Data sheet. Constant current DALI LED control gear 80 W Output power ma Output current Intelligent temperature protection.

Similar documents
OTi DALI 75/ /700 D LT2 UF L

LL1x50-E-DA. 1x50 W Dimmable DALI LED driver. 50 W V 0 / 50 Hz 60 Hz. Functional description. Mains characteristics

COMPACT LED DRIVERS. PrimeLine DALI dimmable & Selectable Current (Dip Switch) PrimeLine DALI DIMMABLE & SELECTABLE CURRENT (DIP SWITCH)

CV Power supplies with DALI

LL1x150-CR-DA. 150 W Dimmable DALI-2 LED driver. 150 W V 0 / Hz. Functional Description. Mains Characteristics

LL1x80-CR-DA. 80 W Dimmable DALI-2 LED driver. 80 W V 0 / Hz. Functional Description. Mains Characteristics

COMPACT LED CONVERTERS 48 V

COMPACT LED DRIVERS. EasyLine Simple Fix. EasyLine SIMPLE FIX , , , , , , , , ,

LINEAR LED DRIVERS. PrimeLine DALI dimmable. PrimeLine DALI DIMMABLE , , , , ,

DeltaV Bulk Power Supplies

LC35SE-DA W SELV Dimmable DALI-2 LED driver. 35 W V 0/ Hz. Functional Description. Mains Characteristics

Withstands max. 320 VAC (max. 1 hour) *) Low frequency, LED load: Cree XP-G L LEDs. 350 ma 600 ma Fixed output 850 ma P Rated

CC COMPACT DIP SWITCH

COMPACT LED DRIVERS. ComfortLine Residential. ComfortLine RESIDENTIAL , , ,

LINEAR LED DRIVERS. ComfortLine Industry Selectable Current (LEDset) ComfortLine INDUSTRY SELECTABLE CURRENT (LEDset) ,

DeltaV Bulk Power Supplies

This installation guide provides instructions for installing the SPARTAN HP Highbay/ Floodlight series of explosion protected floodlights.

LC35SE-CC LOOP

LC51SE-CC LOOP

COMPACT LED DRIVERS. EasyLine Selectable Current (Output Terminal) EasyLine SELECTABLE CURRENT (OUTPUT TERMINAL) , , ,

Operating and mounting instructions

COMPACT LED DRIVERS. EasyLine Simple Fix. EasyLine SIMPLE FIX , , , , ,

MINI MCR-SL-CVS NC

ETD-BL-1T-OFF-CC- 10S

QUINT-PS/ 1AC/24DC/ 5

LED Driver Linear / area fixed output

LED power supplies Constant voltage. Uconverter LCU 180W 12/24V IP67 TOP Outdoor IP67 series

LINEAR LED DRIVERS. EasyLine Simple Fix. EasyLine SIMPLE FIX , , , , ,

LED Driver Linear / area fixed output

Safety instructions. IECEx TUN Ex ia IIC T6 Gb

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

LED Driver Constant voltage. Udriver LCU 100/96W 12/24V IP67 EXC EXCITE outdoor IP67 series

MINI MCR-SL-RPS-I-I. Repeater power supply, active. Data sheet. 1 Description

LINEAR LED DRIVERS. ComfortLine NFC. ComfortLine NFC , , ,

Product data sheet: OTi DALI 25/ /700 LT2 G2

LED Driver Constant voltage. Udriver LCU 180W 12/24V IP67 EXC EXCITE outdoor IP67 series

Product and Applications Description. Example of Operation. Installation Instructions WARNING. Note. Application Programs

SITOP in the SIMATIC Design

Linear Luminaire with LED Series 6412/5

TRIO-PS/1AC/24DC/20. Extract from the online catalog. Order No.:

Xitanium. Xitanium Basic Prog LED Outdoor drivers. LED driver. Datasheet. Xi BP 12W A S 230V C100

PHOENIX CONTACT - 08/2009. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

Assembly. Front view. LED yellow: Relay output. LED red: LB/SC Power Rail

RAD-DI8-IFS. I/O extension module with 8 digital inputs or 2 pulse inputs. INTERFACE Data sheet. 1 Description

LED Driver Linear / area fixed output

MINI MCR-SL-UI-2I. Configurable signal duplicator. Data sheet. 1 Description

Xitanium LED Xtreme drivers Sensor Ready

Philips Lumiblade OLED Driver (low voltage)

Operating Instructions (Translation) 3. Safety Information. 1. Description. 2. Explosion Protection. Supply module Type 17-21BB-170x

Xitanium. LED driver. Datasheet. Xitanium LED drivers - linear LV isolated. Xitanium 25W 0.5/0.6A 42V V

PHOENIX CONTACT - 12/2007

MINI MCR-SL-MUX-V8-FLK 16

ASI QUINT /2.4 EFD

PI-EX-ME-2NAM/COC-120VAC

SITOP 3-phase 24 V DC, 20 to 40 A

STEP-PS/1AC/24DC/1.75

Electronic ballasts for fluorescent lamps Products for special applications. PC BASIC, 4 28 W Electronic ballast for system output < 25 W

Philips Lumiblade OLED driver, mains voltage D230V 80W/ /1A/28V TD/A 8CH

PI-EX-ME-2NAM/COC-24VDC

Application wireless configuration interface Area lighting Long lifetime and robust protection against moisture,

Assembly. Front view. LED yellow/red: Status output Ι/ Fault signal Function. Switch Power Rail

ABB i-bus KNX DALI Light Controller, 8-fold, MDRC DLR/S M, 2CDG110101R0011

Interface and Supply module. IPC 3x0i / PSC 3x0i

Safety instructions Overvoltage protection B81-35

FL ballasts Electronic fixed output. PC T5 PRO-M lp, W PC PRO-M (T5) Ø 4.1. Ordering data

QUINT-PS/1AC/24DC/10. Extract from the online catalog. Order No.:

PHOENIX CONTACT - 07/2006

Redundancy Module QUINT-DIODE/40

MINI MCR-SL-PT100-UI-200

PHOENIX CONTACT - 06/2007. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area.

Termination Board FC-GPCS-SAI16-PF. Features. Assembly. Function. Connection. SAI-1620m HART 24 V DC (I), 24 V DC (II) Fault. Zone 0, 1, 2 Div.

LED Driver Linear / area dimming

Product and Applications Description. Application Programs. Note. instabus EIB Technical Product Information. June 2005

LED Driver Compact fixed output

ETD-BL-1T-230(-PT) Multifunctional time relay with various functions and adjustable times. Data sheet. 1 Description

LED Driver Compact fixed output

MINI MCR-SL-PT100-UI. Active resistance thermometer measuring transducer. Data sheet. 1 Description

50W 0-10V LED Driver with Smooth Dimming to 1%

SOLOdrive AC, 100W, DALI, 1 control channel, constant current, 4x 57V outputs, side feed, square metal

LEDLight 20 W Wide voltage series

DATASHEET. ilc PRO 40/ XT-IP67. Full PROGRAMMABLE control gear up to 40W. IP67

LED FlatPanel Gen. 2 DALI

QUINT-PS/ 1AC/24DC/20/CO

LED Driver Linear / area dimming

Inductive sensor Dual sensors with extended temperature range NI4-DSU35TC-2Y1X2/S97

PHOENIX CONTACT - 01/2008

Electrical devices may only be mounted and connected by electrically skilled persons.

Safety instructions VEGATOR 121, 122

PHOENIX CONTACT Features

Digital input modules

RAD-DOR4-IFS. I/O extension module, 4 digital relay outputs. INTERFACE Data sheet. 1 Description

STEP-PS/1AC/24DC/2.5. Extract from the online catalog. Order No.: DIN rail power supply of 24 V DC/2.5 A, primary switched, single phase.

LED Driver Linear / area fixed output

Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,

LED Driver Linear / area fixed output

OPTOTRONIC OT 45/ /700 LTCS 700mA Constant Current LED Power Supply and DIPswitch

LED Driver DC-String

LED Driver Linear / area dimming

2.3. Ex-Linear light fittings for fluorescent lamps. ellk W 58 W / ellm W 36 W (Zone 1, 2, 21, 22)

PHOENIX CONTACT Pin. SUBCON-PLUS M ARCNET, MULTI/MININET (B&R), SYSTEM 2003 (B&R), P-NET SUCONET K1, K2 (EATON/Moeller),

Transcription:

Data sheet Constant current DALI LED control gear 8 W Output power 5 7 ma Output current Intelligent temperature protection Linear VI LED

Linear VI LED control gear More than 25 years of experience in the design and development of electronic lighting products, the close cooperation with test authorities and the joint research in the sector of explosion protection enable the company Hadler to develop products in accordance with market trends which will exactly meet the requirements. Function and, above all, safety will take priority over other requirements. Table of contents ECG 5 35 ma, 8 W, 22 24 V, DALI 4 ECG 1 5 ma, 8 W, 22 24 V, DALI 1 ECG 25 7 ma, 8 W, 22 24 V, DALI 16 Furthermore, in accordance with the company philosophy, Luxtronic ballasts also reflect the second idea : Features offering an additional benefit and using the full competence of the company Hadler to allow for a unique position in the market. Both large-scale and small-scale series of the Luxtronic ballasts can be produced in a cost-effective way. The proximity to the market allows for short delivery times. Michael Lamkowski Head of Research & Development 2 I data sheet LED control gear Linear VI LED 1/215 Technical changes reserved www.luxtronic.de 3

ECG 5 35 ma, 8 W, 22 24 V, DALI Input Rated supply voltage Mains frequency Input voltage range a.c. Input voltage range d.c. Power factor Total Harmonic Distortion 22 24 V / 5 6 Hz 198 264 V 176 275 V.98 at full load (see graph) < 8 % at full load Power factor 1..96.92.88.84.8 1 2 3 4 5 6 7 8 Temperature, Lifetime Ambient temperature range -4 7 C Max. case temperature 85 C T a 5 C 6 C 7 C T c 65 C 75 C 85 C lifetime > 16, h 1, h 5, h P OUT [W] Output Max. No. of ECG per circuit breaker Output characteristic Constant current, non-selv Output voltage 25 325 V (see graph) Output current 5 35 ma Output power 1 8 W No. of output channels 1 Output current accuracy +/- 5 % Output current ripple < 1 % at 1 Hz Output dimming AM Dimming range 1 1 % Output voltage [V] 35 3 25 2 15 1 5 1 2 3 4 Type B1 8 pcs. C1 13 pcs. B16 12 pcs. C16 21 pcs. Wiring Max. output cable length 2 cm Input wire cross-section.5 1.5 mm² Output wire cross-section.5 1.5 mm² Output current [ma] The wiring should be short and without crossings for best EMC results. Efficiency Stand-By Power consumption No-load Power consuption Electrical efficiency Interface Dimming Interface Interface control current Dimming curve <.5 W.5 W >.95 at full load (see graph) DALI, non SELV 2 ma log. / linear η [%] 98 95 92 89 86 83 8 1 2 3 4 5 6 7 8 P OUT [W] Dimensions Length x Width x Height Mounting hole distance D Mounting screws (see schematic view on the right) Ordering data Weight Packaging unit 36 x 3 x 21 mm 35 mm M4 max..2 kg 72 pcs. L W H 175 ma 35 ma Order No. 3 C 18 8 6 D 4 I data sheet LED control gear Linear VI LED 1/215 Technical changes reserved www.luxtronic.de 5

ECG 5 35 ma, 8 W, 22 24 V, DALI Emergency lighting, performance during DC power supply Standards The electronic ballast is equipped with an integrated supply voltage detection which EN 61347-1 allows a certain DC-supply mode. EN 61347-2-13 EN 62384 The following values are factory-adjusted: EN 62386 DC supply level 229 5% EOF (Emergency Output Factor) EN 5515 Time to light.3 s suitable for high-risk task area lighting EN 61547 EN 61-3-2 EN 61-3-3 EN 679- Temperature protection EN 679-15 The unit operates an integrated temperature overload protection which reduces the 1 A Markings output power by linear decrease if a certain operating point A is reached and reduces the output power to zero if the temperature at operating point B is exceeded. The control gear restarts automatically if the temperature decreases by 5 K. The following values are factory-adjusted: Dimming level [%] B 11 Temperature A T board = 9 C T c = 75 8 C Temperature B T board = 95 C T c = 8 85 C Temperature [ C] Wiring diagram Temperature limit level B 229 5% L N 8.5-9.5 mm 8.5-9.5 mm DA DA.5-1.5.5-1.5 6 I data sheet LED control gear Linear VI LED 1/215 Technical changes reserved www.luxtronic.de 7

ECG 5 35 ma, 8 W, 22 24 V, DALI Safety instructions Please carefully read these instructions prior to installation and keep them for later reference. Installation precautions This control gear may be installed into housings of explosion protected luminaires with a minimum type of protection of the housing of IP54 according to IEC 6529. This control gear is intended for operation of LED modules in explosion protected luminaires. Please ensure that ratings of the LED module match with the output range of the ECG. Do not use this product for other than intended use. Hadler GmbH declares that this control gear is in conformity with the EU explosion protection directive 94/9/EC (ATEX). Compliance with requirements of IEC 679-:211 and IEC 679-15:21 is laid down in certificate number IECEx TUN 15.1 U. II 3 G Ex na IIC Gc U Ex na IIC Gc U Keep in mind that the output is NOT isolated against mains voltage. Proper insulation of the output circuits is mandatory. Dismantled length of wires has to be between 8.5 and 9.5 mm. At use of finestranded wires, conductor sleeves have to be used. Permissible cross section of wires is from.5 up to 1.5 mm². Maximum temperature rise at internal components is 48 K. Devices contain no field-serviceable parts. In case of malfunction, contact the manufacturer. The sign U placed after certificate number and ATEX marking indicates, that the corresponding certificate is not equivalent to a Statement of Conformity for an equipment or protective system. It is intended to be used as a basis for certifying an equipment or protective system. Certificates and detailed product datasheets are available at www.hadler-gmbh.de. For operation conditions see pages 4 6. 8 I data sheet LED control gear Linear VI LED 1/215 Technical changes reserved www.luxtronic.de 9

ECG 1 5 ma, 8 W, 22 24 V, DALI Input Rated supply voltage Mains frequency Input voltage range a.c. Input voltage range d.c. Power factor Total Harmonic Distortion 22 24 V / 5 6 Hz 198 264 V 176 275 V.98 at full load (see graph) < 8 % at full load Power factor 1..96.92.88.84.8 1 2 3 4 5 6 7 8 Temperature, Lifetime Ambient temperature range -4 6 C Max. case temperature 8 C T a 5 C 6 C 7 C T c 65 C 75 C 85 C lifetime > 16, h 1, h 5, h P OUT [W] Output Max. No. of ECG per circuit breaker Output characteristic Constant current, non-selv Output voltage 25 325 V (see graph) Output current 1 5 ma Output power 1 8 W No. of output channels 1 Output current accuracy +/- 5 % Output current ripple < 1 % at 1 Hz Output dimming AM Dimming range 1 1 % Output voltage [V] 35 3 25 2 15 1 5 1 2 3 4 5 Type B1 8 pcs. C1 13 pcs. B16 12 pcs. C16 21 pcs. Wiring Max. output cable length 2 cm Input wire cross-section.5 1.5 mm² Output wire cross-section.5 1.5 mm² Output current [ma] The wiring should be short and without crossings for best EMC results. Efficiency Stand-By Power consumption No-load Power consuption Electrical efficiency Interface Dimming Interface Interface control current Dimming curve <.5 W.5 W >.95 at full load (see graph) DALI, non SELV 2 ma log. / linear η [%] 97 95 93 91 89 87 85 1 2 3 4 5 6 7 8 P OUT [W] Dimensions Length x Width x Height Mounting hole distance D Mounting screws (see schematic view on the right) Ordering data Weight Packaging unit 36 x 3 x 21 mm 35 mm M4 max..2 kg 72 pcs. L W H 25 ma 5 ma Order No. 3 C 18 18 6 D 1 I data sheet LED control gear Linear VI LED 1/215 Technical changes reserved www.luxtronic.de 11

ECG 1 5 ma, 8 W, 22 24 V, DALI Emergency lighting, performance during DC power supply Standards The electronic ballast is equipped with an integrated supply voltage detection which EN 61347-1 allows a certain DC-supply mode. EN 61347-2-13 EN 62384 The following values are factory-adjusted: EN 62386 DC supply level 229 5% EOF (Emergency Output Factor) EN 5515 Time to light.3 s suitable for high-risk task area lighting EN 61547 EN 61-3-2 EN 61-3-3 EN 679- Temperature protection EN 679-15 The unit operates an integrated temperature overload protection which reduces the 1 A Markings output power by linear decrease if a certain operating point A is reached and reduces the output power to zero if the temperature at operating point B is exceeded. The control gear restarts automatically if the temperature decreases by 5 K. The following values are factory-adjusted: Dimming level [%] B 11 Temperature A T board = 9 C T c = 75 8 C Temperature B T board = 95 C T c = 8 85 C Temperature [ C] Wiring diagram Temperature limit level B 229 5% L N 8.5-9.5 mm 8.5-9.5 mm DA DA.5-1.5.5-1.5 12 I data sheet LED control gear Linear VI LED 1/215 Technical changes reserved www.luxtronic.de 13

ECG 1 5 ma, 8 W, 22 24 V, DALI Safety instructions Please carefully read these instructions prior to installation and keep them for later reference. Installation precautions This control gear may be installed into housings of explosion protected luminaires with a minimum type of protection of the housing of IP54 according to IEC 6529. This control gear is intended for operation of LED modules in explosion protected luminaires. Please ensure that ratings of the LED module match with the output range of the ECG. Do not use this product for other than intended use. Hadler GmbH declares that this control gear is in conformity with the EU explosion protection directive 94/9/EC (ATEX). Compliance with requirements of IEC 679-:211 and IEC 679-15:21 is laid down in certificate number IECEx TUN 15.1 U. II 3 G Ex na IIC Gc U Ex na IIC Gc U Keep in mind that the output is NOT isolated against mains voltage. Proper insulation of the output circuits is mandatory. Dismantled length of wires has to be between 8.5 and 9.5 mm. At use of finestranded wires, conductor sleeves have to be used. Permissible cross section of wires is from.5 up to 1.5 mm². Maximum temperature rise at internal components is 48 K. Devices contain no field-serviceable parts. In case of malfunction, contact the manufacturer. The sign U placed after certificate number and ATEX marking indicates, that the corresponding certificate is not equivalent to a Statement of Conformity for an equipment or protective system. It is intended to be used as a basis for certifying an equipment or protective system. Certificates and detailed product datasheets are available at www.hadler-gmbh.de. For operation conditions see pages 1 12. 14 I data sheet LED control gear Linear VI LED 1/215 Technical changes reserved www.luxtronic.de 15

ECG 25 7 ma, 8 W, 22 24 V, DALI Input Rated supply voltage Mains frequency Input voltage range a.c. Input voltage range d.c. Power factor Total Harmonic Distortion 22 24 V / 5 6 Hz 198 264 V 176 275 V.97 at full load (see graph) < 8 % at full load Power factor 1..96.92.88.84.8 1 2 3 4 5 6 7 8 Temperature, Lifetime Ambient temperature range -4 5 C Max. case temperature 75 C T a 4 C 45 C 5 C T c 65 C 7 C 75 C lifetime 1, h 75, h 5, h P OUT [W] Output Max. No. of ECG per circuit breaker Output characteristic Constant current, non-selv Output voltage 25 325 V (see graph) Output current 25 7 ma Output power 1 8 W No. of output channels 1 Output current accuracy +/- 5 % Output current ripple < 1 % at 1 Hz Output dimming AM Dimming range 1 1 % Output voltage [V] 35 3 25 2 15 1 5 2 3 4 5 6 7 Type B1 8 pcs. C1 13 pcs. B16 12 pcs. C16 21 pcs. Wiring Max. output cable length 2 cm Input wire cross-section.5 1.5 mm² Output wire cross-section.5 1.5 mm² Output current [ma] The wiring should be short and without crossings for best EMC results. Efficiency Stand-By Power consumption No-load Power consuption Electrical efficiency Interface Dimming Interface Interface control current Dimming curve <.5 W.5 W >.95 at full load (see graph) DALI, non SELV 2 ma log. / linear η [%] 97 95 93 91 89 87 85 1 2 3 4 5 6 7 8 P OUT [W] Dimensions Length x Width x Height Mounting hole distance D Mounting screws (see schematic view on the right) Ordering data Weight Packaging unit 36 x 3 x 21 mm 35 mm M4 max..2 kg 72 pcs. L W H 35 ma 7 ma Order No. 3 C 18 28 6 D 16 I data sheet LED control gear Linear VI LED 1/215 Technical changes reserved www.luxtronic.de 17

ECG 25 7 ma, 8 W, 22 24 V, DALI Emergency lighting, performance during DC power supply Standards The electronic ballast is equipped with an integrated supply voltage detection which EN 61347-1 allows a certain DC-supply mode. EN 61347-2-13 EN 62384 The following values are factory-adjusted: EN 62386 DC supply level 229 5% EOF (Emergency Output Factor) EN 5515 Time to light.3 s suitable for high-risk task area lighting EN 61547 EN 61-3-2 EN 61-3-3 EN 679- Temperature protection EN 679-15 The unit operates an integrated temperature overload protection which reduces the 1 A Markings output power by linear decrease if a certain operating point A is reached and reduces the output power to zero if the temperature at operating point B is exceeded. The control gear restarts automatically if the temperature decreases by 5 K. The following values are factory-adjusted: Dimming level [%] B 11 Temperature A T board = 9 C T c = 75 8 C Temperature B T board = 95 C T c = 8 85 C Temperature [ C] Wiring diagram Temperature limit level B 229 5% L N 8.5-9.5 mm 8.5-9.5 mm DA DA.5-1.5.5-1.5 18 I data sheet LED control gear Linear VI LED 1/215 Technical changes reserved www.luxtronic.de 19

ECG 25 7 ma, 8 W, 22 24 V, DALI Safety instructions Please carefully read these instructions prior to installation and keep them for later reference. Installation precautions This control gear may be installed into housings of explosion protected luminaires with a minimum type of protection of the housing of IP54 according to IEC 6529. This control gear is intended for operation of LED modules in explosion protected luminaires. Please ensure that ratings of the LED module match with the output range of the ECG. Do not use this product for other than intended use. Hadler GmbH declares that this control gear is in conformity with the EU explosion protection directive 94/9/EC (ATEX). Compliance with requirements of IEC 679-:211 and IEC 679-15:21 is laid down in certificate number IECEx TUN 15.1 U. II 3 G Ex na IIC Gc U Ex na IIC Gc U Keep in mind that the output is NOT isolated against mains voltage. Proper insulation of the output circuits is mandatory. Dismantled length of wires has to be between 8.5 and 9.5 mm. At use of finestranded wires, conductor sleeves have to be used. Permissible cross section of wires is from.5 up to 1.5 mm². Maximum temperature rise at internal components is 48 K. Devices contain no field-serviceable parts. In case of malfunction, contact the manufacturer. The sign U placed after certificate number and ATEX marking indicates, that the corresponding certificate is not equivalent to a Statement of Conformity for an equipment or protective system. It is intended to be used as a basis for certifying an equipment or protective system. Certificates and detailed product datasheets are available at www.hadler-gmbh.de. For operation conditions see pages 16 18. 2 I data sheet LED control gear Linear VI LED 1/215 Technical changes reserved www.luxtronic.de 21

Hadler GmbH Fritzlarer Straße 19 34587 Felsberg-Neuenbrunslar Tel.: +49 5662 9399- Fax: +49 5662 9399-29 E-Mail: info@hadler-gmbh.de http://www.hadler-gmbh.de/en/luxtronic/all-products/