Capacitive Limit Detection minicap FTC 260, FTC 262

Similar documents
Minicap FTC260, FTC262

Technical Information Minicap FTC260, FTC262

Assembly. Function 41

TECHNICAL INFORMATION Vibracon LVL-B1, LVL-B2

Capacitance level switches LS 210 LS 220

Liquipoint T FTW 31, FTW 32 Level limit switch for multiple point detection in conductive liquids

Assembly. max Example: 2-wire connection IH More connection types see section electrical connections. Auxiliary voltage.

Liquipoint T FTW31, FTW32

System Components Surge Arrester HAW 261 and HAW 262

NIVOSWITCH VIBRATING FORK LEVEL SWITCHES

FOR LIQUIDS AND SOLIDS

Liquiphant T FTL20. Technical Information. Level limit switch for liquids

LS 5000 series Vibration Level Switch for liquids

Process display RIA 251. Digital loop powered display for ma current loops. Application areas. Plant and machine construction.

CAPACITIVE: CONTROL CLS2 CLS4 CLS5. Applications liquids / solids liquids / solids solids / granules

Operating Instructions Soliswitch FTE20

Soliphant M FTM50, FTM51, FTM52

Easy Analog RNB130. Technical Information. Primary switched-mode power supply

Technical Information Promonitor NRF560

LS 6600 Technical Datasheet

4 â Active barrier RN221N with optional HART diagnosis. Technical Information

Signal conditioning instruments for level switches. Conductive VEGATOR 256C VEGATOR 532 VEGATOR 631. Product Information

Pressure transmitter for highest pressure applications Up to 217,500 psi (15,000 bar) Model HP-2

Assembly. 1 Compact version with valve plug 2 Short tube version with cable 3 Compact version with M12 plug 4 Short tube version with M12 plug

DMP 333 DMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial

Level. Conductive. Level detection. Overview Page 142 VEGAKON series 60 Page 144 EL 1 EL 8 Page 148 Limit switches VEGATOR Page 157

Level measurement CleverLevel LBFI Point level detection

Flow Measurement SITRANS F M. Transmitter MAG 6000 I/6000 I Ex de. 3/46 Siemens FI

Operating Instruction

Siemens AG Continuous level measurement - Radar transmitters. Configuration. Mounting on a nozzle. Installation min.

Operating Instructions

E2Q4 Square Proximity Sensor

Technical Data Sheet. OPTISWITCH 3000 series Vibration level switch. for solids

Temperature Switches

Level measurement CleverLevel LBFI Point level detection

Level instruments. Point level measurement - Capacitance switches. Pointek CLS300 5/31

ISO-9001:2000 certified. SAL Series RF Admittance Point Level Sensor. Aplus Finetek Sensor, Inc.

Float Switches with Permanent Magnet For Vertical Installation Model RSM

Technical Information RIA15

Miniaturised pressure sensor Model M-10, standard version Model M-11, version with flush diaphragm

Continuous level measurement Radar transmitters

Series 3730 Electropneumatic Positioner Type

Level measurement CleverLevel LBFH Point level detection

Technical Information Liquipoint FTW23

Technical Information RIA16

Prosonic T FMU30. Technical Information

Soliphant M with electronic insert FEM54

Technical Data Sheet. OPTISWITCH 3000 series Vibration level switch. for solids

Endress Hauser CUM 740. Measuring Transmitter for Turbidity and Solids Content ISO The Power of Know How

itemp TMT180 Technical information

Series 3730 Type Electropneumatic Positioner

Level limit switch Series RF 3000 Selection list. Overview 2

Level instruments. Point level measurement - Capacitance switches. Pointek CLS200 5/15. Overview. Configuration

Level sensor Stainless steel version Model RLT-1000, for industrial applications

CATALOGUE CAPACITIVE SENSORS KXS

Electronic pressure switch with display For sanitary applications Model PSA-31

SAL Series RF Admittance Point Level Sensor

Continuous level measuring system NB 3000 Selection list

Multi-range pressure and differential pressure transmitter

Thread length. 27 (40) mm. 27 (44) mm. 27 (40) mm. 34 (50) mm. 34 (49) mm. 39 (60) mm. 39 (54) mm. 44 (65) mm. 44 (59) mm

JUMO PINOS L01. Calorimetric flow sensor. Brief description. Special features. Customer benefits. Data Sheet

Mobrey Squitch 2. Ultrasonic Liquid Level Switch. Product Data Sheet December 2014 IP207, Rev DA

Silopilot T FMM20. Technical Information. Electromechanical Level System

Flow Computer compart DXF 351. Universal Application for Gas, Steam and Liquids

E2A. Ordering Information. Cylindrical Proximity Sensor. Safe Mounting with Greater Sensing Distance. E2A Cylindrical Proximity Sensor 1

Thread length (overall length) material

Flow Measurement SITRANS F M

Flow Measurement SITRANS F M

Contact protection relay

Solid-state Timer H3YN

Pressure sensor For highest pressure applications to 15,000 bar Model HP-2

Electronic pressure switch with display Model PSD-4

Functional safety manual Liquiphant M/S with FEL58 and Nivotester FTL325N

Suitable for detecting transparent films or transparent bottles

Mobrey Squitch 2. Ultrasonic Liquid Level Switch. Product Data Sheet February 2015 IP207, Rev DB

Flow measurement FlexFlow PF20S Flow sensor for industrial applications

PHOENIX CONTACT - 07/2006

Redundancy Module QUINT-DIODE/40

Product information. Guided Wave Radar. Level measurement in bulk solids VEGAFLEX 82 VEGAFLEX 86. Document ID: 46598

Safety switches with separate actuator

PI-EX-ME-2NAM/COC-24VDC

PHOENIX CONTACT - 12/2007

Operating Instructions for Level Switch for Liquids. Model: RFS

QUINT-BUFFER/24DC/24DC/40

SYSTEM COMPONENTS SYSTEM COMPONENTS MODULES

LMP 308. Separable Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO / 0.

Level measurement. Applications. Special features. Description

WirelessHART Adapter SWA70

Solid-state Timer. Ordering Information. Miniature Timer with Multiple Time Ranges and Multiple Operating Modes H3YN- - Accessories (Order Separately)

OPTIFLEX 1100 C Technical Datasheet

TERMOREG industrial automation CZ PRUSANKY 352, Czech republic tel.: , fax:

Installation Sensing distance Connection Output configuration Operation mode NO Operation mode NC

PI-EX-ME-2NAM/COC-120VAC

Silopilot M FMM50. Technical Information. Electromechanical Level Measuring System

RTU500 series Data Sheet Power Supply CP-E 24/2.5

Inductive sensor BI5-EM18-Y1X-H1141

QUINT-PS AC/24DC/10

Safety Control. FS1A Multi-function Safety Relay. Optional Parts. Connecting Tool. Marked Cable Tie. DIN Rail BNDN1000 Aluminum, 1m 35mm wide

Capacitive. Overview 116 VEGACAP series VEGACAP 27, 35, Capacitive VEGACAP

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

Transcription:

Technical Information TI 287F/00/en Capacitive Limit Detection minicap FTC 260, FTC 262 Compact switch for limit detection with active build-up compensation No calibration necessary Version available for dust explosion areas Applications Minicap is designed for limit detection of light bulk solids, e.g. grain products, flour, milk powder, animal feed, cement, chalk or gypsum. Versions: Minicap FTC 260 with 140 mm rod probe; for bulk solids and liquids Minicap FTC 262 with max. 6 m rope probe; for bulk solids Relay output (potential-free change-over contact / SPDT) with AC or DC power PNP output with three-wire DC power FTC 260 Features and Benefits Complete unit consisting of the probe and electronic insert: simple mounting no calibration on start-up Active build-up compensation accurate switch point even with heavy build-up on the probe high operational safety Mechanically rugged no wearing parts long operating life no maintenance The rope probe of the Minicap FTC 262 can be shortened optimum matching to the measuring point in the silo less stocks required FTC 262 Endress +Hauser The Power of Know How

Measuring System Minicap is an electronic switch. The complete measuring system consists of: the Minicap FTC 260 or FTC 262 a power supply and controllers, switching devices, signal transmitters (e.g. lamps, horns, PCS, PLC, etc.) FTC 262 Max. FTC 260 Min. FTC 260 Limit detection in silos containing solids Measuring Principle Factory setting on switches Table of application examples Grey background: Application limits of Minicap exceeded. Recommendation: Soliphant FTM to be used. In general: If the dielectric constant of the solid is not known, then the density (apparent weight) of the solid is a deciding factor. Under normal conditions the Minicap functions in foodstuffs with a density of 250 g/l and above or in plastic or mineral materials with a density of 600 g/l and above. Limit Detection A metal plate at the end of the probe, within the insulation, and the integrated counter-electrode together with the surroundings combine to form the two electrodes of a capacitor. If the probe is covered or free of material, then the capacitance changes and the Minicap switches. Maximum fail-safe LEDs Sensitivity MIN MAX A B C D 10.8V 45V DC + 1 2 3 1 2 3 FTC 262 DC PNP I max 200 ma Switch position Grain, seed, legumes and their products Examples ρ in g/l εr Function (approx.) (approx.) Rice Cornstarch (packed) Flour (wheat) Corn grist Sunflower seeds Noodles Bran (wheat) Popcorn 770 680 580 500 380 370 250 30 Minerals, inorganic materials Cement Plaster Chalk (packed) Chalk (loose) Plastics ABS granulate PA granulate PE granulate PVC powder PU dust 1050 730 540 360 630 620 560 550 80 3,0 2,6 2,4 2,1 1,9 1,9 1,7 1,1 2,2 1,8 1,6 1,4 1,7 1,7 1,5 1,4 1,1 no () no no no no Active Build-up Compensation The Minicap detects build-up on the probe and compensates for its effects so that the switch point is always accurate. The effects of build-up compensation depend on: the thickness of the build-up on the probe, conductivity of the material, the sensitivity setting on the electronic insert. Setting the Sensitivity The Minicap is so calibrated at the factory that it correctly switches in most cases. Greater sensitivity can be set using a multi-pole switch on the electronic insert. This is only necessary, however, if there is very strong build-up on the probe, or if the dielectric constant of the material ε r is very small. Function Range There is a loose relationship between the dielectric constant ε r and density ρ of the material. However, this depends on the solid. The table on the left indicates whether the Minicap can be used or if application limits are exceeded. 2

Minimum/Maximum Fail-Safe Mode The Minicap FTC 260 can be set to minimum or maximum fail-safe mode (see following table). AC or DC version with relay output (potential-free change-over contact): Maximum fail-safe mode: The relay is de-energised when the probe is covered or the power supply fails. Minimum fail-safe mode: The relay is de-energised when the probe is free or the power supply fails. DC version with PNP output: Maximum fail-safe mode: The switch output is blocked when the probe is covered or the power supply fails. Minimum fail-safe mode: The switch output is blocked when the probe is free or the power supply fails. Switch position Level Relay output Transistor SPDT output PNP Red LED for switching status Green LED for stand-by 1 3 4 5 L+ 3 Probe covered Relay de-energised blocked Maximum fail-safe mode 3 4 5 1 L+ 3 + Probe free Relay energised connected 3 4 5 1 L+ 3 + Probe covered Relay energised connected Minimum fail-safe mode 3 4 5 1 L+ 3 Probe free Relay de-energised blocked U 0 V Selecting the switch position and function Power failure 3 4 5 Relay de-energised 1 3 L+ blocked Installation Hints Silo Material The Minicap can be installed in a wide range of silos made of different materials (e.g. metal, plastic, concrete). Mounting Point Note the angle of the material mounds and the outlet funnel when determining the mounting point or probe length of the FTC 262. The Minicap switches when the probe tip is covered by a few centimeters of material or when it is free. Material flow should not be directed at the probe. 3

Installation Hints FTC 260 Max. 25 d) min. 200 a) max. 50 min. 1000 e) 200 200 200 b) f) max. 1400 N min. 200 Min. c) General information and recommendations for installing the Minicap FTC 260 limit switch Correct Incorrect Correct Installation a) Minimum distance: To prevent mutual interference with the FTC 260, the probes must be at least 200 mm from each other. b) Mounting point: The tip of the probes must point slightly downwards so that the material can slide off more easily. The protective cover protects the probe rod from collapsing mounds or mechanical strain at the outflow when the Minicap FTC 260 is set to minimum detection. c) Mechanical load: The maximum lateral load on the probe rod must be taken into account when used for minimum detection. It should therefore only be used for minimum detection with loose materials that have good flow characteristics. Incorrect Installation d) The probe can be damaged by the inflowing material and cause faulty switching. Cable gland pointed upwards can allow moisture to enter. e) Threaded socket too long with material build-up on the silo wall. (less than the minimum mounting depth of 100 mm). f) Mounted near build-up in the silo. The probe tip is too near to a silo wall (less than a minimum distance of 200 mm). 4

Installation Hints FTC 262 a) d) e) Max. min. 300 b) f) min. 300 max. 3000 N c) FTC 260 min. 300 g) Min. min. 200 max. 3000 N Correct Incorrect Correct Mounting a) Minimum distances: Sufficent distance from the material filling curtain and the other probe. b) Mounting point: Do not install in the centre of the outlet cone. Ensure there is sufficient distance from the silo wall and from material build-up on the wall. c) Mechanical load: Note the tensile strain on the probe rope and the strength of the silo roof when used for minimum detection. Very high tensile forces may occur at the material outlet especially with heavy, powdery bulk materials which tend to form build-up. These forces are significantly greater over the outlet than at the silo wall. Incorrect Mounting d) In the centre of the material outflow; the high tensile forces at this point may tear off the probe or damage the silo roof. e) The probe may be damaged by inflowing material. f) Mounted laterally g) Too near silo wall; when swinging gently the probe can hit the wall or touch any build-up which may have formed. This can result in error switching For minimum detection Minicap FTC 262 should only be used for light, easily flowing solids, and that do not tend to form build-up. 5

Electrical Connection To ensure that the Minicap operates safely and without electrical interference, it must be connected to an earthed silo with metal or reinforced concrete walls. For silos made of non-conductive materials, the external earth wire of the Minicap must be connected to a conductive and earthed component which is earthed near to the silo. The protective earth can be connected to the internal earth terminal of the Minicap. Connections can be made with standard instrument cabling. See TI 241F/00/en for information on EMC (testing procedures, installation). Connect the potential matching lead (PAL) when using in dust explosion hazardous areas. Note national regulations! 3 4 5 1 2 M Minicap AC or DC connection and relay output. EX E F1: Fine-wire fuse to protect the relay contact, dependent on the connected load F2: Fine-wire fuse, 500 ma M: Earth connection to silo or metal components on silo E: Earth No ground lines (PE) or potential matching lines (PAL) are required with Minicap FTC 260. F1 U~ max. 253 V/ 4 A max. 1000 VA, cos ϕ = 1 U... max. 30 V/ 4 A max. 253 V/ 0,2 A F2 L1 N PE or L+ L PAL U~ 20 253 V U... 20 55 V Minicap with three-cable DC connection; Transistor output PNP. F: Fine-wire fuse, 500 ma R: Connected load, e.g. PLC, PCS, relay M: Earth connection to silo or metal components on silo E: Earth Minicap is protected against reverse polarity. The green LED for standby goes out if the connections are reversed. F 1 2 3 + R max. 200 ma PAL EX E M No ground lines (PE) or potential matching lines (PAL) are required with Minicap FTC 260. L+ L PE U... 10,8 45 V 6

Technical Data General Information Manufacturer Endress+Hauser Instrument Limit switch Instrument designation Minicap FTC 260, FTC 262 Technical documentation Version TI 287F/00/en 04.00 Technical specifications DIN 19259 Application Material Solids, grain size max. 30 mm, dielectric constant ε r 1,6 Function and System Design Measurement principle Capacitive Measuring system Compact instrument Design With rod probe (FTC 260) or rope probe (FTC 262) Signal transmission Binary Input Measured variable Limit detection Measuring range FTC 260: ε r 1.6, FTC 262: ε r 1.5 Output Electronic insert DC, PNP transistor output Output signal Switching: PNP I max 200 ma overload and short circuit protection residual voltage at transistor at I max <2.9V Switching delay when free or covered FTC 260: 0.5 s FTC 262: 0,8 s AC / DC Relay output Contact: change-over, potential-free U~ max 253 V, I~ max 4 A (AC) P~ max 1000 VA, cos ϕ =1 P~ max 500 VA, cos ϕ >0,7 I max 4 A bis U 30 V (DC) I max 0,2 A bis U 253 V (DC) FTC260:0.5s FTC262:0,8s Power fail signal < 100 µa relay de-energised Overvoltage category Category III (EN 61010) Protection class to EN 61010-1 FTC 260: Class II, FTC 262: Class I Accuracy Reference conditions (for plastic vessels) Hysteresis Switch point Power up response Long-term drift Effect of material temperature Ambient temperature 23, operating temperature 23, operating pressure p e = 0 bar, material: dielectric constant ε r = 2.6, conductivity < 1 µs, sensitivity setting: C FTC 260 FTC 262 Horizontal 4 mm, Vertical 7 mm Vertical 5 mm Horizontal: centre of probe 5 mm Vertical: 40 mm above probe tip Vertical: 35 mm above probe tip Correct switching after max. 1.5 s Correct switching after max. 2 s Horizontal 3 mm, Vertical 6 mm Vertical 6 mm Depending on material to be measured Depending on material to be measured 7

Operating conditions Installation Orientation See section Installation Hints. T1 T1 80 40 40 80 120 80 40 40 80 120 T1 80 70 FTC 260 FTC 262 EX EX EX T2 T2 Environment Operating temperature range T 1 +70 (0 +160 F) [ +60, Dust-Ex version] Operating temperature limits +80 ( +180 F) [ +60, Dust-Ex version] Storage temperature +80 ( +180 F) Climate class IEC 68 part 2-38 Ingress protection IP 66 Shock resistance Probe: 7 J Vibrational resistance EN 60068-2-64 (IEC 68-2-64), 20 2000 Hz, spectral rate of velocity 0,5, 100 min per axis Electromagnetic compatibility Interference Emission to EN 61326, Electrical Equipment Class B Interference Immunity to EN 61326, Annex A (Industrial) and NAMUR Recommendation NE 21 (EMC) See TI 241F/00/en for general instructions regarding the EMC test conditions for E+H instruments. 80 70 T2 Medium FTC 260 FTC 262 T1 80 60 80 70 EX T2 Process temperature range T 2 +120 ( +250 F) +70 (0 +160 F) ( +80, Dust-Ex version) Process temperature limits +130 ( +270 F) +80 ( +180 F) ( +80, Dust-Ex version) Process pressure range p e 1 +25 bar ( 14,5 +360 psi) 1 +6 bar ( 14,5 +90 psi) Mechanical construction Housing Housing F 14 Polter PBT-FR, IP 66 Process connections FTC 260 FTC 262 Threaded boss 1 BSPT (R 1, ISO 7/1); Adapter for 1½ BSPT and 1½ BSP (G 1½) see accessories 1½ BSPT (R 1½, ISO 7/1) 1 NPT, ANSI B 1.20.1, Adapter; for 1¼ NPT see accessories 1½ NPT, ANSI B 1.20.1 F N 3000 2800 0 +40 +80 T2 Material for wetted parts Probe rod FTC 260 PPS = Polyphenylene sulphide (glass fibre content approx. 40%) Probe length FTC 260: 140 mm (5.5 in), FTC 262: min. 500 mm (20 in), max. 6000 mm (236 in) Flexural strength FTC 260 1400 N (at probe tip) Probe rope FTC 262 Surface in High Density PE over steel coating Other probe parts FTC 262 PPS = Polyphenylene sulphide (glass fibre content approx. 40 %) Tensile strength F of FTC 262 Max. 3000 N up to 40, max 2800 N at 80 User interface Display Green LED: stand-by Red LED: switch status Operation Switch on electronic insert: switching between minimum and maximum fail-safe mode sensitivity setting (depends on the dielectric constant ε r and build-up). A sensitivity adjustment is normally not required (see section Operating Principle ) 8

Power supply Electronic insert DC, PNP transistor output Supply voltage U... 10,8 45 V (DC), transient pulses to 55 V, current consumption max. 30 ma, reverse polarity protected Electrical connection AC / DC Relay output Terminals: wires max. 1.5 mm² in end sleeves, wire max. 2.5 mm² U~ 20 253 V (AC) or U... 20 55 V (DC), current consumption max. 130 ma Certificates and approvals ATEX, FM, CSA Overspill protection FTC 260 CE Mark See section Product Structure DIBt, General design approval In attaching the CE Mark, Endress+Hauser confirms that the device conforms to all relevant EU directives. Ordering Limit switch Minicap FTC 260, FTC 262 see Product Structure Accessories Adapter for FTC 260: 1 BSPT female (R c 1) ISO 7/1 (see dimensional sketch) Adapter for FTC 260: 1 NPT female Transparent cover for FTC 260/262 For 1½ BSPT (R 1½ ISO 7/1, PPS) Part No.: 943215-1001 For 1½ BSP (G 1½ DIN ISO 228, PPS Part No.: 943215-1021 For 1¼ NPT, steel Part No.: 943215-0042 For 1¼ NPT, AISI 316 Ti (1.4571) Part No.: 943215-0043 Part No.: 943201-1001 Rope shortening set for FTC 262 Part No.: 52005918 (not for Dust-Ex) (not for CSA) Supplementary documentation Operating manual for FTC 260 Operating manual for FTC 262 Operating manual for rope shortening set for FTC 262 Safety instructions (ATEX) for FTC 260 Safety instructions (ATEX) for FTC 262 KA 093F/00/a6 Part No.: 017476-0000 KA 155F/00/a6 Part No.: 52005985 KA 157F/00/a6 Part No.: 52005986 XA 011F/00/a6 Part No.: 52000928 XA 092F/00/a3 Part No.: 52005988 II 1/3 D II 1/3 D 9

Dimensions ø94 ø94 max. 100 max. 100 ~90 SW 41 AF 41 ~95 SW 50 AF 50 1 NPT R1 ~20 1½ NPT R1½ ~25 (1 BSPT) (1½BSPT) 32 Lmin. 500, Lmax. 6000 140 78 ø8 max. ø42 Minicap FTC 260 ~270 PPS SW 55 32 40 R 1½ / G 1½ (1½ BSPT / 1½ BSP) Adapter for FTC 260 Minicap FTC 262 Dimensions in mm 100 mm = 3.94 in Probe length tolerances: Probe length L Tolerance Max. 1000 mm +0, 10 mm Max. 3000 mm +0, 20 mm Max. 6000 mm +0, 30 mm 10

Product Structure Minicap FTC 260 Limit switch with rod probe Certificates and Approvals A Versions for non-ex areas B BVS, Zone 10, ATEX II 1/3 D D Overspill protection to WHG J FM DIP, Cl. II, III, Groups E-G, T5 S CSA DIP, Cl. II, Groups E-G, Cl. III U CSA General Purpose Y Special version Process Connection A 1 BSPT threaded boss, (R 1, ISO 7/1) B 1 NPT threaded boss, ANSI B 1.20.1 Y Other Electronic Insert 2 DC connection 10.8 45 V, Transistor output PNP 4 Universal connection, U~: 20 253 V (AC), U : 20 55 V (DC) Relay output, potential-free change-over contact (SPDT) 9 Other Housing and Cable Entry A Polter F14, IP 66, Pg 13.5 B Polter F14, IP 66, ½ NPT C Polter F14, IP 66, G ½ D Polter F14, IP 66, M 20x1.5 Y Other Additional Equipment 1 None 2 Transparent cover 9 Other Minicap FTC 260 FTC260 Product designation Weight 0.56 kg (1.23 lbs) Minicap FTC 262 Limit switch with robe probe Minicap FTC 262 Basic weight: For probe lengths 500 mm (20 in) Please state probe length required in millimeters or inches FTC262 Certificates and Approvals A Versions for non-ex areas B ATEX II 1/3 D J FM DIP, Cl. II, III, Groups E-G S CSA DIP, Cl. II, Group G and coal dust, Cl. III U CSA General Purpose Y Special version Process Connection Weight A 1½ BSPT threaded boss, (R 1½, ISO 7/1) Basic weight 1.23 kg B 1½ NPT threaded boss, ANSI B 1.20.1 Basic weight 1.23 kg Y Other Probe Length L (Rope shortening not allowed for CSA) 1 Variable in mm (500 mm 6000 mm) Additional weight 0.07 kg/1000 mm 2 Variable in inch (20 in 236 in) Additional weight 0.18 kg/ 100 in 3 1500 mm ( 59 in) Total weight 1.30 kg 4 2500 mm ( 98 in) Total weight 1.37 kg 5 4000 mm (157 in) Total weight 1.48 kg 6 6000 mm (236 in) Total weight 1.62 kg Electronic Insert 2 DC connection 10.8 45 V, Transistor output PNP 4 Universal connection, U~: 20 253 V (AC), U : 20 55 V (DC) Relay output, potential-free change-over contact 9 Other Housing and Cable Entry A Polter F14, IP 66, Pg 13,5 B Polter F14, IP 66, ½ NPT C Polter F14, IP 66, G ½ D Polter F14, IP 66, M 20x1.5 Y Other Additional Equipment 1 None 2 Transparent cover 9 Other Product designation Total weight kg (1 kg = 2.2 lbs) 11

Endress+Hauser GmbH+Co. Instruments International P.O. Box 2222 D-79574 Weil am Rhein Germany Tel. (07621) 9 75-02 Tx 773926 Fax (07621) 975-345 http://www.endress.com info@ii.endress.com Endress +Hauser The Power of Know How 08.99/MTM TI 287F/00/en/01.01 EHF/CV5