MODELS DPDT DPDT DPDT-60MS DPDT-60MS

Similar documents
SP SP-T-9

PC-200-LLC-GM INSTALLATION INSTRUCTIONS. Revision A1 Rapid City, SD, USA, 10/2009 II_PC-XXX-LLC-GM_A1

INSTALLATION INSTRUCTIONS. Revision C1 Rapid City, SD, USA, 02/2010 MODEL ALT-XXX-3-SW

MODEL CIO-EN MODBUS/TCP, MODBUS/RTU I/O MODULE

BE SURE POWER IS DISCONNECTED PRIOR TO INSTALLATION! FOLLOW NATIONAL, STATE AND LOCAL CODES! READ THESE INSTRUCTIONS ENTIRELY BEFORE INSTALLATION.

PHASE MONITOR RELAYS Product Summary

78 Series Electromechanical Relay Selection Guide

RE22R2CMR Off-delay Timing Relay s 300h V AC/DC - 2C/O

RE22R2KMR Off-delay Timing Relay s 10min V AC/DC - 2C/O

RE22R2QGMR Star-Delta Timing Relay s 300h V AC/DC - 2C/O

RE22R2AMR On-delay Timing Relay s 300h V AC/DC - 2C/O

RM22TG. Product data sheet Characteristics. three-phase control relay Vac, 2 C/O. Main. Complementary. Network number of phases

CompactBlock Guard I/O EtherNet/IP Safety Modules

Electronic timer CT-AHD.22

RE22R2QTMR Star-Delta Timing Relay s 300h V AC/DC - 2C/O

PGR-3200 MANUAL INSULATION MONITOR

IPS INTELLIGENT PUMP STARTER

02/11/2015

RE22R2AMR On-delay Timing Relay s 300h V AC/DC - 2C/O

RE22R1QMQ star-delta timing relay - 230VAC/440VAC - 1 C/O

ABL8BBU24200 battery control module V DC - 24 V - 20 A - for regulated SMPS

Output Voltage* (nom.)(adjustable)

Safety Standards. Model Number: Unit Weight:

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

Electronic timer CT-ERD.12

08/07/2015

02/11/2015

www. ElectricalPartManuals. com .Basler Electric BE1-878 HIGH IMPEDANCE BUS DIFFERENTIAL RELAY ADVANTAGES ADDITIONAL INFORMATION APPLICATION Page2

Electronic timer CT-ERS.21

Contact protection relay

RM35JA32MR Current control relay 0.15A 15A, 2 C/O

Model Number Structure

G3PC. Model Number Structure. Solid State Relays with Failure Detection Function. Model Number Legend

D64RP18 INSTRUCTION MANUAL N.O. N.C V AC/DC TEST/ RESET

ICS Regent. Relay Output Modules. Low Power and High Power (T3446L and T3446H) PD-6017

ATS22C11S6U soft starter-ats22-control110vpower208v(30hp)/230v(40hp)/460v(75hp)/575v(100h

Redundancy unit CP-A RU

RE22R1QMQ star-delta timing relay - 230VAC/440VAC - 1 C/ O

VER05 Series. xxx Series. 5 Watt. AC-DC Power Supplies. Models & Ratings. Input. Output

Power supply CP-C 24/5.0

Output Voltage* (nom.)(adjustable)

Smartstart Control Module

IES User Manual. 8 FE + 1 MM SC Unmanaged Switch -40 to 75, DIN-rail. v

RM22LA32MR Level control relay RM22-L V AC/DC - 2 C/O

Embedded I/O Expansion Board with 10 Outputs

NI REM Remote I/O Overview DATASHEET. Digital Output Module for Remote I/O

ICS Regent. AC Guarded Digital Output Module 110 VAC (T3464) PD-6021

RE22R1AMR On-delay Timing Relay s 300h V AC/DC - 1C/O

Bulletin 290/291 ArmorStart LT Distributed Motor Controllers Specifications

SMARTSTART MOTOR STARTERS

NEW Series SSH Output to 75A, 510 Vac with Diagnostics High Industrial Performance (HIPpak) Solid-State Relays

ABL8BBU24400 battery control module V DC - 24 V - 40 A - for regulated SMPS

93 SERIES. Timed socket for 34 series 93.68/93.69

NI REM Remote I/O Overview DATASHEET. Digital Input Module for Remote I/O

OVERLOAD RELAYS POWER & ACTUATION PROVEN. series

AND OPTIONAL ACCESSORIES

Phase loss monitor CM-PBE Phasemonitor for over and undervoltage CM-PVE Ordering details

Electronic timer CT-ERS.12 ON-delayed with 1 c/o contact Data sheet

KILOVAC WD Series, DIN Rail or Screw Mounted Protective Relays

RE17LAMW on-delay timing relay - 1 s..100 h V AC/ DC - solid state output

Safety Standards. Model Number:

Messaging module CP-C MM

RE17LCBM off-delay timing relay - control - 1 s..100 h V - solid state output

Rugged MediaConverter

VEL05 Series. xxx Series. 5 Watt. AC-DC Power Supplies. Models & Ratings. Input

Flomatic Smart Card TM Model FDHC-100 (Digital High-Resolution Controller) Configuration and Operation Manual

ATS22C41Q soft starter-ats22-control 220V-power 230V(110kW)/ V(220kW)

Motor Controllers AC Semiconductor Motor Controller Type RSHR MIDI

ABL4RSM24050 regulated SMPS - 1 or 2 phase V AC - 24 V - 5A

SE-601 MANUAL DC GROUND-FAULT MONITOR

RT4F-120V/20A-WAC RECTIFIER

Electronic timer CT-EBD.12 Flasher starting with ON with 1 c/o (SPDT) contact

Industrial Power Supplies

Chrome DC-UPS Module 24V 10A / DRU-24V10ACZ

Motor Controllers AC Semiconductor Motor Controller Type RSHR MIDI

Multifunctional time delay relay MFT U31S, MFT U41SE

Safety Mats & Area Guarding

ACCESS 9340/9360 Meter Input/Output Module

Part No. Description Product Life Cycle Phase *) unit, 24 VDC, spring terminals. unit, 24 VDC, spring terminals, XC version

ATS22C21S6U softstarter-ats22-control110vpower208v(60hp)/230v(75hp)/460v(150hp)/575v(200hp)

NI REM Remote I/O Overview DATASHEET. Bus Coupler for Remote I/O

www. ElectricalPartManuals. com l Basler Electric MPS100 MOTOR PROTECTION SYSTEM ADVANTAGES WINDOWS SOFTWARE ADDITIONAL INFORMATION

060AAS19 B MDS. MDS Medical AC-DC Adapter 19Volt, 60Watt / MDS-060AAS19 B. Highlights & Features. Safety Standards. Model Number: General Description

RTU511. Binary Output 23BO62. Characteristics. Application. Data Sheet Binary Output 23BO62. The binary output is made via relay contacts.

70 SERIES. Line monitoring relay

RM35UB3. Product data sheet Characteristics. voltage control relay RM35-U - range V AC. Main. Complementary

Three-phase monitoring relay

Energy Management BUS Adapter Type VMU-B

PHOENIX CONTACT - 08/2009. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

ICS Regent. Monitored Digital Input Modules 24 VDC (T3411) PD-6031

RM35TF V AC

Allen-Bradley PLCs. 100 Programmable Controller Processor Unit -Catalog Nos LPI01, -LP102, -LP103, -LP104 SLC TM. The Unit

Power supplies.

RE48ATM12MW on-delay timing relay s..300 h V AC - 2 OC

ATS-16 HV USER MANUAL. Automatic Transfer Switch 16A / 230Vac V090318

Autodaptive Capacitor Control M 2501B

VEL05 Series. xxx Series. 5 Watt. AC-DC Power Supplies. Models & Ratings. Input

Chrome DIN Rail Power Supply 5V 7.5W 1 Phase (Class II & NEC Class 2) / DRC-5V10W1AZ

ATS22D75Q soft starter-ats22-control 220V-power 230V(18.5kW)/ V(37kW)

RM17UB3. Product data sheet Characteristics. voltage control relay RM17-U - range V AC. Main. Complementary

Transcription:

INSTALLATION INSTRUCTIONS Revision B1 Rapid City, SD, USA, 03/2010 MODELS 201-100-DPDT 201-200-DPDT 201-100-DPDT-60MS 201-200-DPDT-60MS II_201-XXX-DPDT_B1 II-201-DPDT-B

BE SURE POWER IS DISCONNECTED PRIOR TO INSTALLATION! FOLLOW NATIONAL, STATE AND LOCAL CODES. READ THESE INSTRUCTIONS ENTIRELY BEFORE INSTALLATION. SymCom s MotorSaver Model 201-XXX-DPDT is a voltage monitor designed to protect 3-phase motors regardless of size. The MotorSaver is used on 120V or 240V, 50/60 Hz motors to protect from damage caused by single-phasing, low voltage, phase-reversal, and voltage unbalance. The 201-XXX-DPDT products feature two isolated Form C relay outputs. CONNECTIONS 1. Mount the MotorSaver in a convenient location in or near the motor control panel. If the location is wet or dusty, it should be mounted in a NEMA 4 or 12 enclosure. 2. Mount an 11-pin socket to the motor control back panel (SymCom P/N OT11-PC, sold separately, is required for UL rating). 3. Connect L1, L2 and L3 (terminals 5, 6 & 7 on the relay socket) to the LINE SIDE of the motor starter (Figure 2). 4. Connect the output relays to the circuitry to be controlled. See Figure 1 for pin-out diagram. The output relays are isolated, so different control voltages may be applied to each one. For motor control, connect a normally open contact in series with the magnetic coil of the motor starter as shown in Figure 2. For alarm operation, connect a normally closed contact in series with the control circuit as shown in Figure 2. 5. Plug the relay into the relay socket.

3 4 L1 2 5 L2 6 1 11 L3 7 8 9 10 Figure 1: Pin-Out Diagram Figure 2: Typical Motor and Alarm Control Wiring Diagram

SETTING LINE VOLTAGE ADJUSTMENT: Rotate the VOLT ADJUSTMENT (VAC) knob to the nominal 3- phase line voltage feeding the motor to be protected. OPERATION Figure 3: Voltage Adjustment (201-200-DPDT Model Shown) Apply 3-phase power to the motor. The MotorSaver s green RUN light will blink during the one second 1 restart delay. Once the restart delay time has expired, the MotorSaver will energize its output contacts (open the normally closed and close the normally open contacts) and the green RUN light will illuminate. If the contacts do not energize and the green RUN light does not illuminate, see the troubleshooting section. STATUS RUN RESTART DELAY REVERSE-PHASE UNBALANCE / SINGLE-PHASE LOW VOLTAGE LIGHT PATTERN NEMA MG1 UNBALANCE FORMULA Table 1: Diagnostic Indicator Lights % Voltage Unbalance = Maximum Deviation from the Average x 100% Average Example: The measured line-to-line voltages are 203, 210, and 212. Average = 203 + 210 + 212 = 208.3 3 The maximum deviation from the average is the largest difference between the average voltage (208.3) and any one voltage reading. 208.3-203 = 5.3 210-208.3 = 1.7 212-208.3 = 3.7 The maximum deviation from the average is 5.3. 5.3 x 100 = 2.5% unbalance 208.3 1 Models 201-XXX-DPDT-60mS have a 60mS restart delay

TROUBLESHOOTING SYMPTOM No lights are on - the unit seems completely dead Red light is blinking (on initial power-up) Red light is blinking (after the motor has previously been running) Red light is blinking in this pattern LIGHT PATTERN N/A SOLUTION Measure the three line-to-line voltages. If any of the voltages are below the specified operating voltage, the MotorSaver does not have enough power to operate its internal electronics. See specifications for allowable voltage ranges. If the voltages are correct, call SymCom at (800) 843-8848 or (605) 348-5580. Turn off the 3-phase power. Swap any two leads powering the MotorSaver (L1, L2, or L3) There is a 50-50 chance of connecting L1, L2 and L3 correctly the first time. Reapply 3-phase power. The incoming lines have been reverse-phased. The MotorSaver is preventing the motor from running backwards. Correct the phase sequence. The voltage is unbalanced or single-phased. Measure the incoming line voltages and calculate the % unbalance. If the voltage unbalance does not exceed the 4.5% unbalance reset value, call SymCom at (800) 843-8848 or (605) 348-5580. Red light is on steady The voltage is low. Measure the three line-toline voltages. Calculate the average. If the average is 7% or more below the nominal voltage as selected by the LINE VOLTAGE ADJUST, the MotorSaver is functioning properly. If the voltage is within 7%, call SymCom at (800) 843-8848 or (605) 348-5580. Green light blinks and motor is not running Green light is on steady, but motor does not start The MotorSaver is timing through the restart delay and will energize its contacts when finished. The MotorSaver is in run mode. Ensure other control devices are allowing the motor to start. Check control circuit for loose wires or malfunctioning switches.

DIMENSIONS *The OT11 socket is 35mm DIN rail compatible. The use of OT11 socket is required for Models 201-XXX-DPDT to qualify as UL Listed devices.

MOTOR SAVER 201-XXX-DPDT SPECIFICATIONS Functional Characteristics Adjustments/Settings Low Voltage (% of setpoint) Trip 90%±1% Reset 93%±1% Voltage Unbalance Trip 6% Reset 4.5% Trip Delay Time Low voltage and unbalanced voltage 4 seconds 0.5 seconds Single-phasing faults (>15%UB) 2 seconds 0.5 seconds Reset Delay Times After a fault 2 seconds 60 milliseconds After a complete power loss 2 seconds 60 milliseconds Input Characteristics 3-Phase Line Supply Voltage 201-100-DPDT (-60mS) 95-120VAC 201-200-DPDT (-60mS) 190-240VAC Frequency 50/60 Hz Output Characteristics Output Contact Rating - DPDT Pilot Duty 480VA @ 240VAC General Purpose 10A @ 240VAC General Characteristics Environmental Ambient Operating Temperature 2-40 to 70 C (-40 to 158 F) Relative Humidity 10-95%, non-condensing per IEC 68-2-3 Maximum Input Power 5 W Standards Passed Electrostatic Discharge (ESD) IEC 61000-4-2, Level 3, 6kV contact, 8kV air IEC 61000-4-2, 3kV contact, 6kV air Radio Frequency Immunity, Radiated 150 MHz, 10V/m Fast Transient Burst IEC 61000-4-4, Level 3, 3.5kV input power and controls IEC 61000-4-4, Level 3, 2.5kV input power and controls Surge Immunity IEC IEC 61000-4-5, Level 3, 4kV line-to-line; Level 4, 4kV line-toground ANSI/IEEE C62.41 Surge and Ring Wave Compliance to a level of 6kV lineto-line Hi-Potential Test Meets UL508 (2 x rated V +1000V for 1 minute) Safety Marks UL listed (OT11 octal socket required) UL508 (File #E68520) CE IEC 60947-6-2 Dimensions 2.330 H x 2.375 W x 4.125 D (with socket) Weight 9 oz Enclosure Polycarbonate Mounting Method Plugs into 11-Pin OT11 Socket Wire Gauge 12-22 AWG Solid or Stranded Terminal Torque for P/N OT11 Socket 12 in.-lb. 2 The ambient air temperature is the air temperature directly surrounding the product.