Quick Reference Guide. DHAtoD86

Similar documents
OpenLAB CDS Match Compare. Software tool for OpenLAB CDS Ideal for flavors/fragrance analysis. A May 2013

Retention Time Locking with the MSD Productivity ChemStation. Technical Overview. Introduction. When Should I Lock My Methods?

Agilent SimDis System

TraceFinder Analysis Quick Reference Guide

Galaxie Photodiode Array Software

Chromeleon software orientation

Fatty Acid Methyl Ester (FAME) RTL Databases for GC and GC/MS

Agilent MassHunter LC/SQ ChemStation Integration Software

[ WHITE PAPER ] System Policies and Privileges for Processing Data in Empower Software with Data Integrity in Mind INTRODUCTION

Data Handling and Reports

Agilent MassHunter Qualitative Data Analysis

How to Run the CASPiE GCMS

Agilent 7890 Series Gas Chromatograph

Data Acquisition with CP-2002/2003 Micro-GC Control

Operation of the Toxic Organic Chemical Air Monitor (TOCAM ) with the Ellvin Chromatography Software

Agilent OpenLAB CDS ChemStation Edition

Retention Time Locking Operation

Procedures for Group Quantitation

ChromQuest 5.0 Quick Reference Guide

FlowAccess TM GETTING STARTED. Windows software for Skalar SAN plus systems. Version and up

Agilent G2070BA GC ChemStation

POWER WORLD LAB MANUAL

Finite Differencing Using Excel Learning how to use Surface Charts T 1 T 4 T 2 T 3

TraceFinder Analysis Quick Reference Guide

Quant Browser for the Agilent Technologies GCMS Chemstation

CLARITY DEMO. Clarity Demo Software. Code/Rev.: M003/70E Date:

Clarity. Clarity Demo. Code/Rev.: M003/60A Date: Fax: Petrzilkova 2583/ Prague 5

Impact Analysis for Software changes in OpenLAB CDS A.01.04

Agilent OpenLAB CDS ChemStation Edition

EnCal 3000 Gas Chromatograph Software Manual d

ABB Analytical ABB Process Analytics. VistaII. Model 2000 Process Gas Chromatograph

IR Group 1 - carbonyl compounds (R = alkyl branch, Ar = aromatic branch)

Sniffer 9100 Series. GC-O GC/MS-O, State of the art... GC-Olfactometry Method for Food, Flavor and Fragrances. Principle

Store and Report Waters Empower Data with OpenLAB ECM and OpenLAB ECM Intelligent Reporter

Agilent MassHunter Workstation Software Report Designer Add-in

Files and Folders What are Files and Folders Files: This is the Data, Images, and things the user makes

Color Process Control and Verification in Fiery proserver and Fiery XF

Process gas chromatography

To get started download the dataset, unzip files, start Maven, and follow steps below.

Chemical Analysis Group Gas Chromatograph Common Cabling \ Pin-outs Document A15707

Majors & SSCH by Department Dashboard Guide

STEP 1: PREPARE FOR DATA MIGRATION 1. Right-click the desktop and choose New > Folder. a. Type For Transferring and press Enter to name the folder.

Software for Gas Chromatographs , Rev G May 2017 MON2020. Applies to all Emerson XA Series Gas Chromatographs

IT Essentials v6.0 Windows 10 Software Labs

Win1010 Contest Program - Getting Started

Working with PDF s. To open a recent file on the Start screen, double click on the file name.

Using SIMDIS Expert 9 (Separation Systems) with Clarity

Multivariate Calibration Quick Guide

REVIEW. MassFinder 3. Navigation of the Chromatogram

An Introduction to Autodesk Revit Massing, Surface Divisions, and Adaptive Components

The Item_Master_addin.xlam is an Excel add-in file used to provide additional features to assist during plan development.

QromaTag for Mac. User Guide. v1.0.5

NetProfiler 2 SpectroEye Guide Version 1.0

Quick Start Guide. Introduction. Importing Raw Data. Method 1: Use Open Data Panel

B03 Guided Interpretation #3

Preliminary Lab Exercise Part 1 Calibration of Eppendorf Pipette

Step 1 Turn on the device and log in with the password, PIN, or other passcode, if necessary.

Agilent 6400 Series Triple Quadrupole LC/MS System

Guidelines for Setting Auto-Peak Width in ApexTrack Processing Methods and its Effect on USP Resolution and USP Plate Count

Chromeleon / MSQ Plus Operator s Guide Document No Revision 03 October 2009

StarFinder. Operation Manual. Star Chromatography Workstation Version 6

EZ IQ. Chromatography Software PN P1A

Skyline High Resolution Metabolomics (Draft)

Nasuni Mobile Access User Guide

HP SmartTracker. User Guide

Desktop Studio: Charts. Version: 7.3

Agilent MassHunter Drug Analysis Mode Using Quantitative Analysis Workflow Guide

Agilent ChemStation Plus

Agilent MassHunter Workstation Software 7200 Accurate-Mass Quadrupole Time of Flight GC/MS

MOVING AND COPYING DATA...

MICRO GC FUSION Micro GC Fusion 3/17/2014 1

Creating/Updating Finding Aids in ArchivesSpace

Verisurf Analysis. Verisurf Analysis 1

Instruction Manual XLComm Data Acquisition Software For XL Series Meters

Agilent G2727AA LC/MS Data Browser Quick Start

SMAC Control Center Training v1.2. The Ability to do Work & Verify it s Accuracy at the Same Time

MYOB Accountants Office

For the Beginner: c) Click the settings tab to set screen resolution d) Set resolution with slider bar.

Agilent OpenLAB Chromatography Data System A SR1 - Updates

To NeSSi or Not to NeSSi: A Fast and Micro GC Experience Review

Lab - System Restore in Windows 8

Desktop Studio: Charts

Samples Preparing the GC to run samples Running samples - Manual Injection Running samples - GC ALS or Valve Injection

3. Map Overlay and Digitizing

CRM CUSTOMER RELATIONSHIP MANAGEMENT

MIMA V 1.0. MS IMS Mapper. Peak Identification in Ion mobility Spectrometry

equinux AG and equinux USA, Inc.

Brooke Roegge. Digital Information Specialist Minnesota Dept. of Employment and Economic Development

Integration of GC/MSD ChemStation with OpenLAB ECM

Agilent G1732BA MSD Security ChemStation

UPGRADE INSTALLATION PROCEDURES

Soprane II Documentation

Building Agilent GC/MSD Deconvolution Reporting Libraries for Any Application Technical Overview

Galaxie Workstation Configuration Manager

Excel. Dashboard Creation. Microsoft # KIRSCHNER ROAD KELOWNA, BC V1Y4N TOLL FREE:

5973 Network Mass Selective Detectors

d95f-41eb-addd- 5e6eff41b083

Optimizing System Dispersion on the Agilent 1290 Infinity II LC

MCA 1400 Documentation

Maxum Workstation Update Release Notes

Transcription:

DHAtoD86 www.stillpeaks.com StillPeaks DHAtoD86 software consists of 3 apps that read peak integrator data from Chromatographic Data Systems (CDS) and calculate a D86 report of your sample: Virtual GC is a computer model of a Dimethylsilicone coated capillary gas chromatographic column. Temperature programmed Kovats index databases and n-paraffin retention times are calculated from GC configuration input and an isothermal Kovats index database. The GC configuration should match the actual GC configuration. Copy the Virtual GC window to your lab journal to keep track of the configuration especially the film thickness that reduces on aging. DHA Detailed Hydrocarbon Analysis software reads the GC integration file. Peaks are identified by shortlist, pattern and Kovats index database. From DHA, Virtual GC and D86 can be started. D86 The Fugacity-Film model uses the DHA output of the sample to calculate the distillation curve of the sample. The D86 report is shown on screen and written to the sample folder. To keep the same numbers, you can enter physical ASTM D86 distillation data to calculate offsets. Offsets are managed per sample type (Alkylate, Isomerate, Reformate, Naphtha s FCC s, Winter & Summer gasoline). Content 1.DHA Detailed Hydrocarbon Analysis... 2 2.Virtual GC: n-paraffin Times & Kovats Index... 4 3.DHA Peak Identification... 6 4.D86 Sample Type Setpoints... 7 5.D86 Property Units and Thermometer Shift... 9 6.D86 Calculation and Setpoint Adjustents... 9 7.D86 Physical Data Input... 14 1

1.DHA Detailed Hydrocarbon Analysis StillPeaks DHA is based on the Kovats index. The DHA opening screen is empty: The Kovats index is retention time relative to the n-paraffins displayed in the nparaffins tabsheet: StillPeaks DHA uses precalculated nparaffins. The following 3 peak identification strategies are followed: 1. Overloaded peak ID from a shortlist of compounds, 2. Pattern recognition, 3. Kovats index matching. 1.Typical shortlists of major peaks expected in sample types are given in the Types tabsheet: Use i-paraffins for Alkylates and Isomerates. 2.The following 3 patterns can be recognized: The Alkylate peaks I8: 2

The Xylenes A8: And the C9 aromatics: 3.Type selection selects the Kovats index database as well: 3

2.Virtual GC: n-paraffin Times & Kovats Index Use directory tree at the left side to select your ChemStation or OpenLab analysis sequence. The chromatogram at the right side displays the integrator results of a selected sample in the samples list: The white slice of the small circle at the left bottom of the chromatogram indicates almost 15% of the sample peaks are not identified. All 3 patterns are recognized in this sample. The right side tab sheet lineup shows the measured GC peak times and peak Area of sample RFG 0210 located in the path displayed in the window title. The peak identity result is shown in the 4 th column. On the TPGC method tabsheet the Virtual GC button: Clicking the Virtual GC button you can adjust the TPGC method so the chromatograms look like the calculated ones. Selece the save option to write Kovats database and n-paraffins to the DHA: 4

Times and databases are filed. The n-paraffin times and databases are applied in DHA only after clicking the Read Alkanes button in the DHA app. 5

3.DHA Peak Identification The Peak ID pie chart has a red part for the big peaks, a yellow part for the pattern recognition, a blue part for the small peaks with Kovats index and a white part for the unidentified peaks. In this sample 13 peaks have Area% > 2, corresponding 35% red part of the pie chart: The left hand tab sheet Print is selected, where the hard coded I8 pattern is selected. This pattern is recognized in this sample and marked with I8. The yellow part of the ID pie indicates that about 20% of the peaks in this sample are identified by peak recognition of the Iso-octanes (I8), Xylenes and Ethylbenzene (A8, A9). NOTE The D86 curve button appears only if less than 50% of the peaks is unknown. 6

4.D86 Sample Type Setpoints Clicking the D86 button opens the D86 page, showing the sample and available D86 data: The sample has been recognized as Summer Spec gasoline and the ASTM D86 cross check data are displayed at the left side. The setpoints and offsets for this summer gasoline are found in the D 86 Offset tabsheet: ASTA can be switched off by unchecking the Automatic Sample Type Assignment checkbox: 7

The ASTA check will stay checked or unchecked. Now waith ASTA unchecked, all sampletype specific setpoints can be selected allowing you to run a gasoline with reformate setpoints. The setpoint selection and the value of the setpoints is retained in the D86 software. Tsample is the Sample Temperature, Theater is the heater temperature before IBP. The offset shown at the right side can be applied to the final D86 report by checking the Offset checkbox: With this check, the offsets are applied to the final D86 caculation. Offset is found by entering ASTM D 86 data and can be applied to tune DHAtoD86 even closer to your D 86 numbers. 8

5.D86 Property Units and Thermometer Shift The units of the properties P, T and density can be selected in the Units tabsheet. Eö is a dimensionless number, related to droplet size. The bigger the droplet at the virtual thermometer tip, the lower the temperature. The Eö number shifts the calculated D86 curve down. Any changes are saved and applied ever after. Droplet size can be restored to default values by hitting the default values button. 6.D86 Calculation and Setpoint Adjustents The Eö number from chapter 5 is much too high, shifting the calculated D86 curve down: So we hit the default values button (chapter 5, Eö = 1) and re-run the D86: 9

Maybe Eö = 1.666 is better: Now we have 10 temperatures within the -2<z<2 range. The IBP is overestimated, so we take an initial heater temperature of 400 C: 10

The repair of the 10% may be found by adding another 25 C to Theater: Next we change the Delay setpoint and the Eo number in a last effort to get closer to the ASTM D 86 data: 11

To repair the last differnces, offset is refreshed by clicking the Refresh Offset, and we the result is: The offset values are the negative values of the G-D data column in above D86 report. When we recalculate using these offsets we get: 12

As expected, exactly the correct values, because the RFG 0210 offsets are used. 13

7.D86 Physical Data Input Physical D86 data can be entered to determine the setponts and the offsets of a sample type: The entry of data should be evaporated data beginning with IBP a number of volumes and temperatures ending with FBP. Hit save to store this data with the samplename for later reference. Every following calculation with the same sample name will be compared to these distillatin data. Sample names and data can be removed from the file D86evaporateDHAtoD86.txt. Only evaporated data and crosscheck data can be entered, the recovered data entry is not yet implemented. 14