Workflow Guide Slide(s) Topic 2-6 Importing Data and Labeling Samples 7-11 Processing Data Without an Allelic Ladder Processing Data With an

Similar documents
GeneMarker HID Quick Start

Gene. The Biologist Friendly Software. Quickstart Guide

Configuring GeneMapper ID Software

You will see the difference!

Geneious Microsatellite Plugin. Biomatters Ltd

Quick Guide FAST HR. For more resources, including a guide on FAST HR codes, visit # Instructions Screenshot

Procedure for GeneMapper ID. 1.0 Purpose To specify the steps for performing analysis on DNA samples using GeneMapper ID (GMID) software.

LEGENDplex Data Analysis Software Version 8 User Guide

Forms/Distribution Acrobat X Professional. Using the Forms Wizard

Troubleshooting in Microsoft Excel 2002

MICROSOFT WORD 2010 BASICS

Creating Fill-able Forms using Acrobat 7.0: Part 1

Microsoft How to Series

Working with Charts Stratum.Viewer 6

Microsoft Word (97, 98, 2000) Word Processing Instructions

How To Capture Screen Shots

Quick Start Guide. ARIS Architect. Version 9.8 Service Release 2

File Extensions Project (LucidChart Version) Computational Media. Description:

cief Data Analysis Chapter Overview Chapter 12:

Solo 4.6 Release Notes

Developing a Power Point Presentation

IMAGE STUDIO LITE. Tutorial Guide Featuring Image Studio Analysis Software Version 3.1

USER GUIDE. MADCAP FLARE 2017 r3. Import

Gradebook Entering, Sorting, and Filtering Student Scores March 10, 2017

ABI PRISM GeneMapper Software Version 3.0 SNP Genotyping

Operating instructions for MixtureCalc v1.2 (Freeware Version)

San Pedro Junior College. WORD PROCESSING (Microsoft Word 2016) Week 4-7

Open. Select the database and click. Print. Set printing options using the dropdown menus, then click the

Using Microsoft Word. Paragraph Formatting. Displaying Hidden Characters

GeneMapper ID-X Software

MICROSOFT WORD. MS. Office includes the following application:

AudaEnterprise Gold User Guide

PowerPoint 2016 Basics for Mac

SystemVue 2011 Fundamentals (version ) LAB EXERCISE 1. SystemVue Basics

How To Capture Screen Shots

Advanced Excel for EMIS Coordinators

AEMLog Users Guide. Version 1.01

MockupScreens - User Guide

Microsoft Word Part I Reference Manual

USER GUIDE MADCAP FLARE Topics

Quick Start Guide. ARIS Architect. Version 9.7

Getting Started. Custom Reports Software

Candy is Dandy Project (Project #12)

Chromeleon software orientation

CellaVision Proficiency Software

Status Bar: Right click on the Status Bar to add or remove features.

Excel 2007 New Features Table of Contents

Creating a PowerPoint Presentation

Introduction to Microsoft Excel 2010 Quick Reference Sheet

Excel Select a template category in the Office.com Templates section. 5. Click the Download button.

Excel 2003 Tutorial II

DIPSorter User Manual. In combination with Biotype s Mentype DIPplex PCR Amplification Kit Software version: 1.0.2

CEQ 8000 Series Fragment Analysis Training Guide

Applied Biosystems TrueScience Aneuploidy STR Kits

Scheduling Book Set-Up & Check-In Preferences

1. AUTO CORRECT. To auto correct a text in MS Word the text manipulation includes following step.

BEST PRACTICES. Checkpoint Engage with AdvanceFlow

Introducing Gupta Report Builder

Importing data in a database with levels

EXCEL BASICS: MICROSOFT OFFICE 2007

TraceFinder Analysis Quick Reference Guide

CONTASign Pro User Manual

BEST PRACTICES. Checkpoint Engage with AdvanceFlow

EXCEL + POWERPOINT. Analyzing, Visualizing, and Presenting Data-Rich Insights to Any Audience KNACK TRAINING

ARIS Architect QUICK START GUIDE. Version Service Release 7

DDX-R Quick Start Guide

Microsoft Excel 2010 Part 2: Intermediate Excel

5.2. Click these tabs to jump to the Table of Contents, Index or start of each chapter.

Importing and processing a DGGE gel image

Welcome to MicroStation

Training Guide. Microsoft Excel 2010 Advanced 1 Using Conditional and Custom Formats. Applying Conditional Formatting

6. In the last Import Wizard dialog box, click Finish. Saving Excel Data in CSV File Format

.txt - Exporting and Importing. Table of Contents

TraceFinder Analysis Quick Reference Guide

Getting Started Guide. Chapter 3 Using Styles and Templates

Adobe Photoshop CS2 Reference Guide For Windows

Working with PDF s. To open a recent file on the Start screen, double click on the file name.

TestAnyTime User Manual (Imaging) English Version

EXCEL 2013 FDLRS SUNRISE

Getting Started Guide. Chapter 3 Using Styles and Templates

SAMaRT User Guide Microsoft Excel (Advanced version)

3. Click the Change Case button. 4. On the menu, click the desired case option. Managing Document Properties

You can also search online templates which can be picked based on background themes or based on content needs. Page eleven will explain more.

Excel 2013 for Beginners

DataMaster for Windows

SharePoint 2010 Site Owner s Manual by Yvonne M. Harryman

Form Guide. Table of Contents. Page 1. Body Linked Objects

OpenForms360 Validation User Guide Notable Solutions Inc.

Word 2013 Quick Start Guide

3.2 Circle Charts Line Charts Gantt Chart Inserting Gantt charts Adjusting the date section...

Data Should Not be a Four Letter Word Microsoft Excel QUICK TOUR

SAMPLE - NOT LICENSED

Remark Office OMR. Tutorials

Changing the Layout of a Document

Fusion. CBR Fusion MLS Level 1 Core Functions. Class Handout

Microsoft Excel 2010 Tutorial

Step-by. A Very Warm Welcome to the Exciting World of Computers. Let s get Started It s easy with my Step- Instructions

Dreamweaver Basics. Planning your website Organize site structure Plan site design & navigation Gather your assets

MS PowerPoint Useful Features. Choose start options. Change Office backgrounds and colours

Devyser QF-PCR. Guide to Sample Runs, Data Analysis & Results Interpretation

Transcription:

Workflow Guide Slide(s) Topic 2-6 Importing Data and Labeling Samples 7-11 Processing Data Without an Allelic Ladder 12-23 Processing Data With an Allelic Ladder 24-30 Reviewing Size and Allele Calls 31-37 Automated Chimerism Analysis 38-40 Longitudinal Report 41-43 Adding Samples to a Project 44-45 Double Donor Analysis 46-52 Troubleshooting 53 More Information

2-Importing Files To get started, import your data files. Navigate to File, and then Open Data. Click Add and navigate to your raw data files.

3-Importing Files Select your raw data files and then click Open, and then click OK in the Open Data Files window. Shortcuts: Hold Shift to select multiple files at once, or click and then hold Ctrl and A to select every file.

4-Importing Files The sample traces are now displayed in the Main Analysis Window. Double click on a sample file name to show or hide the trace. Draw a box from left-to-right to zoom in on an area; draw a box from right-to-left to zoom out. Click the Dye Color Icon: to display different dye colors.

5 - Setting Sample Types Notice that the Donor and Recipient files are highlighted. In the View -> Preferences menu, under the Chimerism tab, you may enter keywords that the program will use to automatically recognize specific file types.

6 Setting Sample Types You can also manually enter a file s type by simply right clicking on the file and mouse-ing over Set Sample Type.

7 Processing Data Without an Allelic Ladder Processing Data Without An Allelic Ladder You are now ready to process your data. However, the workflow of ChimerMarker differs depending on whether or not you choose to run an Allelic Ladder with your samples. The following section covers data processing Without a ladder. If you use a ladder in your analysis, please skip ahead to the next section, beginning on slide 12.

8 Processing Data Without an Allelic Ladder Process you samples by navigating to Project -> Run, or by clicking the green triangle icon. Note: set your sample types (donor, recipient, etc.) before processing your data. From each drop-down menu, select your precalibrated Genotyping Panel, Size Standard, and Standard Color, or simply click the corresponding pre-saved template. To create a new template, input a new template name and click the save button.

9 Processing Data Without an Allelic Ladder The second page of the Run Wizard includes parameters that govern how size and allele calls are made. The default settings are suitable for most analyses. Be sure to select Only Call Alleles in CHM Panel and Auto Create CHM Panel. With these options selected, ChimerMarker will create a project-specific Chimertyping Panel from your Genotyping Panel. Give a name to this new panel in the field above.

10 Processing Data Without an Allelic Ladder If you aren t using an allelic ladder, ensure that Auto Select Best Ladder and Auto Panel Adjustment are unselected. Click OK to process your data.

11 Processing Data Without an Allelic Ladder Now the data has been successfully processed. To begin reviewing your data, please skip ahead to the section titled Reviewing Size and Allele Calls, beginning on slide 24. Note: If you notice that some high quality peaks aren t being called by the software, please visit the Troubleshooting section, beginning on slide 46.

12 Processing Data With an Allelic Ladder Processing Data With An Allelic Ladder The workflow of ChimerMarker differs depending on whether or not you choose to run an Allelic Ladder with your samples. The following section covers data processing With a ladder. If you don t use a ladder in your analysis, please look over the preceding section, beginning on slide 7.

13 Processing Data With an Allelic Ladder Process you samples by navigating to Project -> Run, or by clicking the green triangle icon. Note: set your sample types (donor, recipient, and ladder) before processing your data. From each drop-down menu, select your Genotyping Panel, Size Standard, and Standard Color, or simply click the corresponding pre-saved template. To create a new template, input a new template name and click the save button.

14 Processing Data With an Allelic Ladder The second page of the Run Wizard includes parameters that govern how size and allele calls are made. The default settings are suitable for most analyses. Be sure that Only Call Alleles in CHM Panel and Auto Create CHM Panel are not selected.

15 Processing Data With an Allelic Ladder Select Auto Select Best Ladder and Auto Panel Adjustment. With these options selected, ChimerMarker will identify the best ladder sample for each sample file, and use it to create a better aligned Genotyping Panel.

16 Processing Data With an Allelic Ladder The data has now been initially processed. The data may look as though it s of poor quality, but this is because many peaks are flagged due to ploidy and heterozygous imbalance. At this stage, the alignment of the panel is most important.

17 Processing Data With an Allelic Ladder If the ladder sample is in bold, it means that the program was able to align the bins of the genotyping panel to the peaks of the ladder sample, creating a new shifted panel. Navigate to the Panel Editor (Tools -> Panel Editor) to save the newly created panel.

18 Processing Data With an Allelic Ladder Observe that that are now two Project Panels: the original genotyping panel, and a second panel, whose bins have been aligned to the allelic ladder sample.

19 Processing Data With an Allelic Ladder Save the newly created panel by clicking on it, and then navigating to File -> Save As New Panel. Give the new panel a name. After clicking OK, you should see the panel appear in the Panel Templates list. You may also export the panel by right clicking on it and selecting Export.

20 Processing Data With an Allelic Ladder Now, repeat the analysis using your shifted panel. Newly saved panels appear at the bottom of the panel dropdown list.

21 Processing Data With an Allelic Ladder For the second run, select Auto Create CHM Panel and Only Call Alleles Present in CHM Panel. With these options selected, ChimerMarker will create a project-specific Chimertyping Panel from your Genotyping Panel. Give a name to this new panel in the field above.

22 Processing Data With an Allelic Ladder Finally, in the last window of the Run Wizard, deselect Auto Select Best Ladder and Auto Panel Adjustment.

23 Processing Data With an Allelic Ladder Now a properly aligned Chimertyping Panel has been made and applied to the samples. The next section covers reviewing size and allele calls.

24 Reviewing Size and Allele Calls The next group of slides demonstrates the process of reviewing size and allele calls, in preparation for Chimerism Analysis. File Tree Electropherogram(s) Allele Report Table

25 Reviewing Size Calls Sizing quality is indicated by the icon to the left of each file name. Green indicates successful size calling. Red and Yellow icons indicate that a size call requires review. Click the Size Calibration Icon: to visualize size calls for each sample. Most size calling errors result from using the wrong size standard, or selecting the wrong standard color.

26 Reviewing Allele Calls During data processing, a Chimertyping panel is created and applied to your data. This panel includes bins for donor, recipient, and shared peaks only. Recipient The program labels each bin according to its origin: R for recipient, D for donor, and D1R for shared peaks. Mixture Donor

27 Reviewing Allele Calls Allele calls are summarized in the Report Table. Again, a color scheme is used to denote quality. Green icons indicate the peak passed all analysis parameters. Yellow icons indicate the peak is in the check range for at least one parameter, and red icons indicate the a peak failed at least one analysis parameter. The format of the report table can be modified extensively by clicking on the Report Settings Icon: The table can be exported as an excel or text file by clicking the Save icon:

28 Reviewing Allele Calls The Report Table is linked with the Electropherogram. Simply double click on an allele call to be taken to the corresponding peak trace.

29 Reviewing Allele Calls To obtain more information about an allele call, click on the Show Chart/Table Icon:

30 Reviewing Allele Calls To edit an allele call, simply right click on the corresponding peak bin and choose which action you d like to take. Notice that the Allele table is updated to show what action the user has taken.

31 Automated Chimerism Analysis After reviewing your Size and Allele Calls proceed to the Chimerism Analysis Application. Select your preferred Chimerism Type and Quantification Method. The default settings are recommended for the remaining parameters. Under the Additional Settings tab, you can set a limit of detection threshold, and choose to display stutter-adjusted Chimerism results.

32 Automated Chimerism Analysis Overview of Chimersim Analysis Window File Tree Results Table Electropherogram(s)

33 Automated Chimerism Analysis To view multiple traces at once, click on the Multiple Sample View icon and select which additional traces to include. (These traces are displayed in addition to the currently selected trace.) Note: Uninformative markers are highlighted in Red.

34 Automated Chimerism Analysis Marker specific and total average Chimerism for each sample are displayed in the central report table. For more information, use the Help dropdown menu.

35 Automated Chimerism Analysis Click on the Patient Information icon to input patient specific information. These details are included in the headers of print reports.

36 Print Options To print a standard report, click the printer icon and select Standard Print. Use the settings window to customize the report.

37 Print Options To print individual markers, use the Individual Marker Print. Again, use the settings window to format the report.

38 The Longitudinal Report Another informative report is the Longitudinal Report. To access it, navigate to Tool -> Longitudinal Report, or click the Longitudinal Report icon: The Longitudinal Report will initially be blank. To add samples, use the green Check-Mark icon: Choose which samples you d like to add to the report and click OK.

39 The Longitudinal Report Once samples are added, the Longitudinal Report should look something like the chart shown below. The longitudinal report is excellent for displaying the trend of chimerism over time.

40 The Longitudinal Report To print the Longitudinal Report, click the Print Icon: Use the Print Settings window to customize the report, and click OK. To save the report as a JPEG or PNG image, click the Save Icon:

41 Adding Samples to Project In ChimerMarker, projects can be saved in their entirety by navigating to File -> Save Project Reopen a saved project by navigating to File -> Open Project

42 Adding Samples to a Project To add a sample to a project, navigate to File -> Add Samples To Project. The project panel and analysis parameters will be applied to the newly added sample. Chimerism results will now be displayed for the new sample, and the sample cab be added to the Longitudinal Report as well.

43 Adding Samples to Project To add a sample to the longitudinal report, click the green check-mark icon: Only samples that haven t already been added to the report are displayed.

44 Double Donor Analysis The workflow of Double Donor Analysis is identical to that of Single Donor analysis. However, remember to identify all sample types (Donor1, Donor2, and Recipient) prior to data processing. And of course, when the time comes select Double-Donor Chimerism Analysis instead of single donor analysis.

45 Double Donor Analysis Donor 1 Donor 2 Colored flags are used to denote bins from Donor1, Donor2, the Recipient, or some combination of the three. Pre-Recipient In the Chimerism Analysis window, Donor1 and Donor2 chimerism results, and their corresponding errors, are calculated and displayed separately. Mixture

46 Troubleshooting After processing your data, you may find that some peaks or markers aren t being called. To investigate this further, navigate to the Panel Editor, which is under Tools -> Panel Editor

47 Troubleshooting The Panel Editor displays the alignment of your samples to various panel templates. The Project Panel is the panel that was used to process your data. Click on a panel to see it superimposed on your sample peaks.

48 Troubleshooting Because the Chimertyping panel is derived from the genotyping panel, misalignments in the Chimertyping panel are typically the result of misalignments in the Genotyping Panel. Chimertyping Panel Genotyping Panel

49 Troubleshooting You can manually align markers and allele bins in the panel editor by holding Shift, and Clicking on the marker name or allele bin. Continue to hold Shift and the Mouse key, and drag the mouse left or right. When you have shifted the marker or bin to your desired location, release the mouse key and the shift key. Save your changes, and then reprocess your samples with the newly shifted panel.

50 Troubleshooting Properly aligned bins in the genotyping panel produce well aligned bins in the Chimertyping Panel Chimertyping Panel Genotyping Panel

51 Troubleshooting In ChimerMarker 3.0.2, you can use the Fixed Bin Width feature as an alternative solution to this problem. This option widens the bins of the Chimertyping panel to the width input by the user.

52 Troubleshooting With this option selected, the program will widen the bins of a newly created Chimertyping panel. This will aid in calling slightly misaligned peaks that would have otherwise been missed. Main Analysis Screen Panel Editor

53 More Information All of the information described in this guide and more can be found in ChimerMarker s linked User Manual. Find it under Help -> Help

Please send any questions to tech_support@softgenetics.com Or please call 814-237-9340