ABB 520BID01 Binary Input datasheet

Similar documents
Analog output 520AOD01 Data sheet

Binary output and supervision 520CSD01 Data sheet

DIN Rail RTU 540CMD01 Data sheet

Analog input 520AID01 Connections and settings

I/O adapter 520ADD03 Connections and settings

Binary output 520BOD01 Connections and settings

RTU511. Binary Output 23BO62. Characteristics. Application. Data Sheet Binary Output 23BO62. The binary output is made via relay contacts.

Switch 560NMS34 Data sheet

Switch 560NMD01 Data sheet

Switch 560NMD11 Data sheet

Application. Characteristics RTU540. Data Sheet Communication Unit 560CMD11. Communication Unit 560CMD11

Electronic timer CT-EBD.12 Flasher starting with ON with 1 c/o (SPDT) contact

Electronic timer CT-SDD.22 Star-delta change-over with 2 n/o contacts

Switching relay CT-IRE with 1 c/o (SPDT) contact

Electronic timer CT-ARE OFF-delayed without auxiliary voltage, 1 c/o (SPDT) contact

NI REM Remote I/O Overview DATASHEET. Digital Input Module for Remote I/O

Application. Characteristics RTU560. Data Sheet Communication Unit 560CMD11. Communication Unit 560CMD11

DI572 Digital Input Module

NI REM Remote I/O Overview DATASHEET. Digital Output Module for Remote I/O

Characteristics. Application RTU560. DIN Rail RTU 560CIG10. Data Sheet DIN Rail RTU 560CIG10

DI561 Digital Input Module

TM3DI16G module TM3-16 inputs spring

Application. Characteristics RTU560. DIN Rail RTU 560CIG10. Data Sheet DIN Rail RTU 560CIG10

RE22R1QMQ star-delta timing relay - 230VAC/440VAC - 1 C/ O

RE17LAMW on-delay timing relay - 1 s..100 h V AC/ DC - solid state output

RE22R1QMQ star-delta timing relay - 230VAC/440VAC - 1 C/O

DC562, digital input/output module,

DC561, digital input/output module,

RE17LAMW on-delay timing relay - 1 s..100 h V AC/DC - solid state output

TU531, TU532 Terminal Unit

Electronic timer CT-APS.21 OFF-delayed with 2 c/o (SPDT) contacts

RTU560. CT/VT Interface 560CVT10. Meter Operation. Application. Characteristics. Data Sheet CT/VT Interface 560CVT10. Instantaneous Meter Values

RTU500 series Data Sheet Power Supply CP-E 24/2.5

DX561 Digital Input/Output Module

RE17LCBM off-delay timing relay - control - 1 s..100 h V - solid state output

Electronic timer CT-ERS.12 ON-delayed with 1 c/o (SPDT) contact

NI REM Remote I/O Overview DATASHEET. Analog Output Module for Remote I/O

TM3DI16 module TM3-16 inputs

Voltage monitoring relays CM-ESS.1 For single-phase AC/DC voltages

AI561 Analog Input Module

Control Panel CP600-eCo CP604, CP604-B

TF501, TF521 Terminal Bases

RE22R2AMR On-delay Timing Relay s 300h V AC/DC - 2C/O

RE22R2CMR Off-delay Timing Relay s 300h V AC/DC - 2C/O

TM241CE24T controller M IO transistor PNP Ethernet

Control Panel CP600 CP651, CP651-WEB

RE22R2QGMR Star-Delta Timing Relay s 300h V AC/DC - 2C/O

CU-ADP2/CU-ADP2.1/CU-ADP3

Characteristics. Application RTU560. HMI unit 560HMR01. Data Sheet HMI unit 560HMR01

NI REM Remote I/O Overview DATASHEET. Bus Coupler for Remote I/O

Electronic timer CT-ARS.11 OFF-delayed without auxiliary voltage with 1 c/o (SPDT) contact

TM241C40U controller M IO transistor NPN

TM241C24T controller M IO transistor PNP

AO523 Analog Input Module

Part No. Description Product Life Cycle Phase *) unit, 24 VDC, spring terminals. unit, 24 VDC, spring terminals, XC version

RE11RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

Electronic timer CT-SDS.23 Star-delta change-over with 2 n/o contacts

RE22R2AMR On-delay Timing Relay s 300h V AC/DC - 2C/O

Control Panel CP600 CP635, CP635-B, CP635-WEB

TM5C12D6T6L compact I/O expansion block TM5-24 I/0-12 DI - 6 DO transistor - 4 AI - 2 AO

RE22R2KMR Off-delay Timing Relay s 10min V AC/DC - 2C/O

Messaging module CP-C MM

TM3AI4 module TM3-4 analog inputs

Redundancy unit CP-D RU Accessory for CP range power supplies (e.g. switch mode power supplies CP-D range)

Electronic timer CT-ARS.21 OFF-delayed without auxiliary voltage with 2 c/o (SPDT) contacts

TM3TI4 module TM3-4 inputs temperature

AO561 Analog Output Module

TM221M16R controller M IO relay

TM241C40R controller M IO relay

02/11/2015

TM221CE40T controller M IO transistor PNP Ethernet

TM241CE40R controller M IO relay Ethernet

RE22R2QTMR Star-Delta Timing Relay s 300h V AC/DC - 2C/O

Relion 611 series. 611 series Type Test Certificate

ILBPB24DO32. Inline Block IO Module for PROFIBUS With 32 Digital Outputs. AUTOMATIONWORX Data Sheet 6889_en_04. Description

Electronic timer CT-ARS.21 OFF-delayed without auxiliary voltage with 2 c/o (SPDT) contacts

FL MC 2000E (SM40) LC

TM3TI4 module TM3-4 inputs temperature

TM241CE24U controller M IO transistor NPN Ethernet

PHOENIX CONTACT - 07/2006

Thermistor motor protection relays CM-MSS.12 and CM-MSS.13

TM3SAF. Main. Device short name

Control Panel CP600 CP635-FB, CP635-FW

TM241C24R. Main. Discrete output type. Discrete output number. 14 (remote I/O architecture) 50 µs turn-on operation with I0...I13 terminal(s) input

02/11/2015

Thermistor motor protection relays CM-MSS.12 and CM-MSS.13

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23

TM3TI8T module TM3-8 inputs temperature

RE22R1AMR On-delay Timing Relay s 300h V AC/DC - 1C/O

CM592 PROFIBUS Communication Module

TM221CE24R controller M IO relay Ethernet

08/07/2015

Electronic timer CT-AHD.22

ILBIB24DO16-DSUB. Inline Block IO Module for INTERBUS With 16 Digital Outputs; Bus Connection via D-SUB Connectors

TM221M16TG controller M IO transistor PNP spring

TM221ME32TK controller M IO transistor PNP Ethernet

IB ST 24 AO 4/EF. INTERBUS-ST analog output module, 4 outputs, 0-10 V, ±10 V, 0-20 ma, 4-20 ma. Data sheet. 1 Description

Bus Connection Unit 560BCU04

TM3TM3 module TM3-2 temperature inputs and 1 analog output

Transcription:

ABB 520BID01 Binary Input datasheet http://www.manuallib.com/abb/520bid01-binary-input-datasheet.html The binary input module 520BID01 provides 16 galvanic isolated inputs for up to 16 binary process signals. Scanning and processing of the inputs are executed with the high time resolution of 1 ms. The allocation of an input signal to the processing functions can be done according to the rules of configuration. ManualLib.com collects and classifies the global product instrunction manuals to help users access anytime and anywhere, helping users make better use of products. http://www.manuallib.com

RTU520 product line Binary Input 520BID01 Data sheet.. I1 I01 C01 I2 I02 I3 I03 I4 I04 ST I5 I6 I05 I06 Microcontroller I7 I07 RTU I/O bus RAM Flash Input register I8 I9 I08 I09 C02 IOC I10 I11 I10 I11 I12 I12 I13 I13 I14 I14 I15 I15 I16 I16 Application The binary input module 520BID01 provides 16 galvanic isolated inputs for up to 16 binary process signals. Scanning and processing of the inputs are executed with the high time resolution of 1 ms. The allocation of an input signal to the processing functions can be done according to the rules of configuration. The module 520BID01 is able to process the following types of signals: 16 single indications with time stamp 8 double indications with time stamp 2 digital measured values each with 8 bit 1 digital measured value with 16 bit 16 integrated totals (max. 25 Hz) 2 step position information each with 8 bit 2 bit string information each with 8 bit 1 bit string information with 16 bit The module is available in two versions (rubrics): 520BID01 R0001: process voltage 24 to 60 V DC. LED signaling for each input, common return per 8 inputs. 520BID01 R0002: process voltage 110 to 125 V DC. LED signaling for each input, common return per 8 inputs. Figure 1: Block diagram 520BID01 Characteristics Binary inputs The inputs are galvanic isolated by means of optical couplers. 8 inputs are building a group with a common return. The binary input channels are protected against reverse voltage installation. If the input signal is installed with wrong polarity the input current will be zero. The module has 16 LEDs to indicate the signal state at the inputs. The LEDs are switched by the controller. The maximum permissible frequency for counter pulses is 25 Hz. Power supply input The required power for the module is supplied via the RTU520 I/ O bus connector.

I/O controller (IOC) The micro-controller on the module processes all time critical tasks of the parameterized processing functions. Moreover it carries out the interactive communication with the RTU I/O bus. All configuration data and processing parameters are loaded by the communication unit via the RTU I/O bus. In connection with an I/O adapter (e. g. 520ADD01) or the RTU520 communication unit the module has a connection to the RTU520 I/O bus (wired OR-bus). The binary input unit can execute the following processing functions for the different types of signals: Digital filtering to suppress contact bounce Suppression of oscillating signals caused by the process Validity check and suppression of intermediate input states for double indications Validity check for all channels allocated to digital measured values Summation of increment pulses to form integrated totals in registers of 31 bit resolution Copying of integrated totals values into freezing registers on request for data conservation The module provides a data buffer for temporally storing of up to 50 event messages including time stamps. The events are stored in chronological order designated for transmission to the communication unit (CMU). During initialization and operation the module carries out a number of tests. If a fault occurs it is reported to the communication unit. All fault conditions impairing the function of the module are displayed as common fault signal by a red LED. A failure of the module is detected by the communication unit. 2 1KGT 150 862 V002 1 - Binary Input 520BID01

Technical data In addition to the RTU500 series general technical data, the following applies: Input channels 520BID01 R0001 Inputs 16 channels, common return for 2 groups of 8 channels, isolated by opto-couplers Nominal input voltage 24... 60 V DC (+/- 20%) Max. input voltage 72 V DC Mechanical layout Mounting Weight Connection type Process connector DIN rail mounting EN 50022 TS35: 35 mm x 15 mm or 35 mm x 7.5 mm 0.15 kg 2 x 10 pole 5.08 mm pluggable spring terminals (included in delivery) 0.2... 2.5 mm²/ AWG 24 - AWG 12 Input current Logical 1 definitely detected Logical 0 definitely detected 1.5... 5 ma 18 V DC 9 V DC Insulation tests AC test voltage IEC 61000-4-16 2.5 kv, 50 Hz Test duration: 1 min Reverse voltage protection yes IEC 60870-2-1 (class VW3) Impulse voltage withstand test 5 kv (1.2 / 50 µs) Input channels 520BID01 R0002 Inputs 16 channels, common return for 2 groups of 8 channels, IEC 60255-5 IEC 60870-2-1 (class VW 3) Insulation resistance IEC 60255-5 > 100 MΩ at 500 V DC isolated by opto-couplers Nominal input voltage 110... 125 V DC (+/- 20%) Max. input voltage 150 V DC Input current 1.2... 2 ma Logical 1 definitely detected 85 V DC Logical 0 definitely detected 45 V DC Reverse voltage protection yes Current consumption for power supplied via WRB bus 5 V DC 50 ma 15 V DC -- 18 V DC -- 24 V DC -- Signaling by LEDs Immunity test Electrostatic discharge IEC 61000-4-2 Radiated Radio-Frequency Electromagnetic Field IEC 61000-4-3 Electrical Fast Transient / Burst IEC 61000-4-4 Surge IEC 61000-4-5 Conducted Disturbances, induced by Radio-Frequency Fields IEC 61000-4-6 Damped oscillatory wave IEC 61000-4-18 8 kv air / 6 kv contact (level 3) 10 V/m (level 3) 4 kv (level X) 4 kv (level 4) 10 V (level 3) 2.5 / 1 kv (level 3) ERR (red) Common fault information for the module CH1 CH16 LED displays the active inputs Environmental conditions Nominal operating temperature range: -25... +70 C Mechanical layout Dimensions Housing type 35 mm x 98 mm x 117 mm (Width x Hight x Depth) Plastic housing (V-0), RAL 7035 light gray Start up: Max. operating temperature, max. 96h: EN 60068-2-1, -2-2, -2-14 Relative humidity EN 60068-2-30-40 C +85 C 5... 95 % (non condensing) Binary Input 520BID01-1KGT 150 862 V002 1 3

Ordering information 520BID01 R0001 520BID01 R0002 1KGT033200R0001 1KGT033200R0002 4 1KGT 150 862 V002 1 - Binary Input 520BID01

Contact us ABB AG Power Systems Division P.O. Box 10 03 51 68128 Mannheim, Germany www.abb.com/substationautomation Note: The specifications, data, design or other information contained in this document (the Brochure ) - together: the Information - shall only be for information purposes and shall in no respect be binding. The Brochure does not claim to be exhaustive. Technical data in the Information are only approximate figures. We reserve the right at any time to make technical changes or modify the contents of this document without prior notice. The user shall be solely responsible for the use of any application example or information described within this document. The described examples and solutions are examples only and do not represent any comprehensive or complete solution. The user shall determine at its sole discretion, or as the case may be, customize, program or add value to the ABB products including software by creating solutions for the end customer and to assess whether and to what extent the products are suitable and need to be adjusted or customized. 1KGT 150 862 V002 1 This product is designed to be connected to and to communicate information and data via a network interface. It is the users sole responsibility to provide and continuously ensure a secure connection between the product and users or end customers network or any other network (as the case may be). The user shall establish and maintain any appropriate measures (such as but not limited to the installation of firewalls, application of authentication measures, encryption of data, installation of anti-virus programs, etc) to protect the product, the network, its system and the interface against any kind of security breaches, unauthorized access, interference, intrusion, leakage and/or theft of data or information. ABB AG is not liable for any damages and/or losses related to such security breaches, any unauthorized access, interference, intrusion, leakage and/or theft of data or information. ABB AG shall be under no warranty whatsoever whether express or implied and assumes no responsibility for the information contained in this document or for any errors that may appear in this document. ABB AG's liability under or in connection with this Brochure or the files included within the Brochure, irrespective of the legal ground towards any person or entity, to which the Brochure has been made available, in view of any damages including costs or losses shall be excluded. In particular ABB AG shall in no event be liable for any indirect, consequential or special damages, such as but not limited to loss of profit, loss of production, loss of revenue, loss of data, loss of use, loss of earnings, cost of capital or cost connected with an interruption of business or operation, third party claims. The exclusion of liability shall not apply in the case of intention or gross negligence. The present declaration shall be governed by and construed in accordance with the laws of Switzerland under exclusion of its conflict of laws rules and of the Vienna Convention on the International Sale of Goods (CISG). ABB AG reserves all rights in particular copyrights and other intellectual property rights. Any reproduction, disclosure to third parties or utilization of its contents - in whole or in part - is not permitted without the prior written consent of ABB AG. Copyright ABB 2014 All rights reserved