Airedale International Air Conditioning Limited. Leeds Road, Rawdon Leeds, LS19 6JY, England

Similar documents
Ecotel Free Cool 5-15kW

Total Modular Data Centre Solutions

Precision Cooling for Business-Critical Continuity. Liebert HPC-S. Designed for the Efficient Cooling of Small Data Centers

Training courses 2018

CHILLERS & HEAT PUMPS DYNACIAT HIGH ENERGY PERFORMANCE WITHIN OPTIMISED FOOTPRINT

AIR COOLED CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS

PT CLIMANUSA TATA MEKADATA Citypark Business District Blok F No 05 Jl. Malibu Raya, Cengkareng Jakarta Barat Indonesia. Phone

Product Brochure DENCO Close Control Units Row-DENCO. High Density Cooling for Data Centres

pco sistema programmable controllers Technology & Evolution

Your Solution For Energy and Cost Savings. McQuay Packaged Chiller Plant

CTC Low Temperature Process Chillers

Aquaflair. Uniflair TRAC, TRAF and TRAH. Air-cooled chillers, free-cooling chillers and heat pumps with scroll compressors.

AIR COOLED HEAT PUMPS WITH SCREW COMPRESSORS AND AXIAL FANS

GP SERIES Packaged Chillers

APPLIED SYSTEM AWS FAMILY FOR LARGE APPLICATIONS PRODUCT LEAFLET. Capacity from 600 to 2,010kWr. Engineered for flexibility and performance

CHAPTER 3 WATERCOOLED & CONDENSERLESS LIQUID CHILLERS AND HEAT PUMPS FOR COMMERCIAL & INDUSTRIAL APPLICATION. REMOTE CONDENSERS

CHILLED WATER. HIGH PRECISION AIR CONDITIONERS, FROM 7 TO 211 kw

Chiller. CG 010 to 130. Remote Air Cooled Condensers Engineering Data Manual. 9.4 to 131 kw

Media Pack. ENERGY EFFICIENCY BRITISH MANUFACTURER TRAINING

4-step Chiller and Heat Pump Controller

IT COOLING AIR CONDITIONERS FOR HIGH DENSITY RACKS AND BLADE SERVERS. RACK COOLING SOLUTIONS FOR HIGH DENSITY RACK MANAGEMENT, FROM 4 TO 75 kw

A Data Center Heat Removal System That Saves... 80% Discover Inertech s Award-winning Data Center Heat Removal System

MPC Air-Cooled Chillers MPC-FC Free-Cooling Chillers

CL20 Rear Cooler. New Generation Computer Room Cooling

glide glider kw R134a air cooled liquid chillers AND free cooling chillers FREE COOLING SHELL A C CLASS E C Energy Class RCGROUP SpA

CLIMATE. CUSTOMIZED. CyberHandler2 from 30KW to 520 KW. The indirect evaporative free-cooling Air Handling Unit

Aquaflair. BREC & BREF kW 380V/3ph/60Hz - 460V/3ph/60Hz. Air-cooled chillers and free-cooling chillers with double screw compressors

The new generation of dedicated HVAC drives

Trailblazer AGZ-E air-cooled scroll chillers

CHAPTER 1. Unit CHA/IK/WP CHA/CLK CHA/ML/ST CHA/ML/ST CHA/ML/ST 182-P 302-P 50-51

Affinity. Dedicated HVAC/R Drive for Building Automation. 1.1kW to 132kW (1.5hp to 200hp) 200V / 400V / 575V / 690V IP20 (NEMA 1) and IP54 (NEMA 12)

Data Centre. Flexible, high efficiency cooling solutions. CONDITIONING CONDENSING UNITS CONTROLS SERVICE TRAINING

Cooling. Highly efficient cooling products for any IT application. For More Information: (866) DATA CENTER SOLUTIONS

Motivair MLC-SC Air-Cooled Scroll Chillers Tons

User Guide. Multipipe Units CMAA / RTMA CNT-SVU004B-GB

Rack cooling solutions for high density racks management, from 10 to 75 kw

Thermostat KP. Data sheet. The KP Thermostats are single-pole, doublethrow (SPDT) temperature-operated electric switches.

Fle F xs le y xs s y C s on C tr on oller

Passive RDHx as a Cost Effective Alternative to CRAH Air Cooling. Jeremiah Stikeleather Applications Engineer

ST-Box THE PERFECT SPLIT SOLUTION

LINE UP LINE UP (RT) ( RCUP75AUZ / 50Hz ) Products Series RCUP-AUZ

Oil Free Magnetic Bearing Chillers. Lloyd Davis ESTech Energy Ltd

Air-Cooled Series R Chiller

BT300 HVAC Drives. Designed for HVAC. Description. Technical Specification Sheet Document No March 4, 2013

Features and Benefits of XeteX Controls. Other Unit Control Functions. Energy Recovery Functions

AHU Solutions Programmable controllers for air handling units

Mission Critical Facilities & Technology Conference November 3, 2011 Cooling 101. Nick Gangemi Regional Sales Manager Data Aire

BUILDING MANAGEMENT. OpenBAS-HV-NX10 SERIES CATALOG NUMBER. Description. Features

DeltaChill & DeltaChill FreeCool kW.

Trane Cold Generator TM. Scroll Chillers. Comfort and Process Cooling Solutions

CGAM air-cooled scroll chiller. Highly efficient, yet extremely quiet

HIGH EFFICIENCY Central Chiller

J&M Fluidics, Inc. Company Product Overview

HIGH DENSITY DATACOM INTEGRATED COOLING SYSTEM.

UNIT CONTROLLER 7 (UC7) Operation & Installation. Hydronic Units

AireFlow kW DX AIR. Data Centre Cooling Product of the Year. Indirect Adiabatic AHU

Smart Equipment Controls (SEC)

Reliability and extended operation

MAKING MODERN LIVING POSSIBLE. ADAP-KOOL Drive. A New Drive for Energy Efficiency AKD 102 REFRIGERATION & AIR CONDITIONING DIVISION

Chilled Water Computer Room Air Handler (CRAH) Critical Infrastructure for the World s Leading Data Centers

UNIT CONTROLLER 8 (UC8) Modbus RTU communications

Liquid Cooling Package LCP Cooling Systems

IT COOLING EVAPORATIVE COOLING SYSTEM. 2 STAGE INDIRECT ADIABATIC COOLING SYSTEM FOR LARGE DATA CENTERS FROM 80 TO 320 kw

Supervisory Controllers

ICS COOL ENERGY THE TEMPERATURE CONTROL SPECIALISTS

BELIMO ENERGY VALVE. Transparent energy monitoring with the Belimo Cloud.

Liquid Cooling Package LCP Cooling Systems

Communication Register Map - Uniflair Cooling

FrigoPack FU+ New Generation of Intelligent Refrigeration Inverters

System Overview. Liquid Cooling for Data Centers. Negative Pressure Cooling Without Risk of Leaks

CGWN/CCUN indoor liquid chillers The compact AquaStream² solution

Rack & Enclosure Systems

OnRak. Up to 35kW. + EER up to Up to 88% less power input + Up to 50% saving in energy * IT Cooling.

Datasheet.

RENNERtronic Plus. higher-level controls. Made in Germany. RENNER compressor controllers. Efficient and reliable. Base load alternation switch K4 K4

Liebert PDX. The Cooling Solution for Small and Medium Data Centers. Digital Scroll. Part Load. Competent Partner Efficiency

MLC Air-Cooled Chillers MLC-FC Free-Cooling Chillers MLC-AD Adiabatic Chillers

VARIABLE REFRIGERANT FLOW SYSTEMS HITACHI SMARTFLEX VRF GEN II FLEXIBILITY, PERFORMANCE AND CONTROL

Extended Digital Controller

Liebert PDX from 15 to 120 kw

Air-Cooled Chillers. R134a. Performance Matters

WHAT IS THE DIGI-RTU South 59 th Street Omaha, NE bes-tech.net

Lab and Central Plant Controller

DX-9100 Digital Controller, Version 2

kyalfa V- VDD/VDD6 General Contents

Precision Cooling Mission Critical Air Handling Units

Evaporative free air cooling technology Providing evaporative free air cooling solutions.

Magnitude magnetic bearing centrifugal chillers

AIR COOLED CONDENSERS

Thermal management. Thermal management

09LD/GD. Air-Cooled Condensers/Air-Cooled Fluid Coolers. Nominal cooling capacity kw 09LD/GD 09GD

Suitable for a wide range of installations with wall-mount, flush-mount and hand-held remote control options.

Keor HPE UPS THREE-PHASE UPS. from 60 to 200 kw GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

FPS SERIES Super Slim Ceiling Mount Air Handling Units

User Guide. For controller on CXAO / RTXB heat pumps CGCM / CXCM 2 circuit units. CNT-SVU005C-GB Original instructions

MOLLIER DIAGRAM CAN BE IMPROVED!

Magnitude magnetic bearing centrifugal chillers

Supplement to PM WSC/WDC-1 MicroTech II for Centrifugal Compressor Water Chillers

Precision Cooling for Business-Critical Continuity. Liebert HPC-M. The Data Center FreeCooling Chiller with the Lowest Impact on the Environment

ENCLOSURE HEAT DISSIPATION

Transcription:

> For the latest information on our products please visit : www.airedale.com > Please refer to the technical manuals for more detailed information Your nearest Airedale distributor is: ISO 14001 EMS52086 ISO 9001 FM00542 Airedale International Air Conditioning Limited Leeds Road, Rawdon Leeds, LS19 6JY, England T : +44 (0) 113 239 1000 F : + 44 (0) 113 250 7219 E : enquiries@airedale.com W : www.airedale.com All specifications are subject to change without prior notice ENG-CHIL-UWC-04-10

s 75-450kW 5-450kW > Ultima Water Cooled & s Typical Applications > Precision Air Conditioning Cooling > Comfort Cooling > Process Cooling www.airedale.com

s Specifications Ultima Water Cooled Chiller & Ultima Remote Air Cooled Chiller The Ultima Water Cooled (UWC) and Ultima Remote Air Cooled Chillers (URAC) are some of the most advanced chillers ever produced by Airedale, thanks to our on-going programme of extensive development and technical innovation. The new ranges have been designed specifically for use in plant room applications with energy efficiency, low sound levels, cost effectiveness and the environment in mind. Heat rejection can be achieved through either water or refrigerant by means of a dry cooler or remote condenser. Key Technical Data > 75kW to 450kW nominal cooling capacity > 45 model sizes > Standard, Quiet and Super Quiet variations > Dual independent refrigeration circuit > All Scroll compressor technology > Compact unit footprint > Optimised for R407C refrigerant Key Feature : Low Sound Levels Airedale recognises that noise pollution is a very important issue in today s populated environments, with many urban areas having already introduced strict noise pollution regulations. The new UWC and URAC have been developed with low sound levels as a key factor in their design. 75 70 UWC / URAC 75-450 kw D DQ Global sound pressure @ 10m 65 60 55 50 DSQ 45 75 100 125 150 175 200 225 250 275 300 325 350 375 400 425 450 kw Page 1

Features & Options Standard Features Through it s use of AireTronix controls the UWC and URAC offer a wealth of energy saving, cost effective features. These features help to provide the necessary internal environment and services expected within an energy efficient, environmentally sound building. > Electronic expansion valves offer significant energy savings > Evaporator pad heater provides frost protection and prevents refrigerant migration when compressors are not in operation > Dual independent refrigeration circuits > High efficiency integrated dual circuit brazed plate evaporator > Advanced AireTronix controller allows intelligent chiller control and full communication to BMS systems > Multiple scroll compressors provide staged capacity control enabling system water volumes to be reduced and part load efficiencies to be increased > Designed and optimised for R407C refrigerant > Liquid and discharge line shut off valves > High efficiency brazed plate condensers (UWC only) > Dedicated compressor enclosure provides good maintenance access while helping to keep noise levels to a minimum (DQ / DSQ models only) > Integral pressure relief valve assembly with indicator gauge (UWC only, option on the URAC) > 0-10V output for control of expansion valves (URAC only) and fans to provide head pressure control > Output to external head pressure controller (FSC or modulating 3-way valve) (UWC only) > Victaulic connections on evaporator (& condenser on UWC) provide low noise, cost savings and a significant reduction in installation & maintenance time Options In addition to their wide range of standard features the UWC and URAC offer a number of enhanced options that can be specified to create a bespoke product that meets each individual customers unique application requirements. > Anti vibration mounts (pad or spring type) for noise sensitive installations > Power factor correction > Electronic soft start significantly reduces the compressor starting current > Evaporator (& condenser on UWC) water filter > Leak detection kit (DQ / DSQ models only) provides an indication of any refrigerant leak within the chiller > Sequence controller for multiple chiller applications > Dual pressure relief valve allows inspection of pressure relief assembly without the requirement to reclaim the system refrigerant > Remote set-point adjust > Evaporator (& condenser on UWC) flow switch (supplied loose) to protect the chiller from damage caused by reduced water flow > Matching dry coolers and air cooled condensers are available for each model size Ultima Water Cooled Chiller DQ / DSQ model with panels removed Page 2

Key Features Key Feature : Electronic Expansion Valves A standard thermostatic expansion valve cannot control the refrigerant superheat and therefore prevent the flow of liquid refrigerant out of the evaporator at low condensing temperatures, so a head pressure controller is fitted to maintain an artificially high head pressure so conventional air handling units can operate reliably, but this means the refrigerant system unit is not running as efficiently as it could do at lower ambient temperatures. The UWC and URAC use electronic expansion valves as standard. The valve can operate at much lower condensing temperatures, reducing the need for unnecessarily high head pressures, and as a result significant compressor energy savings can be achieved whenever the ambient temperature and / or cooling requirements are below design conditions. Reduced condensing pressure Pressure (Bara) Evaporating pressure EXPANSION Bubble Dew Heat of Rejection Cooling COMPRESSOR INPUT POWER Increase in Cooling Duty Enthalpy (kj/kg) Reduction in Compressor Input Power Key Feature : Multiple Scroll Compressor Technology Airedale are utilising multiple scroll compressor technology for the very first time to achieve cooling capacities of up to 450kW on dual circuit machines. The use of this technology brings with it greater flexibility to the Ultima Chiller range. The vertical orientation of the compressors means the UWC and URAC have a more compact footprint than other 450kW chillers, and lower vibration levels means they are quieter than other chillers in this capacity range. The multiple scroll compressors are also considerably more efficient achieving EER values of above 4.0* at nominal conditions, as well as being more resistant to liquid flood back which enhances unit reliability and life cycle costs. * Based on nominal water cooled conditions. Key Feature : Victaulic Pipe work Connections Airedale utilise Victaulic pipe work on the UWC and URAC as standard. These (cost option) clamp type connections have a range of additional features and benefits over the flanges traditionally used on all water connections. > Flexible joint This can accommodate pipe expansion and contraction due to changes in temperature, as well slight misalignments in pipe work, often removing the requirement for expensive on site re-work > Easy maintenance Just two simple bolted connections to make a joint > Noise dampening Through the use of the integrated rubber gasket section of the joint > Even pressure This is evenly applied around the entire pipe, unlike a flanged connection where pressure is focussed on the 10-12 bolt holes > Reduced welding the Victaulic connections greatly reduce time spent welding, and the variety of fittings available can also reduce the amount of welding that is required Cut away section of a victaulic pipework connection Page 3

AireTronix Controls Controller Ultima Water Cooled and Ultima Remote Air Cooled Chillers units are equipped with the very latest microprocessors available from Airedale. These fully programmable controllers are specifically developed for use with Airedale air conditioning systems, offering powerful analogue and digital control to meet a wide range of monitoring and control features. The Controller s in-built display allows viewing of the unit s operating status and it s multi-button keypad allows adjustment to control parameters by allowing the operator easy access to a menu system. Standard Microprocessor Features: > 4 x 20 LCD back lit display > 14MHz 16 bit CPU > 2MB FLASH program memory > 256kB RAM data memory > Remote on / off capability > Compressor anti-cycle control > Compressor rotation > Compressor hours run log and reset > Duty / standby operation > Duty rotation (network units) > Temperature sensors (supply & return) > Visual alarm display > Password protection Connections The controller can be connected and integrated into a wide range of other BMS systems either by using additional internal plug-in serial cards or external gateways. The plug-in serial cards have options to communicate with the following systems Carel, Modbus-Jbus,Trend, Echelon LonWorks devices and Metasys Johnson Controls. With the addition of external gateways the following integration is also available: > BACnet > Fax, SMS and GSM > SNMP (Simple Network Management Protocol) used for Ethernet TCP IP Supervisory Options AireWorks AireWorks is the software program for the Supervision and Monitoring of Chillers & Air-conditioning systems managed by AireTronix controllers. It enables the user to monitor plant or building services, and make changes to the way the building is controlled. AireWorks can act as a server allowing access to a graphical representation using a web browser such as Internet Explorer. AireWeb The AireWeb device is a gateway for interfacing AireTronix controllers to an Ethernet network. The web pages are created based on specific parameters to the installation, be it Airedale Chillers or Air Conditioning units. The user can then display and modify parameters of the installation using standard Internet browsers, by entering an IP address of the AireWeb device. GSM For very simple remote alarm indication, the AireTronix controllers can be fitted with a modem serial card which allows connection to "dual band" type or GSM modems. A recipients mobile telephone number can be entered into the controller, allowing alarms to be sent to any required person. AireWatch For more compact systems, with the same management and control needs as larger areas, AireWatch offers an integrated solution for monitoring, data logging and remote alarm indication and management via an optional inbuilt modem.indication and management via an optional inbuilt modem. Airedale have developed an AireTronix Control Centre at it's corporate headquarters in Leeds. The Centre features live, working AireTronix controllers and AireLan local area networks, and fulfils many functions including full live technical presentations, as well as hands-on and pre-sales product demonstrations for customers. The facility also features a bureau which enables Airedale specialists to conduct remote site monitoring. Page 4

Technical Specifications Ultima Water Cooled Chiller Model No. Nom. Cooling Capacity (kw) Nominal Input Power (kw) EER Global Sound Pressure @ 10m (db(a)) Dimensions (HxLxW), (mm) Operating Weight (kg) UWC75D 87.5 22.0 4.0 53 1850 x 1800 x 760 810 UWC100D 118.9 29.3 4.1 51 1850 x 1800 x 760 875 UWC125D 152.0 37.4 4.1 54 1850 x 1800 x 760 910 UWC150D 184.2 45.0 4.1 53 1850 x 2000 x 760 1280 UWC175D 213.1 50.7 4.2 55 1850 x 2000 x 760 1385 UWC200D 242.9 56.9 4.2 57 1850 x 2000 x 760 1490 UWC225D 273.7 64.5 4.2 61 1850 x 2000 x 760 1585 UWC240D 262.2 62.9 4.2 62 1900 x 3200 x 900 1800 UWC250D 306.3 72.0 4.3 63 1850 x 2000 x 760 1660 UWC270D 305.9 72.2 4.2 63 1900 x 3200 x 900 1980 UWC300D 351.4 81.5 4.3 63 1900 x 3200 x 900 2180 UWC330D 396.1 92.4 4.3 67 1900 x 3200 x 900 2300 UWC360D 441.6 103.3 4.3 70 1900 x 3200 x 900 2420 UWC400D 486.0 116.1 4.2 70 1900 x 3200 x 900 2620 UWC450D 528.6 128.7 4.1 71 1900 x 3200 x 900 2820 UWC75DQ 87.5 22.0 4.0 49 1850 x 1800 x 760 840 UWC100DQ 118.9 29.3 4.1 47 1850 x 1800 x 760 905 UWC125DQ 152.0 37.4 4.1 50 1850 x 1800 x 760 940 UWC150DQ 184.2 45.0 4.1 49 1850 x 2000 x 760 1310 UWC175DQ 213.1 50.7 4.2 51 1850 x 2000 x 760 1415 UWC200DQ 242.9 56.9 4.3 53 1850 x 2000 x 760 1520 UWC225DQ 273.7 64.5 4.2 57 1850 x 2000 x 760 1625 UWC240DQ 262.2 62.9 4.2 61 1900 x 3200 x 900 1880 UWC250DQ 306.3 72.0 4.3 59 1850 x 2000 x 760 1690 UWC270DQ 305.9 72.2 4.2 61 1900 x 3200 x 900 2060 UWC300DQ 351.4 81.5 4.3 60 1900 x 3200 x 900 2240 UWC330DQ 396.1 92.4 4.3 65 1900 x 3200 x 900 2380 UWC360DQ 441.6 103.3 4.3 67 1900 x 3200 x 900 2500 UWC400DQ 486.0 116.1 4.2 68 1900 x 3200 x 900 2680 UWC450DQ 528.6 128.7 4.1 68 1900 x 3200 x 900 2900 UWC75DSQ 87.5 22.0 4.0 48 1850 x 1800 x 760 880 UWC100DSQ 118.9 29.3 4.1 46 1850 x 1800 x 760 945 UWC125DSQ 118.9 37.4 3.2 49 1850 x 1800 x 760 970 UWC150DSQ 184.2 45.0 4.1 48 1850 x 2000 x 760 1350 UWC175DSQ 213.1 50.7 4.2 50 1850 x 2000 x 760 1455 UWC200DSQ 242.9 56.9 4.3 52 1850 x 2000 x 760 1560 UWC225DSQ 273.7 64.5 4.2 56 1850 x 2000 x 760 1655 UWC240DSQ 262.2 62.9 4.2 60 1900 x 3200 x 900 1900 UWC250DSQ 306.3 72.0 4.3 58 1850 x 2000 x 760 1730 UWC270DSQ 305.9 72.2 4.2 59 1900 x 3200 x 900 2080 UWC300DSQ 351.4 81.5 4.3 57 1900 x 3200 x 900 2280 UWC330DSQ 396.1 92.4 4.3 62 1900 x 3200 x 900 2380 UWC360DSQ 441.6 103.3 4.3 64 1900 x 3200 x 900 2500 UWC400DSQ 486.0 116.1 4.2 65 1900 x 3200 x 900 2720 UWC450DSQ 528.6 128.7 4.1 66 1900 x 3200 x 900 2900 Nominal capacities based on evaporating 7/12 C, 30/35 C condenser water, 100% water Page 5

Technical Specifications Ultima Remote Air Cooled Chiller Model No. Nom. Cooling Capacity (kw) Nominal Input Power (kw) EER Global Sound Pressure @ 10m (db(a)) Dimensions (HxLxW), (mm) Operating Weight (kg) URAC75D 83.2 23.4 3.6 53 1850 x 1800 x 760 790 URAC100D 113.4 31.2 3.6 51 1850 x 1800 x 760 830 URAC125D 145.3 39.4 3.7 54 1850 x 1800 x 760 860 URAC150D 175.6 47.7 3.7 53 1850 x 2000 x 760 1190 URAC175D 202.5 54.3 3.7 55 1850 x 2000 x 760 1290 URAC200D 230.6 61.1 3.8 57 1850 x 2000 x 760 1380 URAC225D 258.8 69.3 3.7 61 1850 x 2000 x 760 1450 URAC240D 248.2 70.1 3.5 62 1900 x 3200 x 900 1540 URAC250D 287.3 77.2 3.7 63 1850 x 2000 x 760 1520 URAC270D 289.5 80.7 3.6 63 1900 x 3200 x 900 1680 URAC300D 331.5 91.3 3.6 63 1900 x 3200 x 900 1820 URAC330D 373.3 102.8 3.6 67 1900 x 3200 x 900 1900 URAC360D 415.8 114.4 3.6 70 1900 x 3200 x 900 1980 URAC400D 459.0 128.7 3.6 70 1900 x 3200 x 900 2120 URAC450D 502.4 143.1 3.5 71 1900 x 3200 x 900 2280 URAC75DQ 83.2 23.4 3.6 49 1850 x 1800 x 760 810 URAC100DQ 113.4 31.2 3.6 47 1850 x 1800 x 760 855 URAC125DQ 145.3 39.4 3.7 50 1850 x 1800 x 760 880 URAC150DQ 175.6 47.7 3.7 49 1850 x 2000 x 760 1230 URAC175DQ 202.5 54.3 3.7 51 1850 x 2000 x 760 1325 URAC200DQ 230.6 61.1 3.8 53 1850 x 2000 x 760 1425 URAC225DQ 258.8 69.3 3.7 57 1850 x 2000 x 760 1490 URAC240DQ 248.2 70.1 3.5 61 1900 x 3200 x 900 1620 URAC250DQ 287.3 77.2 3.7 59 1850 x 2000 x 760 1555 URAC270DQ 289.5 80.7 3.6 61 1900 x 3200 x 900 1760 URAC300DQ 331.5 91.3 3.6 60 1900 x 3200 x 900 1900 URAC330DQ 373.3 102.8 3.6 65 1900 x 3200 x 900 1960 URAC360DQ 415.8 114.4 3.6 67 1900 x 3200 x 900 2060 URAC400DQ 459.0 128.7 3.6 68 1900 x 3200 x 900 2180 URAC450DQ 502.4 143.1 3.5 68 1900 x 3200 x 900 2340 URAC75DSQ 83.2 23.4 3.6 48 1850 x 1800 x 760 845 URAC100DSQ 113.4 31.2 3.6 46 1850 x 1800 x 760 890 URAC125DSQ 145.3 39.4 3.7 49 1850 x 1800 x 760 915 URAC150DSQ 175.6 47.7 3.7 48 1850 x 2000 x 760 1265 URAC175DSQ 202.5 54.3 3.7 50 1850 x 2000 x 760 1360 URAC200DSQ 230.6 61.1 3.8 52 1850 x 2000 x 760 1455 URAC225DSQ 258.8 69.3 3.7 56 1850 x 2000 x 760 1525 URAC240DSQ 248.2 70.1 3.5 60 1900 x 3200 x 900 1620 URAC250DSQ 287.3 77.2 3.7 58 1850 x 2000 x 760 1590 URAC270DSQ 289.5 80.7 3.6 59 1900 x 3200 x 900 1780 URAC300DSQ 331.5 91.3 3.6 57 1900 x 3200 x 900 1900 URAC330DSQ 373.3 102.8 3.6 62 1900 x 3200 x 900 2000 URAC360DSQ 415.8 114.4 3.6 64 1900 x 3200 x 900 2060 URAC400DSQ 459.0 128.7 3.6 65 1900 x 3200 x 900 2220 URAC450DSQ 502.4 143.1 3.5 66 1900 x 3200 x 900 2360 Nominal capacities based on 7/12 C, 100% water 45 C dew condensing temperature. Page 6