ATV320U15N4C. Product datasheet Characteristics. Main. Complementary 1 / 7. Device short name Format of the drive

Similar documents
ATV320U04N4C variable speed drive ATV kW V - 3 phase - compact

ATV320U06N4C variable speed drive ATV kW V - 3 phase - compact

ATV320D11N4B variable speed drive ATV320-11kW V - 3 phase - book

ATV320D15N4B variable speed drive ATV320-15kW V - 3 phase - book

ATV320D15N4B variable speed drive ATV320-15kW V - 3 phase - book

ATV320U07M2C variable speed drive ATV kW V - 1 phase - compact

ATV320U30N4B variable speed drive ATV320-3kW V - 3 phase - book

ATV320U11N4C. Product datasheet Characteristics. Main. Complementary 1 / 7. Device short name Format of the drive

ATV320U04N4C variable speed drive ATV kW V - 3 phase - compact

ATV320U22M2C. Product datasheet Characteristics. Main. Complementary 1 / 7. Device short name Format of the drive

ATV320D11N4B. Product datasheet Characteristics. Main. Complementary 1 / 8. Device short name Format of the drive

ATV320D15M3C variable speed drive ATV320-15kW - 200V - 3phase - compact

ATV320U06N4C variable speed drive ATV kW V - 3 phase - compact

ATV32HD11N4 variable speed drive ATV32-11 kw V - 3 phase - with heat sink

ATV32HD11N4 variable speed drive ATV32-11 kw V - 3 phase - with heat sink

ATV32HU11M2437 variable speed drive ATV32-1.1kW 200V - 1P - Bluetooth built-in - w heat sink

ATV32H055N4 variable speed drive ATV kw V - 3 phase - with heat sink

ATV32HU75N4 variable speed drive ATV kw V - 3 phase - with heat sink

ATV32HU30N4 variable speed drive ATV32-3 kw V - 3 phase - with heat sink

ATV32HU30N4 variable speed drive ATV32-3 kw V - 3 phase

ATV32H075M2 variable speed drive ATV32-0,75 kw V - 1 phase - with heat sink

ATV32HU40N4 variable speed drive ATV32-4 kw V - 3 phase - with heat sink

ATV32H018M2 variable speed drive ATV32-0,18 kw V - 1 phase - with heat sink

ATV930U30M3 variable speed drive - ATV930-3kW - 200/240Vwith braking unit - IP21

ATV32HU30N4 variable speed drive ATV32-3 kw V - 3 phase - with heat sink

ATV12H075M3 variable speed drive ATV kW - 1hp V - 3ph - with heat sink

ATV12P037F1 variable speed drive ATV kW hp V - 1ph - on base plate

ATV12H018M2 variable speed drive ATV kW hp V - 1ph

ATV310HU30N4E variable speed drive ATV310-3 kw - 4 hp V - 3 phase

ATV930D22M3 variable speed drive - ATV930-22kW - 200/240V- with braking unit - IP21

ATV650U30N4E variable speed drive ATV650-3kW V - IP55 - disconnect switch

ATV61HC31Y variable speed drive ATV61-310kW - 690V - without EMC filter

ATV630U15N4 variable speed drive ATV kW/2HP V - IP21/UL type 1

ATV340D75N4E variable speed drive - 75kW- 400V - 3 phases - ATV340 Ethernet

ATV12P075M3 variable speed drive ATV kW - 1hp V - 3ph - on base plate

ATV12HU22M3 variable speed drive ATV12-2.2kW - 3hp V - 3ph - with heat sink

ATV340D18N4E variable speed drive - 18kW- 400V - 3 phases - ATV340 Ethernet

ATV630D11N4 variable speed drive ATV630-11kW/15HP V - IP21/UL type 1

ATV61HC11N4 SPEED DRIVE 150 HP 460 V ATV61

ATV310H075N4E variable speed drive ATV kw - 1 hp V - 3 phase

ATV630D90N4 variable speed drive ATV630-90kW/125HP V - IP21/UL type 1

ATV61HU55M3 ATV61 5,5 kw 7,5HP 240V single phase EMC IP20

ATV71QC16N4 variable speed drive ATV71Q - 160kW / 250HP V - IP20

ATV630D15N4 variable speed drive ATV630-15kW/20HP V - IP21/UL type 1

ATV650D22N4 variable speed drive ATV650-22kW/30HP V - IP55

ATV930U07M3 variable speed drive - ATV930-0,75kW - 200/240V- with braking unit - IP21

ATV930U55N4 variable speed drive - ATV930-5,5kW - 400/480V - with braking unit - IP21

ATV930D45N4 variable speed drive - ATV930-45kW - 400/480V - with braking unit - IP21

ATV71EXA2C71N4 enclosed variable speed drive ATV71 Plus kw - 400V - IP23

ATV61HC31N4 variable speed drive ATV61-315kW 500HP - 500V - EMC filter - IP20

ATV61QC31N4 variable speed drive ATV61Q - 315kW / 500HP V - IP20

ATV660C16Q4X1 Compact Drive System ATV /132kW V - IP23

ATV340U15N4 variable speed drive - 1.5kW- 400V - 3 phases - ATV340

ATV630U55N4 variable speed drive ATV kW/7.5HP V - IP21/UL type 1

ATV930C11N4C variable speed drive - ATV kW - 400/480V - w/o braking unit - IP00

ATV630U15N4 variable speed drive ATV kW/2HP V - IP21/UL type 1

ATV212WD30N4 variable speed drive ATV212-30kW - 40hp - 480V - 3ph - EMC class C2 - IP55

ATV61HC22N4 Altivar 61 drive 350hp 400/480 3ph

ATV212WU55N4 variable speed drive ATV kW - 7.5hp - 480V - 3ph - EMC class C2 - IP55

ATV630D30N4 variable speed drive ATV630-30kW/40HP V - IP21/UL type 1

ATV930U75N4 variable speed drive - ATV930-7,5kW - 400/480V - with braking unit - IP21

ATV212WU40N4 variable speed drive ATV212-4kW - 5hp - 480V - 3ph - EMC class C2 - IP55

ATV680C45Q4X1 Low Harmonic Drive System ATV /355kW V - IP23

ATV212HD15N4 variable speed drive ATV212-15kW - 20hp - 480V - 3ph - EMC - IP21

ATS22D17Q soft starter-ats22-control 220V-power 230V (4kW)/ V(7.5kW)

ATV212HD75N4. Main. Range of product Altivar 212. Device short name. Motor power hp 160 A 460 V khz with derating factor

ATV212HD18N4 variable speed drive ATV kW - 25hp - 480V - 3ph - EMC - IP21

ATV212HD15N4 variable speed drive ATV212-15kW - 20hp - 480V - 3ph - EMC - IP21

ATV630C22N4 variable speed drive ATV kW/350HP V - IP00

ATV212HD11N4 variable speed drive ATV212-11kW - 15hp - 480V - 3ph - EMC - IP21

ATV212HU15N4. Main. Range of product Altivar 212. Device short name 3.7 A 460 V khz adjustable

ATV630U40M3 variable speed drive ATV630-4kW/5HP V - IP21/UL type 1

ATV650C13N4F. ATV650C13N4F variable speed drive ATV kW V - IP54 - disconnect switch. Product data sheet Characteristics.

ATV650C16N4F variable speed drive ATV kW V - IP54 - disconnect switch

ATV61HD11Y variable speed drive ATV61-11kW / 690V - 10HP / 575V - IP20

ATV212HD30N4 variable speed drive ATV212-30kW - 40hp - 480V - 3ph - EMC - IP21

ATV630D45N4 variable speed drive ATV630-45kW/60HP V - IP21/UL type 1

ATV630U07M3 variable speed drive ATV kW/1HP V - IP21/UL type 1

ATV212HU55N4 variable speed drive ATV kW - 7.5hp - 480V - 3ph - EMC - IP21

ATV212HU55N4 variable speed drive ATV kW - 7.5hp - 480V - 3ph - EMC - IP21

ATV630D90N4 variable speed drive ATV630-90kW/125HP V - IP21/UL type 1

ATV630D55M3 variable speed drive ATV630-55kW/75HP V - IP00

ATV630D11M3 variable speed drive ATV630-11kW/15HP V - IP21/UL type 1

ATS22D75S6U. Main. Range of product Altistart 22. Component name. Factory setting current. Utilisation category. IP degree of protection

ATS22D17Q soft starter-ats22-control 220V-power 230V(4kW)/ V(7.5kW)

ATSU01N209LT soft starter for asynchronous motor - ATSU01-9 A V KW

ATS22C17Q. Main. Range of product Altistart 22. Component name. Factory setting current. Utilisation category. IP degree of protection

ATS22D47S6U. Main. Range of product Altistart 22. Component name. Factory setting current. Utilisation category. IP degree of protection

ATS01N232RT soft starter for asynchronous motor - ATS01-32 A V

ATV32HD11N4 variable speed drive ATV32-11 kw V - 3 phase - with heat sink

ATS22C11S6U soft starter-ats22-control110vpower208v(30hp)/230v(40hp)/460v(75hp)/575v(100h

ATV212HD11M3X variable speed drive ATV212-11kW - 15hp - 240V - 3ph -wo EMC - IP21

ATV32HU15N4 variable speed drive ATV kw V - 3 phase - with heat sink

ATV630U55N4 variable speed drive ATV kW/7.5HP V - IP21/UL type 1

ATV32H037N4 variable speed drive ATV kw V - 3 phase - with heat sink

ATS22D75Q soft starter-ats22-control 220V-power 230V(18.5kW)/ V(37kW)

LXM32AD18N4 motion servo drive - Lexium 32 - three-phase supply voltage 208/480V kw

ATV212HU75N4 variable speed drive ATV kW - 10hp - 480V - 3ph - EMC - IP21

600 hp at V 3 phases. 568 A for 480 V 3 phases 400 kw / 600 hp 637 A for 380 V 3 phases 355 kw 709 A for 380 V 3 phases 400 kw / 600 hp

ATV71HC31N4 variable speed drive ATV71-315kW-500HP - 480V - EMC filter-graphic terminal

Transcription:

Product datasheet Characteristics ATV320U15N4C Complementary Main Range of product Product or component type Product specific application Device short name Format of the drive Product destination EMC filter Altivar Machine ATV320 Variable speed drive Complex machines ATV320 Compact Asynchronous motors Synchronous motors Class C2 EMC filter integrated IP degree of protection IP20 conforming to EN/IEC 61800-5-1 Degree of protection Type of cooling Phase UL type 1 with UL type 1 conformity kit Fan 3 phases [Us] rated supply voltage 380...500 V (- 15...10 %) Supply frequency 50...60 Hz (- 5...5 %) Motor power kw Motor power hp Line current Prospective line Isc Apparent power Continuous output current Maximum transient current Asynchronous motor control profile 1.5 kw heavy duty 2 hp heavy duty 6.4 A at 380 V heavy duty 4.9 A at 500 V heavy duty 5 ka 4.2 kva at 500 V heavy duty 4.1 A at 4 khz heavy duty 6.2 A during 60 s heavy duty Voltage/frequency ratio, 2 points Voltage/frequency ratio, 5 points Flux vector control without sensor, standard Voltage/frequency ratio - Energy Saving, quadratic U/f Flux vector control without sensor - Energy Saving Synchronous motor control profilevector control without sensor Speed drive output frequency Nominal switching frequency Switching frequency 0.1...599 Hz 4 khz 2...16 khz adjustable 4...16 khz with current derating Safety function STO (safe torque off) SIL 3 SS1 (safe stop 1) SMS (safe maximum speed) SLS (safe limited speed) GDL (guard door locking) Communication port protocol Option card CANopen Modbus Communication module: CANopen daisy chain RJ45 Communication module: CANopen SUB-D 9 Communication module: CANopen open style terminal block Communication module: EtherCAT RJ45 Communication module: DeviceNet Communication module: Ethernet/IP Communication module: Profibus DP V1 Communication module: Profinet Communication module: Ethernet Powerlink 1 / 7 The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein. This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications. It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof. Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein.

Variant Output voltage Permissible temporary current boost Speed range Speed accuracy Torque accuracy +/- 15 % Transient overtorque Braking torque Regulation loop Motor slip compensation Acceleration and deceleration ramps Braking to standstill Protection type Frequency resolution Standard version <= power supply voltage 1.5 x In during 60 s heavy duty 1...100 with asynchronous motor in open-loop mode +/- 10 % of nominal slip 0.2 Tn to Tn 170...200 % of nominal motor torque <= 170 % with braking resistor during 60 s Adjustable PID regulator Automatic whatever the load Not available in voltage/frequency ratio (2 or 5 points) Adjustable 0...300 % S U CUS Deceleration ramp automatic stop DC injection Deceleration ramp adaptation Linear Ramp switching By DC injection Drive: thermal protection Drive: overcurrent between output phases and earth Drive: input phase breaks Drive: overheating protection Drive: short-circuit between motor phases Display unit: 0.1 Hz Analog input: 0.012/50 Hz Electrical connection Control, screw terminal: 0.5...1.5 mm² AWG 20...AWG 16 Motor/braking resistor, screw terminal: 2.5...6 mm² AWG 14...AWG 10 Power supply, screw terminal: 2.5...6 mm² AWG 14...AWG 10 Connector type Physical interface Transmission frame Transmission rate Data format Type of polarization Number of addresses Method of access 1 RJ45 Modbus/CANopen on control terminal 2-wire RS 485 Modbus RTU Modbus 4.8, 9.6, 19.2, 38.4 kbit/s Modbus 50 kbps, 125 kbps, 250 kbps, 500 kbps, 1 Mbps CANopen 8 bits, configurable odd, even or no parity Modbus No impedance Modbus 1...247 Modbus 1...127 CANopen Slave CANopen Supply Internal supply for reference potentiometer (1 to 10 kohm): 10.5 V DC (+/- 5 %) current <= 10 ma (overload and short-circuit protection) Local signalling Width Height Depth Product weight Analogue input number 3 Analogue input type Discrete input number 7 Discrete input type 1 LED green CANopen run 1 LED red CANopen error 1 LED red drive fault 4.13 in (105 mm) 142 mm 188 mm with EMC plate 6.22 in (158 mm) 2.87 lb(us) (1.3 kg) Voltage (AI1): 0...10 V DC, impedance 30000 Ohm, resolution 10 bits Bipolar differential voltage (AI2): +/- 10 V DC, impedance 30000 Ohm, resolution 10 bits Current (AI3): 0...20 ma (or 4-20 ma, x-20 ma, 20-x ma or other patterns by configuration), impedance 250 Ohm, resolution 10 bits Programmable (sink/source) (DI1...DI4): 24...30 V DC: level 1 PLC Programmable as pulse input 20 kpps (DI5): 24...30 V DC: level 1 PLC Switch-configurable PTC probe (DI6): 24...30 V DC Safe torque off (STO): 24...30 V DC, impedance 1500 Ohm Discrete input logic Negative logic (sink): : DI1...DI6, > 19 V (state 0) < 13 V (state 1) Positive logic (source): : DI1...DI6, < 5 V (state 0) > 11 V (state 1) Analogue output number 1 2 / 7

Analogue output type Software-configurable current (AQ1): 0...20 ma, impedance 800 Ohm, resolution 10 bits Software-configurable voltage (AQ1): 0...10 V, impedance 470 Ohm, resolution 10 bits Sampling duration Analog input (AI1, AI2, AI3): 2 ms Analog output (AQ1): 2 ms Accuracy Analog input AI1, AI2, AI3: +/- 0.2 % for a temperature of -10...60 C Analog input AI1, AI2, AI3: +/- 0.5 % for a temperature of 25 C Analog output AQ1: +/- 1 % for a temperature of 25 C Analog output AQ1: +/- 2 % for a temperature of -10...60 C Linearity error Discrete output number 3 Discrete output type Refresh time Minimum switching current Maximum switching current Specific application Discrete and process manufacturing Power range Motor starter type Analog input (AI1, AI2, AI3): +/- 0.2...0.5 % of maximum value Analog output (AQ1): +/- 0.3 % Configurable relay logic NO/NC (R1A, R1B, R1C): electrical durability 100000 cycles Configurable relay logic NO (R2A, R2B): electrical durability 100000 cycles Logic (LO) Logic input (DI1...DI6): 8 ms (+/- 0.7 ms) Relay output (R1A, R1B, R1C): 2 ms Relay output (R2A, R2C): 2 ms Relay output (R1, R2): 5 ma at 24 V DC Relay output (R1) on resistive load (cos phi = 1: 3 A at 250 V AC Relay output (R1) on resistive load (cos phi = 1: 4 A at 30 V DC Relay output (R1, R2) on inductive load (cos phi = 0.4: 2 A at 250 V AC Relay output (R1, R2) on inductive load (cos phi = 0.4: 2 A at 30 V DC Relay output (R2) on resistive load (cos phi = 1: 5 A at 250 V AC Relay output (R2) on resistive load (cos phi = 1: 5 A at 30 V DC Machinery Hoisting self erecting Material handling carousel Material handling conveyor Material handling lifting platfrom Material handling palletizers - medium performance Material handling transfer table Material handling turn table Material working (wood, ceramic, stone, pvc, metal) cutting - medium accuracy Material working (wood, ceramic, stone, pvc, metal) drilling Material working (wood, ceramic, stone, pvc, metal) saw Packaging bagging Packaging feed conveyor low performance Packaging filling bottles - intermittent operation Packaging linear labeling Packaging other application Packaging stretching wrapping Packaging tray take Textile knitting Textile printing machines Textile spinning Washing machines car Washing machines other application Hoisting standard crane - travelling or trolley 1.1...2 kw 380...440 V 3 phases 1.1...2 kw 480...500 V 3 phases Variable speed drive Environment isolation insulation resistance noise level power dissipation in W volume of cooling air operating position Between power and control terminals > 1 mohm at 500 V DC for 1 minute to earth 51 db conforming to 86/188/EEC 61 W (fan) at 380 V, 4 khz 4755.18 Gal/hr(US) (18 m3/h) Vertical +/- 10 degree electromagnetic compatibility Conducted radio-frequency immunity test conforming to IEC 61000-4-6 level 3 Electrical fast transient/burst immunity test conforming to IEC 61000-4-4 level 4 Electrostatic discharge immunity test conforming to IEC 61000-4-2 level 3 Radiated radio-frequency electromagnetic field immunity test conforming to IEC 61000-4-3 level 3 Voltage dips and interruptions immunity test conforming to IEC 61000-4-11 1.2/50 µs - 8/20 µs surge immunity test conforming to IEC 61000-4-5 level 3 pollution degree 2 conforming to EN/IEC 61800-5-1 3 / 7

vibration resistance 1 gn (f = 13...200 Hz) conforming to EN/IEC 60068-2-6 1.5 mm peak to peak (f = 2...13 Hz) conforming to EN/IEC 60068-2-6 shock resistance 15 gn during 11 ms conforming to EN/IEC 60068-2-27 relative humidity 5...95 % without condensation conforming to IEC 60068-2-3 5...95 % without dripping water conforming to IEC 60068-2-3 ambient air temperature for operation ambient air temperature for storage operating altitude 14...122 F (-10...50 C) without derating 122...140 F (50...60 C) with derating factor -13...158 F (-25...70 C) <= 3280.84 ft (1000 m) without derating 3280.84...9842.52 ft (1000...3000 m) with current derating 1 % per 100 m standards EN/IEC 61800-3 EN/IEC 61800-3 environment 1 category C2 EN/IEC 61800-5-1 IEC 60721-3 IEC 61508 IEC 13849-1 product certifications marking CSA NOM 117 UL RCM EAC CE Offer Sustainability Green Premium product Compliant - since 1610 - Schneider Electric declaration of conformity Reference not containing SVHC above the threshold Green Premium product Compliant - since 1610 - Schneider Electric declaration of conformity Reference not containing SVHC above the threshold Dimensions (1) Right view (2) Front view (3) Front view with EMC plate Mounting Types Mounting Type A: Individual with Ventilation Cover Only Possible at Ambient Temperature Less or Equal to 50 C (122 F) Mounting Type B: Side by Side, Ventilation Cover Removed 4 / 7

Mounting Type C: Individual, Ventilation Cover Removed For Operation at Ambient Temperature Above 50 C (122 F) Connection Diagrams Diagram with Line Contactor Connection diagrams conforming to standards EN 954-1 category 1 and IEC/EN 61508 capacity SIL1, stopping category 0 in accordance with standard IEC/EN 60204-1. (1) Line choke (if used) (2) Fault relay contacts, for remote signaling of drive status Diagram with Switch Disconnect Connection diagrams conforming to standards EN 954-1 category 1 and IEC/EN 61508 capacity SIL1, stopping category 0 in accordance with standard IEC/EN 60204-1. (1) Line choke (if used) (2) Fault relay contacts, for remote signaling of drive status 5 / 7

Control Connection Diagram in Source Mode (1) Analog output (2) Analog inputs (3) Reference potentiometer (10 kohm maxi) (4) Digital inputs Digital Inputs Wiring The logic input switch (SW1) is used to adapt the operation of the logic inputs to the technology of the programmable controller outputs. Switch SW1 set to Source position and use of the output power supply for the DIs. Switch SW1 set to Source position and use of an external power supply for the DIs. Switch SW1 set to Sink Int position and use of the output power supply for the DIs. Switch SW1 set to Sink Ext position and use of an external power supply for the DIs. 6 / 7

Derating Curves 40 C (104 F) - Mounting type A, B and C 50 C (122 F) - Mounting type A, B and C 60 C (140 F) - Mounting type B and C In : Nominal Drive Current SF : Switching Frequency Our Proposal: Circuit Breaker + Contactor + Drive for 1,5 kw and 380 VAC (kw) Icu (ka) Breaker Contactor (*) Motor Starter 1,5 > 100 GV2L14 LC1D09P7 ATV320U15N4C Non contractual pictures. (*) You can select the contactor proposed or variants. Please consider examples hereafter or follow the link to the complete offer. kw Coil voltage VAC - 50/60 Hz 24 48 110 115 220 230 400 Other 1,5 LC1D09.. B7 E7 F7 FE7 M7 P7 V7 Complete Offer kw Coil voltage VDC 24 48 110 125 220 230 Other 1,5 LC1D09.. BD ED - - - - Complete Offer kw Coil voltage Low Consumption VDC - U 0.8 1.25 Uc 24 110 Other 1,5 LC1D09.. BL FL Complete Offer 7 / 7