Spherical Geometry Selection Used for Error Evaluation

Similar documents
Acquisition, Reconstruction, and Transformation of a Spiral Near-Field Scan

Uncertainty simulator to evaluate the electrical and mechanical deviations in cylindrical near field antenna measurement systems

ANTENNA SPHERICAL COORDINATE SYSTEMS AND THEIR APPLICATION IN COMBINING RESULTS FROM DIFFERENT ANTENNA ORIENTATIONS

Best-Fit 3D Phase-Center Determination and Adjustment

RANGE MULTIPATH REDUCTION IN PLANE-POLAR NEAR-FIELD ANTENNA MEASUREMENTS

THE ISOFILTER TM * TECHNIQUE: EXTENSION TO TRANSVERSE OFFSETS

PATTERN SYNTHESIS FOR PLANAR ARRAY BASED ON ELEMENTS ROTATION

> Compact range feed horns

Automated Loudspeaker Balloon Measurement M. Bigi, M.Jacchia, D. Ponteggia - Audiomatica

RF TARGET AND DECOY SIMULATOR

ABSORBER FOAM CHARACTERIZATION FOR PREDICTING OVERALL ANECHOIC CHAMBER PERFORMANCE

CONSIDERATIONS FOR UPGRADING A PRE-EXISTING NEAR-FIELD SYSTEM

ANTENNA ALIGNMENT IN A NEAR-FIELD FACILITY

Lecture 2: Introduction

LIMITATIONS OF NEAR-FIELD BACK PROJECTION FOR PHASED ARRAY TUNING APPLICATIONS

USE OF VECTOR ISOMETRIC ROTATIONS IN THE MEASUREMENT OF IMPERFECTLY ALIGNED ANTENNAS

Measuring Wide Angle Antenna Performance Using Small Cylindrical Scanners

APPENDIX B PROGRAMS USED IN POLARIZATION-SENSITIVE PROPAGATION MODELING

GBT Commissioning Memo 11: Plate Scale and pointing effects of subreflector positioning at 2 GHz.

Automated Loudspeaker Balloon Response Measurement

Achieving Impressive Global Positioning and Stability in a High Fidelity Antenna Measurement System

Application of the Translated-SWE Algorithm to Echo Reduction of Spherical Near-Field Measurements with Undersampling

USING A TRACKING LASER INTERFEROMETER TO CHARACTERIZE THE PLANARITY OF A PLANAR NEAR-FIELD SCANNER

New Modelling Capabilities in Commercial Software for High-Gain Antennas

RCS CALCUATIONS USING THE PHYSICAL OPTICS CODES

Experiment 8 Wave Optics

FM Antenna Pattern Evaluation using Numerical Electromagnetics Code

APPLICATIONS FOR COORDINATED MOTION IN RADOME TESTING

Design of Electromagnetic Test Sites

A systematic approach to the analysis of polarisation-sensitive reflectors

Performance Studies of Antenna Pattern Design using the Minimax Algorithm

Ultrasonic Multi-Skip Tomography for Pipe Inspection

PROPEL 5G PROcedures and techniques for Proving compliance to Exposure Limits of 5G wireless devices

A R T A - A P P L I C A T I O N N O T E

Improved Detector Response Characterization Method in ISOCS and LabSOCS

Nanoparticle Optics: Light Scattering Size Determination of Polystryene Nanospheres by Light Scattering and Mie Theory

Directivity Measurement with Turntables AN54

High spatial resolution measurement of volume holographic gratings

FOCAL-PLANE SCANNER FOR MEASURING RADOME BEAM DEFLECTION IN A COMPACT RANGE

CATR Quiet Zone Modelling and the Prediction of Measured Radiation Pattern Errors:

Three-Dimensional Laser Scanner. Field Evaluation Specifications

and Flat-Panel Constant Beamwidth Transducer (CBT) Loudspeaker Arrays Using Signal Delays

Design of concentric ring antenna arrays for isoflux radiation in GEO satellites

Bessel and conical beams and approximation with annular arrays

Gregory Walsh, Ph.D. San Ramon, CA January 25, 2011

New Approach to finding Active-element Patterns for Large Arrays

PHYSICS 1040L LAB LAB 7: DIFFRACTION & INTERFERENCE

G017 Beyond WAZ - A Modeling-based Evaluation of Extensions to Current Wide Azimuth Streamer Acquisition Geometries

Over the Air Evaluation of Mobile Phone Antenna Performance for Voice over LTE Di Paola, Carla; Karstensen, Anders; Fan, Wei; Pedersen, Gert F.

Forward Time-of-Flight Geometry for CLAS12

ALOS-2 PALSAR-2 support in GAMMA Software

THE growing number of sensor and communication systems

Development of Focal-Plane Arrays and Beamforming Networks at DRAO

VISUALIZING THE 3D POLAR POWER PATTERNS AND EXCITATIONS OF PLANAR ARRAYS WITH MATLAB

EUROPEAN RESEARCH PROJECT RE-VIS, DAYLIGHTING PRODUCTS WITH REDIRECTING VISUAL PROPERTIES

Mode-Field Diameter and Spot Size Measurements of Lensed and Tapered Specialty Fibers

Predicting the mechanical behaviour of large composite rocket motor cases

Other Major Component Inspection I

ISOCS Characterization of Sodium Iodide Detectors for Gamma-Ray Spectrometry

LC-1: Interference and Diffraction

Image Acquisition Systems

Good Practice guide to measure roundness on roller machines and to estimate their uncertainty

Development and Applications of an Interferometric Ground-Based SAR System

Azimuthal Anisotropy Investigations for P and S Waves: A Physical Modelling Experiment

Simulation in NDT. Online Workshop in in September Software Tools for the Design of Phased Array UT Inspection Techniques

newfasant US User Guide

GEOMETRICAL SURVEY OF COMPACT ANTENNA TEST RANGES USING LASER TRACKER TECHNOLOGY

INVESTIGATIONS ON THE ANALYSIS AND DESIGN OF APERIODIC FREQUENCY SELECTIVE SURFACES FOR SPACE APPLICATIONS

SLL REDUCTION IN APERIODIC LINEAR ARRAY ANTENNA SYSTEM WITH SCAN ANGLES

AUTOMATED 4 AXIS ADAYfIVE SCANNING WITH THE DIGIBOTICS LASER DIGITIZER

COMPACT RANGE CALIBRATION AND ALIGNMENT

3 - SYNTHETIC APERTURE RADAR (SAR) SUMMARY David Sandwell, SIO 239, January, 2008

Aradar target is characterized by its radar cross section

Christian Doppler Laboratory for Dependable Wireless Connectivity for the Society in Motion Three-Dimensional Beamforming

Polarization of light

Experiment 5: Polarization and Interference

PHYS 202 Notes, Week 8

Plane Wave Imaging Using Phased Array Arno Volker 1

Slide 1. Technical Aspects of Quality Control in Magnetic Resonance Imaging. Slide 2. Annual Compliance Testing. of MRI Systems.

Designing Horn Antenna utilizing FEM Symmetry Boundary Conditions

NEAR-FIELD measurement techniques are a fundamental

Engineered Diffusers Intensity vs Irradiance

Abstract. 1 Introduction

Chapter 5. Track Geometry Data Analysis

Chapter 2 Research on Conformal Phased Array Antenna Pattern Synthesis

generator graphical interface for generating the IHRSR script

/ MHz

CHAPTER 3. Preprocessing and Feature Extraction. Techniques

Increasing Machine Service Life of Large Envelope, High Acceleration AFP Machines

In-Situ Measurements of Surface Reflection Properties

New Results on the Omega-K Algorithm for Processing Synthetic Aperture Radar Data

SUPPLEMENTARY INFORMATION

Back Projection of the Okhotsk earthquake on the vertical plane. To test the candidate geometry of a vertical fault, we perform the BP analysis on the

LAB 2: DATA FILTERING AND NOISE REDUCTION

(Refer Slide Time: 00:10)

Polarized light scattering measurements of roughness, subsurface defects, particles, and dielectric layers on silicon wafers

Novel Method to Improve the Signal-to-Noise Ratio in Far-Field Results Obtained from Planar Near-Field Measurements

Measurement of 3D Room Impulse Responses with a Spherical Microphone Array

HFSS - Antennas, Arrays and FSS's. David Perry Applications Engineer Ansoft Corporation

Mie scattering off plasmonic nanoparticle

Transcription:

Spherical Geometry Selection Used for Error Evaluation Greg Hindman, Pat Pelland, Greg Masters Nearfield Systems Inc., Torrance, CA 952, USA ghindman@nearfield.com, ppelland@nearfield.com, gmasters@nearfield.com Abstract Spherical near-field error analysis is extremely useful in allowing engineers to attain high confidence in antenna measurement results. NSI has authored numerous papers on automated error analysis and spherical geometry choice related to near field measurement results. Prior work primarily relied on comparison of processed results from two different spherical geometries: Theta-Phi ( θ 18, -18 φ 18) and Azimuth-Phi (-18 θ 18, φ 18). Both datasets place the probe at appropriate points about the antenna to measure two different full spheres of data; however probe-to-antenna orientation differs in the two cases. In particular, geometry relative to chamber walls is different and can be used to provide insight into scattering and its reduction. When a single measurement is made which allows both axes to rotate by 36 degrees both spheres are acquired in the same measurement (redundant). They can then be extracted separately in post-processing. In actual fact, once a redundant measurement is made, there are not just two different full spheres that can be extracted, but a continuum of different (though overlapping) spherical datasets that can be derived from the single measurement. For example, if the spherical sample density in Phi is 5 degrees, one can select 72 different full sphere datasets by shifting the start of the dataset in increments of 5 degrees and extracting the corresponding single-sphere subset. These spherical subsets can then be processed and compared to help evaluate system errors by observing the variation in gain, sidelobe, cross pol, etc. with the different subset selections. This paper will show the usefulness of this technique along with a number of real world examples in spherical near field chambers. Inspection of the results can be instructive in some cases to allow selection of the appropriate spherical subset that gives the best antenna pattern accuracy while avoiding the corrupting influence of certain chamber artifacts like lights, doors, positioner supports, etc. spherical measurements is the use of a double-sphere measurement [3]. Double-sphere measurements provide a way of comparing and/or averaging data acquired with AUT illuminating opposite points in the chamber between the two spheres. Recently, this technique has been extended to allow greater detail to be gleaned from the double-sphere measurements. This technique has been named Phi Filtering and this paper will discuss the implementation and effectiveness of this technique. II. HISTORY OF THE USE OF DOUBLE-SPHERE MEASUREMENTS Typical antenna measurements taken in a spherical Theta- Phi coordinate system move the probe relative to the antennaunder-test (AUT). To measure the full sphere, the Theta (θ) or Phi (φ) coordinate needs to move over 36 degrees (doublesided) while the other coordinate need only rotate 18 degrees (one-sided). Examples of these would be: -18 θ +18, φ +18 (θ: double-sided) θ +18, -18 φ +18 (φ: double-sided) If we allow both Theta and Phi to rotate a full 36 degrees each then the probe and AUT move relative to each other over a double sphere. -18 θ +18, -18 φ +18 (θ,φ: double-sided) Double-sphere techniques for evaluating multipath have been discussed in previous AMTA papers [3], [4], [5]. When a double-sphere measurement is performed, various subsets of the double-sphere can be extracted to be transformed to the farfield individually, or can be averaged with other single-spheres and then transformed to the far-field. I. INTRODUCTION The NIST 18-term error assessment originally developed for planar near-field measurements [1]has been adapted for spherical near-field (SNF) systems [2]and provides an accurate measure of the uncertainty in a particular SNF measurement. Once particular measurement errors are known, steps can be taken to reduce their impact on far-field radiation patterns. One of the most common and impactful sources of error in spherical near-field measurements is the presence of chamber multipath. One particularly effective technique for evaluating multipath in Figure 1. Near-Field Amplitude Distribution for a Double- Sphere Measurement (Left) and Two Single-Sphere Subsets

Figure 1. shows a double-sphere of data on the left and two subsets of that double-sphere on the right. First, the singlesphere labeled +Phi corresponds to the region where -18 θ +18, φ +18. Similarly, the single-sphere labeled -Phi corresponds to the region where -18 θ +18, -18 φ. Both spheres of near-field data can be transformed to the far-field and the resulting difference between the two far-field datasets will be a function of room scattering. By coherently averaging the difference we can reduce the scattering effects. equatorial mode so that its main beam illuminated the probe when (Theta, Phi) = (9 degrees, degree) as shown in Figure 5. III. PHI FILTERING Once a double-sphere of data is measured a single-sphere can be extracted by choosing a subset of that data with a measurement span of only 18 degrees in Phi. In the previous case (Figure 1. ) the two spheres considered were: -18 θ +18, φ 18 (+Phi) -18 θ +18, -18 φ (-Phi) In fact, these are not the only single-spheres available to be extracted and transformed to the far-field. If we allow Phi to start at any angle and stop after a span of 18 degrees has been realized we can get a multitude of spheres by sliding the 18 degrees Phi-filter to different starting points. Figure 2. shows the case where the Phi-filter spans the region -9 φ +9. Each of these available Phi-filtered spheres can then be transformed to the far-field and compared to give greater detail of the multi-path environment. The number of available spheres depends on the near-field Phi sampling density used during the double-sphere acquisition. Figure 3. NSI-7S-11 SNF System in Anechoic Chamber Top View Figure 4. X-Band Slotted Waveguide Array Under Test on the NSI-7S-11 SNF System Figure 2. Phi-Filter Window Slid to Cover the Range -9 < Phi < +9 IV. TEST CONFIGURATION To evaluate the effectiveness of the Phi-filtering technique a set of tests was conducted using one of NSI s Theta-over-Phi SNF systems in a small anechoic chamber in the NSI laboratory (see Figures 3 thru 5). The NSI-7S-11 SNF test system allows measurements of small antennas up to 2 in (5 mm) in diameter over frequency ranges up to 1 GHz. Here, an X-band slotted waveguide array was mounted as AUT in Figure 5. SWGA Mounted in Equatorial Mode with NSI Dual-Polarized Probe Mounted to Theta Swing Arm. (Phi= and Theta=9 Shown Here)

A partial double-sphere measurement was made over the range: -165 θ +165, -18 φ 18 Once the measurement was completed, the Phi-filter technique was employed to evaluate results obtained over multiple single-spheres by sliding the Phi-filter. Figure 6. shows four of these single-spheres where the Phi-filter is centered at Phi =, 9, 18, 27. For two of these singlespheres ( degree, 18 degrees) the Phi-filter will be centered on the main beam of the SWGA s radiation pattern. The other two single-spheres (9 degrees, 27 degrees) will have the main beam split at the edges of the Phi span. The four singlespheres are outlined below: -18 θ +18, -9 φ 9 (-centered) -18 θ +18, φ 18 (9-centered) -18 θ +18, 9 φ -9 (18-centered) -18 θ +18, -18 φ (27-centered) Figure 6. NSI-7S-11 SNF System Showing that Four Different Phi-Axis Positions of the SWGA ( Phi =, 9, 18, 27 ) Will Illuminate Different Walls of the Chamber V. FAR-FIELD PATTERN RESULTS Transformed far-field pattern data was processed with different Phi-filters to evaluate the effect on various antenna parameters. Sidelobe level, cross-pol, directivity, beam pointing and beamwidth were all evaluated for this study and were automatically calculated and tabulated using the Phi-filter routine. For this measurement, the sampling density was 2.5 degrees so data was transformed to the far-field using singlespheres with the filter sliding from to 35 degrees in 25 degrees steps. Figure 7. shows far-field Phi-cuts calculated using each of the extracted single-spheres. The pattern obtained from transforming the measured double-sphere is also overlaid as the bold, dashed curve. The results shown clearly indicate that sidelobe variations are present when different single-spheres are compared. This pattern variation is a result of the AUT (mounted here in equatorial mode) illuminating different parts of the chamber and scanner with different Phi-filters applied. Far-field amplitude of Rockwell 14inch SWGA_5.NSI. 25. 5. 75. 1. 125. 15. 175. 2. 225. 25. 275. 3. 325. 35. Coherent Average all phi 5 1 15 Figure 7. Multiple Far-Field Main Component Phi-Cuts Resulting from Different Single-Spheres with Sliding Phi- Filter Center While the NSI2 software and Phi-filter routine transform the single-sphere datasets to the far-field, they also automatically export a table summarizing the variation of other parameters of interest. This summary allows the range operator to identify the location of scattering bodies in the chamber and to either perform the necessary physical adjustments or acquire data over a Phi range that excludes the largest multipath effects The first sidelobe on the plus and minus sides of the main beam were also chosen for closer analysis to quantify the variation resulting from this Phi-filter experiment. The first minus and plus sidelobes are located at roughly Phi = -11 degrees and +21 degrees, respectively. Figure 8. shows the farfield amplitude at these positions for datasets transformed using the same set of Phi-filters described above. The variation in sidelobe amplitude evident in Figure 8. is a result of differences in multipath effects when the AUT points to different parts of the chamber. As the Phi-filter slides over the available filter range various scattering bodies in the chamber (walls, door, scanner, etc.) become more or less evident. For example, the largest variation for the right SLL appears when the Phi-filter is centered close to Phi = 27 degrees. At this position, the AUT is pointed at the scanner s swing arm, the closest scattering body in the chamber.

Figure 8. Sensitivity of Phi-Filter Window Center on First SLL on LHS and RHS Next, the same set of Phi-filters was used to analyze the array s cross-polarized pattern. Figure 9. shows the resulting far-field plots overlaid along with the bold, dashed doublesphere average. Once again, variations are observed in the amplitude vs. Phi angle and these variations can be attributed to differences in the scattering environment as the Phi-filter slides. Far-field amplitude of Rockwell 14inch SWGA_5.NSI. 25. 5. 75. 1. 125. 15. 175. 2. 225. 25. 275. 3. 325. 35. Figure 1. Peak Directivity Calculated using Various Phi- Filter Positions Coherent Average all phi 5 1 15 Figure 9. Multiple Far-Field Cross Component Phi-Cuts Resulting from Different Single-Spheres with Sliding Phi- Filter Center As the NSI2 processing also exports other parameters, we can review and analyze additional details. See Figure 1. thru Figure 12. for the resulting variations for peak directivity, 3 db beamwidth, and beam pointing. Figure 11. Figure 12. 3 db Beamwidth Calculated using Various Phi- Filter Positions Beam Peak Location Calculated using Various Phi-Filter Positions

Amplitude (db) VI. SUMMARY OF MEASUREMENT UNCERTAINTIES Based on the results of the different single-spheres transformed with the sliding Phi-filter window, one can assemble a table of measurement uncertainties for a number of parameters. A vector average of all the sphere calculations is used, and then the uncertainty is calculated as the standard deviation of the multiple sphere results. Table I. below shows the resulting uncertainties. TABLE I. UNCERTAINTY VARIATION DERIVED FROM PHI-FILTER PROCESSING Far-field amplitude of Rockwell 14inch SWGA_9.NSI 9 doors open phicenter 27 5 doors closed Parameter Value Uncertainty LHS first SLL at -11.35 db ±.48 db RHS first SLL at 21-29.39 db ±.24 db Directivity 29.3 dbi ±.1 db Azimuth 3 db Beamwidth 6.87 ±.2 Azimuth Pointing.21 ±.13 VII. PERTURBATION STUDIES This technique can be used to intelligently choose which spheres to include in evaluation of AUT performance. For instance, certain parts of an anechoic chamber like the absorber coverage of the door may induce higher reflections. To illustrate this idea more clearly, a gross error was introduced by leaving one of the chamber doors open during a measurement of the SWGA. The plot on the left of Figure 13. shows the near-field amplitude response of the double-sphere measurement performed with the chamber door open. In this image, the effects of room scattering are very evident in the range of φ 18. The plot on the right shows a Phi cut comparing data acquired with the door open to known good data acquired with the door closed. The Phi angles corresponding to the location of the door show very large pattern corruption due to room scattering effects. 5 1 15 Figure 14. Near-Field Amplitude Response After Applying Phi-Filter Routine (Left) and Far-Field Pattern Results with Door Open and Closed (Right) VIII. CONCLUSION This paper has shown a novel use of a double-sphere dataset for analyzing room scattering errors and minimizing them. Once a double-sphere measurement is made, there are a continuum of different (though overlapping) spherical datasets that can be derived from the single measurement. These spherical subsets can be processed and then compared or averaged to help evaluate system errors by observing the variation in gain, sidelobe, cross pol, etc. with the different subset selections. Inspection of the results can be instructive in some cases to allow selection of the appropriate spherical subset that gives the best antenna pattern accuracy while avoiding the corrupting influence of certain chamber artifacts like lights, doors, positioner. Far-field amplitude of Rockwell 14inch SWGA_9.NSI 9 -Y doors open 5 doors closed 5 1 15 Figure 13. Near-Field Amplitude Response of Double- Sphere Measurement Performed with Door Open (Left) and Far-Field Pattern Results with Door Open and Closed (Right) Using the Phi-filter technique, the range of 18 φ 36 can be selected for processing, as shown in Figure 14. Now, the results acquired with the door open compare very favorably to those acquired with the door closed, provided the scattering region is filtered out. REFERENCES [1] A. Newell, Error Analysis Techniques for Planar Near-Field Measurements, IEEE Trans Antennas & Propagation, AP-36, p. 581, 1988. [2] G. Hindman, A. Newell, Simplified Near-Field Accuracy Assessment, Proc. Antenna Measurement Techniques Association (AMTA) Annual Symp., 26. [3] G. Hindman, A. Newell, Spherical Near-Field Self-Comparison Measurements, Proc. Antenna Measurement Techniques Association (AMTA) Annual Symp., 24. [4] G. Hindman & A. Newell, Mathematical Absorber Reflection Suppression (MARS) for Anechoic Chamber Evaluation and Improvement, Proc. Antenna Measurement Techniques Association (AMTA) Annual Symp., 28. [5] Newell, Hindman, Antenna Pattern Comparison Using Pattern Subtraction and Statistical Analysis, The 5 th European Conference on Antennas and Propagation (EuCAP 211)