Second Stakeholder Meeting for Nonresidential HVAC Proposals Based on ASHRAE Revisions to Waterside Economizer

Similar documents
Economizer Fault Detection and Diagnostics (FDD) for Built-Up Air Handlers Draft Report

Nonresidential HVAC Stakeholder Meeting #3

New Wisconsin Energy Code: What it Means for Me?

Data Center Energy Savings By the numbers

DATA CENTER EFFICIENCY: Data Center Temperature Set-point Impact on Cooling Efficiency

Is Data Center Free Cooling Feasible in the Middle East? By Noriel Ong, ASEAN Eng., PMP, ATD, PQP

2013 Building Energy Efficiency Standards Staff Workshop

How Green can you go?

Future of Cooling High Density Equipment. Steve Madara Vice President and General Manager Liebert Precision Cooling Business Emerson Network Power

Mission Critical Facilities & Technology Conference November 3, 2011 Cooling 101. Nick Gangemi Regional Sales Manager Data Aire

What s New for Data Centers in Title Jeff Stein, PE Taylor Engineering

Reducing Data Center Cooling Costs through Airflow Containment

Retro-Commissioning Report

Digital Realty Data Center Solutions Digital Chicago Datacampus Franklin Park, Illinois Owner: Digital Realty Trust Engineer of Record: ESD Architect

What s on the Horizon for HVAC in Title ? Mark Hydeman, PE, Principal Taylor Engineering, LLC

LIFE CYCLE COST ANALYSIS, CRITERIA AND DATA SHEETS DOCUMENT NUMBER: APPLICATION: ELEMENTARY, MIDDLE AND HIGH SCHOOL

Passive RDHx as a Cost Effective Alternative to CRAH Air Cooling. Jeremiah Stikeleather Applications Engineer

2013 Building Energy Efficiency Standards Non-Residential HVAC Alterations

Metering and Energy Retrofits for the GSA

Trailblazer AGZ-E air-cooled scroll chillers

2017 NEHES Fall Conference Technical Breakout Session: Deep Chiller Plant Optimization

glide glider kw R134a air cooled liquid chillers AND free cooling chillers FREE COOLING SHELL A C CLASS E C Energy Class RCGROUP SpA

How to Get the Most out of Your Rooftop AC

Designing Ultra-Efficient Building Cooling Systems

Silicon Valley Power Data Center Program Rebate Application

DEDICATED HEAT RECOVERY UNIT (DHRC)

Achieving Operational Excellence

MSYS 4480 AC Systems Winter 2015

Introducing the Heat Wheel to the Data Center

Thank you for joining today s webinar: Advancing DR Automation and Standards in Building Codes (CA Title 24)

IBM - Energy Efficiency Recommissioning: Improving Buildings Systems Efficiency Jean-Pierre Boulianne, Pierre Lefèbvre, Yves Veilleux ICEBO 2013

Trane Engineering News Chiller Plant Case Study: Variable-Primary Flow Series Chillers with Free Cooling

ASHRAE Standard 90.1

Aquaflair. BREC/F and BCEC/F kw

WHAT IS THE DIGI-RTU South 59 th Street Omaha, NE bes-tech.net

Your Solution For Energy and Cost Savings. McQuay Packaged Chiller Plant

DEEMED SAVINGS TECHNICAL ASSUMPTIONS

DUKE UNIVERSITY DESIGN & CONSTRUCTION STANDARDS

Critical Facilities Existing Building Commissioning (EBCx)

E e n rgy g y St S ud u y y Pr P og o r g ams December 2011

A Data Center Heat Removal System That Saves... 80% Discover Inertech s Award-winning Data Center Heat Removal System

Energy Engineering: Tools and Trends

STATE DATA CENTER DRAFT PROPOSAL. STATE OF OREGON DATA CENTER 28 October 2016

Planning for Liquid Cooling Patrick McGinn Product Manager, Rack DCLC

Air-Side Economizer Cycles Applied to the Rejection of Data Center Heat

Prescriptive Program Rebate Application

Identify the Right Applications

Impact of Air Containment Systems

Green IT and Green DC

Waterside Economizing in Data Centers: Design and Control Considerations

Chiller Replacement and System Strategy. Colin Berry Account Manager

HVAC System Energy Savings Opportunities

IN-DEPTH UNDERSTANDING OF HVAC EQUIPMENT & SYSTEM SPECIFICATIONS AND PERFORMANCE 11 & 12 JULY 2016 WISMA IEM

Specification and Design Catalog. Waterside Economizer

Notes from 2019 Title 24 Part 6 Code Development Cycle Utility-Sponsored Stakeholder Meeting for Nonresidential HVAC

AisleLok Modular Containment vs. Legacy Containment: A Comparative CFD Study of IT Inlet Temperatures and Fan Energy Savings

Saving Water and Operating Costs at NREL s HPC Data Center

CenterPoint Energy Retro-Commissioning Program Application

Contents. Rev. 2, 5/12/2016 1

Initial Review of ASHRAE/ANSI/ACCA Standard 180 (2010)

Committed to Energy Efficiency

Commercial HVAC and Other Measures for 7P. Outline

Efficiency of Data Center cooling

where we are, where we could be, how we can get there. 12/14/2011

PROCESS COOLING STUDY WORKSHEET

Building Re-Tuning (BRT) Lesson 4: SOI Air-Handling Unit Part II

Airside Economizer Comparing Different Control Strategies and Common Misconceptions

HIGH EFFICIENCY Central Chiller

Effect of the Certification on Chillers Energy Efficiency

INSTALLATION INSTRUCTIONS ECOHPRS Series Horizontal Economizer for York PRESTIGE for ZX 04-07; ZY 04-06

Hot vs Cold Energy Efficient Data Centers. - SVLG Data Center Center Efficiency Summit

NEW FEATURES IN CARRIER BUILDING SYSTEM OPTIMIZER 1.40

7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America

CHAPTER/REGIONAL TECHNOLOGY AWARD - SHORT FORM

Data Center Temperature Design Tutorial. Ian Seaton Chatsworth Products

Continuous Commissioning at Sandia National Laboratories

HOURLY ANALYSIS PROGRAM v5.00 and v5.01

Optimiz Chilled January 25, 2013

Warning. Important. Always follow all local building electrical codes. PECCSUN3672DB46M PECCSUN3672EN46M

Liebert Economizer Cooling Solutions Reduce Cooling Costs by up to 50% Without Compromising Reliability

UC DAVIS THERMAL ENERGY STORAGE (TES) TANK OPTIMIZATION INVESTIGATION MATTHEW KALLERUD, DANNY NIP, MIANFENG ZHANG TTP289A JUNE 2012

Cleanroom Energy Benchmarking In High-Tech and Biotech Industries

REPORT. Energy Efficiency of the San Diego Supercomputer Center and Distributed Data Centers at UCSD. Prepared for:

WHAT IS THE DIGI-RTU South 59 th Street Omaha, NE bes-tech.net

Efficiency Works Business: 2017 Rebates & Goals. January 17, 2017

Presentation. Guaranteed Energy Savings Performance Project

IT COOLING EVAPORATIVE COOLING SYSTEM. 2 STAGE INDIRECT ADIABATIC COOLING SYSTEM FOR LARGE DATA CENTERS FROM 80 TO 320 kw

Airside Economizer Comparing Different Control Strategies and Common Misconceptions

Chillventa Specialist Forums 2018 Chillventa Fachforen 2018

Welcome Association of Energy Engineers to the Microsoft Technology Center

Reducing Energy Consumption with

System Overview. Liquid Cooling for Data Centers. Negative Pressure Cooling Without Risk of Leaks

ASHRAE CHAPTER TECHNOLOGY AWARD Illinois Chapter, Region VI

Measurement and Management Technologies (MMT)

Chiller Plant Optimization: A Case Study

Schneider Electric Cooling Portfolio. Jim Tubbesing Heath Wilson APC/Schneider North Texas Rep Tubbesing Solutions

Water cooled chiller plant (all-variable)

Reclaim Wasted Cooling Capacity Now Updated with CFD Models to Support ASHRAE Case Study Data

Case study: Energy efficiency improvements in a legacy data centre. Robert Tozer Director Opera>onal Intelligence

VARIABLE REFRIGERANT FLOW SYSTEMS HITACHI SMARTFLEX VRF GEN II FLEXIBILITY, PERFORMANCE AND CONTROL

Transcription:

Second Stakeholder Meeting for Nonresidential HVAC Proposals Based on ASHRAE 90.1-2016 Revisions to Waterside Economizer March 15, 2017 Stefan Gracik 510-663-2070 sgracik@integralgroup.com

Agenda 1. Background 2. Proposed Code Changes 3. Technical and Market Barriers 4. Compliance and Enforcement 5. Cost-Effectiveness and Energy Impacts 6. Next Steps 2

1. Background 3

Introduction to Technology / Building System How much can a cooling tower cool the air? 4

Introduction to Technology / Building System Wet-bulb temperature represents minimum temperature possible by evaporative cooling Wet-bulb varies with humidity An infinitely large tower could cool water all the way to a wet-bulb, however this is not practical for buildings. We can get close How close we get is called the approach: Approach = T CoolingTowerOutlet T wet-bulb 5

Introduction to Technology / Building System When wet-bulb is low enough 6

Introduction to Technology / Building System When wet-bulb is low enough Bypass Chiller Non-Integrated Waterside Economizer Cooling towers with lower approaches can run in this mode for more hours HX 7

Introduction to Technology / Building System When wet-bulb is low enough Or Pre-cool chilled water with cooling tower water Allows chiller to use less energy When wet-bulb is low enough Integrated Waterside Economizer Cooling towers with lower approaches can run in this mode for more hours HX HX 8

Relevant Code History There are requirements in Title 24, Part 6, based on ASHRAE 90.1 Cooling Air Handler s over 54,000 Btu/hr shall include either an air or water economizer Water economizer must meet full cooling load at 45 F wet-bulb and 50 F dry-bulb Other Relevant Code Requirements ASHRAE 90.1 2016 updated waterside economizer requirements to be more stringent Require water economizers on passive without fan systems as well Limit pressure drop of Heat exchangers Require cooling towers to operate efficiently when not economizing Require system to use Integrated Waterside Economizer for pre-cooling 9

2. Proposed Code Changes 10

Proposed Code Change Prescriptive requirement for waterside economizers Require water economizers on passive without fan systems Limit pressure drop of Heat exchangers Require cooling towers to operate efficiently when not economizing Require system to use Integrated Waterside Economizer for precooling Limits Approach by requiring water economizers to provide full cooling at 49 F wet-bulb, compared to the current 45 F requirement Revision to existing requirement Applies to Nonresidential buildings (not data centers) which use waterside economizer and undergo prescriptive compliance Does not apply to additions and alterations Aligns Title 24, Part 6 with 2016 ASHRAE 90.1-2016 11

Why Are We Proposing This Code Change? Support ZNE goals Achieve significant energy savings Significant water savings associated with heat rejection devices Align with ASHRAE 90.1-2016 Benefit from California s relatively dry climate with numerous economizer opportunity Pushes number of economizer hours closer to air-side economizer Support market trends toward high-efficiency, low-approach, high temperature chilled water distribution systems 12

Why Are We Proposing This Code Change? 13

What do you think? Do you understand the proposed code change? Does it seem reasonable to you?

3. Technical and Market Barriers 15

Technical and Market Barriers Increased Cooling Tower/Heat Exchanger Space/Weight Requirements Lower approach cooling towers/heat exchangers are larger in size Projects with space constraints can use performance compliance and use smaller, less efficient equipment Most large buildings use performance compliance Alterations are exempted Structural engineers indicated negligible affect on design for new construction 16

What do you think? What s your opinion of structural engineers assessment that there will be negligible affect on design for new construction? Are you aware of additional technical or market barriers that we haven t identified? 17

4. Compliance and Enforcement 18

Compliance Process Design Phase What happens during design phase Coordination of equipment selection and placement Lower approach towers/heat exchangers are larger and heavier, important for the design team to know and coordinate early in design process to ensure sufficient space exists Piping layout and controls for non-integrated (current requirement) and integrated (proposed requirement) are different Engineers need to learn new sequences and layouts Must specify chillers which perform well at low-lift conditions 19

Compliance Process Permit Application Phase What happens in permit application phase? Mechanical equipment design approaches, pressure drops, and system capabilities checked against requirements More requirements for waterside economizers create additional items which need to be checked for permit 20

Compliance Process Construction Phase What happens in construction phase? Equipment efficiency is certified by manufacturer Cooling towers less than 5 F approach cannot be certified by the Cooling Tower Institute (CTI) How can we ensure we are getting the required approach? Equipment is shipped to site and installed Process unchanged by proposal Equipment undergoes acceptance test by Mechanical Acceptance Test Technician to ensure rated efficiency Acceptance test must now show new compliant approaches 21

Compliance Process Inspection Phase What happens in permitting phase? Acceptance test documentation checked against prescriptive requirement and specified design Test must meet prescriptive requirements and/or specified design 22

Compliance and Enforcement Barriers The Cooling Tower Institute (CTI) certification of Low-Approach cooling towers CTI only certifies towers to a minimum of 5 F approach Manufacturers can design cooling towers to meet lower approaches, but these will not be CTI certified Gathered data for several low-approach cooling towers in operation, and analyzing to compare design approach to real-world performance Compliance issues since these towers will not be CTI certified how can we be sure that these towers actually operate as designed? Suggestions? 23

2-2 Poll What about compliance issues? 24

5. Cost-Effectiveness and Energy Impacts 27

Definition of Baseline and Proposed Conditions Baseline Conditions Minimally compliant with 2016 Standards or industry standard practice 500,000 square foot office Non-integrated economizer operation 5 degree approach cooling tower 4 degree approach heat exchanger Proposed Conditions Compliant with proposed code change (which prescriptive option did you analyze?) 500,000 square foot office Integrated economizer operation 3 degree approach cooling tower 2 degree approach heat exchanger 28

Cost Effectiveness Analysis Incremental Costs Incremental First Cost Heat Exchanger Lower Approach ($82/ton) Cooling Tower Lower Approach ($18/ton) Total Incremental First Cost ($100/ton) Incremental Maintenance Costs over 15-year period of analysis Maintenance Cost (negligible) Total Incremental Maintenance Cost ($0) Total Incremental Cost over 15-year period of analysis = $100/ton 29

Cost Effectiveness Analysis Incremental Cost Savings (Benefits) Energy Cost Savings over 15-year period of analysis Total Energy Cost Savings = range of $0.24 to $1.07/sf depending on climate zone Energy cost savings explained in more detail in following slides. 30

Benefit-to-Cost Ratio Climate Benefit to Cost Zone 1 3.0 2 2.2 3 2.6 4 2.4 5 6.5 6 1.3 7 1.2 8 1.4 9 2.1 10 2.2 11 1.1 12 2.1 13 1.6 14 4.7 15 2.4 16 1.7 Cost Effective in All Climate Zones If Benefit-to-Cost Ration is over 1, measure is cost effective. 31

Annual Energy Savings per Square Foot Climate Zone TDV Energy Savings (TDV kbtu/yr) 15-Year TDV Energy Cost Savings ($2020) 1 5.02 $0.15 2 5.02 $0.20 3 5.38 $0.18 4 5.83 $0.22 5 11.99 $0.16 6 3.18 $0.22 7 2.95 $0.22 8 3.32 $0.21 9 5.39 $0.23 10 6.56 $0.27 11 2.69 $0.22 12 4.94 $0.21 13 3.79 $0.21 14 10.39 $0.20 15 7.67 $0.28 16 3.82 $0.20 32

Annual Energy Savings per Square Foot Climate Zone Annual Electricity Savings (kwh/yr) Peak Electric Demand Reduction (kw) Annual Natural Gas Savings (therms/yr) 1 0.200 - - 2 0.204 - - 3 0.208 - - 4 0.240 - - 5 0.246 - - 6 0.131 - - 7 0.141 - - 8 0.163 - - 9 0.211 - - 10 0.259 - - 11 0.176 - - 12 0.197 - - 13 0.226 - - 14 0.279 - - 15 0.321 - - 16 0.130 - - 33

2-4 Poll What about the incremental costs & savings? This is the polling session that was set up in the meeting room and we played with a bit. (Julian now is comfy with how they work, so you needn t worry about that.) 34

6. Next Steps 37

Next Steps Please send any additional feedback within 2 weeks to: CASE Author (see contact info at end of this presentation) Info@title24stakeholders.com Keep an eye on Title24Stakeholders.com for: Presentations from today s meeting Draft Code Change Language Notes from today s meeting Draft CASE Report (will be posted in April) 38

3 Cool Tower 39 Let s move on to Prescriptive Efficiency Requirements for Cooling Towers Thank you. Stefan Gracik 510-663-2070 sgracik@integralgroup.com