ATV12HU22M3 variable speed drive ATV12-2.2kW - 3hp V - 3ph - with heat sink

Similar documents
ATV12P075M3 variable speed drive ATV kW - 1hp V - 3ph - on base plate

ATV12H075M3 variable speed drive ATV kW - 1hp V - 3ph - with heat sink

ATV12P037F1 variable speed drive ATV kW hp V - 1ph - on base plate

ATV12H018M2 variable speed drive ATV kW hp V - 1ph

ATV310H075N4E variable speed drive ATV kw - 1 hp V - 3 phase

ATV310HU30N4E variable speed drive ATV310-3 kw - 4 hp V - 3 phase

ATV32HU75N4 variable speed drive ATV kw V - 3 phase - with heat sink

ATV320U04N4C variable speed drive ATV kW V - 3 phase - compact

ATV32H075M2 variable speed drive ATV32-0,75 kw V - 1 phase - with heat sink

ATV320U07M2C variable speed drive ATV kW V - 1 phase - compact

ATV32HU11M2437 variable speed drive ATV32-1.1kW 200V - 1P - Bluetooth built-in - w heat sink

ATV61HC31Y variable speed drive ATV61-310kW - 690V - without EMC filter

ATV32HD11N4 variable speed drive ATV32-11 kw V - 3 phase - with heat sink

ATV32HD11N4 variable speed drive ATV32-11 kw V - 3 phase - with heat sink

ATV32H018M2 variable speed drive ATV32-0,18 kw V - 1 phase - with heat sink

ATV32HU30N4 variable speed drive ATV32-3 kw V - 3 phase - with heat sink

ATV32HU30N4 variable speed drive ATV32-3 kw V - 3 phase - with heat sink

ATV32HU30N4 variable speed drive ATV32-3 kw V - 3 phase

ATV32H055N4 variable speed drive ATV kw V - 3 phase - with heat sink

ATV320U06N4C variable speed drive ATV kW V - 3 phase - compact

ATV212WU40N4 variable speed drive ATV212-4kW - 5hp - 480V - 3ph - EMC class C2 - IP55

ATV61HC11N4 SPEED DRIVE 150 HP 460 V ATV61

ATV32HU40N4 variable speed drive ATV32-4 kw V - 3 phase - with heat sink

ATV61HU55M3 ATV61 5,5 kw 7,5HP 240V single phase EMC IP20

ATV930U30M3 variable speed drive - ATV930-3kW - 200/240Vwith braking unit - IP21

ATV61QC31N4 variable speed drive ATV61Q - 315kW / 500HP V - IP20

ATV71QC16N4 variable speed drive ATV71Q - 160kW / 250HP V - IP20

ATV320D11N4B variable speed drive ATV320-11kW V - 3 phase - book

ATV320D15N4B variable speed drive ATV320-15kW V - 3 phase - book

ATV320D15N4B variable speed drive ATV320-15kW V - 3 phase - book

ATV212HD18N4 variable speed drive ATV kW - 25hp - 480V - 3ph - EMC - IP21

ATV320U30N4B variable speed drive ATV320-3kW V - 3 phase - book

ATV212HD11N4 variable speed drive ATV212-11kW - 15hp - 480V - 3ph - EMC - IP21

ATV212WD30N4 variable speed drive ATV212-30kW - 40hp - 480V - 3ph - EMC class C2 - IP55

ATV930D22M3 variable speed drive - ATV930-22kW - 200/240V- with braking unit - IP21

ATV212WU55N4 variable speed drive ATV kW - 7.5hp - 480V - 3ph - EMC class C2 - IP55

ATV340D75N4E variable speed drive - 75kW- 400V - 3 phases - ATV340 Ethernet

ATV650U30N4E variable speed drive ATV650-3kW V - IP55 - disconnect switch

ATV630U15N4 variable speed drive ATV kW/2HP V - IP21/UL type 1

ATV212HU55N4 variable speed drive ATV kW - 7.5hp - 480V - 3ph - EMC - IP21

ATV61HC22N4 Altivar 61 drive 350hp 400/480 3ph

ATV340D18N4E variable speed drive - 18kW- 400V - 3 phases - ATV340 Ethernet

ATS22D75S6 soft starter-ats22-control 220V-power 230V(18.5kW)/ V(37kW)/500V(45kW)

ATS22D62Q soft starter-ats22-control 220V-power 230V(15kW)/ V(30kW)

ATS22C21S6U softstarter-ats22-control110vpower208v(60hp)/230v(75hp)/460v(150hp)/575v(200hp)

ATV212HD15N4 variable speed drive ATV212-15kW - 20hp - 480V - 3ph - EMC - IP21

ATV71EXA2C71N4 enclosed variable speed drive ATV71 Plus kw - 400V - IP23

ATS22D88S6U. ATS22D88S6U soft starter-ats22-control110v-power 208V(25hp)/230V(30hp)/460V(60hp)/575V(75hp) Product data sheet Characteristics.

ATS01N206RT soft starter for asynchronous motor - ATS01-6 A V

ATS22D17Q soft starter-ats22-control 220V-power 230V(4kW)/ V(7.5kW)

ATSU01N209LT soft starter for asynchronous motor - ATSU01-9 A V KW

ATV61HC31N4 variable speed drive ATV61-315kW 500HP - 500V - EMC filter - IP20

ATS01N232RT soft starter for asynchronous motor - ATS01-32 A V

ATV212HU55N4 variable speed drive ATV kW - 7.5hp - 480V - 3ph - EMC - IP21

ATV630D15N4 variable speed drive ATV630-15kW/20HP V - IP21/UL type 1

ATV650D22N4 variable speed drive ATV650-22kW/30HP V - IP55

ATV320U04N4C variable speed drive ATV kW V - 3 phase - compact

ATV212HD11M3X variable speed drive ATV212-11kW - 15hp - 240V - 3ph -wo EMC - IP21

ATV630D11N4 variable speed drive ATV630-11kW/15HP V - IP21/UL type 1

ATV930U07M3 variable speed drive - ATV930-0,75kW - 200/240V- with braking unit - IP21

ATV61HD11Y variable speed drive ATV61-11kW / 690V - 10HP / 575V - IP20

ATV212HD15N4 variable speed drive ATV212-15kW - 20hp - 480V - 3ph - EMC - IP21

ATS22C11S6U soft starter-ats22-control110vpower208v(30hp)/230v(40hp)/460v(75hp)/575v(100h

ATV212HD30N4 variable speed drive ATV212-30kW - 40hp - 480V - 3ph - EMC - IP21

ATV212HU75N4 variable speed drive ATV kW - 10hp - 480V - 3ph - EMC - IP21

ATV212HD75N4. Main. Range of product Altivar 212. Device short name. Motor power hp 160 A 460 V khz with derating factor

ATV630D90N4 variable speed drive ATV630-90kW/125HP V - IP21/UL type 1

ATS22D17Q soft starter-ats22-control 220V-power 230V (4kW)/ V(7.5kW)

ATS22C11S6U soft starter-ats22-control110vpower208v(30hp)/230v(40hp)/460v(75hp)/575v(100hp)

ATS22D75Q soft starter-ats22-control 220V-power 230V(18.5kW)/ V(37kW)

ATS22D75S6U. Main. Range of product Altistart 22. Component name. Factory setting current. Utilisation category. IP degree of protection

TM5C12D6T6L compact I/O expansion block TM5-24 I/0-12 DI - 6 DO transistor - 4 AI - 2 AO

ATV320D15M3C variable speed drive ATV320-15kW - 200V - 3phase - compact

LXM28AU07M3X motion servo drive - Lexium 28 - single and three phase V W

ATV212HD30N4 variable speed drive ATV212-30kW - 40hp - 480V - 3ph - EMC - IP21

ATV212HD22N4 variable speed drive ATV212-22kW - 30hp - 480V - 3ph - EMC - IP21

ATS01N103FT soft starter for asynchronous motor - ATS01-3 A V KW

ATS22C41Q soft starter-ats22-control 220V-power 230V(110kW)/ V(220kW)

ATS22C17Q. Main. Range of product Altistart 22. Component name. Factory setting current. Utilisation category. IP degree of protection

ATV630U15N4 variable speed drive ATV kW/2HP V - IP21/UL type 1

ATV212HU15N4. Main. Range of product Altivar 212. Device short name 3.7 A 460 V khz adjustable

ATV660C16Q4X1 Compact Drive System ATV /132kW V - IP23

ATS22D47S6U. Main. Range of product Altistart 22. Component name. Factory setting current. Utilisation category. IP degree of protection

ATV930D45N4 variable speed drive - ATV930-45kW - 400/480V - with braking unit - IP21

ATV930U55N4 variable speed drive - ATV930-5,5kW - 400/480V - with braking unit - IP21

ATV680C45Q4X1 Low Harmonic Drive System ATV /355kW V - IP23

SD328AU68S2 motion control stepper motor drive - SD328 - <= 6.8 A

ATV1200A kv kva

ATV630D30N4 variable speed drive ATV630-30kW/40HP V - IP21/UL type 1

ATV1200A kv kva

ATV1200A kv kva. Phase-shifting transformer Medium voltage arrestors Cooling fans Human machine interface Plinth (2) Power cells (9)

TM3DI16 module TM3-16 inputs

ATV340U15N4 variable speed drive - 1.5kW- 400V - 3 phases - ATV340

ATV630C22N4 variable speed drive ATV kW/350HP V - IP00

ATV650C13N4F. ATV650C13N4F variable speed drive ATV kW V - IP54 - disconnect switch. Product data sheet Characteristics.

ATV320U06N4C variable speed drive ATV kW V - 3 phase - compact

LXM32SD18M2 motion servo drive - Lexium 32-single phase supply voltage 115/230V - 0.5/1.kW

ABL8RPS24100 regulated SMPS - 1 or 2-phase V - 24 V - 10 A

ATV320D11N4B. Product datasheet Characteristics. Main. Complementary 1 / 8. Device short name Format of the drive

ATV930C11N4C variable speed drive - ATV kW - 400/480V - w/o braking unit - IP00

Transcription:

Characteristics variable speed drive ATV12-2.2kW - 3hp - 200..240V - 3ph - with heat sink Main Range of product Altivar 12 Product or component type Product destination Product specific application Assembly style Component name Oct 15, 2018 Variable speed drive Asynchronous motors Simple machine With heat sink ATV12 Quantity per set Set of 1 EMC filter Built-in fan Network number of phases Without EMC filter With 3 phases [Us] rated supply voltage 200...240 V - 15...10 % Motor power kw Motor power hp Communication port protocol Line current 2.2 kw 3 hp Modbus Speed range 1...20 Transient overtorque Asynchronous motor control profile IP degree of protection Noise level Complementary 14.9 A 200 V 12.5 A 240 V 150...170 % of nominal motor torque depending on drive rating and type of motor Quadratic voltage/frequency ratio Sensorless flux vector control Voltage/Frequency ratio (V/f) IP20 without blanking plate on upper part 50 db Supply frequency 50/60 Hz +/- 5 % Connector type Physical interface Transmission frame Transmission rate 1 RJ45 Modbus on front face 2-wire RS 485 Modbus RTU Modbus 4800 bit/s 9600 bit/s 19200 bit/s 38400 bit/s 1 Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications

Number of addresses Communication service Prospective line Isc Continuous output current Maximum transient current Speed drive output frequency Nominal switching frequency Switching frequency Braking torque Motor slip compensation Output voltage Electrical connection Tightening torque Insulation Supply Analogue input number 1 Analogue input type Discrete input number 4 Discrete input type Discrete input logic Sampling duration Linearity error Analogue output number 1 Analogue output type Discrete output number 2 Discrete output type Minimum switching current Maximum switching current Acceleration and deceleration ramps Braking to standstill Protection type Frequency resolution Time constant Marking Operating position 1...247 Modbus Read holding registers (03) 29 words Write single register (06) 29 words Write multiple registers (16) 27 words Read/Write multiple registers (23) 4/4 words Read device identification (43) <= 5 ka 10 A 4 khz 15 A 60 s 0.5...400 Hz 4 khz 2...16 khz adjustable 4...16 khz with derating factor Up to 70 % of nominal motor torque without braking resistor Adjustable Preset in factory 200...240 V 3 phases Terminal 5.5 mm² AWG 10 L1, L2, L3, U, V, W, PA, PC 1.2 N.m Electrical between power and control Internal supply for reference potentiometer 5 V DC 4.75...5.25 V 10 ma overload and short-circuit protection Internal supply for logic inputs 24 V DC 20.4...28.8 V 100 ma overload and short-circuit protection Configurable voltage AI1 0...10 V 30 kohm Configurable voltage AI1 0...5 V 30 kohm Configurable current AI1 0...20 ma 250 Ohm Programmable LI1...LI4 24 V 18...30 V Negative logic (sink) > 16 V < 10 V 3.5 kohm Positive logic (source) 0...< 5 V > 11 V 20 ms +/- 1 ms logic input 10 ms analogue input +/- 0.3 % of maximum value analogue input Software-configurable voltage AO1 0...10 V 470 Ohm 8 bits Software-configurable current AO1 0...20 ma 800 Ohm 8 bits Logic output LO+, LO- Protected relay output R1A, R1B, R1C 1 C/O 5 ma 24 V DC logic relay 2 A 250 V AC inductive cos phi = 0.4 L/R = 7 ms logic relay 2 A 30 V DC inductive cos phi = 0.4 L/R = 7 ms logic relay 3 A 250 V AC resistive cos phi = 1 L/R = 0 ms logic relay 4 A 30 V DC resistive cos phi = 1 L/R = 0 ms logic relay Linear from 0 to 999.9 s S U By DC injection <= 30 s Against input phase loss in three-phase Thermal motor protection via the drive by continuous calculation of I²t Line supply overvoltage Line supply undervoltage Overcurrent between output phases and earth Overheating protection Short-circuit between motor phases 0.1 Hz display unit Converter A/D, 10 bits analog input 20 ms +/- 1 ms for reference change CE Vertical +/- 10 degree 2

Height Width Depth Product weight Specific application Variable speed drive application selection Motor starter type 143 mm 105 mm 131.2 mm 1.2 kg Commercial equipment Commercial equipment : mixer Commercial equipment : other application Textile : ironing Variable speed drive Environment Electromagnetic compatibility Immunity to conducted disturbances level 3 EN/IEC 61000-4-6 Surge immunity test level 3 EN/IEC 61000-4-5 Voltage dips and interruptions immunity test EN/IEC 61000-4-11 Electrical fast transient/burst immunity test level 4 EN/IEC 61000-4-4 Electrostatic discharge immunity test level 3 EN/IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 EN/IEC 61000-4-3 Electromagnetic emission Product certifications Vibration resistance Shock resistance Radiated emissions environment 1 category C2 EN/IEC 61800-3 2...16 khz shielded motor cable Conducted emissions with additional EMC filter environment 1 category C1 EN/IEC 61800-3 4...12 khz shielded motor cable 5 m Conducted emissions with additional EMC filter environment 1 category C2 EN/IEC 61800-3 4...12 khz shielded motor cable 20 m Conducted emissions with additional EMC filter environment 2 category C3 EN/IEC 61800-3 4...12 khz shielded motor cable 20 m CSA C-Tick GOST NOM UL 1 gn EN/IEC 60068-2-6 13...200 Hz 1.5 mm peak to peak EN/IEC 60068-2-6 3...13 Hz drive unmounted on symmetrical DIN rail 15 gn EN/IEC 60068-2-27 11 ms Relative humidity 5...95 % without condensation IEC 60068-2-3 5...95 % without dripping water IEC 60068-2-3 Ambient air temperature for storage -25...70 C Ambient air temperature for operation Operating altitude -10...50 C protective cover from the top of the drive removed 50...60 C with current derating 2.2 % per C > 1000...3000 m with current derating 1 % per 100 m <= 1000 m without derating Offer Sustainability RoHS (date code: YYWW) REACh Compliant - since 0901 - Schneider Electric declaration of conformity Schneider Electric declaration of conformity Reference not containing SVHC above the threshold Reference not containing SVHC above the threshold Contractual warranty Warranty period 18 months 3

Dimensions Drawings Dimensions Drive without EMC Conformity Kit Dimensions in mm b c 143 131.2 Dimensions in in. b c 5.63 5.16 Drive with EMC Conformity Kit Dimensions in mm b1 189.3 Dimensions in in. b1 7.45 4

Mounting and Clearance Mounting Recommendations Clearance for Vertical Mounting Mounting Type A Mounting Type B Remove the protective cover from the top of the drive. Mounting Type C Remove the protective cover from the top of the drive. 5

Connections and Schema Three-Phase Power Supply Wiring Diagram A1 KM1 Q1 Drive Contactor (only if a control circuit is needed) Circuit breaker 6

Connections and Schema Recommended Schemes 2-Wire Control for Logic I/O with Internal Power Supply LI1 : LI : A1 : Forward Reverse Drive 3-Wire Control for Logic I/O with Internal Power Supply LI1 : LI2 : LI : A1 : Stop Forward Reverse Drive Analog Input Configured for Voltage with Internal Power Supply (1) 2.2 kω 10 kω reference potentiometer A1 : Drive Analog Input Configured for Current with Internal Power Supply (2) 0-20 ma 4-20 ma supply A1 : Drive 7

Connected as Positive Logic (Source) with External 24 vdc Supply (1) 24 vdc supply A1 : Drive Connected as Negative Logic (Sink) with External 24 vdc supply (1) 24 vdc supply A1 : Drive 8

Performance Curves Torque Curves 1 : Self-cooled motor: continuous useful torque (1) 2 : Force-cooled motor: continuous useful torque 3 : Transient overtorque for 60 s 4 : Transient overtorque for 2 s 5 : Torque in overspeed at constant power (2) (1) For power ratings 250 W, derating is 20% instead of 50% at very low frequencies. (2) The nominal motor frequency and the maximum output frequency can be adjusted from 0.5 to 400 Hz. The mechanical overspeed capability of the se 9