D A T A L O G G I N G. Squirrel Data Logger 2020/2040 SERIES. Quick Start

Similar documents
Grant. Squirrel Data Logger 2010 SERIES. Getting Started

Squirrel Data Logger 2020/2040 SERIES. Getting Started

DATA ACQUISITION Hints and Tips

Squirrel Data Logger 2010 SERIES. Getting Started

USERGUIDE-V1 FOR SQ2040 DATALOGGER FROM GRANT- UK

Accsense Wireless System. Temperature Monitor

Squirrel Portable Data Loggers For research, quality assurance and production monitoring in industry, environmental sciences and in the laboratory

Precision thermometer Model CTR5000

EASYSENSE V-Log User Guide

Wireless 2.4GHz Keyboard & Mouse Combo USER GUIDE

7561-PSD Manual Portable Battery Powered Indicator

USER GUIDE FOR NETmc MARINE Four264 DVR

USER GUIDE FOR NETmc MARINE Four264 DVR

DL6 Data Logger. Quick Start Guide Version 1.2. Delta-T Devices Ltd

Hand-held thermometer Model CTH6200

RS Stock No Instruction Manual RS Input Data Logging Thermometer

DM650TM SENSOR / WALL MOUNTED TEMPERATURE DISPLAY

DRAFT. Customer site gravity factor. Filtering parameters. Five points for linearity correction to ensure maximum accuracy

Tinytag Thermohygrometer User Guide

Visible Light SD Card Datalogger

Humidity + Temp. + Dew Point Pocket size HUMIDITY METER. Model : HT-315

SpaceLogger.D10 USER MANUAL Richard Paul Russell Ltd. Richard Paul Russell Ltd

12-Channel Thermocouple Datalogger

GP1 Data Logger. Quick Start Guide v2.0. Delta-T Devices Ltd

Datapath North America 2550 Blvd of the Generals Suite 30 Norristown, PA U.S.A Tel:

C-Bus Pascal Automation Controller

Multi-functional precision thermometer CTR3000

GV-Joystick. User's Manual

DSC-N114_Network_Video_Recorder

Datalogging Hot Wire CFM Anemometer

Hand-held thermometer Model CTH6200

WARNING: Do not use the thermometer/data logger before you read the users manual and the following instructions.

INSTRUCTION MANUAL FOR TQ-8800 TORQUE METER PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION

QUICK START GUIDE. Multi Display Controller

RH/Temperature SD Card Datalogger. Instruction Manual

Lux Intelligent Emergency Light Testing System. Lx Features

Installation Guide. QBox-V6. Standalone/Spare V6 SDI QBox. Standalone/Spare V6 SDI QBox. Part No. A

Graphical User Interface V1.0.3

Quick Start Guide. January EAZ0081L02A Rev. A

Model 2000 Programmer EnSonic Display & Control Unit. Document code: M2KCNF.001

OPERATION MANUAL. SD card real time data Recorder, USB/RS232 SOUND LEVEL METER. Model : SL-4023SD. Your purchase of this

Network Camera. Quick Guide DC-B1203X. Powered by

IPM650 Intelligent Panel-Mount Display

DM650VI SENSOR/WALL MOUNTED VOLTAGE/mA DISPLAY

Up to two expansion cards can be added; these cards may either add an additional 4 analogue or 8 digital inputs.

Torque Meter. Instruction Manual

MobilControl MC 4000 OWNER S MANUAL

BLUE LOG XM / XC. Quick Start Guide. Version

Operating instructions Safe AS-i input module ASIM-C-M About this document. Content

AC/DC MAGNETIC METER

Quick Start Guide. Celeb 250/450/450Q LED DMX

Manual Digital Thermometer PCE-T 390

Technical documentation NLS-3000 NAVIGATION LIGHT CONTROL PANEL

8 channel universal input and 4 channel Form C digital output

SY021 Portable Load/Force Meter User instructions

DPM-3221 Digital DC Power Meter with data logging capability.

ADVANCED OPERATOR PANEL (AOP)

RS Stock No Instruction Manual RS Input Data Logging Thermometer

AX3000 Platine Terminal Ethernet TCP/IP

USER MANUAL MULTI COLOR TOUCH SCREEN PAPERLESS RECORDER TPLR-96 Series

Anemometer SD Card Datalogger. Instruction Manual

Tinytag Re-Ed Volt/mV/mA and Count Manual

INSTALLATION DKM-409 NETWORK ANALYSER WITH HARMONIC MEASUREMENT AND SCOPEMETER. Before installation:

DSM403SD USER S MANUAL

RADI-CEM. User manual. MPB S.r.l. Via Giacomo Peroni 400/ Rome - Italy. Tel Fax

LCM SYSTEMS. TR150 Portable Battery Powered Indicator. Instruction Manual. Software version V2.XX

one probe, SD card real time data recorder CO2, %RH, Temp., Dew point, Wet bulb CO2 METER + HUMIDITY/Temp. Model : CO2-9914SD

WTX110. Legal-for-trade industrial weighing terminal. Special features. Data sheet

HCS-3600 / 3602 / 3604 Laboratory Grade & High RFI Immunity Switching Mode Power Supply with Rotary Encoder Control

Electro Magnetic Compatibility (EMC)

615HD Digital Video Camera

Weilekes Elektronik GmbH Am Luftschacht Gelsenkirchen Germany Tel: Fax:

40.00/400.0/4,000/40,000/400,000 Lux LIGHT METER

Installation & User Manual V2.08

User s Manual. Models Digital Force Gauge. Additional User Manual Translations available at

HOBO State Data Logger (UX90-001x) Manual

Hygro-Thermometer / Datalogger

Model DVS-2A 2-Port DVI Switch with Audio, Serial Control & Long Cable Equalization

- NLS NAVIGATION LIGHT CONTROL

The Programmable 4-Way Relay Card is an optional peripheral unit that provides four individually programmable relay output circuits.

Agilent U2600A Series USB Isolated Digital I/O Devices. Data Sheet

AudioCodes C450HD IP Phone with Microsoft Skype for Business

THANK YOU FOR VOTING TEXECOM INSTALLATION MANUAL. Digi-modems. Issue 3

Simplex 4190 TrueSite Workstation (TSW) Software Upgrade Instructions

VisionRGB-PRO User Manual

700TSU INSTALLATION MANUAL

Installation & User Manual

4-Channel Thermometer / Datalogger

Guide Specification for 3G Wireless Battery Monitoring System

AVM-8880 USB Logging Anemometer

AX3000 Platine Terminal Ethernet TCP/IP

RS232 Control Box. Table of contents

Vibration Meter SD Card real-time datalogger

USB-5100 Series Multi-Channel Data Loggers

WIRELESS OFFICE DESKTOP SL DESIGN

USER MANUAL MULTI COLOR TOUCH SCREEN PAPERLESS RECORDER MODEL : ARC2020

Communication over Modbus protocol Connection with multiple controllers Application upgrade by using an SD 1) card or a USB stick

DIGITAL DISPLAY. for Industry Applications. Series WAY-SSI. Key-Features:

MasterBus USB interface

GS400. Electronic Auto-Ranging DIN Panel Mounted Positioner

Transcription:

D A T A L O G G I N G Squirrel Data Logger 2020/2040 SERIES Quick Start

1. Hardware Checklist 2020/2040 Logger x 1 CD containing software x 1 (SQA100) 2020/2040 SERIES Quick Start manual (this booklet) x 1 USB Cable x 1 (LC77) Mounting bracket/stand for logger x 1 (WB6) Batteries, 6 x AA Current shunt resistors, 10R x 4 (CS202) Connectors: 6 way x 4 (18097), 4 way x 1 (13975), 3 way x 1 (14174), with cable ties Note: 2040 Logger is supplied with an extra 4 x 6 way connectors as above (18097). Page 2

Contents 1 Hardware Checklist..2 2 General Information..4 3 Menu and Navigation..5 4 Getting Started..7 5 Connections..11 6 Specifications..13 After reading this Quick Start, please refer to SquirrelView Help for further details on your logger and how to use it with SquirrelView. Version 2 -July 2004 Page 3

2. General Information 2 Installing the batteries The 2020/2040 uses six AA size alkaline batteries located under the removable cover shown below. To insert new or change the existing batteries: 1. Open the battery cover by pushing down and sliding as shown. 2. Insert six AA* batteries, ensuring the correct polarity. 3. Refit the battery cover. * It is recommended that all replacement batteries are of the same manufacturer, type and condition. The 2020/2040 can be used in either the Battery mode or Externally powered mode. Battery mode When logging in this mode please ensure that the batteries in the unit have This can be checked via the sufficient capacity to complete the logging task. battery indicator located in the top right of the display. HIGH LOW Externally powered mode CAPACITY CAPACITY The logger may be powered from an external source (10-18V DC) Note: To ensure data protection in the case of an unexpected power loss, please ensure that batteries are fitted whilst the unit is operational. Page 4

3. Menu and Navigation 3.1 Control panel The illustration below shows the navigation controls in more detail. LEFT NAVIGATION KEY RIGHT NAVIGATION KEY ENTER/ CONFIRM & POWER ON KEY Esc ESCAPE KEY (reverts to previous menu) To use the 2020/2040 control panel press, the opening display will be shown (see right). The display timeout is preset to 10 seconds, however this can be changed by selecting the Configuration tab within the Logger Setup window of SquirrelView. --Main Menu----- Log Control 1/6 Page 5

3.2 Control panel menu Detailed below is a basic explanation of the top menu structure. For more information on the whole menu structure please refer to the Help/Help Content - Loggers within SquirrelView. 3.3.1 Log Control In this menu you can Arm (activate) or Disarm (deactivate) the logger. 3.3.2 Meter Here you can view each channel in Real Time mode, data will be updated every 1-2 seconds. You can also scroll or auto scroll through the channels. 3.3.3 Status The Status menu gives you access to information relating to the logger such as memory and power supply voltage. You can also override the alarm outputs in here. 3.3.4 Setup This contains menus for setting up Language, Time & Date and the opportunity to store and recall Setups. Data Files This menu allows you to copy data files to an external memory card (if fitted) and Data Files 5/6 delete the data files held within the logger s memory. 3.3.6 Tools The tools menu contains maintenance type functions such as querying the software version of the logger and performing a self test and resetting the Logger. Page 6

4. Getting started 4.1 Quick Start example After installing SquirrelView an example setfile will be installed within the SquirrelView installation directory. The example file will log the internal temperature of the logger. In order to familiarise yourself with the logger the novice user may find this example Setup useful. 4.2 Installing SquirrelView software Install the software by following the instructions on the SquirrelView Installation Guide. Connect the 2020/2040 to the PC via either USB or Serial connections. If you are using USB the PC will request the USB drivers (it is assumed that SquirrelView is installed into the default directory, if this is not the case then modify the path accordingly), select C:\Program Files\SquirrelView\USB\ then click OK to complete the installation. Please ignore the Hardware Installation warning that refers to Windows Logo testing. 4.3 Startup SquirrelView and select Logger Type Click on the shortcut icon on your desktop to launch SquirrelView or select it from your start menu - Program group menu within Windows. When the SquirrelView Assistant has opened, ensure the correct logger type and communication method is selected. This can be viewed in the top right corner of the screen, if you need to make any changes select Logger Selection from the toolbar or run the Communication Wizard. 4.4 Synchronise Logger & PC It is advisabl e to start by synchronising the Logger clock with the PC clock. See step 1 and 2 below: Synchronise clocks: 1 From SquirrelView Assistant click on Logger Setup. 2 From the Logger Setup screen select the Logger Control tab. Click on Set Logger Time to PC Time, click OK on the confirmation screen. Page 7

4.5 Running Quick Start Demo 1 In the SquirrelView Assistant, double click on Browse..or select File - Open from Logger setup to open a setfile Or select the quick start demo file appropriate to your logger type. 1 2 The Logger Setup screen is now visible, from here you will be able to set up your logging requirements. Within the Actual Channels tab scroll down the Sensor Type column to Ref.J1. This will be the input you will be reading in this example. 3 The Job Description can be used to describe your setup. 2 3 Page 8

4 Click to send setup to logger and start logging. Let the unit log for a few minutes. 5 6 If you 7 To Click for SquirrelView Assistant. meter the input in Real Time click this icon. wish to stop the logging process click the Logger Control icon. pause or 8 In the Logger Control window you can view relevant information on the state of the logger. To stop logging click ȯn the stop button. 9 To Download the logger click on the Download Data icon from the SquirrelView Assistant. Page 9

10 In this screen you can now download the Data file and invoke the Export Wizard or download the Datafile via Analysis* The datafile is given a unique name (e.g. 28162735.D20). An explanation of the file name is shown on the right. DATE SECONDS 28162735.D20 TIME(24HR) In this example you will download and view the Data in the Analysis* window. Start by selecting the Data file and Graph Data action, then click Download Selected File(s). You will be prompted to save the Data file. Once you have done this then the data will be converted for viewing. *Available with SquirrelView Plus only. 11 Once the decoding has 11 taken place the Analysis Job Description window will be presented, click OK to view your data. Page 10

5. Connections I/O SOCKET Wiring information ALARM O/P EVENT/STATE I/P 1-8 PIN 1 Aux. Output Max 500mA SLOW PULSE I/P 1-2 FAST PULSE I/P 1-2 Page 11

Analogue Inputs (I/P) A C E 1 2 1 2 4 5 4 5 1 2 1 2 4 5 4 5 1 3 1 2 4 Rear view of ANALOGUE connectors B D F G J 1 2 1 2 4 5 4 5 1 2 1 2 4 5 Rear view of ANALOGUE NOTE: Blocks G TO K are only 4 5 connectors available on 2040 loggers. H K FOR ANALOGUE INPUT CONNECTIONS REFER TO SquirrelView/ Logger Setup/Sensor Type. E F UNREGULATED LOGGER SUPPLY OUTPUT V1(+) REGULATED 5V OUTPUT NEGATIVE V1(-) V2(-) V2(+) SENSOR POWER SUPPLIES HIGH VOLTAGE INPUT Page 12

6. Specifications ANALOGUE INPUTS Basic accuracy: (5-45 C). Common mode rej e ction:. Input impe d ance:. Linearity:. Series mode line rejection:. ANALOGUE-DIGITAL CONVERSION Type:. Resolution:. Sampling rate:..± (0.05% readings + 0.025% range).100db.> 1MOHM.0.015%.50/60Hz 100dB.Sigma-Delta.24bit.Up to 20/100 readings per second Note: 100Hz Mode not available on 1F8 models ALARM OUTPUTS. SENSOR POWER SUPPLY. TIME AND DATE. SCALING DATA. MEMORY. RESOLUTION. PROGRAMMING/LOGGER SET-UP. COMMUNICATION. External options:..4 x open drain FET (18V 0.1A Max).Regulated 5 VDC (50mA) or supply voltage (100mA).In built clock in 3 formats.displays readings in preferred engineering units.internal: 16Mb (Up to 1,800,000 readings) External: Up to 64Mb removable MMC.Up to 6 significant digits.squirrelview or SquirrelView Plus software.usb 1.1 and 2.0 / RS232.GSM and Ethernet Page 13

POWER SUPPLY Internal:. External:..6* x AA Alkaline batteries.10-18vdc Reverse polarity and over-voltage protected * Maximum operating temperature for AA alkaline batteries is 50 C POWER CONSUMPTION @ 9V Sleep mode:. Logging:..<600µA.40-80mA DIMENSIONS AND WEIGHT 2020 Logger Dimensions:. Weight:. Enclosure material:. 2040 Logger Dimensions:. Weight:. Enclosure material:..w235 x D175 x H55 mm.approx 1.2kgs. ABS.W235 x D175 x H92 mm.approx1.5kgs.abs MEMORY MODES (internal only)..stop when full or overwrite DISPLAY AND KEYPAD 2 line x 20 character LCD display OPERATING ENVIRONMENT..-30 C to +65 C Windows is a registered trademark of Microsoft Corporation in the United States and other countries. Due to our policy of continuous improvements, specifications may change without prior notice. Grant believe that all information declared is correct at the time of issue. No liability is accepted for errors and omissions. Page 14

Declaration of Conformity Manufacturer: GRANT INSTRUMENTS (CAMBRIDGE) LTD, Shepreth, Cambridgeshire SG8 6GB Equipment Name/Type Number: 2020/2040 Description of Equipment: Directives: Squirrel 2020/2040 Data Logger EMC Directive 89/336/EEC Including Accessories: MPU 12V Universal power supply LC71 RS232 serial lead LC77 USB lead This product complies with the requirements of the above Directive(s) Applied Standards: Harmonized Standards: EN 61326-1:1998 (+A1/A2) Electrical Equipment for measurement, control and laboratory use - EMC requirements USA This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. AUSTRALIA & NEW ZEALAND ANC 006 134 863 This product complies with the requirements of the European EMC standards indicated above which meet the requirements for C-Tick marking. Page 15

Grant Instruments (Cambridge) Ltd Shepreth, Cambridgeshire SG8 6GB Tel: +44 (0)1763 260811 www.grant.co.uk loggersales@grant.co.uk Fax: +44 (0)1763 262410 Printed in England - Squirrel/2020/2040-/UK