BASE LOAD UNLOAD 3 PRODUCTS 6 PRODUCTS 14 PRODUCTS Multiprogram

Similar documents
BASE LOAD UNLOAD 3 PRODUCTS 6 PRODUCTS 14 PRODUCTS Multiprogram

IP67 VERSION BOX (on request) 8+3 PG9 cable glands-plugs. 8+3 PVC fittings for sheath

TLB4 TLM8. ERDE-Elektronik AB - Spikgatan Vellinge TLM8den.

Complies with the Eurasian Custom Union regulations (Russia, Belarus, Kazakhstan)

2 Made in Italy Electronic Instruments for weighing and batching LAUMAS produces Weight Indicators and Transmitters for PC/PLC connection to the most

ENGLISH ENGLISH ENGLISH ENGLISH

PENKO Engineering B.V. When Weighing Counts FLEX Multi Channel Extended

WTX120. Legal-for-trade industrial weighing terminal. Special features. Data sheet

C500 Series Data Sheet

Weight Indicator. Model Intuition 22i FEATURES APPLICATIONS DESCRIPTION OPTIONS CONFIGURATION

Characteristics and functioning

ABB MEASUREMENT & ANALYTICS DATA SHEET. IT1 Universal weighing terminal

COMMUNICATION PROTOCOLS

ENGLISH ENGLISH ENGLISH ENGLISH

Presented By. NicolScales.com Contact Us

EC Type-Approval Certificate

T1-transmitter. 4-20mA 0-20mA 0-10V 0-5V +/-5V +/-10V 2014/30/EU EN55022:2010 EN :2005 EN :2007

EU Type Examination Certificate

EC Type-Approval Certificate

CERTIFICATE of EU TYPE-APPROVAL

Installation and User Manual version 1.04 TLM8 2014/30/UE EN55022:2010 EN :2005 EN :2007 SYSTEM IDENTIFICATION

Characteristics and functioning

LAUREL ELECTRONICS, INC.

WTX110. Legal-for-trade industrial weighing terminal. Special features. Data sheet

INSTALLATION MANUAL. LC 200 Electronic Overload Guard. Software versione PW0501 R 0.3

DD2050 Hopper Scale. datasheet

Y800 Plus Frequency, Rate & Period Meter With dual, independently field-scalable channels

MPI-DN, MPI-D MULTICHANNEL ELECTRONIC RECORDER for HART or RS-485/ MODBUS RTU SENSORS

LAUREL. Laureate Pulse or Analog Input Batch Controller Automatic batch control for repetitive liquid fill operations ELECTRONICS, INC.

OIML CERTIFICATE OF CONFORMITY

EC Type Examination Certificate

TRACKER 240 SERIES. Load Cell and Weighing Indicators. A Precision Measurement Instrument with Outstanding Features

Process displays For current and voltage

OIML CERTIFICATE OF CONFORMITY

TECHNICAL DATA. Option: Connection of scale platforms with digital force transducers. Option: up to 6 external scale connection.

Maxxis 4 Process Controller with BASIC Application

The IQ300 wall mount load cell indicator is a precision digital indicator for load cell and strain gauge applications.

LAUREL. Laureate Dual-Channel Pulse Input Totalizer With Two Independently Scalable Input Channels & Presets ELECTRONICS, INC. Features.

INTECONT PLUS for Measuring Systems

DRAFT. Customer site gravity factor. Filtering parameters. Five points for linearity correction to ensure maximum accuracy

The LT1300 wall mount load cell indicator is a precision digital indicator for load cell and strain gauge applications.

enod4 Weighing controller for automated systems

Weight controller Maxxis 5

UniPak UP448 Bridge Input Isolating Signal Conditioner

PT2060 Monitor. PT2060/91 SIM System Interface Module. Specifications. Electrical. Messtechnik

Neon pr. ph/ ORP measurement. Applications. Description

LAUREL. Laureate Digital Panel Meter for Load Cell & Microvolt Input ELECTRONICS, INC. Features. Description

ioselect Z-NET Z-SG Bridge Input Isolating I/O Module

smart meters... 6 panel meters... 7 field displays... 8 display types loop powered displays TRANSMITTERS & CONVERTERS...

User Manual version 1.04 TLM8 COMMUNICATION PROTOCOLS

E1205 advanced multi-function indicator

The IQ240 panel mount load cell indicator is a precision digital indicator for load cell and strain gauge applications.

CERTIFICATE of EU TYPE-APPROVAL

Strain Gauge Converter

enod4 weighing controllers For automated processes

STANDARD TERMINAL. Digital Indicators. Product Number 3020

ENGLISH ENGLISH ENGLISH ENGLISH

Power Meter PowerMonitor 500

Line A. Inverse parallel scrs. Load a FUSION. Line B SCR POWER. O delta CONTROLLERS. Line c. inverse parallel scrs. Load C. FUSION Brochure Rev 3.

Energy Management Modular DC Energy analyzer Type VMU-E and VMU-X

Protocol Manual. Specifications and dimensions are subject to change without notice and do not constitute any liability whatsoever.

1.6. Counters, Panel Meters, Tachometers and Timers. Contents Description Fusion Integrated Machine Control Standards and Certifications...

OIML CERTIFICATE ISSUED UNDER SCHEME A

Transmitter WST 3 From prog. name W001A100. Technical Manual

enod products range Digital process controllers

ENGLISH ENGLISH ENGLISH ENGLISH

Presented By. NicolScales.com Contact Us

LAUREL. MAGNA Series Large Digit Displays for Counter / Totalizer Pulse Input ELECTRONICS, INC. Features. Description

PM174 PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER. Features

Hotel Room Controller

Weight Indicator TAD 3 From prog. name T002L240. Technical Manual

HI 6500 series Quick Start Guide

TC Type Range Conformity Error. J -210 C to +760 C (-347 F to F) ±0.09 C (±0.16 F) K -244 C to C (-408 F to F) ±0.1 C (±0.

General information. Display. Supply voltage

N420 R420 R423. series

LAUREL. Laureate Digital Panel Meter for Process and Ratiometric Signals ELECTRONICS, INC. Features. Description

T1 4-Channel Protocol Manual

LAUREL. Laureate Rate Meter & Totalizer with Functions A+B, A-B, AxB, A/B, A/B-1 ELECTRONICS, INC. Features. Description

General information. Display. Supply voltage. Input current

InteliLite MRS17 Click Here to Learn More

T1-transmitter. 4-20mA 0-20mA 0-10V 0-5V +/-5V +/-10V 2014/30/EU EN55022:2010 EN :2005 EN :2007

M260 Load Cell Amplifiers

RS 485 Mini Modbus 1AO

MICROFUSION FEATURES OPTIONS CERTIFICATIONS (PENDING) THREE PHASE SCR POWER CONTROLLERS

Batch Controller with numerical keypad, remote control inputs and 3 control / alarm / pulse outputs

E1110 multi-function weight indicator

General information. Display. Supply voltage

FUSION COMPACT. Load a. Line A. Inverse parallel scrs. Line B. Line c. inverse parallel scrs. Load C SCR POWER. O delta CONTROLLERS

4 LOOP MODULAR POWER CONTROLLER

Weighing Indicator WE2107

DISOMAT T Weigh Transmitter

INTECONT Tersus Mass flow rate measurement

Indicators. Product Mounting Display Height Page

3000 SERIES LOW PROFILE FLOOR SCALE.

General information. Display. Supply voltage. Input current

Electronic Preset Counter with 2 Presets and Print interface. NE213 Prog Features

1.6 WT 60 BASE 2004/108/EC (EMC) - EN

General information. Display. Supply voltage. Input current

T1-CANopen 2014/30/EU EN55022:2010 EN :2005 EN :2007

LAUREL ELECTRONICS, INC.

Transcription:

PROGRAM BASE LOAD UNLOAD 3 PRODUCTS 6 PRODUCTS 14 PRODUCTS Multiprogram External 8-relay modules included W200 W200-C W200-S W200-3 W200-6 W200-14 ON REQUEST W200-MU CERTIFICATIONS OIML R76:2006, class III, 3x10000 divisions, 0.2 μv/vsi / OIML R61 - WELMEC Guide 8.8:2011 (MID) CERTIFICATIONS ON REQUEST Initial verification in combination with Laumas weighing module UL Recognized component - Complies with the United States and Canada standards Complies with the Eurasian Custom Union standards (Russia, Belarus, Kazakhstan) NMI Trade Approved - Complies with the Australian standards for legal use with third parties FIELDBUSES

DESCRIPTION Weight indicator in DIN box suitable for front panel mounting (dimensions: 96x96x130 mm; drilling template: 92x92 mm). 6-digit red LED semi-alphanumeric display (14 mm height), 7-segment. 8 signalling LED. 5-key membrane keyboard. IP54 front panel protection rating (IP65 front optional). Real-time clock/calendar with buffer battery. Extractable screw terminal blocks. INPUTS/OUTPUTS AND COMMUNICATION RS485/RS232 serial ports for communication via ModBus RTU protocol, ASCII Laumas bidirectional or continuous one way transmission. 5 relay outputs controlled by the setpoint values or via protocols (4 outputs if analog output is present). 3 optoisolated PNP digital inputs: status reading via serial communication protocols (2 inputs if analog output is present). 1 load cell dedicated input. Current or voltage 16 bit optoisolated analog output (option on request). MAIN FUNCTIONS Connections to: - PLC via analog output (on request); - PC/PLC via RS485/RS232 (up to 99 instruments with line repeaters, up to 32 without line repeaters); - remote display and printer via RS485/RS232; - up to 8 load cells in parallel by junction box; - intelligent junction box or other multichannel instruments: allow the use of advanced functions as digital equalization, load distribution analysis and automatic diagnostics. Digital filter to reduce the effects of weight oscillation. Theoretical calibration (via keyboard) and real calibration (with sample weights and the possibility of weight linearization up to 5 points). Tare weight zero setting. Automatic zero setting at power-on. Gross weight zero tracking. Semi-automatic tare (net/gross weight) and preset tare. Semi-automatic zero. Displaying of the maximum weight value reached (peak). Direct connection between RS485 and RS232 without converter. Weight value printing with date and time via keyboard or external contact. TCP/IP WEB APP Integrated software in combination with the Ethernet TCP/IP option for remote supervision, management and control of the instrument. CE-M version: 2014/31/EU-EN45501:2015-OIML R76:2006 System parameters management protected by qualified access via software (password), hardware or fieldbus. Weight subdivisions displaying (1/10 e). Three operation mode: single interval or multiple ranges or multi-interval. Net weight zero tracking. Calibration. Alibi memory (option on request). The following values can be printed via keyboard or external contact: gross weight, net weight, tare, preset tare, date, time, ID code (aliby memory). BASE PROGRAM Hysteresis and setpoint value setting. The indicator can be used as a remote display with setpoints. 12 groups selection by 5 setpoint via external selector switch or contact (option on request). BATCHING PROGRAM 99 settable formulas. Batching resume after a blackout. Automatic fall calculation. Tolerance error control. Precision batching through slow function. Precision batching through tapping function. Consumption storage. Printing of batching data. Alarm contact management. Selection of the first 12 formulas via external selector switch or contact (option on request). Batching start via external contact or keyboard. Only for: LOAD and 3/6/14 PRODUCTS programs Autotare at batching start. UNLOAD program Automatic loading of the product into the weighed structure. Management of batching with big bags. 3/6/14 PRODUCTS program Formulas programming in fixed or variable steps. MULTIPROGRAM The Multiprogram instruments do not have any selected program but can be set by the installer with different operating modes: BASE, LOAD, UNLOAD, 3 PRODUCTS, 6 PRODUCTS, 14 PRODUCTS.

TECHNICAL FEATURES Power supply and consumption 12 24 VDC ±10%; 5 W (on request: 115 230 VAC; 50 60 Hz; 6 VA) Number of load cells Load cells supply up to 8 (350 Ω) - 4/6 wires 5 VDC/240 ma Linearity Analog output linearity Thermal drift Analog output thermal drift A/D Converter Divisions (with measurement range ±10 mv and sensitivity 2 mv/v) Measurement range Usable load cells sensitivity Conversions per second Display range Decimals Display increments Digital filter Readings per second Relay outputs Optoisolated digital inputs Serial ports Baud rate Optoisolated analog output (option on request) Humidity (condensate free) Storage temperature Working temperature <0.01% full scale <0.01% full scale <0.0005% full scale/ C <0.003% full scale/ C 24 bit (16000000 points) - 4.8 khz ±999999 0.01 μv/d ±39 mv ±7 mv/v 300/s ±999999 0 4 x1 x2 x5 x10 x20 x50 x100 10 levels 5 300 Hz 5/4 - max 115 VAC/150 ma 3/2-5 24 VDC PNP RS485, RS232 2400, 4800, 9600, 19200, 38400, 115200 (bit/s) 16 bit = 65535 divisions. 0 20 ma; 4 20 ma (up to 300 Ω) 0 10 V; 0 5 V; ±10 V; ±5 V (min 10 kω) 85% -30 C +80 C -20 C +60 C Relay outputs 5/4 - max 30 VAC, 60 VDC/150 ma Working temperature -20 C +50 C Power supply device marked LPS (limited power source) or Class 2 METROLOGICAL SPECIFICATIONS OF TYPE-APPROVED INSTRUMENTS Applied standards Operation modes Accuracy class Maximum number of scale verification divisions Minimum input signal for scale verification division Working temperature 2014/31/UE - EN45501:2015 - OIML R76:2006 single interval, multi-interval, multiple range III or IIII 10000 (class III); 1000 (class IIII) 0.2 μv/vsi -10 C +40 C 1 2 3 4 5 6 7 8 9 10 11 12 14 15 16 17 18 19 20 21 22 23 24

OPTIONS ON REQUEST AND COMPATIBILITY WITH BATCHING PROGRAMS POWER SUPPLY Power supply 115/230 VAC; 50/60 Hz; 6 VA. Not compatible with fieldbuses and USB port. ACCESSORIES IP65 panel sealing gasket. OPZW96X96IP65 INTERFACES AND FIELDBUSES Optoisolated 16 bit analog output. One input and one output not available. Additional RS485 port. One input and one output not available. Not compatible with E/EC option. CANopen protocol. DeviceNet protocol. Profibus DP protocol. Ethernet/IP protocol - Ethernet port. Ethernet TCP/IP protocol - Ethernet port. Integrated software for remote supervision, management and control of the instrument. Modbus/TCP protocol - Ethernet port. Profinet IO protocol - Ethernet port. OPZW1ANALOGICA OPZW1RS485 OPZW1CAW200 OPZW1DEW200 OPZW1PRW200 OPZW1ETIPW200 OPZW1ETTCPW200 OPZW1MBTCPW200 OPZW1PNETIOW200 USB port for data storage to pen drive (included). These data (weighed values, batchings, alarms) can be imported and processed on the PC using the PROG-DB software included in the supply. Select one option among those marked with an asterisk. OPZWUSBW200

OPTIONS ON REQUEST AND COMPATIBILITY WITH BATCHING PROGRAMS USB male/female extension cable with IP68 sealed panel connector; lenght 50 cm, sealing cap and cover included. OPZWCONUSBIP68 Ethernet male/female extension cable with IP68 sealed panel connector; lenght 50 cm, sealing cap included. OPZWCONETHEIP68 Ethernet male/male extension cable with IP68 sealed connector; lenght 5 m, to be used in combination with the OPZWCONETHEIP68 option. Weight reading from 0-10 VDC input (15 kω). Weight reading from 4-20 ma input (120 Ω). OPZWCONETHE5MT OPZWING010 OPZWING420 EXPANSIONS Base: 12 groups selection by 5 setpoint via external selector switch. Load, Unload, 3/6/14 Products: selection of the first 12 formulas via external selector switch. EC Base: 12 groups selection by 5 setpoint via external contact. Load, Unload, 3/6/14 Products: selection of the first 12 formulas via external contact. Simultaneous use of E/EC option with the analog output. E OPZWAEC External 5-relay module to increase the capacity of SPDT contacts to 115 VAC/2 A. RELE5M External 8-relay module to manage from 1 to 6 products; 8 relays up to max 115 VAC/2 A. Module included with models 6/14 PRODUCTS. Select one option among those marked with an asterisk. 12 24 VDC RELE6PROD24V 115 VAC RELE6PROD115V 230 VAC RELE6PROD230V inc. inc.

OPTIONS ON REQUEST AND COMPATIBILITY WITH BATCHING PROGRAMS External 8-relay module to manage from 7 to 14 products to be added to RELE6PROD module; 8 relays up to max 115 VAC/2 A. Module included with model 14 PRODUCTS. RELE14PROD inc. APPLICATIONS - SOFTWARE Formulas setting in percentage. Setting a quantity to be batched greater than the scale capacity with automatic calculation of cycles. Not available for CE-M approved version. Intermediate unloadings during the batching. Not available for CE-M approved version. Partial unloadings at cycle end. Not available for CE-M approved version. Alibi memory. OPZWFORPERC OPZWQMC OPZWSCARI OPZWSCARP OPZWALIBI Data transfer from the instrument to the PC, via RS232 (directly) or RS485 (by converter) serial port. These data (weighed values, batchings, alarms) can be imported and processed on the PC using the PROG-DB software included. We suggest to use this option when the indicator is always connected to the PC. OPZWDATIPC Manual batching with remote displays connected in parallel to the instrument via RS485 serial port; allows to display on different remote displays the following batching information: formula and product number, remaining quantity to be batched, gross weight. OPZWLAUMAN The Company reserves the right to make changes to the technical data, drawings and images without notice.