Field Term Plug Installation Guidelines

Similar documents
New Standardized Cabling Options for NBASE-T Devices

Simplifying Direct Connect Deployment Using Field Term Plugs in Connect Cabling Systems

Saving Critical Space. Cable Management Solutions

or go home GO SMALL SEPTEMBER 2015 FOR PROFESSIONALS MANAGING THE CABLE AND WIRELESS SYSTEMS THAT ENABLE CRITICAL COMMUNICATIONS STANDARDS

Ronald Tellas, Technology and Applications Manager, Enterprise Networking

Siemon PON Fiber Cabling Solutions

Panduit PreConfigured Industrial Distribution Frame (IDF) Installation Instructions Part Numbers ZDF48-RA and ZDF48-EA ZDF48-6RA and ZDF48-6EA

The University of Texas at Austin July 30, 2014 SECTION COMMUNICATIONS TERMINATION BLOCKS AND PATCH PANELS

Power Over Ethernet with Panduit Copper Cabling. How To Create More Meaningful Connections With The Highest Performing Infrastructure

The Impact of Internet of Things (IoT) on Cable Certification

How You Can Optimize Passive Optical LAN Through Structured Cabling

TIA/EIA 568A Sub-system HORIZONTAL CABLING

VF-45 TM (SG) Ferrule-Less Interconnect Proposal

Quick Disconnect vs. Hard-Wiring: Selecting A Connectivity System For Your Industrial Application

v2.5 was updated May 10, v2.6 is an updated copy from March 1, 2017.

Power Over Ethernet with Panduit Copper Cabling. How To Create More Meaningful Connections With The Highest Performing Infrastructure

Managing Density Managing Density in the Data Center: A Long-term Approach for the Future

Bree Murphy, RCDD National Training, Applications Engineer sh. Professional Wi Fi Installation Solutions

With its tamper-resistant design, the

4.5 Components for TV/SAT, telephone installations and Category DATATEL Series - TEL DATATEL Series - CAT5 DATATEL Series - TV/SAT

LC Connector. A High Density Fiber Optic Network Solution. Paul Kolesar Lucent Technologies, Bell Laboratories

AP65 Access Point. The Aruba AP65 Access Point is a compact Tri-Band Wireless Unit supporting the a, b and g WiFi standards.

Home Networks. Principles, Applications and Desirability

PHYSICAL INFRASTRUCTURE SYSTEMS

VOLITION INTERCONNECT VF-45 STYLE

Bree Murphy, RCDD National Training, Applications Engineer Professional Wi Fi Installation Solutions

CableSmart Series Nonmetallic Raceway

60-Watt Ultra Power over Ethernet Injector

Cabling to support ac and beyond. Nate Herring Sr. Product Manager Hubbell Premise Wiring

The Impact of Internet of Things on Cable Certification

PANZONE ZONE CABLING SYSTEMS

OMEGA MODULAR PATCH PANEL EMPTY ENCLOSURE

4-Port 10/100Mbps 802.3at / af PoE + 1-Port 10/100Mbps Desktop Switch

4-Port 10/100Mbps 802.3at/af PoE + 1-Port 10/100Mbps Desktop Switch

19" TiRAX cabinet system. from page 3. 19" NETcell cabinet system from page 31. Open 19" racks from page 43

RCC45 ➁ Overview / /

Tarleton State University. Specifications

Classroom WiFi Network Infrastructure Plan

Uniprise Structured Cabling Solutions Guide

POWER OVER ETHERNET SYSTEMS

Network Construction Guide Specification Telecommunications Infrastructure Standards V 2.6

Single-Port 10/100/1000Mbps 60W Ultra PoE Injector

Information & Communications Technology Network Infrastructure Group. Network Infrastructure Standards June 2008

The SYSTIMAX GigaSPEED X10D solution. The infrastructure modern enterprises and data centers depend on

4-Port 10/100/1000T 802.3at PoE + 2-Port 10/100/1000T Desktop Switch

8-Port 10/100Mbps 802.3at PoE + 1-Port 10/100/1000Mbps Desktop Switch

The 5500 Series from The Wiremold Company

Data sheet C6 A modul 1 port 180 M AP pure white

This attractive raceway conceals and

PoE Lighting Benefits and Design Considerations. Creating more meaningful connections in the digital building

3M Telecommunications Solutions for Networks. Volition Network Solutions Product Solution Guide. for Enterprise Networks.

Volition. Multimode VF-45 Socket and Patch Cords. 3Innovation

Voice Integration Overview

Universal connectivity grid design guide

Computer Network Design Guide Existing Systems 1 / 6

InstaPATCH Cu Cabling Solutions for Data Centers

Fiber or Copper Which Costs More? Daniel Harman Aug 2006

Volition. VF-45 Singlemode Socket and Patch Cords. 3Innovation IT'S AS EASY AS PLUGGING IN AN RJ-45.

Installing the Power Board in the. 16-Port Cisco Ethernet Switch Network Module CHAPTER

This attractive raceway conceals and

Jamey Calloway, RCDD Product Management Specialist Optical Cable Corporation

Total Amount Carried Forward To Bill summary Page

The advantages of the 6-connector channel

FTTE Revisited for New Technologies

E. Numbering and Labeling Pathway components. In general, pathway components are not labeled.

4-Port 10/100/1000T 802.3at PoE + 2-Port 10/100/1000T Desktop Switch

Volition. Multimode VF-45 Socket and Patch Cords. 3Innovation

3M Category 6 Copper Structured Cabling System

Single-Port 10/100/1000Mbps 802.3bt PoE++ Injector (95 Watts, internal PWR)

AMP NETCONNECT EtherSeal System Bringing Ethernet and Structured Cabling to Non-Office Environments.

Wireless Enclosures from Wiremold/Legrand

PHYSICAL INFRASTRUCTURE SYSTEMS

The Riser as a Contract Document. Peter Sharp, RCDD

Fiber Optic System. Fiber Optic System. Fiber Optic Rack Mount Solutions

Termination for 568A and 568B pin configurations.

The 5400 Series Raceway from The Wiremold

Peter Sharp RCDD IBI Group

Distribution Devices - Outlets, Jacks, & Plates

Chapter 4: Network Access. Introduction to Networks v5.1

The SYSTIMAX GigaSPEED X10D solution. The infrastructure modern enterprises and data centers depend on

LACCD IT Design Standards

Network+ Guide to Networks 7 th Edition

Data Cabling / Low Voltage Technology Specifications

PC100 - Concept. Advantages in comparison

take your data centre to the next level

Product Manual MNX10043 REV A MODEL DSB. Dual Sensor Modular Switch box

MASTERLINE Ultimate Hybrid High Voltage 4/12 (MLUH HV 4/12) blunt cut at BTS side

Data Products & Accessories

CELL SITE INFRASTRUCTURE SOLUTIONS. Creative Solutions for the Mobile Evolution

SYSTIMAX 360 ipatch Network Manager Module Faceplate Instructions

nflexon The New IT Ecosystem

The 400, 800, and 2300 Series, from

Hypercable injecteur HPOE - Industrial IEEE 802.3at Gigabit PoE Injector. User Manual. v.1.0 Jun Mail :

3M ID 3000 System. ID 3128 block. Disconnection module. ID 3100 block Wire guide housing

A COMPARISON OF PRE-POLISHED CONNECTORS VS. FUSION-SPLICED PIGTAILS AS FIELD TERMINABLE SOLUTIONS

E-DAT C6A. The compact connection system of course with Cat.6A

This attractive raceway conceals and

The six major components of a structured wiring system are:

IEEE P802.3cg 10 Mb/s Single Twisted Pair Ethernet Task Force (10SPE)

Rack Selection Guide for NetShelter SX

Transcription:

Field Term Plug Installation Guidelines Today s enterprise networks support a growing number of deployed devices which raise several questions for those who build and maintain the network infrastructure for those environments. This guide addresses these questions by reviewing common cabling methods and components used to connect devices to the network, identifying key factors for choosing a cabling method, showing cabling examples using the field terminable plug and other connection methods with several common devices. Cabling Methods for Network Devices 1 Which Cabling Method is Better? 2 Selecting a Cabling Method 3 Device Cabling Examples 8 Field Term Plug Part Number Reference 10 2018 Panduit Corp. ALL RIGHTS RESERVED. PN622

Telecom Room Telecom Room 1 Cabling Methods for Network Devices Like traditional network equipment such as computers or printers, most modern network devices include one or more RJ45 ports for being connected to the network. The two most common methods used to provide plugended network cabling to network devices are described below. Direct Connect Method The newest method is the direct connect approach where a field terminable plug is attached directly to the end of the horizontal cabling which is then plugged into the device, connecting it to the network. PoE Device Horizontal Cable RJ45 Plug Patch Cord Method The second method is the traditional structured cabling approach referred to here as simply the patch cord method in which the horizontal cable terminates to a modular jack and a patch cord is used to connect the device to the network. PoE Device Horizontal Cable Patch Cord Modular Jack Jack Outlet Page 1 of 10

2 Which Cabling Method is Better? Given their differences, each method has inherent advantages in different areas as listed below. Direct Connect Method Patch Cord Method Provides cost savings, faster installation, and increased reliability. Lower install cost and faster installation with fewer components Plug terminated directly to horizontal cable avoids need for junction box Increased reliability due to fewer points of failure Included upcoming TIA-568 revision draft Familiar method that provides modularity and physical flexibility. Familiar approach doesn t require training Modular plugs on patch cords are generally more compact than field terminable plugs, allowing better fit in confined ports Flexible cable routing options Easier device movement Included in TIA-568 As you can see, neither cabling method is better in every case. In addition, the features of the cable and connector components used in the cabling system can have a big impact on how well each method works in an application. The compelling cost and time benefits of the direct connect method make it highly desired by installers and end customers, while the adaptability and accessibility benefits of the patch cord method make it useful in many applications. Therefore, it is easy to see a good rule of thumb is: Use Direct Connect for lower cost and faster installation. Use Patch Cord for tight spaces and flexibility. Page 2 of 10

3 Selecting a Cabling Method The question then is when should you use each method? To answer this question, Panduit has identified three key factors to selecting the best cabling method for a specific application and/or device. Port and Cabling Layout of the Device Device Mounting Environment Cabling and Connector Solutions Used 3.1 Port and Cabling Layout of the Device Two features of the device the port layout and the cable routing path have perhaps the largest influence on the cabling method selected for a device. Both areas are discussed in detail below. Port Layout of the Device This refers to the physical location, orientation, and space surrounding the RJ45 port on the device. To determine the port layout of the device, ask the following questions: Where is the port located on the device and how is it oriented? Is there surrounding geometry on the device, such as walls or obstructions, that limit access to the plug latch or the port itself? What types of plug will physically fit in the space available? Is there room for the cable as it exits the plug? Once the plug is inserted, how is the latch actuated to remove the plug? Page 3 of 10

Recommendations The size and configuration of space around the device port can affect the type of plug which will work best. Below are cabling method recommendations based on the space available around the port. 1 If space is relatively open: Either method may be used because space is not an issue. 2 If space is somewhat limited: Either method may be used, but the direct connect method will require an angled plug because less space is needed for the cable exit. 3 If space is very limited or access to the plug latch is constrained: The patch cord method is preferred when space is limited because the modular plugs, used on patch cords, can be smaller than field-terminable plugs allowing for easier access to the plug latch for removal. Examples: The devices above provide the widest range of cabling options because they have minimal space restrictions around the port and easy access to the plug latch for removal. Examples: These devices show features which (1) position the port in a way which makes access to the plug latch difficult, (2) limit room for the cable to immediately exit the plug, and/or (3) limit space for the plug itself. Such cases may require an angled entry direct connect plug, a patch cord, or in the tightest spaces, a 28 AWG patch cord. Page 4 of 10

Cable Routing Path of the Device This refers to the physical space and required path the cable must follow at the mounted device to reach the RJ45 port. To determine the cable routing path, ask the following questions: Is the cable path open or tightly constrained? Is it straight or are multiple bends required? During normal device operation or maintenance, is movement of the cable required such as a security camera which hinges to open for maintenance? Along the cable routing path to the device, is there space and structure available for fitting a modular jack interface? Recommendations The cable routing path can influence which cabling method is best suited for connecting the device due to the different types of cable used in each method. Below are cabling method recommendations based on cable routing path. 1 If the cable routing path is open: Either method may be used because routing is not an issue. 2 If the cable routing path is tightly constrained or requires movement: The patch cord method is more suitable since patch cord cabling is generally smaller in diameter and more flexible than the horizontal cabling. 3 If the cable routing path is challenging: 28 AWG patch cords may be required since they use half the size of traditional patch cords and are much more flexible to accommodate tight bends in the routing path. Examples: The devices above have open or unconstrained routing paths, providing the most cabling options. The direct connect method can easily be used because there are no bend radius concerns. Examples: The devices above have constrained cable routing paths that require tight bends. In these cases, a patch cord may be preferred because of its smaller size and flexibility. In the most extreme cases, 28 AWG patch cords may be required. Page 5 of 10

Pand 3.2 Device Mounting Environment Several aspects of the mounting of the device, such as the physical location, means of attachment, mounting environment, and likelihood of the device being moved in the future. To determine the device mounting environment, ask the following questions: Is the mounting location easy or difficult to access? Is the space around the mounted device generally open or are there nearby obstructions that complicate cable routing or access to the device port? Is the device location expected to be relocated in the future? Recommendations Due to basic differences between the cabling methods in the cable options available and the level of system modularity, the device mounting location can have a large impact on the cabling method and components used. Below are cabling method recommendations based on the device mounting environment. 1 If the mounting environment limits cable routing options, due to obstructions: Either angled entry direct connect plugs or patch cords. 2 If the mounting environment is hard to access: The direct connect method is recommended because of the increased reliability. 3 If the device is likely to be relocated: The patch cord cabling method is recommended because of its modularity, which requires the least effort to run to the new location. Example: Drop ceiling locations can usually accommodate either cabling method, as there is normally open space to work with and the ceiling conceals the cabling. Example: If a jack outlet can be located close by, the patch cord method may be better for wall mounted devices because either a faceplate or surface mount box provides a housing for the modular jack that is visually clean. Example: The direct connect method is recommended for hard to access environments, such as roof-mounted security cameras, due to its increased reliability and the ability of the cable to feed directly through the conduit to the device without a need for an intermediate jack connection. Page 6 of 10

3.3 Cabling and Connector Solutions Used Finally, the features of the cabling and connector solutions themselves can impact which cabling method can be used. While the basic components used in each method are similar such as horizontal cabling, modular jacks, field terminable plugs, or patch cords differences in the features of the components can affect the feasibility of each cabling method for an application. For the following basic cabling components, here are some important questions to consider: Horizontal Cabling How large in diameter is the cable, and how does it compare in size to the smallest diameter cables available of that type and performance level? Modular Jacks Are options available for angled cable routing paths into the jack? Does the port opening have a protective shutter if the port opening will be exposed to dust and debris? And are those options available in the performance level and type (UTP or shielded) needed? Jack Housings and Outlets Are multiple configurations, such as port count, color, or method of attachment, available to accommodate varying application needs? Field Terminable Plugs Will the plug be terminated in the field and is it quick and easy to do? Is the plug itself compact in size? Are angled cable routing options available? Can the plug be re-terminated if a change must be made? Patch Cords Are small diameter (28 AWG) cord options available in the type and performance level needed? Are reduced size plugs available for fitting in tight spaces? Recommendations Component features can impact whether a cabling system will work in the desired method. It is recommended that components be selected based on whether they have the needed features such as smaller cabling size, multiple routing directions into a connector, multiple outlet configurations or multiple cord size options. Page 7 of 10

Cisco 3800 Series Cisco 3700 Series Cisco 3600 Series Cisco 1700 Series 4 Device Cabling Examples The growing variety of network devices and mounting environments leads inevitably to the question of What cabling method can I use on this device? While it is impossible to answer that question given the endless range of devices and mounting environments, the following examples illustrate common device configurations for wireless access points and cameras. Wireless Access Point Examples - Direct Connect (Angled) or Patch Cord Wireless Access Point Examples - Direct Connect or Patch Cord Page 8 of 10

Samsung Snd-L6012 Series Cisco 2421 Series Camera Examples Direct Connect or Patch Cord AXIS 233D Series Vaddio ConferenceSHOT Hikvision DS-2CD112 Series Camera Examples Patch Cord Page 9 of 10

5 Field Term Plug Part Number Reference Below are Panduit part numbers for the Field Term Plug. Straight Field Term Plug FP6X88MTG (single pack) FP6X88MTG-X (10-piece bulk pack) Angled Field Term Plug FPUD6X88MTG (single pack) FPUD6X88MTG-X (10-pc bulk pack) Termination Tools EGPT (works with both Angled and Straight Field Term Plug versions) EGJT-1 (works with Straight Field Term Plug version and straight TG-style Mini-com modular jacks) Page 10 of 10 2018 Panduit Corp. ALL RIGHTS RESERVED. PN622