Proportional Control Unit (PCU)

Similar documents
LED indicators for normal/fault operating conditions, setup mode, loss of analog signal, and solid-state motor control output.

VA-7700 Series. Electric Valve Actuators. Product Bulletin

Standard Options. Model 4100 Position Indicating Meter. Three Phase Motor Control. Positran Transmitter

GS400. Electronic Auto-Ranging DIN Panel Mounted Positioner

Powermite 599 MT Series SAS Electronic Valve Actuator 24 Vac or 24 Vdc, Proportional Control

Table of Contents 1. Overview Installation...6

ASI Systems ML5740A Series

ASI Systems ML5720A Series

ECON ELECTRIC ACTUATOR Fig. 7907, type ELA

Control Motor ECM3000

Electric Actuators and Control Systems. Established Leaders in Valve Actuation AD-8140 & AD Instruction Manual. Publication P971E Issue 08/09

ECM3000. Control Motor

Data Sheet A200 Series Electric Actuators

Installation, Operation and Maintenance Manual

SRQ24A. Technical data. Safety notes. Rotary actuator for ball valves Torque 16Nm Nominal voltage AC/DC 24V Control: Open-close Running time 9s

UDC 1000 and UDC 1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS

Industrial Electric Actuators AC and DC Voltages Nm/ inch lbs

AD-7830 Servo Amplifier

NKQB24-1, NKQX24-1 On/Off, Electronic Fail-Safe, Direct Coupled, 24V

Product Information SIMATIC S Digital Output Module SM 322; DO 16 UC24/48 V

Technote. Frese OPTIMA Compact actuators DN10-DN32. Application. Features thermic actuators. Features motoric actuators. Approval.

Electric Actuators and Control Systems. Established Leaders in Valve Actuation AD Instruction Manual. Publication P972E Issue 08/09

Flomatic Smart Card TM Model FDHC-100 (Digital High-Resolution Controller) Configuration and Operation Manual

K10 Intrinsically Safe Electro-Pneumatic Positioner Operating Manual

599 Series Zone Valve Actuator SF Series Electronic Valve Actuator, 2-position Control

I ntroduction. RA Fast Running Electric Actuator. Features and Benefits

J3C-H20DPS 25Nm Smart Electric Actuator Type: J3C Model: H20DPS

Electromotive actuators for combi valves

INSTRUCTIONS FOR MODEL 1000 DIGITAL PROCESS INDICATOR AND ALARM

Motorised actuator 0-10V EAC

MODEL: M5DY SEN TRONIC AG CURRENT LOOP SUPPLY. [2] POWER INPUT AC Power M: V AC (Operational voltage range V, Hz)

PC2004 PRESSURE CONTROLLER

Linear Actuators (235N)

VA Electric Terminal Unit Actuator. Benefits. Technical Specifications. Double colour LED. Low and line voltage.

BMX DDM Mixed Relay Input/Output module

INSTALLATION AND MAINTENANCE INSTRUCTIONS For Chemline A- & Q-Series Actuator with Digital (AC) Positioner

USER MANUAL. Valve System Test Centre 1/26

PIECAL 322 Automated Thermocouple Calibrator Operating Instructions. Product Description. Practical Instrument Electronics

AV24-MFT AV24-MFT2 AV24-MFT2-C105. Power consumption In operation For wire sizing N 1700 N Control Control signal Y Operating range

SBB4I2O230 ENG. Fire damper I/O Module. Benefits. Description

TPE 1464 Series Pressure Transducer

AME 658 SU/ SD with safety function Motorized actuators for AB-QM valves

Available with actuator function: POWER OPEN - POWER CLOSE FAILSAFE MODULATING FAILSAFE MODULATING. Overview

Products no longer available

P216. Condenser fan speed controller. Product bulletin. Features

NKQB24-1, NKQX24-1 On/Off, Fail-Safe, Operation, Direct Coupled, 24V

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Can eliminate static charge over an extensive range

NT10 Series RS485 Modbus RTU Networking LCD Fan Coil Thermostat

Safety Monitoring Relays

E2Q4 Square Proximity Sensor

Measure & Control Temperature & CO2 levels with analog & digital I/O

Rotary version, three-position control

Microprocessor based Temperature / CO2 Controller c/w 365 Day Time Switch & Modbus Communication.

Products no longer available

SALES NUMBER NUMBER OF BEAMS PROTECTIVE HEIGHT

Electrical actuator AME 855

NEUROLOGIC RESEARCH CORPORATION MODEL 2500

OPERATOR S MANUAL MODEL LS110 MINI-PBX SIMULATOR

MAN-652-OM1. 3 Oct 07 Revision G.R. G.A. 2 Jun 06 Revision A.G. G.A. 1 Feb 06 Revision A.G. G.A. Rev. Date DESCRIPTION Prepared Approved

Multi-Port Actuator O&M MANUAL

The PM1000 series is a universal 4 digit LED plug-on display for transmitters with 4-20mA 2 wire output and fitted with DIN43650 connector.

DPST-NO None 2 channels Auto-reset Inverse (+/-) 24 VAC/VDC 4 G9SB-2002-A 1 channel or 2

Overview of types. Technical data

TS InteliSwitch Digital Time Switch 24VDC/VAC

/8 DIN Motorized Valve Controller

OPERATING INSTRUCTIONS 7 SERIES STATIC GENERATORS

CDD4 Duct Carbon Dioxide Transmitter

Series F75 Fail-Safe Module Installation, Operation and Maintenance Instructions

Modulating controlled actuators AME 10, AME 20, AME 30 AME 13, AME 23, AME 33 - with DIN EN certified safety function (spring down)

Input Frequency: 650 range 50/60Hz 675 range Hz Input Ranges in Amps: Measurement Maximum Inrush

KOBOLD Compact Electronics

SIAC-PS 3G SIGNAL ISOLATOR WITH POWER SUPPLY (PART NO. 8890) INSTALLATION INSTRUCTIONS

599 Series Zone Valve Actuator SF Series Electronic Valve Actuator, 2-position Control

Installation, Maintenance and Operating Instructions

Controller module. Brief description. Features. Block structure. Data Sheet Page 1/7

Controller module. Brief description. Features. Block structure. Page 1/7. Data Sheet

R7426D UNIVERSAL INPUT CONTROLLER. MicroniK 200 FEATURES GENERAL. Order Numbers SPECIFICATION DATA

Basic Temperature and Limit Controllers. Provide Economical Solution for a Wide Range of Applications SPECIFICATION SHEET

CDD Carbon Dioxide Transmitter

EIM CONTROLS TEC2000. Installation & Operation Manual. E2K Release 1

Safety Relay Unit (I/O Unit Type)

DUTY, UNIVERSAL ON/OFF & MODULATING ELECTRIC ACTUATORS

LM24A-MOD. Cable 1 m, 6 x 0.75 mm 2 RJ12 socket

RCx-xxxAx Installation. Contents. Mounting: Holes for a mounting bracket. Holes are threaded for ¼-20 and are approximately.275 deep.

KOBOLD PDA Series Digital Pressure Transmitter

KOBOLD TDA Series Digital Temperature Transmitter

Differential Liquid/Gas Pressure Transmitter

NT PRESSURE TRANSDUCER MODELS 4100, 4210, 4130, 4230

PEAKTRONICS DHC-100 FEATURES. Digital High-Resolution Controller

MiG2 CONTROLLERS. 2 & 4 Stage General Purpose Controllers, with Air-conditioning Facilities

E2A. Ordering Information. Cylindrical Proximity Sensor. Safe Mounting with Greater Sensing Distance. E2A Cylindrical Proximity Sensor 1

Service Instructions. Conductor 420

SX90 Process Controller

Operating instructions. Switching amplifier DN0210 DN / / 2015

LCx-xxxAx-8.08 Linear. Installation. Contents. Mounting: Short Instruction LCx-xxxAx Connecting Power and Signal

SM-1015 Digital Actuator

Monitoring Relays can be used to monitor 3-phase power supplies with 3 or 4 wires simply by changing DIP switch settings.

2 Table of Contents 1. TABLE OF CONTENTS. 1. Table of Contents Introduction Wiring Diagram Terminals Review...

Electric Actuator Smart Controller

Transcription:

Proportional Control Unit (PCU) HQ-006 to HQ-300 Installation & Maintenance Manual The EIM HQ Series PCU is a Digital positioner with a Microprocessor and 12-bit A/D converter. By moving the actuator to mid position and pressing the auto scan button, the positioner automatically cycles the unit for calibration. The PCU module controls the actuator by comparing two inputs (the desired position from process controller or computer and actual valve position feedback). If the two are within bandwidth, the actuator will not move. When the set point moves outside the bandwidth, the actuator moves in the required direction to make the control signal and valve position feedback inputs balance. HQ Series PCU I&M Manual HQ-401-0606 1

Table of Contents: PCU Layout 1.0 PCU Function and setup 2.0 Select Input signal 2.1 Select Output signal 2.2 Select fail position 2.3 Delay time / Dead band 2.4 Local operation 2.5 Auto Calibration 2.6 Split Range 2.7 Reverse Acting 3.0 Standard Specifications 4.0 EIM Office Locations 5.0 User Safety Warning: Use caution when working in, with, or around valves and actuators. High pressures, forces, voltages and flammable media can be present Warning: Failure to follow instructions for proper electrical wiring, storage, set-up and maintenance may cause serious injury, damage equipment, or void warranty HQ Series PCU I&M Manual HQ-401-0606 2

1.0 PCU Layout Figure 1 HQ Series PCU I&M Manual HQ-401-0606 3

2.0 PCU Function and setup (refer to Figure 1 for location of switches) 2.1 Select Input Signal User can select input signal type by adjusting DIP switches as follows: 4-20mA DC 2-10VDC 0-5VDC 0-10VDC 1-5VDC If not specified, the factory default is 4-20mA. 2.2 Select Output Signal User can select output signal type by adjusting DIP switches as follows: 4-20mA DC 0-10 VDC 0-5 VDC 0-5 VDC 1-5 VDC If not specified, the factory default is 4-20mA 2.3 Setting Fail Position User can select the fail position of the actuator (when control signal is lost) by adjusting the DIP switches as follows: Fail Close Fail Open Fail in Last Position 2.4 Delay Time / Deadband The adjustable delay feature prevents continuous operation of the actuator motor caused by abnormal changes in the input signal. Clockwise rotation of the Delay Dial will increase the delay time. (Range 0 to 7.5 seconds) Seconds 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5 7.0 7.5 Dial 0 1 2 3 4 5 6 7 8 9 A B C D E F HQ Series PCU I&M Manual HQ-401-0606 4

The deadband adjusts the limits of deviation of the valve s desired position to its actual position. Clockwise rotation of the Band dial will increase the deadband. (Range 0 to 7.5%) % 0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5 7.0 7.5 Dial 0 1 2 3 4 5 6 7 8 9 A B C D E F If the deadband is set too low, it may cause actuator hunting. 2.5 Local Operation This feature allows for temporary local operation by use of the Zero/Close and Span/Open (Figure 1) buttons on the PCU board to open and close the valve. To access this feature, simultaneously push the Zero and Span buttons, hold for two seconds, and release. The yellow Fault LED will be lit to indicate Local operation mode. If no operation occurs within 15 seconds, the PCU will default to setpoint control 2.6 Auto Calibration This feature allows for automatic calibration of the PCU card to the preset limits, without the need for a signal generator. To access this feature, press the A-Scan button one time. The white Auto Scan LED will flash. The unit will then automatically stroke to the close limit, pause, then stroke to the open limit and stop. The PCU will now be calibrated. Unit is calibrated at the factory, and settings are saved in non-volatile memory. No recalibration required unless the limits are changed. 2.7 Split Range This feature allows a range of set points for full open and full close positions. Close: 3 to 8mA DC Open: 16 to 21mA DC For example: If the customer would like to assign 5mA to the fully closed position, supply a 5mA signal and then allow the actuator to move to the corresponding position. Move switch 4 (CH1) to the on position, and press the Zero button one time. The actuator acknowledges that position as fully closed and transmits 4mA. Push the Span button to set the fully open position. Once the setting is complete, move switch 4 down to the off position. HQ Series PCU I&M Manual HQ-401-0606 5

3.0 Reverse Acting: Standard operation is clockwise rotation of the actuator to close. When reverse action, or counterclockwise rotation to close is required move switch 5(CH2) to the on position (up). Move actuator to mid position and push A-scan button. Supply signal and check rotation. Switch 5 on (up) = 20mA Full Close 4mA Full Open Switch 5 off(down) = 4mA Full Close 20mA Full Close 4.0 Standard Specifications Power: 85-280 VAC ±10% 50/60Hz 4VA Max Input signal: 4-20mA DC, 2~10 VDC, 0~5 VDC, 0~10 VDC, 1~5 VDC Input resistance: 250 Ohm Output signal: 4-20mA DC, 2~10 VDC, 0~5 VDC, 0~10 VDC, 1~5 VDC Output Load resistance: 750 Ohm Max. Control output : Relay contact 250 VAC 10A Max (Inductive load) Number of output contacts: 2 ea (Open and Close contact) Delay time adjustment: 0 ~ 7.5 sec (1 Step = 0.5 seconds, 15 steps total) Dead band adjustment: 0 ~ 7.5% (1 Step = 0.5%, 15 steps total) Ambient temperature: -10 o C ~ +70 o C Ambient humidity: 90% RH Max (Non-condensating) Dielectric strength: 1500V AC 1Min (Input to output, Power to Ground) Insulation resistance: Min. 500VDC 30 Mohm On Board LED Indication LED Blue on Blue Blinking Green on Red on Yellow on Yellow Blinking SIGNAL Power on Auto Calibrating Close Open Card Manual mode Fault HQ Series PCU I&M Manual HQ-401-0606 6

5.0 EIM Office Locations Head Office and Factory EIM Controls, Inc. 13840 Pike Road Missouri City, Texas 77489 USA (800) 679-1561 toll-free, US Only (281) 499-1561 phone (281) 499-8445 fax sales.usa@eim-co.com Eastern Hemisphere Sales EIM Controls UK Ltd. 6-7 Galaxy House New Greenham Park, Newbury, Berkshire RG19 6HW, England +44 (0) 1635-817-315 phone +44 (0) 1635-817-460 fax sales.international@eim-co.com EIM Northeastern Regional Office sales.northeast@eim-co.com EIM Controls China sales.china@eim-co.com EIM Southwestern Regional Office sales.southwest@eim-co.com EIM Controls Japan sales.japan@eim-co.com EIM Southeastern Regional Office sales.southeast@eim-co.com EIM Controls Italy sales.italy@eim-co.com EIM Midwestern Regional Office sales.midwest@eim-co.com EIM Controls Benelux sales.benelux@eim-co.com EIM Western Regional Office sales.western@eim-co.com HQ Series PCU I&M Manual HQ-401-0606 7