Leading LED Applications. XD6/XD10 User Manual

Similar documents
Obtaining Documentation and Submitting a Service Request, page xvii Safety Warnings, page xvii Safety Guidelines, page xx

Installation Job Aid for Ethernet Routing Switch 3600 Series

dv/dt filter compact plus Voltage Peak Limiter SINAMICS SINAMICS G120P dv/dt filter compact plus Voltage Peak Limiter Safety information 1 General 2

User Manual Black OnyX3

User s Manual (Model A) isappos 9/12 Stand

LED Colour Flood 10W / 30W RGB LED floodlight. user manual

Line reactors SINAMICS. SINAMICS G130 Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation

TURBO HD TVI Bullet & Turret Camera

User Manual 1. Linx-37 User Manual

SINAMICS. SINAMICS G120P dv/dt filter plus Voltage Peak Limiter. Safety information 1. General. Mechanical installation. Electrical installation 4

To connect the AC adapter:

Users Manual STP-103II. Thermal Printer Rev

DPX-620III 6-Ch. dimmer pack. user manual

User Manual Dot-D75/D150

650/1000 Fresnel 650/1000 PC 300/500 Antihalo 300/500 Fresnel theatre spotlight. user manual

ROE Strip User Manual

LVN5200A-R2, rev. 1, Hardware Installation Guide

DT1102 V (PS) Fully Configurable Galvanic Isolator. Operating Instructions

xbrick Full-Colour 16 3W LED floodlight user manual

D610H, D610H MKII, D610S, D610T dimmer pack. user manual

HP UPS R/T3000 ERM. Overview. Precautions. Installation Instructions

DOT MATRIX PRINTER SP6000 SERIES

EVO-TM2A EVO-TM2B Touch Screen Monitor

Blitzer Strobe. User Manual. Order code: EQLED366

Agilent 34401A 6½ 桁マルチメータ ユーザーガイド

Installation Job Aid for VSP 4850GTS

BS 287 DUAL CHANNEL POWER SUPPLY. User Manual. January 2017 V1.0

Preparing to Install the VG248

Installation Job Aid for VSP 4450GTX-HT- PWR+

UV Power Flood. User Manual. Order code: EQLED029

LED Pixel Rail 40 RGB LED strip. user manual

DMX Splitter 4 MKIII 19" DMX splitter. user manual

D1210H dimmer pack. user manual

Network Camera. Quick Guide DC-D1223WX. Powered by

CS2 DMX Distribution Splitter

Line reactors SINAMICS. SINAMICS G120P Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation 4

LED W RGBA User Manual

LED Maintenance Instructions

Gobo Projector XP 80W

DC-D4213RX DC-D4213WRX

Installation Job Aid for Ethernet Routing Switch 5900 Series

Crossfire. User Manual. Order code: EQLED061

i-mira LED Digital Framed Poster

INSTRUCTION MANUAL. * Design and Specifications are subject to change without notice. ver. 1.0 PRINTED IN KOREA

PF LED Profile. User Manual

PS/IO Circuit Board Retrofit

PAR56 10MM UV LED PAR. user manual

DC-D2212R / DC-D2212WR

User Manual. Stoltzen SHSP14 HDMI Splitter 1x4. 4K HDMI Splitter 1x4. All Rights Reserved. Version: SHSP14_2016V2

ZF LED Zoom Fresnel. User Manual

ILUMEN PID SOLUTION INDOOR OUTDOOR ILUMEN PIDBOX MINI INSTALLATION MANUAL. Ilumen PIDbox mini Version 1.5

Network Camera. Quick Guide DC-B1203X. Powered by

Instruction Manual. 2in1 LAN Tester & Multimeter. Model: 57314

MDM 011-Z1 Regen Resistor

Pixel Panel 144 RGB effect panel. user manual

User Manual TL-DA14-HD2 1x4 HDMI Splitter & Distribution Amplifier All Rights Reserved Version: TL-DA14-HD2_160926

TA18 active subwoofer. user manual

Assembly and Setup Manual

Outdoor Stage PAR 12 3W Tri LED-PAR. user manual

DS-1H05 Ethernet-over-Coax Extender. User Manual

Table of Contents Product Overview Before using the product Installation Procedure... 5

RevueLED 150 Profile 3200K 26 LED spotlight. user manual

LED PANEL. User Manual Please read the instructions carefully before use LED-7TC. Innovation, Quality, Performance 15-

3-Phase, Dual-Input 6-Slot Power Supply System STARTUP GUIDE

TPC25 active crossover. user manual

Advidia A-15 & A-35 Installation Manual

Table of Contents Quick Install Guide page Introduction Safety Rack System Precautions ESD Precautions...

NIR Moisture Analyzer KB-30

UP-1-1 Channel Dimmer. User manual. dimmer pack

LED Profile 150W 3200K. User manual. LED spotlight

Thanks for shopping with Improvements! Lighted Canterbury Christmas Greenery Doorway Arch Item #548443

DDS-405 LC DMX 4 Ch. Dimmer dimmer pack. user manual

Installation of the POTS splitter card requires the following steps: Determining the cables you need. Installing the POTS splitter chassis

icore Kiosk system Installation Guide

INFORMATION AMPLIFIER TA-102 OPERATING INSTRUCTIONS TABLE OF CONTENTS

Blitzer RGB Strobe. User Manual. Order code: EQLED365

The following symbols are used to show dangerous operation or handling. Make sure you understand them before reading the guide.

LED PANEL. User Manual Please read the instructions carefully before use LED-212RGB TABLE OF CONTENTS. 1. Safety Instructions

Installation Manual. Mounting Instructions Mechanical Mounting. Luminato. Teleste Corporation

UP-1-1 Channel Dimmer dimmer pack. user manual

QIT600F1 USER'S GUIDE

Optional add-on cassette Attachment Instruction manual

Two-door Access Controller

Line filter SINAMICS. SINAMICS G130 Line filter. Safety information 1. General 2. Mechanical installation 3. Electrical installation 4

MOBILE CONNECTOR - GEN 2 OWNER'S MANUAL

Achat 110 MA active full-range speaker. user manual

DM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER

FR-A8AR INSTRUCTION MANUAL

LXEM145 SERIES Lanx Australis single Phase KWh Meter 45Amp. User manual

Microbar COB System. User Manual. Order code: EQLED137

User s Manual. MON-121 Series TFT monitor. Models

DDS 405 digital dimmer and switcher. user manual

Analog Monitor Installation Manual

User Manual SP2-4K. 4K HDMI Splitter 1x2. All Rights Reserved. Version: SP2-4K_2016V1.0

A120 A W/240W PA Mixer-Amplifier 70V/100V

RevueLED 120 COB DMX LED spotlight. user manual

LED Theater Spot K. User manual. LED spotlight

Replacing the Power Supply

Cheetah Light LLC. (214) Instruction Manual

INSTALLATION INSTRUCTIONS

Transcription:

Leading LED Applications XD6/XD10 User Manual

Table of Contents 1. Product Introduction 2. Product Components 3. Product Installation 4. Product Wiring 5. Maintenance

Safety information WARNING! Please read the Safety Measures listed in this section carefully before installing, switching on, operating and maintenance of this product. The following marks on the product and in this manual indicate important safety measures. WARNING! Safety Risk! Might cause equipment damage Or safety risk WARNING! Please read the manual before operating WARNING! Dangerous Voltage! Might cause equipment damage or electric shock WARNING! Hot Surface! Do not touch WARNING! Flammable! WARNING! Possible damage to eyes Warning: Be sure to understand and follow all safety guidelines, safety instructions, warnings and precautions listed in this manual. This product is for professionals use only! This product may result in serious injury or death due to fire hazard, electric shock or on dropping. Please read this manual carefully before installing, powering up, operating and maintenance of this product. Follow safety instructions in this manual and on the product. If you have any questions, please seek help from Absen. Beware of Electric Shock! To prevent electric shock the device must be properly grounded during installation. Do not ignore using the grounding plug, or else there is a risk of electric shock. During a lightning storm, please disconnect the device s power supply, or provide other suitable lightning protection. If the equipment is not in use for a long time, please unplug the power cord. When performing any installation or maintenance work (e.g. removing the fuses, etc.,) make sure to turn off the master switch. Disconnect AC power when the product is not in use, or before disassembling, or installing the product. The AC power used in this product must comply with local building and electrical codes, and should be equipped with overload and ground fault protection. The main power switch should be installed at a location near the product and should be clearly visible and easily reached. This way in case of any failure the power can be promptly disconnected. Before using this product check all electrical distribution equipment, cables and all connected devices, and make sure all meet current requirements. Use appropriate power cords. Please select the appropriate power cord according to the required power and current capacity, and ensure the power cord is not damaged, aged or wet. If any overheating occurs, replace power cord immediately. For any other questions, please consult a professional.

Beware of Fire! Use a circuit breaker or fuse protection to avoid fire caused by power supply cables overloading. To avoid fire caused by power supply cables overloading, do not connect to the same power supply point for more than 4 cabinets at a voltage of 100-120V, or 8 cabinets at a voltage of 200-240V. Maintain good ventilation around the display screen, controller, power supply and other devices, and keep a minimum 0.1 meter gap with other objects. Do not stick or hang anything on the screen. Do not modify the product, do not add or remove parts. Do not use the product in case ambient temperature is over 55. Beware of Injury! Warning: Wear a helmet to avoid injury. Ensure any structures used to support, fix and connect the equipment can withstand at least 10 times the weight of all the equipment. When stacking products, please hold products firmly to prevent tipping or falling. Ensure all components and steel frames are securely installed. When installing, repairing, or moving the product, ensure the working area is free of obstacles, and ensure the working platform is securely and stably fixed. In the absence of proper eye protection, please do not look directly at the lit screen from within a 1 meter distance. Do not use any optical devices that have converging functions to look at the screen to avoid burning the eyes. WARNING: Beware of suspended loads. LED lamps used in the module are sensitive and can be damaged by ESD (electrostatic discharge). To prevent damage to LED lamps, do not touch when the device is running or switched off. WARNING: The manufacturer shall not bear any responsibility for any incorrect, inappropriate, irresponsible or unsafe system installation. Product Disposal Any component that has a recycling bin label can be recycled. For more information on collecting, reusing and recycling, please contact the local or regional waste management unit. Please contact us directly for detailed environmental performance information.

Product Introduction About the product The series are a breakthrough from traditional products, innovatively using independent waterproof modules, and designed with smart monitoring system. The products support front and rear installation and maintenance, have a simple design, excellent display effect, high stability, and provide easy and convenient installation and maintenance.

Product Specifications Parameter XD6 XD10 Pixel Configuration SMD2727 Pixel Pitch (mm) 6.66 10 Pixel matrix per panel 96 144 64 96 Physical Parameter Module Dimensions (LxW)/(mm) 320 320 Panel Dimensions (LxWxH)/(mm) 640 960 106 Panel material Aluminum Panel weight (kg) 21 Electronic Parameter Color Grayscale (Bit) 16 Refresh Rate(Hz) 1920 3840 Driving Type 1/6 1/2 Brightness(cd/m 2 ) 6000 Optical Parameter Color Temperature(K) 7500 Color Contrast 7000:1 6500:1 Viewing Angle (H/V) ( ) 160/100 160/110 AC Input Voltage(V) 100~240 Electrical Parameter Power Consumption Max.(W/m²) 630 660 Power Consumption Avg.(W/m²) 210 220 Storage Temperature( ) - 40~ + 60 Operating Temperature( ) - 20~ + 50 Circumstan ce Parameter Storage Humidity(RH) Operating Humidity(RH) IP rating (Front/Rear) 10 % ~90 % 10 % ~90 % IP65/IP54 Lifetime Typical Value(hrs) 100000 Key Product Selling Points Panel weight is only 21kg, easy delivery and installation Panel thickness is 106mm,saving your installation space. Without any monitoring card and data wire can realize monitor display working

status, realtime to monitoring sending card, receiving card, module, module connection, temperature,voltage& etc. Smart Modules: Module can store ID number, production date, order information, usage duration, color coordinates, current and other information. More convenient and practical.front and Rear cabinet installation: Convenient front installation design ensures screen maintenance without servicing channel at the back, saving space. Built-in standard mounting holes ensures easy rear installation. Front & Rear maintenance design for individual components: modules, controlling cards and power unit. External test button, enables simple test just by pressing the button. No cables design, simple and convenient, saving cost. Module data and power supply adopt parallel connecting, one module failure, will not effect others. Adopt SMD2727 LED, higher contrast ratio, XD6 5000:1, XD10 6500:1.

Product Dimensions Product Components Cabinet Introduction

Installation hole Distribution box Positioning Column Handle Test button Module Distribution box loc Modules

Packaging Carton Packing Wooden case packing Note: Wooden packing is recommended for long-distance transportation. Installation-use connecting plates and bolts Connecting plates M8x10 Bolt Product Installation Installation Types Outdoor fixed mounted LED display can be installed in the following 6 types. Please select appropriate installation type as per site environment:

Preparation work before installation Outdoor LED display frame design should minimize structural weight, while ensuring sufficient mounting strength and should look good. 1. Before installing the cabinet, please check if the steel structure parameters are appropriate: Bottom structure should be stable and solid. Is the structure width and height appropriate? The distance between the 2 square hollow bars (or angle iron) should be the same (when cabinet size is the same). Is the maintenance-channel position appropriate? Check if it is blocking disassembly and maintenance

of power distribution box and modules. Steel structure welding should be firm and complete, surface appearance should be nice and even. 2. Installation order for the cabinets should start from center moving to both sides, and from bottom to top, according to the number of cabinets. Installation methods are as follows. Gently lift and place the cabinets. Be careful not to damage the LED and cabinet structure. Control the installation gap between cabinets. Generally keep within 2mm. After finishing each cabinet row, make sure it is stable and horizontal at the same level before installing an upper row. Cabinet Installation Cabinet Front Installation Remove the corner modules Set up the corner modules Convenient front installation design enables fast installation without maintenance-channel at the back of the display, greatly saving space. Cabinet Rear Installation

Mounting fixing holes *4 Product comes with standard mounting holes, easy for rear installation. Cabinet Installation Method Produce steel structure according to different installation method (Take column installation for example) as shown below:

Cabinet installation sequence: First install the middle cabinet followed by the two sides (see below): Use connecting plates and bolts to fix the cabinet onto the square hallow bar (as shown below): After completing one row of cabinets installation, start installing the next upper row of cabinets. (See below):

Decorate appropriately after the cabinets installation is finished. (See below) Product Wiring Power Cable Wiring Preparation before wiring Before connecting to power supply and switching on control signal to the entire screen, please carefully check the power supply and signal cable connections. Please carefully check the "L" line, "N" line and "PE" of each cabinet s AC inlet, and ensure there is no short circuit between the three lines (Use multimeter to measure). Power cable wiring description Please calculate and select the appropriate distribution box model according to the maximum power consumption of XD6 630 W/m2, XD10 660W/m2. Please consult your distribution box manufacturer for the specific options. The cabinet s input voltage is 100-240 V/AC. Select the distribution box according to the display s total power. When the display s total power is larger than 10 KW, it is generally recommended to use 3-phase 5-wire 380 V/190V input

electricity to the distribution box, then output 220V/110V single-phase electricity from the distribution box to supply power for the display: Note: Lightning proof device, timers, AC contactor, current and voltage sensors are optional as per requirement. Use 3X2.5 mm2 cable to connect from distribution box to cabinet. When input power supply is 220V, each power cable can support maximum 8 cabinets load; when input voltage is 110V, each power cab can support maximum 4 cabinets load. Take XD6 product 6x4 cabinets for example. Following are instructions for power and signal cables connection method: Power cabling: Total power for 24 units of 640x960mm cabinets is 24x0.64x0.96x630W = 14.7KW. Taking into account surplus

requirement and lighting electricity, select a 20 KW main distribution box. The main cable uses 3-phase 5-wire 380V input to the main distribution box. Use 3x2.5 mm 2 power cable to connect from distribution box to the display. Connect each row of 6 cabinets with power cable in series, and then connect the power distribution box to the first cabinet. Power cable can be connected from the left or right cabinet, as shown below: 3X2.5mm² 20KW Distribution Box Network Cabling

Cat 5 USB cable Sending card DVI cable Based on actual situation, network cables can be connected in left-right "Z" type or up-down "S" type format. Please connect the signal cables according to each cabinet s pixels: XD6 (96x144), XD10 (64x96), as per the load range of the transmission card. Please note that the load pixel range of each network interface should be no more than 650,000 pixels. Maintenance Preparation Tools Tools needed include: Allen wrench, Phillips screwdriver, a Multimeter, module front maintenance tools, etc.

Module Front Maintenance Insert tool into the maintenance hole Loosen screws Disassemble the module Module Rear Maintenance Loosen screws Push the module Disassemble the module

Front Maintenance for Power box

Rear Maintenance for Power box Check Power Supply Short Circuit After completing the cabinet wiring, please use a multimeter to measure if there is any short circuit at the AC input power supply (L / N / PE) and DC output terminal (VCC / GND). If there is a short circuit, please carefully investigate the wirings. Make sure all wirings are normal, and only then connect power to operate the unit.