Click on Series name for product info on aimtec.com Models Single output Model Input Voltage (VAC/Hz) FEATURES: I/O Isolation VAC Continuous Short circuit protection Input under-voltage protection Low no load consumption.w Input: 9-VAC/7-Hz, or -7VDC Efficiency up to 8% Over current, Over Voltage Protection Output Voltage adjustment Input Voltage (VDC) Output Voltage (V) Output Current max (A) Maximum capacitive Load (µf) Efficiency VAC (%) AME-SMJZ 9-/7- -7, 8 AME-9SMJZ 9-/7- -7 9. 8, 8 AME-SMJZ 9-/7- -7, 8 AME-SMJZ 9-/7- -7, 8 AME-SMJZ 9-/7- -7. 8 AME-8SMJZ 9-/7- -7 8. 8 Note: Add suffix -ST for optional screw terminal bottom plate or -STD for optional DIN Rail screw terminal bottom plate. Input Specifications Current (full load) VAC. A VAC.7 A Inrush current <ms (cold start) VAC A VAC A Under voltage protection Shutdown 7 VAC VDC Output Specifications Voltage accuracy Full load ± % Line regulation LL-HL, Full Load ±. % Load regulation -% load ± % Ripple & Noise MHz bandwidth mv p-p VAC ms Hold-up time VAC ms Voltage adjustment range Single output only ± % of Vout Isolation Specifications Parameters Conditions Typical Rated Units Tested I/O voltage sec VAC Isolation voltage Input to Ground sec VAC Isolation voltage Output to Ground sec VAC General Specifications Switching frequency % load KHz Protection class Class I Over current protection % of Iout Over voltage protection Zener diode clamp Short circuit protection Continuous, Auto recovery Operating temperature See derating curve - to +7 o C Storage temperature - to +8 o C Maximum Case temperature o C Temperature coefficient ±. % / o C Cooling Free air convection F e R8.C of 7 North America only
. (.). (.). (.8). (.).7 (.). (.) 9. (.7).8 (.) 8.9 (.) General Specifications (continued) Humidity Non condensing 9 % RH Case material Plastic (flammability to UL 9V-) Weight PCB mountable models With optional -ST mounting plate: With optional -STD mounting plate: 7 g Dimensions (L x W x H) PCB mountable models With optional -ST mounting plate: With optional -STD mounting plate:.9 x. x.8 inches (9. x 8. x.mm). x.7 x. inches (. x 7. x 8. mm).9 x.7 x.78 inches (7. x 7. x. mm) MTBF >, hrs (MIL-HDBK -7F, t=+ o C)/Full Load NOTE: All specifications in this datasheet are measured at an ambient temperature of C, humidity<7%, nominal input voltage and at rated output load unless otherwise specified. Safety Specifications Parameters Agency approvals Standards Dimensions culus, CE Information technology Equipment IEC/EN/UL 9- EMI - Conducted and radiated emission EN, class B Electrostatic Discharge Immunity IEC -- Level RF, Electromagnetic Field Immunity IEC -- Level Electrical Fast Transient/Burst Immunity IEC -- Level Surge Immunity IEC -- Level RF, Conducted Disturbance Immunity IEC -- Level Power frequency Magnetic Field Immunity IEC --8 Level Voltage dips, Short Interruptions Immunity IEC -- Class 9. (.9) 97. (.8) 8.. (.) (.8) Ø. (.) Ø. (.7) BOTTOM VIEW Ø. (Ø.9) Ø. (Ø.9) TOP VIEW xm.(.) 9. (.79) Ø.7 (Ø.7) Ø. (Ø.9) Ø. (Ø.9). (.8) Ø.7 (Ø.7) Ø. (Ø.) DIV:.8 (.) Pin Out Specifications Pin Single AC Input (N) AC Input (L) Ground +V Output -V Output Trim xm.(.) ᴓ.(.8) Dimensions: mm (inch) Case Tolerance: ±. (.) Pin Tolerance: ±. (.) Pin diameter Tolerance: ±. (.) Pin,, & diameter:. (.7) Pin & diameter:. (.7) F e R8.C of 7 North America only
8. (.). (.8) 8. (.) 7. (.7). (.) With optional -ST bottom plate. (.). (.7) Ø. (.) Top view 7 8 Dimensions: mm (inch) Case Tolerance: ±. (.) Holding holes tolerance: ±. (.) Wire gauge: -AWG Side view F e R8.C of 7 North America only
Output Power (%) Output Power (%). (.8) 8. (.). (.8) 9. (.) 7. (.7). (.) With optional -STD bottom plate. (.). (.7) Top view 7 8 Dimensions: mm (inch) General Tolerance: ±. (.) Holding holes tolerance: ±. (.) Wire gauge: -AWG DIN rail type: TS 7. (.9) Side view Deratings AME-SMJZ & AME-SMJZ Free Air Convection AME-SMJZ & AME-SMJZ Free Air Convection % load -VAC -7VDC % load -VAC -7VDC - - - 7 Ambient Temperature º C - - - 7 Ambient Temperature º C F e R8.C of 7 North America only
Output Power (%) Output Power (%) AME-SMJZ & AME-8SMJZ Free Air Convection Free Air Convection at C % load -VAC -7VDC - - - 7 Ambient Temperature º C 9 () () Input Voltage VAC (VDC) (7) Typical application circuits AC L FUSE.A/V NTC AC L Single Output + Vout + Vout AC N MOV SK AC AC N DC C µf/v C + TVS Earth/GND - Vout - Vout Model C TVS Single Vout µf 7V Single 9 Vout 7 µf V Single & Vout µf V Single Vout µf V Single 8 Vout µf V Trimming Output voltage can be externally trimmed by utilizing the methods as shown below F e R8.C of 7 North America only
Fixed Resistor Variable Potentiometer Leave open if not used. AME-SMJZ Vout (VDC).9.9.8.8.7.7.... Rt down (KΩ).7 78..7.9 8.7. 9.7... Vout (VDC).......... Rt up (KΩ) 8....7 9. 7.. AME-9SMJZ Vout (VDC) 8.9 8.8 8.7 8. 8. 8. 8.7 8.8 8.9 8. Rt down (KΩ).79.9 97. 7.9 8. 8..9.9.9 7.9 Vout (VDC) 9.9 9.8 9.7 9. 9. 9. 9. 9.7 9.8 9.9 Rt up (KΩ) 87.89 7.9 7.9.8.89.99 8..97..7 AME-SMJZ Vout (VDC).88.7....8...9.8 Rt down (KΩ) 8..9 79.7. 9.99.99.9..9.9 Vout (VDC)....8..7.8.9.8. Rt up (KΩ).778 7..9. 7.8.8. 9.89 8.7 7. AME-SMJZ Vout (VDC).8.7.....9.8.. Rt down (KΩ). 99.8 7.7. 9.7.78 9..9 Vout (VDC).....7.9.... F e R8.C of 7 North America only
Rt up (KΩ)..7. 9.8.87..889. AME-SMJZ Vout (VDC).7..8..8...8.8. Rt down (KΩ) 7.8 87.9.8 9.9 9. 8.8 9.79.9 7..8 Vout (VDC)..8.7.9...8.9.. Rt up (KΩ) 9...98.78 9.9.78.. 9.77 8. AME-8SMJZ Vout (VDC) 7. 7...8.....8. Rt down (KΩ) 8..9 88.9 7.8 9..9 7. 8. 9.. Vout (VDC) 8.8 8.9 9. 9.9..88..8..8 Rt up (KΩ)..9 7.8.99 8.99.9.8.7 9.9 7.7 NOTE:. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications.. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured.. Mechanical drawings and specifications are for reference only.. All specifications are measured at an ambient temperature of C, humidity<7%, nominal input voltage and at rated output load unless otherwise specified.. Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release.. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec s standard Terms of Sale available at www.aimtec.com. F e R8.C 7 of 7 North America only