OPERATION INSTRUCTIONS

Similar documents
NOTE CONTENTS NOTE-CONTENTS

REMOTE CONTROLLER OWNER'S MANUAL AIR CONDITIONER OWNER'S MANUAL ATI/AOU-53HPR1 ATI/AOU-105HPS3 ATI/AOU-140HPS3

Wall mounted units. Please read carefully and thoroughly this manual before operating this unit and save it in a safe place for future reference.

V0STAT51P-2 Programmable Wired Controller

REMOTE CONTROLLER CS244-R OWNER S MANUAL

Chilled Water REMOTE CONTROLLER OPERATION MANUAL MAN-O-CRC4AH intensity.mx

REMOTE CONTROL USER MANUAL QUICK CONNECT MINI-SPLIT

Owner s Manual RBC-AX32U(W)-E RBC-AX32U(WS)-E AIR CONDITIONER (SPLIT TYPE) Wireless remote controller kit. Model name: English.

LVM Touch Screen Centralized Controller

OWNER S MANUAL WIRE CONTROLLER OF AIR CONDITIONER. MODEL: KJR-12B/DPBG(T)-E Brivis Part No:B026000

Ασύρματο Τηλεχειριστήριο YB1FA

IntesisBox. v.0.1. User Manual Issue Date: 12/2017 r1.3 EN

Portable Room Air Conditioner Remote Control for:

WIRED REMOTE CONTROLLER OPERATION MANUAL

Wired Controller Operation & Installation Manual

Central Controller Operation & Installation Manual

Owner's Manual. Carrier TOSH BA REMOTE CONTROLLER FOR AIR CONDITIONER (SPLIT TYPE) Wireless remote controller kit TCB-AX21 UL

Dryer. M720 Programming and Operation Manual. July 15, 2015 Revision 1.51

Wireless Remote Controller Kit

Operation Guide CT100

Model Instruction Manual. Heat Stress Meter. reedinstruments. www. com

76 F. Ductless Split Air Conditioner. YR-E16b Wired Controller User Manual WARNING

Operation 6035 ENGLISH PROG MENU

Quick Start. MyAir4 User Manual. This section will give you a brief description about each of the buttons found on the home screen.

Super Digital Inverter / RAV Series 2010 Technical training

SPECIFICATIONS Temperature Setting Range: Ambient Temperature Humidity Display Range: Screen lock & configuration password:

Part 6 Control System

SINGLE. Technical Data Book Zone Control Systems

Daikin HVAC Controls Guide Specification

Model: Available in : Sapphire Black and Glacier White

*520886* IntelliTouch Pool & Spa Control System MobileTouch Wireless Controller. User s and Installation Guide. P/N Rev A

MAXDTC-BT Family User Manual

IntesisBox ModBus RTU Fujitsu Air Conditioning

24/7 Sprinkler Monitor. The Ultimate Rain/Freeze Sensor

IntesisBox. v.2.5. User Manual Issue Date: 12/2017 r1.9 EN. Modbus RTU (EIA-485) Interface for Fujitsu air conditioners.

Operation Guide CT32 ENGLISH

Installation, Start-up and Operating Instructions

Model: Available in : Sapphire Black and Glacier White

ARCTIC AIR DC OLED. Digital Control Operations Manual

INTERFACE SPECIFICATION

REMOTE CONTROL MYSYSTEM

USER'S MANUAL. IntesisBox KNX K01-KNX-1B/16/64 v1.0. r1 eng Issue Date: 2014/06

900-4RL Option Board. Refer to installation instructions for compatible supply models - PS902, PS904, PS906, and PS914. Note

IntesisBox PA-AC-MBS-1

Daikin HVAC Controls Guide Specification

OM-DLTT DATA LOGGER INSTRUCTIONS

BACnet Gateway V0CTRL86P Lennox VRF, Mini-VRF and Mini-Split

Operation Guide CT101

MXM-50. Modbus Interface for Mitsubishi Air-Conditioning. Installation and User Guide.

AirPatrol WiFi Version 2 Full Manual V4.2

Installation Manual. DZK BACnet

The PanasonicVRF Driver

OK - Functions of the buttons. = "Arrow up" = ON / OFF. = Enter. = Temperature. ="Arrow down" = Preset time / Start time.

Instruction Book. English. CITY MULTI Control System and Mitsubishi Mr. Slim Air Conditioners MA Remote Controller PAR-30MAA

QUICK REFERENCE. Remote controller BRC1E51

TEMPERATURE CONTROLLER 2 HEAT/ 2 COOL with Digital Room Temperature Display. Made in Australia 100% Australian Owned Company

Instruction Book. English. CITY MULTI Control System and Mitsubishi Mr. Slim Air Conditioners MA Remote Controller PAR-31MAA

Deluxe In/Out Remote Thermometer with Trend Chart

KNX is a European Standard Protocol used for household and industrial Buliding Management System (BMS).

Brivis Programmable Controller OWNER S MANUAL

Zone Manager INSTALLATION MANUAL 40KMC KMQ QNC QNQ

USER MANUAL MINI WILDLIFE CAMERA

VRF Control System. Judy Ouyang Technical Support Engineer

Communicating Wall Control Owner s Manual TSTAT0101SC

Series SD-3PB Digital THERMOSTAT + TIMER

IntesisBox PA-AW-MBS-1 v.2.0

M U L TI - SP ORT SCOREBOARD

OPERATION MANUAL. Remote controller BRC1D527

Viconics VT76x6W Water-source Heat Pump Controllers Engineering Guide Specification

NVR Security System Quick Start Guide

IntesisBox SMS - Mitsubishi Electric air conditioners

Pocket Quick Reference Guide On the TOSHIBA

Table of Contents. Model: -hw. -hw. Series. Available in : Sapphire Black and Glacier White. Product Image. 16 Table of Contents

Supplied with. Calibration certificate. HD 200 Hygrometer

IS-IR-WIFI-1 User Manual

IntesisBox TO-RC-MBS-1

Prime Capsule Portable Data Logger

When Not in Use: Remove the batteries if this device is to be left unattended or unused for a long period of time.

Brivis Touch. Owner s Manual

BACVIEW MANUAL Software Version 3.06 INSTALLATION AND OPERATION MANUAL

REMOTE CONTROLLER RG57 Function Selection Manual

RBC-AMS55E-ES RBC-AMS55E-EN

Product Manual SZ2141

PLXRMM1605. Wall Mounted. FT-A Series. COOLING ONLY [50Hz] V

RBC-AMT32E / RBC-AMS41E

smartentry Wireless Video Doorphone User Manual

I2:34 MODEL TSTATBBP2W01 PROGRAMMABLE DIGITAL THERMOSTAT. Heat only, or Cool only. Meets California Title 24 Residential USERS INFORMATION MANUAL

Central Controller G-50A/GB-50 Web Browser Operation Manual (For Managers)

Daikin HVAC Controls Guide Specification

Home Monitoring and Control service provided by Verizon Online LLC

OM-DLTH DATA LOGGER INSTRUCTIONS

AUGUST 2017 SUG/U 1.1 Split Unit Gateway Product presentation. STO/GPS, Product Management

3. Alignment and Adjustments

4-20 ma Current Data Logger

UC102 basic version with display and knob UC102BL version with display, knob and backlight UC102DK version without knob and display

VRF. Technical Data Book. Control System

Indoor Air Quality Meter/Datalogger

technical data Systems Individual control systems

ARA FTS Flow Calibrator. Operation Manual August 1, 2016

Brivis. Ducted Reverse Cycle Inverter. Wired Programmable Controller OWNERS MANUAL

Transcription:

2018 Lennox Industries Inc. Dallas, Texas, USA OPERATION INSTRUCTIONS V0STAT52 Wireless Indoor Unit Controller CONTROLS 507459-04 05/2018 This manual must be left with the owner for future reference. IMPORTANT Frequent changes to operating mode may cause system malfunction. Allow at least one minute between mode changes to allow the system to stabilize. Shipping and Packing List Package 1 of 1 contains; 1 Wireless Controller 2 AAA batteries 1 Remote controller holder with mounting screw 1

General The V0STAT52 is a wireless local controller for VRF Heat Pump and Heat Recovery indoor units. Requirements Point the wireless remote controller directly at the indoor unit it controls. 36 ft. (11 m) maximum distance. Wireless remote control requires direct line of sight to indoor unit. Do not get wireless remote controller wet or submerge in liquid. Avoid placing wireless remote controller in direct sunlight or high temperature locations. Always use new AAA batteries. Remove the batteries if the wireless remote controller will not be used for a long period of time. Replace the batteries if the indoor unit does not beep when settings are changed using the controller. Do not attempt to operate any other devices using this remote controller. Specifications Rated voltage Min voltage for sending signal to CPU 3.0 VDC (2 AAA batteries) 2.4 VDC Effective transmitting distance 26-36 ft (8-11 m) Operation conditions 23 F - 140 F 2

Function Buttons Power Mode Down-arrow AUTO COOL DRY HEAT FAN MODE M TEMP SET CLOCK SET HOUR FANS PEED FAN SPEED Fan speed Up-arrow Air direction Vertical Swing SWIN G AIR DIRECTION CLOCK Clock Horizontal Swing SWIN G RESET LOCK C/H OK ECO TIMER ON TIME R OFF Timer ON Timer OFF Reset Lock Cool/Heat OK Eco mode (not used) 3

Power button. Press to turn the indoor unit on or off. Mode button. Press to scroll through the operation modes: Auto Cool Dry Heat Fan. NOTE - Auto mode not available in all systems. Down-arrow. Press to decrease the temperature setpoint or scroll through settings options. Vertical Swing button. Press once to initiate louver up & down oscillation. Press again to stop louver oscillation. Louvers remain in place where stopped. Not available in all indoor unit models. Horizontal Swing button. Press once to initiate louver left & right oscillation. Press again to stop louver oscillation. Louvers remain in place where stopped. Not available in all indoor unit models. Reset button. Using a blunt pointed device (paper clip), press to cancel current settings and reset remote controller to factory settings. Lock button. Using a blunt pointed device (paper clip), press to lock or unlock the current setting. Cool/heat button. Using a blunt pointed device (paper clip), press to shift between Cool only and Cool & Heat modes. Default is Cool & Heat. Fan speed. Press to scroll through the fan speeds: Low Med High NOTE - Auto fan speed not available for all systems. Up-arrow button. Press to increase the temperature setpoint or to scroll through settings options. Air direction button. Press to move louvers up & down in 6 degree increments. Louvers remain in place where stopped. Not available in all indoor unit models. Clock button. Press to set clock time. Timer ON button. Press to set the number of hours of delay before the indoor unit to begins operation. Timer OFF button. Press to set the number of hours of delay before the indoor unit stops operation. OK button. Press to confirm setting. Eco mode button. Not used. 4

Display Temp Transmitting display On/Off Operation mode AUTO COOL DRY HEAT FAN TEMP SET CLOCK SET HOUR FANS PEED ON OFF Time Lock Timer ON/OFF Economy operation Fan speed Temp. Displays the setpoint temperature. Adjust with up & down-arrow buttons. No display when unit is in Fan mode. Transmitting display. Icon blinks once when a signal is sent from the wireless remote controller. Running mode. Displays the selected mode. Economy operation. Not used. On/Off. Icon displays to indicate the last command sent by the Power button. Time. Displays the current time. Lock. Icon displays when Lock button is pressed. Timer ON/OFF. Icon lights up to indicate whether the timer is ON or OFF. Fan speed. Displays the current fan speed. 5

Operation Instructions Batteries 1. Grasp the controller cover by its sides and slide the cover down to remove. 2. Place batteries into battery compartment. 3. Replace cover onto controller. Auto mode System will automatically switch between heating and cooling depending on the temperature sensed at the controller. NOTE - Auto mode not available in all systems. Cool/Heat/Fan mode 1. Press the Mode button to select Cool, Heat, or Fan. 2. Adjust the temperature setpoint using up and down-arrow buttons for Cool or Heat modes. NOTE Temperature setpoint cannot be adjusted when in Fan mode. 3. Press the Fan speed button to select Auto, Low, Med, or High fan speed. NOTE - Auto fan speed not available for all systems. 4. Press the Power button to turn on indoor unit, the LED on the indoor unit displays. Dry mode 1. Press the Power button, an LED light on the indoor unit displays. 2. Press the Mode button to select Dry. 3. Adjust the temperature setpoint using up and down-arrow buttons. NOTE Fan speed is unavailable when in Dry mode. Timer operation Timer ON and Timer Off are used to turn on and turn off the indoor unit at selected intervals. Timer ON operation 1. Press the Timer ON button. TIMER displays. HOUR and ON lights up. 2. Press the Timer ON button again and use the up-arrow and down-arrow buttons to set the number of hours of delay before the indoor unit begins operation. The time will increase in half hour increments until 10 hours, then the increment becomes 1 hour. Timer OFF operation 1. Press the Timer OFF button. TIMER displays. HOUR and OFF lights up. 6

2. Press the Timer OFF button again and use the up-arrow and down-arrow buttons to set the number of hours of delay before the indoor unit stops operation. The time will increase in half hour increments until 10 hours, then the increment becomes 1 hour. Modify Timer ON/OFF settings 1. Press either the Timer ON button or the Timer OFF button to modify that setting. 2. Use the up-arrow and down-arrow buttons to change the timed operation intervals. 3. Set the timer to 0.0 to turn off timed operation. Set Clock Time 1. Press and hold the Clock button for 5 seconds, the Hour indicator will display. 2. Press the up-arrow and down-arrow buttons to select hour. 3. Press the Clock button again, the Minute indicator displays. 4. Press the up-arrow and down-arrow buttons to select minutes. 5. Press the OK button to confirm time. 7

Temperature Sensing Indoor Unit Default sensor. All indoor units have a temperature sensor that senses the zone temperature and controls operation of the indoor unit within the limits of the system. Remote Sensor Field installed accessory. Used to relocate temperature sensor from indoor unit to remote location. Temperature Display The controller is factory-set to display temperature in degrees Fahrenheit. To change the controller to display degrees Celsius: 1. Take off the back cover to gain access to the control board inside the controller. 2. Adjust SW1 dip switch on the board according to the table below. 1 2 SW1 ON OFF ON 1 2 Fahrenheit display OFF ON ON 1 2 Celsius display NOTE - Dip switch handle location is shown as a solid black box in the tables above. 8

NOTE - The indoor unit temperature unit display must be set at the same time as the controller. Indoor units default to display temperatures in F. To change the indoor unit temperature unit display, press and hold the Manual button on the unit receiver¹ for 5 to 15 seconds until the display changes to show the desired temperature unit. ¹ For VWM*024 and larger wallmounted indoor units only, the button is located on the unit s main control board and labeled SW3. Troubleshooting Digital Tube Display F0 E1 E2 E3 E4 EE E7 E0 Ed FE Content Wired remote controller and indoor unit communication failure Communication error between indoor and outdoor units Indoor ambient temperature sensor (T1) error Middle evaporator temperature sensor (T2) error Evaporator outlet temperature sensor (T2B) error Water level alarm error Indoor Unit EEPROM error Mode conflict error Outdoor units error IDU doesn t have address when it is first turned on 9

Technical Support 1-844-GET-VRF1 (1-844-438-8731) vrftechsupport@lennoxind.com www.lennoxvrf.com Download the app from the Apple App Store or the Google Play store. 10