-1P... DPL-1V... DPL-1E...

Operating Instructions for Low Volume Rotating Vane Flow Meter. Model: DPL-1P... DPL-1V... DPL-1E...

Operating Instruction for Rotating Vane Flow Meter. Model: DRG-...

Operating Instructions for Low Volume Rotating Vane Flow Meter. Model: DTK

Operating Instructions for Rotating Vane Flow Meter. Model: DRH-...

Operating Instruction for rotating vane flow meter Model: DPM-...

Operating Instruction for Turbine-wheel Flow Meter. Model: DRB-...

Turbine Wheel Flow Meter/ Monitor for Liquids

Operating Instructions for Turbine Wheel Flow Meter. Model: TUR

Operating Instructions for Level Switch for Liquids. Model: RFS

Operating Instructions for Digital Thermometers. Model: DTM

Operating Instructions for Differential Pressure Sensor. Model: PMP

DRS. OEM Turbine Flow Sensor. for Liquids

Operating Instructions for Vibrating Level Switches. Model: NVI

Operating Instructions for Turbine Wheel Flow Meter Model: TUR

Operating Instructions. Power Supply & Isolation Relay for Switches Model: RL manual_rl-5900_0215

Operating Instructions for Evaluation Electronics. Model: ZED-K and DF- KLxxx

Operating Instructions. Power Supply & Latching Relay For Switches Model: RL manual_rl-6000_1016

Level sensor Stainless steel version Model RLT-1000, for industrial applications

Operating Instruction Supplement for Compact Electronics. Model:..C30R;..C30M..C34P;..C34N

DPE. Turbine Wheel Flowmeter. for liquids. Measuring ranges: l/min water. Measuring accuracy: ± 2.5 % of full scale

Compact Vortex Flow Meter for Low Viscosity Liquids

DRH. Paddle Wheel Flow Sensor

DCT 531. Industrial Pressure Transmitter with RS485 Modbus RTU. Stainless Steel Sensor

Operating Instructions. Isolation Relay for Switches Model: RL manual_rl-6100_1116

MSR Level Control Relay Module Operating Instructions for Level Control Relay Module Model: MSR

DMP 333 DMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial

KOBOLD Compact Electronics

Operating Instructions. Intrinsically Safe Isolation Relay for Switches Model: REL manual_rel-6_0505

Online data sheet TBS-1BSGT3506FM TBS TEMPERATURE SENSORS

Easy Flow Indicator Magnetisch-Induktiver Durchflussmesser. Type 8024 For Insertion Fittings. Analog Flow Rate Indicator, 1/2"-16"; P=87 PSI

Distance and Position Sensors

Flow Sensor SONOFLOW CO.55

1 open / 1 close, 240 V ac / 2 A. < 70 ma < 65 ma ac 20 Hz 13 Hz dc 72 Hz 25 Hz

DRH. Paddle Wheel Flow Sensor

Electronic Level Switch ENS 3000

Linear Position Transducer HLT 1000-R2

LMP 308. Separable Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO / 0.

standard, short, preferential, top

Instruction Manual DR58 Brass Paddle Wheel Flow Meter

QVE3000.0xx QVE3100.0xx. Flow sensor. for liquids in DN10 25 pipes

Float switch For industrial applications Model RLS-1000

Operating Instructions. For. Level Control Module. Model SSR 1000

Pressure transmitter for highest pressure applications Up to 217,500 psi (15,000 bar) Model HP-2

DS 201P. Electronic Pressure Switch. Pressure Port With Flush Welded Stainless Steel Diaphragm. accuracy according to IEC 60770: 0.

SM9000. Magnetic-inductive flow meter. Made in Germany

DVZ - Vortex Flowmeter and Switch

PKP Prozessmesstechnik GmbH. Borsigstrasse 24. D Wiesbaden-Nordenstadt. Tel: / Fax: / Operating manual PSA06

JUMO PINOS L01. Calorimetric flow sensor. Brief description. Special features. Customer benefits. Data Sheet

MPS-32. Pressure Sensors MPS-32 2-Color Panel Mount. Features. Green Display. MPS-32 Programming Options

KOBOLD TDA Series Digital Temperature Transmitter

Product Catalog. Represented by Norstat Inc. in North America

Electronic pressure switch with display Model PSD-4

Temperature Switches

Linear Position Transducer HLT 1000-R2

Bourdon tube pressure gauge with electrical output signal Stainless steel, safety version, NS 63 Model PGT23.063

Viscosity-Compensated Flow Meters and Switches

Technical Data Photoelectric Sensors

Installation, Operation & Maintenance Instructions / Technical Document

Inductive proximity switches with long operating distance, series 500

Pressure sensor For highest pressure applications to 15,000 bar Model HP-2

LS 6600 Technical Datasheet

Operating Instruction

Flow sensors SFAB Key features

Flow sensors SFAM Key features

Assembly Instructions scancontrol 2700/2750 (500)

Immersion Temperature Sensors

Operating Instructions for Counter Electronic Model: ZED-Z. or DF- ZLxxx or Model- ExxR

Switch on / off. For switching off please press button for approx. 5 sec.

Operating Instructions for Evaluation Electronics. Model: ZED-K and DF- KLxxx

Inductive sensor NI3-EG08K-Y1-H1341

Miniaturised pressure sensor Model M-10, standard version Model M-11, version with flush diaphragm

Electro-Mechanical Counters

JUMO MIDAS C08. OEM Pressure Transmitter Basic. Applications. Brief description. Special features. Customer benefits

Option 2. Nil. Note 1) Option 1. Note With waterproof seal and mounting screw. With waterproof seal and mounting screw. 48 conversion adapter

Operating manual LRD 325. Conductivity measuring cell to be installed in pipelines

Technical Data Sheet SONOFLOW CO.55/xxxSD(H) V2.0

Pile Driver Weld Immune Sensors

GPLS-25 DATASHEET Março 2012

Device Configurator ECI-1

THERMASGARD TM 65. Immersion screw-in duct temperature measuring transducer, calibratable, with multi-range switching and active output TECHNICAL DATA

INSTALLATION GUIDE Magnetostrictive Sensor Series MAZ

NEW product. Large digital pressure sensor 31series. Easily viewable LCD dual displays. High level visibility with 3-color display.

Flow Meter FC01-Ex FC01-Ex

Operation Manual SRZ Helical Flow Meters

Electronic pressure switch with display For sanitary applications Model PSA-31

SonoMeter 30 Ultrasonic energy meter for heating and cooling applications

Display Solid-state Temperature Switch

JUMO MIDAS C08. OEM Pressure Transmitter Basic. Applications. Brief description. Special features. Customer benefits

DIGITAL DISPLAY. for Industry Applications. Series WAY-SSI. Key-Features:

Absolute Encoders Multiturn

IK4A (with ONDA technology)

Datasheet DE DB_EN_DE44_LCD Rev. ST4-C 07/17. Digital 2-channel differential pressure switch/transmitter with colour-change LCD * *

RoHS. High shaft load capacity. Shock / vibration resistant

BNI IOL A027 BNI IOL A027

Pressure sensors SPAN

XUK8TAKSMM12 photo-electric sensor - XUK - diffuse - Sn 5m 1Q auto PNP/NPN

(see also technical drawings) Width with inlay

Level and temperature switch Nivotemp NT-M, NT-MD

English. Operating manual. Universal transmitter UT125. Save for later reference. Companies / brands of GHM

Transcription:

Operating Instruction for Turbine-wheel Flow Meter Model: DRS

. Contents. Contents... 2 2. Note... 3 3. Instrument Inspection... 3 4. Regulation Use... 3 5. Operating Principle... 4 6. Mechanical Connection... 4 7. Electrical Connection... 5 8. Commissioning... 9 9. Maintenance... 9 0. Technical information... 0. Order Codes... 2 2. Dimensions... 3 3. EU Declaration of Conformance... 5 Manufactured and sold by: Kobold Messring GmbH Nordring 22-24 D-6579 Hofheim Tel.: +49(0)692-2990 Fax: +49(0)692-23398 E-Mail: info.de@kobold.com Internet: www.kobold.com Page 2 DRS K06/048

2. Note Please read and take note of these operating instructions before unpacking and putting the unit in operation and follow the instructions precisely as described herein. The devices are only to be used, maintained and serviced by persons familiar with these operating instructions and with the prevailing regulation applying to procedural safety and the prevention of accidents. When used in machines, the measuring unit should be used only then when the machines fulfil the EC-machine guide lines. PED 204/68/EU In acc. with Article 4 Paragraph (3), "Sound Engineering Practice", of the PED 204/68/EU no CE mark. Table 8, Pipe, Group dangerous fluids 3. Instrument Inspection These devices are checked before shipping and sent out in perfect condition. Should damage to a device be visible, we recommend a thorough inspection of the delivery packaging. In case of damage, please inform your parcel service/forwarding agent immediately, since they are responsible for damages during transit. Scope of delivery: Turbine-Wheel Flow Meter: Model DRS Operating Instructions 4. Regulation Use The DRS is to be installed only in the specified applications. Any use of the DRS sensor which exceeds the manufacturer s specifications may invalidate the warranty and any resulting damage is not the responsibility of the manufacturer. The user assumes all risk for such usage. The application specifications include the installation, start-up and service requirements specified by the manufacturer. DRS K06/048 Page 3

5. Operating Principle The DRS flow meter operates on the turbine wheel principle. The liquid first flows through a laminar flow element that eliminates turbulence and routes the flow stream into the turbine wheel. The turbine wheel then starts to rotate. This rotary motion is sensed non-contacting by magnets embedded in the turbine wheel and converted to a frequency signal. The frequency is proportional to the flow velocity. Various outputs, such as a frequency divider, analogue output or compact electronics with LED display with limit contacts are available as options. An integrated temperature sensor for simultaneous measuring of flow rate and temperature is also available as an additional option. The rotating vane is sapphire-supported: this ensures a high degree of linearity and long service life. 6. Mechanical Connection 6.. Operational conditions check-up: Flow volume max. operational pressure max. operational temperature Attention! Exceeding prescribed ranges may cause damage to ballbearings and considerable measurement errors may result. 6.2. Mounting Direction of flow must match the direction of arrow (position independent). Pressure- and tensile loading is to be avoided on the connection threads. Inlet and outlet piping should be secured at least 50 mm away mechanically from the connections. Check the sealing of the connections The use of flat sealings is to be preferred. The sealing surfaces are shown in section - Dimensions Page 4 DRS K06/048

7. Electrical Connection 7.. General Attention! Ensure that the power ratings of your supply system are in agreement with the power ratings of the flow meter. Please ensure that the electric supply lines are not active. Wire the connection cable/plug with the supply line according to the following connection diagram. We recommend a cross-sectional area of 0.25 mm² for the supply line. Attention! A false level on plug connections may cause destruction of unit s electronics. 7.2. Evaluation electronics Frequency output without Pt00 Plug connection(..f3000;..f3200;..f3400;..f3900) n.c. 2 +Vs 3 4 Signal Out Plug connection (..F5000;..F5200;..F5400;..F5900;..K0000) brown: blue: Black: + V S Signal...S000...S00P white: + Vs brown: + Vs green: Signal black: Signal brown: green-yellow: /PT00- yellow: PT00-2 DRS K06/048 Page 5

7.3. Evaluation electronics: Frequency output and analogue output with Pt00 (DRS-..P) Plug connection (..F300P;..F320P,..F340P,..F390P,..L303P;..L343P) Cable connection (..F500P;..F520P,..F540P, F590P) brown: +Vs blue: / Pt00 black: Signal white: PT00 2-wire grey: PT00 2-wire 7.4. Evaluation electronics: analogue output (..L..) 3-conductor (..L303,..L343) +Vs n.c. 2 +Vs 3 4 Signal Out Page 6 DRS K06/048

2-conductor (..L342) +Vs n.c. 2 S+ n.c. 3 4 S- 2-conductor, DIN-plug (DRS-...L442) +Vs S- PE 2 3 n.c. S+ 7.5. Compact electronics: (..C30R,..C30M,..C34P,..C34N) Please see Operating Instruction Manual for compact electronics with frequency output DRS K06/048 Page 7

7.6. Evaluation electronics: Pointer display (..Z300,..Z340) +Vs n.c. 2 +Vs 3 4 Signal Out Caution! In case current output is not needed, PIN 4 (Signal OUT) is to be permanently connected wit Ground () (short circuit jumper). page 8 DRS K05/6

8. Commissioning 8.. Frequency output The measuring units are pre-adjusted and ready for operation after electrical connection. 8.2. Analogue output The measuring units are pre-adjusted and ready for operation after electrical connection. 8.3. Pointer display (..Z300,..Z340) The measuring units are pre-adjusted and ready for operation after electrical connection. 8.4. Compact electronics Please see Operating Instruction Manual for compact electronics with frequency output 9. Maintenance As long as the medium to be measured is not polluted, the measuring unit is maintenance-free. In order to avoid problems, we recommend installation of a filter, such as magnet filter, Model MFR. Should cleaning be deemed necessary, the sensor must be uninstalled and rinsed thoroughly in clean water. Work on electronics may only be carried out by the supplier, so that the product guaranty remains valid. DRS K06/048 Page 9

0. Technical information 0.. Sensor data Measuring range: 2-40 L/min water Sensor pulse output: 384 Hz at 40 L/min Metal Sensor (DRS-...50; DRS-...250) 352 Hz at 40 L/min plastic sensor (DRS-...350) Max. operating pressure: 200 bar (DRS-...50; DRS-...250) 6 bar (DRS-...350) Temperature: -20 to +80 C (medium, standard), -20...+50 C (medium, -S00x), -20 to +00 C (storage) Measuring accuracy: ±.5% of f.s. ±5 % of f.s. (DRS-0) Linearity: ±0.5 % of f.s. Repeatability: ±0. % of f.s. Electrical connection: plug connector M2x.5 m cable (DRS-0 only) 2 m cable (DRS-...F5 only) Protection: IP 65 (plug connector), IP 66 (cable) Weight (sensor and electronics) Sensor: approx. 80 g (DRS-...350) approx. 550 g (DRS-...50; DRS-...250) Electronics: approx. 60 g (DRS-...K..; DRS-...F..; DRS-...L3...) approx. 00 g (DRS-...L442) approx. 450 g (DRS-...Z...) approx. 650 g (DRS-...C...) 0.2. Evaluation electronics DRS-0...K000 / DRS-0...S00x Supply: Output pulse: DRS-...F300, DRS-...F500 Supply: Power consumption: Pulse output: Option: Response time (Pt00): 5...28 V DC rectangular pulse signal, open collector, NPN, max. 0 ma 2 28 V DC 0 ma PNP, open collector, max. 20 ma Pt 00, 2-wire t 90 = 00 s page 0 DRS K05/6

DRS-...F390 Supply: 24 V DC ± 20 % Power consumption: 5 ma Pulse output: PNP, open collector, max. 20 ma Frequency divider:.../28, factory setting Option: Pt 00, 2-wire Response time (Pt00): t 90 = 00 s DRS-...L... Supply: 24 V DC ± 20% Output: 0(4)-20 ma, 3-wire or 2-wire Max. load: 500 Option: Pt 00 (2-wire) Response time (Pt00): t 90 = 00 s DRS-...C30... Compact electronics Display: Switching outputs: Contact operation: Setting: Supply: Power consumption Electrical connection: DRS-...C34... Compact electronics Display: Analogue output: Switching outputs: Contact operation: Setting: Supply: Power consumption: Electrical connection: 3-digit LED 2 semiconductor PNP or NPN, factory set N/C / N/O contact frequency programmable with 2 buttons 24 V DC ±20%, 3-wire approx. 00 ma plug connector M2x 3-digit LED (0)4...20 ma adjustable, max. 500 Ω semiconductor PNP or NPN, factory set N/C / N/O contact frequency programmable with 2 buttons 24 V DC ±20%, 3-wire approx. 00 ma ma plug connector M2x DRS-...Z... Pointer indicator with analogue output Housing: aluminum Display: moving-coil instrument, 240 display Power supply: 24 V DC ±20% Output: 0-20 ma or 4-20 ma, 3-wire Max. load: 250 Electrical connection: plug connector M2x DRS K06/048 Page

. Order Codes Order Details (example: DRS-9350 I4 L303 0) Material sensor housing Model Connection Evaluating electronics Option Frequency output F300 = Plug connector M2x, PNP F320 = Plug connector M2x, PNP, divider :2 F340 = Plug connector M2x, PNP, divider :4 F390 = Plug connector M2x, PNP, divider... /28 F500 = 2 m PVC cable, PNP Brass Stainless steel Plastic (Noryl) DRS-950 DRS-9250 DRS-9350 4 = G /2 female thread G4 = G /2 female/ male thread G5 = G 3/4 male thread N5 = 3/4 NPT male thread Analogue output L303 = Plug connector M2x, 0-20 ma, 3-wire L342 = Plug connector M2x, 4-20 ma, 2-wire L343 = Plug connector M2x, 4-20 ma, 3-wire L442 = Plug connector DIN 43 650, 4-20 ma, 2-wire Compact electronics ) C30M = LED display, 2 x NPN switching output, Plug connector M2x C30R = LED display, 2 x NPN switching output, Plug connector M2x C34N = LED display, 4-20 ma, NPN switching output, Plug connector M2x C34P = LED display, 4-20 ma, PNP switching output, Plug connector M2x 0 = without P = Pt 00 2) Y = Special model Pointer indication, 240 ) Z300 = Pointer indication, 0-20 ma, Plug con. M2x Z340 = Pointer indication, 4-20 ma, Plug con. M2x ) Please specify flow direction in writing. 2) Only for option F3/F5 and L3x3 in brass and st.st. version Plug-on display For model DRS-...L442 (with 4-20 ma output and DIN plug connector) Description 4-digit LED, connector DIN 43650, 2-wire, supply through analogue output as above however with additional open collector output Order number AUF-000 AUF-00 Order details OEM version example: DRS-0350 I4 K0000) Material sensor housing Model Connection Evaluating electronics Brass DRS-050 I4 = G /2 female thread Stainless steel Plastic (Noryl) DRS-0250 DRS-0350 G4 = G /2 female/male thread G5 = G 3/4 male thread N5 = 3/4 NPT male thread Frequency output K0000 =.5 m PVC cable, NPN, OEM without CE S000 =.5 m Silicone cable, NPN, OEM without CE S00P =.5 m Silicone cable, NPN, PT00, OEM without CE (Version S00x not available for DRS-0350) page 2 DRS K05/6

2. Dimensions Connection threads: female/female; male/male and female/male with the same outer dimensions. Kabelversion 35 M2x 50 63,4 D 6 36 DRS-...F/...L 80 SW 32 D DRS K06/048 Page 3

7 3 2 44,5 3,5 50 Cable 2 m with plug M 2x 5 8 5 2 0 SW 36 D A OBOLD A DRS-...C D SW 32 80 D DRS-...Z D D = Sealing areas page 4 DRS K05/6

3. EU Declaration of Conformance We, KOBOLD-Messring GmbH, Hofheim-Ts, Germany, declare under our sole responsibility that the product: Turbine-wheel Flow Meter Model: DRS to which this declaration relates is in conformity with the standards noted below: EN 6000-6-4:20 Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments EN 6000-6-2:20 Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity for industrial environments EN 600-:20 Safety requirements for electrical equipment for measurement, control and laboratory use - Part : General requirements EN 60529:204 Degrees of protection provided by enclosures (IP Code) Also the following EC guidelines are fulfilled: 204/30/EU EMC Directive 20/65/EU RoHS (category 9) Hofheim, 07. Apr. 206 H. Peters M. Wenzel General Manager Proxy Holder DRS K06/048 Page 5