Data Sheet SS/_ Inform IT Single Pen Circular Chart Recorder Universal process input ma, mv, V, thermocouples and resistance Signal linearization full range of linearizers included as standard -digit indicator panel continuous display of process value NEMA X/IP construction hosedown protection Optional Totalizer function 8-digit Flow totalizer a rugged, reliable recorder for all single channel recording applications
SS/_ The is a single pen, fully programmable circular chart recorder. The instrument s straightforward operator controls and robust construction make it suitable for a variety of industrial environments. Easy to Install A choice of mounting options enables simple installation of the recorder in a panel, on a wall or on a pipe. Mains isolation can be provided by an optional power switch within the instrument. Designed to Survive NEMA X protection ensures the can survive in the harshest environments and makes the recorder ideal for use in panels which are regularly hosed down. The tough, acidresistant case and secure cable-entry glands maintain the NEMA X rating for wall-mount or pipe-mount instruments. Optional Wall-/Pipe-mounting Accessories Part no. C1900/0712 Optional Case-to-Panel Gasket Part no. C1900/019 2
SS/_ Specification General Construction Size Weight Case material Window Material Door latch 15.2 in. (h) x 15.0 in. (w) x 5.57 in. (d) (8.8 x 128.0 x 11.5mm) 18lb (8.2kg) Glassfiber-filled reinforced polyester Polycarbonate High-compression with optional lock Environmental Operational temperature range 2 to 10 F (0 to 55 C) Operational humidity range 5 to 95%RH (non-condensing) 5 to 80%RH (chart only) Case sealing NEMA X (IP) Fast transients IEC 801- Level Installation Mounting options Terminal type Wire size (max) Panel, wall or pipe Screw 1 AWG (I/O), 12 AWG (power) Operation and Configuration Programming method Via front panel keys Security Password protected menus Safety General safety Isolation Memory protection Approvals CE CSA CSA/FM Class 1 Div. 2 UL Power Supply Voltage Consumption Line interruption Totalizer Size Count direction Preset IEC8 2kV DC (channel/ground) Nonvolatile EEPROM (option) (option) (option) 115/20V AC ±15%, 50/0Hz <0 VA Up to 0ms 99,999,999 max. Up or down User-programmable Process Input General Noise Rejection CJC rejection ratio Sensor break protection Out of range detection Temperature stability Long-term drift Input impedance Common mode >120dB at 50/0Hz Normal (series) mode >0dB at 50/0Hz <0.05 C/ C Upscale or downscale drive 0 to 100% of engineering span <0.02% of reading/ C or 1µV/ C <0.01% of reading 10µV annually >10 MΩ (mv and V inputs) 100 Ω (ma input) Analog Input Signal types mv, V, ma, Ω Thermocouple types B, E, J, K, N, R, S, T Resistance Thermometer Pt 100 Other linearizations x /2, x 5/2, square root Sample interval 250ms Digital Filter 0 to 0s programmable Recording System Pen Color Response Resolution Pen lift Chart Chart size Chart speed Red 7 seconds (full scale) 0.1% steps Motor-driven, with optional auto-drop 10 in. or 105mm 1 to 17 hours or 7 to 2 days per revolution Display and Operator Panels Displays Type -digit red LED, 0.5 in. (1mm) high Panel keys Function Programming access, increment/decrement, pen lift and user-defined function key.
SS/_ Analog Input Performance Type V Range Low Range High Min. Span Accuracy m 0 150 5 ± 0.1% reading or 10µV V 0 5 0. 1 ± 0.1% reading or 20µV ma 0 50 1 ± 0.2% reading or 0. 2µA Ohms (low) 0 750 20 ± 0.2% reading or 0. 1Ω Ohms (high) 0 10k 00 ± 0.5% reading or 10Ω C F Type Range Low Range High Range Low Range High Accuracy (excl. CJC) B 18 1800 0 270 ± 2. 0 C (above 200 C) E 100 900 10 150 J 100 900 10 150 K 100 100 10 250 N 200 100 25 250 R 18 1700 0 000 ± 1. 0 C (above 00 ) S 18 1700 0 000 ± 1. 0 C (above 200 C) T 250 00 00 550 Pt100 200 00 25 1100
Single Pen Circular Chart Recorder SS/_ Wiring Connections Power Switch and Fuse + + + Voltage Thermocouple Low Voltage (mv) Current + 5 -wire RTD Red White Red 5 Link White Red 2-wire RTD and Resistance Line Neutral Ground Standard Input Connections Power Supply Connections 5
SS/_ Overall Dimensions Dimensions in mm (in.) 15.0 (82) 15.2 (8) 1.0 () 2.0 () 1.8 (5) Typical Space Between Adjacent Knockout Centers 7.22 (18.) 12. (20.8) 1. (.) 0.88 (22.5) 12. (20.8)
SS/_ Ordering Information Single Pen Circular Chart Recorder 1901 X X 0 X X X 0 0 0 0 0 XXXX Chart Type Build Taylor (ER/C) charts KPC 105, Kent PX and Kent PXR type charts Chessel brand charts ABB Standard CSA approved CSA/FM Class 1 Division 2 approved UL approved Options None Totalizer Door Lock Not fitted Fitted Power Supply 115V AC 20V AC 115V AC with On/Off switch 20V AC with On/Off switch Programming/Special Features Configured to factory standard Configured to customer requirements Special features J K C A B F U 0 1 2 1 2 5 STD CUS SPXX 7
SS/_ ABB has Sales & Customer Support expertise in over 100 countries worldwide www.abb.com The Company s policy is one of continuous product improvement and the right is reserved to modify the information contained herein without notice. Printed in UK (09.02) ABB 2002 SS/ Issue ABB Inc. 125 E. County Line Road Warminster PA 1897 USA Tel: +1 215 7 000 Fax: +1 215 7 718 ABB Limited Howard Road, St Neots Cambridgeshire PE19 8EU UK Tel: + (0)180 7521 Fax: + (0)180 21798